{"id":2986,"date":"2025-07-30T19:45:21","date_gmt":"2025-07-30T19:45:21","guid":{"rendered":"https:\/\/discover.restek.com\/?p=2986"},"modified":"2026-08-11T17:38:20","modified_gmt":"2026-08-11T17:38:20","slug":"where-can-i-find-a-quechers-method-for-my-application","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/faq\/gnot5164\/where-can-i-find-a-quechers-method-for-my-application","title":{"rendered":"Where can I find a\u00a0QuEChERS\u00a0method for my application?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">QuEChERS, which stands for \u201cQuick, Easy, Cheap, Effective, Rugged, and Safe,\u201d is an increasingly popular approach to sample preparation for multiresidue pesticides analysis of a variety of food matrices. It is simpler and more streamlined than traditional liquid-liquid extractions and even easier than SPE. Three simple steps are involved with all QuEChERS methods: sample homogenization, extraction, and cleanup using\u00a0<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\">dSPE tubes<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">QuEChERS sample preparation for many analyses can be done by using the\u00a0<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\">Original Unbuffered Method<\/a>, which is the simplest procedure. Additionally, several buffered methods exist, which can improve recoveries for pH-sensitive pesticides. The most widely adopted buffered methods are\u00a0<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\">EN 15662<\/a>,\u00a0<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\">Mini-Multiresidue<\/a>, and\u00a0<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/803-01-005.pdf\">AOAC 2007.01<\/a>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Download Restek\u2019s\u00a0<a href=\"https:\/\/discover.restek.com\/articles\/FFSS1183\/quechers-made-even-easier\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/articles\/FFSS1183\/quechers-made-even-easier\/\">QuEChERS guide<\/a>\u00a0for an illustration of method steps, example applications, and a selection guide that shows exactly which dSPE tubes and sorbents are needed for each of the primary QuEChERS methods, including dSPE tubes for generic or universal use. In addition, validation and proficiency data for the QuEChERS method are available for a wide variety of pesticides in several common food matrices at\u00a0<a href=\"https:\/\/www.quechers.eu\/\" target=\"_blank\" rel=\"noopener\">www.quechers.eu<\/a>. Restek&#8217;s\u00a0<a href=\"https:\/\/discover.restek.com\/category\/blogs\/\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/category\/blogs\/\">ChromaBLOGraphy<\/a>\u00a0is also a good source for a variety of QuEChERS applications. Use &#8220;QuEChERS&#8221; as a keyword to search for relevant blog articles.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>QuEChERS, which stands for \u201cQuick, Easy, Cheap, Effective, Rugged, and Safe,\u201d is an increasingly popular approach to sample preparation for multiresidue pesticides analysis of a variety of food matrices. It is simpler and more streamlined than traditional liquid-liquid extractions and even easier than SPE. Three simple steps are involved with all QuEChERS methods: sample homogenization,&#8230;<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[2711,2688],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-2986","post","type-post","status-publish","format-standard","hentry","category-faq","tag-faq-quechers","tag-faq-sample-preparation"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"post_tag":[{"value":2711,"label":"FAQ: QuEChERS"},{"value":2688,"label":"FAQ: Sample Preparation"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":[{"term_id":2711,"name":"FAQ: QuEChERS","slug":"faq-quechers","term_group":0,"term_taxonomy_id":2711,"taxonomy":"post_tag","description":"Browse frequently asked questions for QuEChERS products.","parent":0,"count":2,"filter":"raw"},{"term_id":2688,"name":"FAQ: Sample Preparation","slug":"faq-sample-preparation","term_group":0,"term_taxonomy_id":2688,"taxonomy":"post_tag","description":"Browse frequently asked questions for sample preparation products.","parent":0,"count":53,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2986","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=2986"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2986\/revisions"}],"predecessor-version":[{"id":79717,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/2986\/revisions\/79717"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=2986"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=2986"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=2986"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=2986"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=2986"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=2986"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=2986"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=2986"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=2986"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}