Skip to content
Language Selector Globe Icon

Select Language:

  • wpml-ls-flagEnglish
    • wpml-ls-flagFrançais
    • wpml-ls-flagDeutsch
    • wpml-ls-flagItaliano
    • wpml-ls-flag日本語
    • wpml-ls-flag简体中文
    • wpml-ls-flagEspañol
  • SDS & COA Search
  • Contact Us
Restek Corporation logo and link to discover.restek.com home page
  • Industries & Applications

      Browse By Applications

      • Cannabis
      • Medical or Recreational Cannabis
      • Hemp & Hallucinogens
      • Chemical Production
      • Clinical
      • Clinical Diagnostics
      • Clinical Research
      • Clinical Toxicology
      • Energy
      • Refining
      • Fuel Production
      • Hydrocarbon Gases
      • Environmental
      • Air Monitoring
      • Industrial Hygiene
      • PFAS Testing
      • Drinking Water & Wastewater Testing
      • Soil, Sediment, Biota Testing
      • Food & Beverage
      • Food Quality
      • Food Safety
      • Forensics
      • Forensics Toxicology
      • Pharmaceutical & Biopharma

      Chromatogram Library

      Browse our library of hundreds of GC and LC chromatograms.

      Search Now
  • Product Library

      Browse By Product

      • Gas Chromatography Products
      • GC Columns
      • Ferrules, Fittings, Connectors
      • Inlet Supplies
      • Instrument Supplies & Tools
      • Detector Supplies
      • Tubing & Regulators
      • Gas Purification & Generators
      • Liquid Chromatography Products
      • LC Columns
      • LC-MS Supplies
      • LC Autosampler Supplies
      • Mobile Phase Management
      • LC Detector Supplies
      • LC Tubing & Fittings
      • LC Pump Supplies
      • Tools & Organization
      • Reference Standard Products
      • Liquid Reference Standards
      • Gas Standards & Accessories
      • Sample Preparation Products
      • QuEChERS Products
      • In-Line Sample Preparation (ILSP)
      • SPE & SPLE
      • SPME
      • ASE Extraction
      • Vials & Accessories
      • Coated Blade Spray
      • Air & Gas Sampling Products
      • Canisters & Accessories
      • Sample Cylinders & Accessories
      • Gas Sampling Bags & Accessories
      • Gas Standards & Accessories
      • Personal Air Samplers & Accessories
      • Air Sampling Bottles & Valves
      • Custom Product Builders

      Chromatogram Library

      Browse our library of hundreds of GC and LC chromatograms.

      Search Now
  • Education & Training

      Browse By Topic

      • Air Sampling
      • Gas Chromatography (GC)
      • GCxGC
      • Headspace
      • HILIC
      • Injection Techniques
      • Liquid Chromatography
      • Low-Pressure GC (LPGC)
      • Mass Spectrometry (MS)
      • MS/MS
      • QuEChERS
      • Solid-Phase Extraction (SPE)
      • Solid-Phase Microextraction (SPME)

      Chromatography on demand!

      Browse our library of expert videos on troubleshooting, method development and more.

      Watch Now
  • Tools

      Browse Tools & Calculators

      • EZ Chromatogram Modellers
      • Chromatogram Library
      A magnifying glass highlighting a reference standard, with additional
reference standards in the background.

      Find Reference Standards Fast

      Access the NEW Reference Standards Finder to search, filter, and download a list of matched standards in minutes.

      Start Your Search

      Develop Methods in Seconds

      Model and optimize chromatograms in seconds with our Pro EZGC & EZLC Chromatogram Modelers

      Try them now!
  • Resources

      Browse Resources

      • Application Notes
      • Articles
      • Blogs
      • External Publications
      • Frequently Asked Questions (FAQ)
      • Videos

      Develop Methods in Minutes

      Free Chromatogram Modeling & Optimization Tools

      Try them now!

      PFAS Analysis Resources

      Method guides and products for PFAS analysis

      View Resources
  • Our Company

      Learn More About Restek

      • About Us
      • Press Releases & News
      • Events
      • Careers

      Are you ownership material?

      At Restek, you don’t just work here—you own it. We’re independent, innovative, and passionate about helping people succeed. Join our team of employee-owners and grow with us.

