Articles

10 Critical Steps to World Class Reference Standards

Whether it’s a stock, off-the-shelf reference standard or a one-of-a-kind, custom-formulated solution, there are 10 critical steps that Restek takes to separate our reference standards from the competition:

31 Aug 2026

header article gnss1556 new look scaled

Here’s what happens behind the scenes to ensure every ampul meets the accuracy, purity, and documentation standards your analysis depends on.

01 | Review Customer & Method Requirements

To determine which organic reference standards we should develop as stock products, Restek experts closely monitor government regulations and methods from around the globe and also actively engage with our customers and distributors. Once a product is chosen based on regulatory changes, customer needs, and our 35+ years of experience, a veteran Restek chemist formulates a stable standard containing an ideal mix of compounds and concentrations. All formulations are then subjected to a thorough review of accuracy, compatibility, and solubility by a second chemist.

02 | Verify Compatibility & Stability

All raw materials used in our reference standards are held to strict purity criteria, and compound compatibility is scrutinized during both formulation and review. We also conduct ongoing, long-term stability and short-term shipping stability studies in accordance with ISO 17034 and ISO Guide 35 to ensure reliability and accurate shelf-life reporting—at least 95% of our products provide a 12-month shelf life or longer.

03 | Characterize Raw Materials Thoroughly

Restek’s Quality Control (QC) lab confirms the chemical identity and purity of mixture components and solvents using two or more of the following techniques: GC-FID, HPLC, GC-ECD, GC-MS, LC-MS, refractive index, and melting point.

04 | Calibrate Analytical Balances

All analytical balances are verified at seven mass levels daily using NIST* traceable weights and are also calibrated yearly by an ISO/IEC 17025-accredited provider to guarantee accurate measurement.
*National Institute of Standards and Technology

05 | Proprietary Deactivation of Glassware & Ampuls

Restek reference standards are prepared using Class A volumetric flasks and/or Class A pipettes. Ampuls and vials used in preparation and packaging undergo Restek’s proprietary deactivation process to prevent the loss of target analytes.

06 | Maintain ISO Accreditation

The reference standard manufacturing and QC testing laboratories in Restek’s state-of-the-art Bellefonte, PA, facility feature ISO 17034 and ISO/IEC 17025 accreditation. These accreditations—in addition to ISO 9001 registration, which we have maintained since 1994—serve as recognition that Restek and our labs meet the world-class quality standards established by the International Organization for Standardization (ISO). On-site manufacturing as well as raw material, qualitative, and quantitative analyses are completed in these ISO-accredited labs, including a dedicated facility for PFAS standards manufactured to 99.8% purity. Restek’s ISO-accredited labs offer a full line of both stock and custom CRMs. 

Learn more at www.restek.com/iso

07 | Offer a Variety of Documentation

Restek exclusively offers three levels of fully ISO-compliant documentation for our reference standards, and most stock standards come with Certificate of Analysis–Chromatographic Plus documentation.

Certificate of Analysis – Gravimetric includes all raw material information, lot numbers and purity, isomer ratios for isomeric compounds, and calculated concentration(s). Associated uncertainties are also included for certified reference materials (CRMs).

Certificate of Analysis – Chromatographic includes all raw material information, lot numbers and purity, isomer ratios for isomeric compounds, and calculated concentration(s). Associated uncertainties are also included for certified reference materials (CRMs). Additionally, a single sample is withdrawn from the packaged units and is tested via an appropriate technique to verify mixture composition. A chromatogram of the analyzed standard, with each peak identified, is included on the certificate.

Certificate of Analysis – Chromatographic Plus includes all raw material information, lot numbers and purity, isomer ratios for isomeric compounds, and calculated concentration(s). Associated uncertainties are also included for certified reference materials (CRMs). Additionally, a sample of the packaged units is analyzed in triplicate, and the peak areas are statistically compared to a second lot which is either a previous lot (if available) or a freshly produced independent second lot. A chromatogram of the analyzed standard, with each peak identified, is included on the certificate. Plus, a detailed data pack containing the product certificate, all quantitative assay data and statistics, and the Reference Material Batch Record are available at www.restek.com/documentation.

08 | Package Securely & Label Clearly

Every Restek standard is placed in compact, durable, and environmentally friendly packaging for dock-to-door protection. Provided notebook and vial labels provide critical storage, safety, and shelf-life information in an easy-to-read format for added safety and GHS compliance. QR codes on the ampul storage tube give you instant access to the certificate of analysis for your specific standard and lot # on Restek.com.

09 | Convenience and Safety Included with Each Ampul

As an added bonus, we include a deactivated screw-top vial (cat.# 24640) with each stock reference standard <5 mL for worry-free transfer. Every order also includes a free Restek Safe Cracker.

10 | Manage Warehouse Inventory

To ensure the inventory is available when it’s needed, Restek continually analyzes and maintains inventory of more than 1200 catalog standards and multiple lots of the most commonly requested calibration standards—as well as more than 6300 neat compounds. We pull inventory months before its expiration date to eliminate inadvertent delivery of expired or nearly expired reference standards.

figure article GNSS1556E 01

Frequently Asked Questions

A CRM is a reference standard that meets strict criteria defined under ISO 17034 and ISO/IEC 17025: it’s made of raw materials characterized via qualified methods on qualified instruments, produced in an ISO-accredited lab under documented procedures, and falls under the manufacturer’s scope of accreditation. Learn more about Restek’s ISO quality credentials at restek.com/iso.

Yes. Along with primary- and secondary-source reference standards, Restek supplies GC and LC columns, sample prep products, and accessories, so you can consolidate your lab’s ordering with a single trusted source instead of managing multiple vendors.

Stock standards are preformulated, cataloged, and typically ready to ship from Restek’s active inventory. Custom standards are formulated to your exact specifications by our formulations chemists, and when a stock product doesn’t meet your needs, and both are backed by the same ISO scopes of accreditation.

At least 95% of Restek’s reference standards provide a 12-month shelf life or longer, backed by ongoing long-term stability and short-term shipping stability studies conducted in accordance with ISO 17034 and ISO Guide 35.

NIST-traceable means a measurement can be traced back to standards maintained by the National Institute of Standards and Technology through an unbroken chain of calibrations. Restek’s analytical balances are verified at seven mass levels daily using NIST-traceable weights, helping ensure every standard’s concentration is measured accurately.

Yes. Restek routinely prepares two independently produced lots of stock reference materials using two technicians and two different NIST-traceable balances, so we can serve as both your primary and secondary source without adding another vendor to your procurement process.

Need Help with Reference Standards?

From method selection to product recommendations, our reference standards experts are here to help you navigate complex workflows and achieve accurate, reliable results.

Author

  • Restek Corporation

    Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions.

    View Articles
GNSS1556
Version: G