- Sample Matrix: emissions from stationary sources
- Sample Preparation: collection in passivated stainless-steel canisters
- Detection Technique: GC-MS
Other Test Method 50 (OTM-50): Sampling and Analysis of Volatile Fluorinated Compounds from Stationary Sources Using Passivated Stainless-Steel Canisters
U.S. EPA Method OTM-50 is a performance-based draft method that can be used for the analysis of 30 volatile fluorinated compounds (VFC) in air emissions from stationary sources. It includes multiple short-chain VFC, which may be monitored as indicators of incomplete PFAS decomposition. Emission samples are collected in passivated stainless-steel canisters and then analyzed by GC-MS using a PLOT column. Draft Method OTM-50 was released to encourage a consistent process for facilities, stationary source test teams, research laboratories, and other stakeholders and to promote discussion and further evaluation of the method. The full analyte list and recommended products for collecting volatile fluorinated compounds in emissions for analysis by Method OTM-50 are provided below.
Analyte List for EPA Method OTM-50 for Volatile Fluorinated Compounds in Emissions
| Compound Name | CAS# |
| Carbon tetrafluoride | 75-73-0 |
| Hexafluoroethane (FC-116) | 76-16-4 |
| Tetrafluoroethene | 116-14-3 |
| Trifluoromethane (HFC-23) | 75-46-7 |
| Octafluoropropane | 76-19-7 |
| Difluoromethane (HFC-32) | 75-10-5 |
| Fluoromethane (HFC-41) | 593-53-3 |
| Pentafluoroethane (HFC-125) | 354-33-6 |
| Hexafluoropropene | 116-15-4 |
| Hexafluoropropene oxide (HFPO) | 428-59-1 |
| Decafluorobutane | 355-25-9 |
| Dodecafluoropentane | 678-26-2 |
| Tetradecafluorohexane | 355-42-0 |
| 1H-Perfluoropentane | 375-61-1 |
| Hexadecafluoroheptane | 335-57-9 |
| Heptafluoropropyl-1,2,2,2-tetrafluoroethyl ether (E1) | 3330-15-2 |
| 1H-Perfluorohexane | 355-37-3 |
| 1H-Perfluoroheptane | 375-83-7 |
| 2H-Perfluoro-5-methyl-3,6-dioxanonane (E2) | 3330-14-1 |
| 1H-Perfluorooctane | 335-65-9 |
| Octadecafluorooctane | 307-34-6 |
| 1H-Nonafluorobutane | 375-17-7 |
| 1H-Heptafluoropropane | 2252-84-8 |
| 1,1,1,2-Tetrafluoroethane (HFC-134a) | 811-97-2 |
| 1,1,1-Trifluoroethane (HFC-143a) | 420-46-2 |
| Chlorodifluoromethane (HCFC-22) | 75-45-6 |
| Chlorotrifluoromethane (CFC-13) | 75-72-9 |
| Octafluorocyclobutane (FC-C318) | 115-25-3 |
| Octafluorocyclopentene (FC-C1418) | 559-40-0 |
| Trichloromonofluoromethane (CFC-11) | 75-69-4 |
Recommended Products for EPA Method OTM-50 for Volatile Fluorinated Compounds in Emissions
Sample Collection

Need Help with Your PFAS Analysis?
From method selection to product recommendations, our PFAS experts are here to help you navigate
complex workflows and achieve accurate, reliable results.
Discover More Solutions for PFAS Analysis!
Start Saving
Time Today
Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler
Start Saving Time Today
Develop PFAS Methods in Minutes with our Pro EZLC Chromatogram Modeler