      Browse Openings Find Your Fit
  • Explore Product Catalog
Restek Corporation logo
  • Contact Us
Explore Product Catalog
Restek Corporation logo
  • Industries & Applications
    • Cannabis
      • Medical or Recreational Cannabis
      • Hemp & Hallucinogens
      • All Cannabis
    • Chemical Production
    • Clinical
      • Clinical Diagnostics
      • Clinical Research
      • Clinical Toxicology
      • All Clinical
    • Energy
      • Refining
      • Fuel Production
      • Hydrocarbon Gases
      • All Energy
    • Environmental
      • Air Monitoring
      • Industrial Hygiene
      • PFAS Testing
      • Drinking Water & Wastewater Testing
      • Soil, Sediment, Biota Testing
      • All Environmental
    • Food & Beverage
      • Food Quality
      • Food Safety
      • All Food & Beverage
    • Forensics
      • Forensics Toxicology
      • All Forensics
    • Pharmaceutical & Biopharma
  • Product Library
    • Gas Chromatography Products
      • GC Columns
      • Ferrules, Fittings, Connectors
      • Inlet Supplies
      • Instrument Supplies & Tools
      • Detector Supplies
      • Tubing & Regulators
      • Gas Purification & Generators
      • All Gas Chromatography Products
    • Liquid Chromatography Products
      • LC Columns
      • LC-MS Supplies
      • LC Autosampler Supplies
      • Mobile Phase Management
      • LC Detector Supplies
      • LC Tubing & Fittings
      • LC Pump Supplies
      • Tools & Organization
      • All Liquid Chromatography Products
    • Reference Standard Products
      • Liquid Reference Standards
      • Gas Standards & Accessories
      • All Reference Standard Products
    • Sample Preparation Products
      • QuEChERS Products
      • In-Line Sample Preparation (ILSP)
      • SPE & SPLE
      • SPME
      • ASE Extraction
      • Vials & Accessories
      • Coated Blade Spray
      • All Sample Preparation Products
    • Air & Gas Sampling Products
      • Canisters & Accessories
      • Sample Cylinders & Accessories
      • Gas Sampling Bags & Accessories
      • Gas Standards & Accessories
      • Personal Air Samplers & Accessories
      • Air Sampling Bottles & Valves
      • All Air & Gas Sampling Products
    • Custom Product Builders
  • Education & Training
    • Air Sampling
    • Gas Chromatography (GC)
    • GCxGC
    • Headspace
    • HILIC
    • Injection Techniques
    • Liquid Chromatography
    • Low-Pressure GC (LPGC)
    • Mass Spectrometry (MS)
    • MS/MS
    • QuEChERS
    • Solid-Phase Extraction (SPE)
    • Solid-Phase Microextraction (SPME)
  • Tools
    • EZ Chromatogram Modellers
    • Chromatogram Library
    • Calculators
  • Resources
    • Articles
    • Videos
    • Blogs
    • Application Notes
    • External Publications
  • Our Company
    • About Us
    • Press Releases & News
    • Events
    • Careers
Explore Product Catalog
SDS & COA Search
  • wpml-ls-flagEnglish
    • wpml-ls-flagFrançais
    • wpml-ls-flagDeutsch
    • wpml-ls-flagItaliano
    • wpml-ls-flag日本語
    • wpml-ls-flag简体中文
    • wpml-ls-flagEspañol
Contact US
Blogs

What impurities are hiding in your monocyclic aromatic solvents?

ByAudrey Crater December 29, 2019December 31, 2025

As we approach the end of the year we are indulging in a bit of nostalgia and most experts agree that reminiscing about the past is a good thing1. It makes us more optimistic and generous. Researchers also noticed that…

Read More What impurities are hiding in your monocyclic aromatic solvents?Continue

Blogs

My fitting nut has broken off in the end of my LC column. What to do?

ByAudrey Crater September 5, 2019December 26, 2025

If excessive force is applied at an angle to a fitting or column connector, the ferrule could become stuck in the column end fitting. Likewise, a PEEK connector, column nut or plug can also break and leave part of it…

Read More My fitting nut has broken off in the end of my LC column. What to do?Continue

Blogs

Pesticides are like Siblings – some get along well and some don’t – No. . .Really?

