Table I: For specific applications, we recommend using these optimized columns for better method performance. Click on the column name for product specifications and easy online ordering.
| Application | Column | Feature | Benefit |
|
ASTM Method D3606 |
Column 1: Backflush column, 6′ (1.8 m), 1/8″ OD, 2.0 mm ID; Column 2: proprietary packing, 16′ (4.9 m), 1/8″ OD, 2.0 mm ID D3606 GC Capillary Column Set |
Excellent separation of ethanol and benzene for ethanol blended fuels.
Accurate quantitation of toluene and benzene, including benzene in gasoline containing ethanol or butanol blends. |
Reliably meets method requirements. Reliably meets method requirements. |
|
Refinery Gases |
Optimized three-column set. (Backflush column sold separately.) |
Elutes C5 hydrocarbons before C1-C4 hydrocarbons for optimized resolution. |
|
|
Unsaturated Light Hydrocarbons |
Unique selectivity for unsaturated hydrocarbons. |
Excellent resolution of unsaturated light hydrocarbons gives increased data accuracy. |
|
|
cis-2-Butene and 1,3-Butadiene |
Optimized selectivity for cis-2-butene and 1,3-butadiene resolution. |
Increased data accuracy. |
|
|
Permanent Gases |
ShinCarbon ST Columns |
Optimized selectivity for permanent gas resolution without cryogenic cooling. Preconditioned. |
Increases productivity. |
|
Low-Level Sulfurs |
Rt-XLSulfur Columns |
Highly inert for ppbv levels of sulfur. Eliminates need for PTFE tubing. |
Increased data accuracy for low-level sulfur analysis. Eliminates need for a special GC setup. |
Table II: Select the packed column configuration that fits your instrument from the options below and add the corresponding suffix to any standard part number.
(Note that small OD columns [1/16” or less] do not require a suffix.)
| Suffix | Configuration |
|
-800 |
General |
|
-810 |
Agilent Standard |
|
-811 |
Agilent 6850 |
|
-820 |
Varian Standard |
|
-821 |
Varian 3800 |
|
-830 |
PE 900-3920; Sigma 1,2,3 |
|
-840 |
PE Standard |
|
-845 |
ABB |
|
-850 |
Shimadzu 14A, 2014 |
|
-851 |
Shimadzu 8A |
|
-853 |
Shimadzu 17A, 2010 |
|
-860 |
Thermo TRACE 2000 |
|
-875 |
Analytical Controls |
|
-890 |
Gow Mac 590 |
|
-891 |
Gow Mac 550 |
|
-893 |
Gow Mac 816 |
|
-895 |
SRI 8610C |
Complete your column with one of our fitting kits.
| Option* | Description |
|
Kit 1S |
Fitting Kit: 1/4″ Brass Nuts, |
|
Kit 2S |
Fitting Kit: 1/4″ Brass Nuts, |
|
Kit A |
Fitting Kit: 1/8″ Brass Nuts, |
|
Kit B |
Fitting Kit: 1/8″ Brass Nuts, |
|
Kit B2 |
Fitting Kit: 1/4″ Brass Nuts, |
|
Kit C |
Fitting Kit: 1/8″ SS Nuts, |
|
Kit D |
Fitting Kit: 1/8″ SS Nuts, |
|
Kit E |
Fitting Kit: 1/4″ SS Nuts, |
|
Kit F |
Fitting Kit: 1/4″ SS Nuts, |
|
Kit G |
Fitting Kit: 1/4″ SS Nuts, |
|
Kit VNICKEL |
Fitting Kit: 1/8″ VCR fittings (Nickel) |
|
Kit VSS |
Fitting Kit: 1/8″ VCR fitting (SS) |
|
Preconditioning |
Optional for each finished column |
*Some options available at additional cost.