Skip to content
Language Selector Globe Icon

Select Language:

  • wpml-ls-flagEnglish
    • wpml-ls-flagFrançais
    • wpml-ls-flagDeutsch
    • wpml-ls-flagItaliano
    • wpml-ls-flag日本語
    • wpml-ls-flag简体中文
    • wpml-ls-flagEspañol
  • SDS & COA Search
  • Contact Us
Restek Corporation logo and link to discover.restek.com home page
  • Industries & Applications

      Browse By Applications

      • Cannabis
      • Medical or Recreational Cannabis
      • Hemp & Hallucinogens
      • Chemical Production
      • Clinical
      • Clinical Diagnostics
      • Clinical Research
      • Clinical Toxicology
      • Energy
      • Refining
      • Fuel Production
      • Hydrocarbon Gases
      • Environmental
      • Air Monitoring
      • Industrial Hygiene
      • PFAS Testing
      • Drinking Water & Wastewater Testing
      • Soil, Sediment, Biota Testing
      • Food & Beverage
      • Food Quality
      • Food Safety
      • Forensics
      • Forensics Toxicology
      • Pharmaceutical & Biopharma

      Chromatogram Library

      Browse our library of hundreds of GC and LC chromatograms.

      Search Now
  • Product Library

      Browse By Product

      • Gas Chromatography Products
      • GC Columns
      • Ferrules, Fittings, Connectors
      • Inlet Supplies
      • Instrument Supplies & Tools
      • Detector Supplies
      • Tubing & Regulators
      • Gas Purification & Generators
      • Liquid Chromatography Products
      • LC Columns
      • LC-MS Supplies
      • LC Autosampler Supplies
      • Mobile Phase Management
      • LC Detector Supplies
      • LC Tubing & Fittings
      • LC Pump Supplies
      • Tools & Organization
      • Reference Standard Products
      • Liquid Reference Standards
      • Gas Standards & Accessories
      • Sample Preparation Products
      • QuEChERS Products
      • In-Line Sample Preparation (ILSP)
      • SPE & SPLE
      • SPME
      • ASE Extraction
      • Vials & Accessories
      • Coated Blade Spray
      • Air & Gas Sampling Products
      • Canisters & Accessories
      • Sample Cylinders & Accessories
      • Gas Sampling Bags & Accessories
      • Gas Standards & Accessories
      • Personal Air Samplers & Accessories
      • Air Sampling Bottles & Valves
      • Custom Product Builders

      Chromatogram Library

      Browse our library of hundreds of GC and LC chromatograms.

      Search Now
  • Education & Training

      Browse By Topic

      • Air Sampling
      • Gas Chromatography (GC)
      • GCxGC
      • Headspace
      • HILIC
      • Injection Techniques
      • Liquid Chromatography
      • Low-Pressure GC (LPGC)
      • Mass Spectrometry (MS)
      • MS/MS
      • QuEChERS
      • Solid-Phase Extraction (SPE)
      • Solid-Phase Microextraction (SPME)

      Chromatography on demand!

      Browse our library of expert videos on troubleshooting, method development and more.

      Watch Now
  • Tools

      Browse Tools & Calculators

      • EZ Chromatogram Modellers
      • Chromatogram Library
      A magnifying glass highlighting a reference standard, with additional
reference standards in the background.

      Find Reference Standards Fast

      Access the NEW Reference Standards Finder to search, filter, and download a list of matched standards in minutes.

      Start Your Search

      Develop Methods in Seconds

      Model and optimize chromatograms in seconds with our Pro EZGC & EZLC Chromatogram Modelers

      Try them now!
  • Resources

      Browse Resources

      • Application Notes
      • Articles
      • Blogs
      • External Publications
      • Frequently Asked Questions (FAQ)
      • Videos

      Develop Methods in Minutes

      Free Chromatogram Modeling & Optimization Tools

      Try them now!

      PFAS Analysis Resources

      Method guides and products for PFAS analysis

      View Resources
  • Our Company

      Learn More About Restek

      • About Us
      • Press Releases & News
      • Events
      • Careers

      Are you ownership material?

      At Restek, you don’t just work here—you own it. We’re independent, innovative, and passionate about helping people succeed. Join our team of employee-owners and grow with us.