ByAudrey Crater May 1, 2019January 28, 2026

My colleague, Joe Konschnik and I have been asked by many food chemists out there about how much they can trust their pesticides mixes after they combine them into one single larger mixture for calibrating their instrument, or monitoring the…

Read More Pesticides are like Siblings – some get along well and some don’t – No. . .Really?Continue

Blogs

GC compounds – poor peak shapes and missing peaks

ByAudrey Crater January 14, 2018December 26, 2025

One of the most common questions I am asked by customers is “Why is my peak shape so poor?” Another is “I do not see a peak for my compound, what should I do?” Sometimes they are developing a new…

Read More GC compounds – poor peak shapes and missing peaksContinue

Blogs

Simple Analysis of Bile Acids by GC-MS

ByAudrey Crater June 30, 2016December 26, 2025

Bile acids are a group of steroidal acids with carboxyl and hydroxyl groups on the side. They are the major metabolic products of cholesterol. Bile acids play important roles as biomarkers for early diagnosis and therapeutic monitoring of many diseases,…

Read More Simple Analysis of Bile Acids by GC-MSContinue

Blogs

High Source Temperatures and Meeting EPA Tuning Criteria

ByAudrey Crater October 15, 2015December 31, 2025

My first blog here at Restek was a demonstration of how increasing the source temperature could improve the raw response of 2,4-dinitrophenol while maintaining the relative response. Four years later I’m here with the promised follow-up on the elevated source…

Read More High Source Temperatures and Meeting EPA Tuning CriteriaContinue

Blogs

Several things you may not know about our Super-Clean Gas Filters

ByAudrey Crater October 8, 2015December 26, 2025

Recently one of the designers of the Super-Clean Gas Filters spent some time with technical service and we were able to ask him a few common questions we get asked by customers. I thought I would share this information with…

Read More Several things you may not know about our Super-Clean Gas FiltersContinue

Blogs

It’s All in the Split Vent Trap

ByAudrey Crater June 7, 2015December 26, 2025

Recently I came across a situation where I wanted to make a series of constant flow GC-FID runs, during which, the inlet pressure would increase from 2 to 6 PSI over the temperature program. I also wanted to use split…

Read More It’s All in the Split Vent TrapContinue

Blogs

Peak Capacity in Capillary GC

ByAudrey Crater December 7, 2014December 26, 2025

Peak Capacity in capillary gas chromatography is different than sample loading capacity, which is something I’ve posted on multiple times recently in ChromaBLOGraphy. Peak capacity is simply the number of theoretical peaks that can “fit” inside a chromatogram under some…

Read More Peak Capacity in Capillary GCContinue

Blogs

Need help finding the correct ferrule to install your GC column? Part 1: Agilent GC ferrules

ByAudrey Crater November 20, 2014December 26, 2025

You’re ready to install a column into your GC and realize you do not have ferrules to do the job. But which ferrule do you choose? The parameters to consider when choosing the correct ferrule are instrument make and model,…

Read More Need help finding the correct ferrule to install your GC column? Part 1: Agilent GC ferrulesContinue

Page navigation

Previous PagePrevious 1 … 5 6 7 8 Next PageNext

Connect With Restek

Restek on LinkedIn
Restek on Facebook
Restek on Instagram
Restek on Youtube

Sign up for news, tips & more

Company Info

About Us

News

Media Kit

Events

Careers

About Us

News

Media Kit

Events

Careers

Help & Support

Website Help & Support

Contact Us

Find Your Sales Rep

Find Your Distributor

Website Help & Support

Contact Us

Find Your Sales Rep

Find Your Distributor

Quick Resources

Resource Hub

EZ suite

ISO Quality Credentials

Patents & Trademarks

SDS, COA, & Data Pack Search

Resource Hub

EZ suite

ISO Quality Credentials

Patents & Trademarks

SDS, COA, & Data Pack Search

Orders

Custom Products

My Account

Returns & Warranties

Custom Products

My Account

Returns & Warranties

Website Terms & Conditions

Terms & Conditions of Sale

Privacy Policy

Modern Slavery Statement

Copyright © 2026 Restek Corporation. All rights reserved.

Facebook LinkedIn