{"id":2824,"date":"2025-07-30T17:33:28","date_gmt":"2025-07-30T17:33:28","guid":{"rendered":"https:\/\/discover.restek.com\/?p=2824"},"modified":"2026-08-11T17:19:46","modified_gmt":"2026-08-11T17:19:46","slug":"how-do-i-select-the-most-appropriate-treatment-for-my-application","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/faq\/gnot5193\/how-do-i-select-the-most-appropriate-treatment-for-my-application","title":{"rendered":"How do I select the most appropriate treatment for my application?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The following definitions explain the various treatments currently available and their recommended applications:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Siltek\u00a0<\/strong>Provides the ultimate passivation of treated surfaces, from glass to high nickel alloys of steel.<\/li>\n\n\n\n<li><strong>Silcosteel<\/strong>\u00a0A general purpose passivation layer for steel and stainless steel.<\/li>\n\n\n\n<li><strong>Silcosteel-CR<\/strong>\u00a0A corrosion resistant layer that increases the lifetime of system components in environments containing hydrochloric, nitric, or sulfuric acid.<\/li>\n\n\n\n<li><strong>Sulfinert<\/strong>\u00a0A required treatment for metal components used in analyzing for parts-per-billion levels of organo-sulfur compounds.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The following definitions explain the various treatments currently available and their recommended applications:<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[2689],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-2824","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-surface-treatments"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2689,"label":"FAQ: Surface Treatments"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2689,"name":"FAQ: Surface Treatments","slug":"faq-surface-treatments","term_group":0,"term_taxonomy_id":2689,"taxonomy":"post_tag","description":"Browse frequently asked questions for surface treatments.","parent":0,"count":32,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2824","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=2824"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2824\/revisions"}],"predecessor-version":[{"id":70762,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2824\/revisions\/70762"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=2824"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=2824"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=2824"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=2824"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=2824"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=2824"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=2824"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=2824"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=2824"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}