      Browse Openings Find Your Fit
  • Explore Product Catalog
Restek Corporation logo
  • Contact Us
Explore Product Catalog
Restek Corporation logo
  • Industries & Applications
    • Cannabis
      • Medical or Recreational Cannabis
      • Hemp & Hallucinogens
      • All Cannabis
    • Chemical Production
    • Clinical
      • Clinical Diagnostics
      • Clinical Research
      • Clinical Toxicology
      • All Clinical
    • Energy
      • Refining
      • Fuel Production
      • Hydrocarbon Gases
      • All Energy
    • Environmental
      • Air Monitoring
      • Industrial Hygiene
      • PFAS Testing
      • Drinking Water & Wastewater Testing
      • Soil, Sediment, Biota Testing
      • All Environmental
    • Food & Beverage
      • Food Quality
      • Food Safety
      • All Food & Beverage
    • Forensics
      • Forensics Toxicology
      • All Forensics
    • Pharmaceutical & Biopharma
  • Product Library
    • Gas Chromatography Products
      • GC Columns
      • Ferrules, Fittings, Connectors
      • Inlet Supplies
      • Instrument Supplies & Tools
      • Detector Supplies
      • Tubing & Regulators
      • Gas Purification & Generators
      • All Gas Chromatography Products
    • Liquid Chromatography Products
      • LC Columns
      • LC-MS Supplies
      • LC Autosampler Supplies
      • Mobile Phase Management
      • LC Detector Supplies
      • LC Tubing & Fittings
      • LC Pump Supplies
      • Tools & Organization
      • All Liquid Chromatography Products
    • Reference Standard Products
      • Liquid Reference Standards
      • Gas Standards & Accessories
      • All Reference Standard Products
    • Sample Preparation Products
      • QuEChERS Products
      • In-Line Sample Preparation (ILSP)
      • SPE & SPLE
      • SPME
      • ASE Extraction
      • Vials & Accessories
      • Coated Blade Spray
      • All Sample Preparation Products
    • Air & Gas Sampling Products
      • Canisters & Accessories
      • Sample Cylinders & Accessories
      • Gas Sampling Bags & Accessories
      • Gas Standards & Accessories
      • Personal Air Samplers & Accessories
      • Air Sampling Bottles & Valves
      • All Air & Gas Sampling Products
    • Custom Product Builders
  • Education & Training
    • Air Sampling
    • Gas Chromatography (GC)
    • GCxGC
    • Headspace
    • HILIC
    • Injection Techniques
    • Liquid Chromatography
    • Low-Pressure GC (LPGC)
    • Mass Spectrometry (MS)
    • MS/MS
    • QuEChERS
    • Solid-Phase Extraction (SPE)
    • Solid-Phase Microextraction (SPME)
  • Tools
    • EZ Chromatogram Modellers
    • Chromatogram Library
    • Calculators
  • Resources
    • Articles
    • Videos
    • Blogs
    • Application Notes
    • External Publications
  • Our Company
    • About Us
    • Press Releases & News
    • Events
    • Careers
Explore Product Catalog
SDS & COA Search
  • wpml-ls-flagEnglish
    • wpml-ls-flagFrançais
    • wpml-ls-flagDeutsch
    • wpml-ls-flagItaliano
    • wpml-ls-flag日本語
    • wpml-ls-flag简体中文
    • wpml-ls-flagEspañol
Contact US
Blogs

Annual Replacement of Cartridge Gas Filters

BySaVanna Cano July 17, 2018May 26, 2026

A significant number of instrument and column complaints are carrier gas related, which could be caused by breakthrough from filters that are not replaced in time. The possible consequences of a filter breakthrough are: Gas distribution system behind the filter…

Read More Annual Replacement of Cartridge Gas FiltersContinue

Blogs

Is it OK to use THF (tetrahydrofuran) on my HPLC?

BySaVanna Cano April 27, 2016December 17, 2025

Well, it might be. In the early days of HPLC, THF was commonly used as a mobile phase solvent. It has eluting strength similar to acetonitrile, but just slightly stronger. Since it technically is an ether and is very miscible…

Read More Is it OK to use THF (tetrahydrofuran) on my HPLC?Continue

Blogs

QuEChERS – Where to start?

BySaVanna Cano January 23, 2015January 8, 2026

Enjoy the tip!*I am often asked for QuEChERS product recommendations. Usually the request is something like, “I need to test pesticides in _____” and that blank can be just about anything…sometimes not even food. Unless it is something I have…

Read More QuEChERS – Where to start?Continue

Blogs

Are your ghost peaks coming from the GC column, or something else?

BySaVanna Cano January 22, 2015December 30, 2025

  This is a common GC troubleshooting question. Since determining the source of the ghost (contamination) peaks can be difficult, I decided to write this post to (hopefully) help our customers. . GC column carryover When I operated an instrument…

Read More Are your ghost peaks coming from the GC column, or something else?Continue

Blogs

Troubleshooting GC Syringe Issues

BySaVanna Cano October 31, 2012December 17, 2025

I think we all have experienced various syringe issues at one time or another, and of course, problems seem to occur at the worst times. Hopefully this post will help you quickly correct two of the most common issues we…

Read More Troubleshooting GC Syringe IssuesContinue

Blogs

How to choose the correct GC column – Part 3

BySaVanna Cano August 6, 2012May 26, 2026

In this post, I will explain how one can use column capacity (along with detector selection) to help narrow down GC column choices even further. Before reading this post, I suggest you review Parts 1 & 2, which can be…

Read More How to choose the correct GC column – Part 3Continue

Blogs

How to choose the correct GC column – Part 1

BySaVanna Cano July 19, 2012May 26, 2026

A month or so ago I gave a short training session to a few beginners on how to go about choosing a GC column. After all, there are thousands of Restek column catalog numbers to choose from (not to mention…

Read More How to choose the correct GC column – Part 1Continue

Blogs

I need a fitting, but which one?

BySaVanna Cano April 12, 2012May 27, 2026

We (tech service) get calls all the time about fittings, especially the ones we sell which are manufactured by Swagelok and Valco. It seems like customers are either very familiar with fittings, or they know virtually nothing about them….

Read More I need a fitting, but which one?Continue

Page navigation

Previous PagePrevious 1 2

Connect With Restek

Restek on LinkedIn
Restek on Facebook
Restek on Instagram
Restek on Youtube

Sign up for news, tips & more

Company Info

About Us

News

Media Kit

Events

Careers

About Us

News

Media Kit

Events

Careers

Help & Support

Website Help & Support

Contact Us

Find Your Sales Rep

Find Your Distributor

Website Help & Support

Contact Us

Find Your Sales Rep

Find Your Distributor

Quick Resources

Resource Hub

EZ suite

ISO Quality Credentials

Patents & Trademarks

SDS, COA, & Data Pack Search

Resource Hub

EZ suite

ISO Quality Credentials

Patents & Trademarks

SDS, COA, & Data Pack Search

Orders

Custom Products

My Account

Returns & Warranties

Custom Products

My Account

Returns & Warranties

Website Terms & Conditions

Terms & Conditions of Sale

Privacy Policy

Modern Slavery Statement

Copyright © 2026 Restek Corporation. All rights reserved.

Facebook LinkedIn