{"id":39930,"date":"2020-10-27T14:30:00","date_gmt":"2020-10-27T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/solvent-compatibility-chart\/"},"modified":"2026-01-28T16:00:58","modified_gmt":"2026-01-28T16:00:58","slug":"solvent-compatibility-chart","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/faq\/gnot2857\/solvent-compatibility-chart","title":{"rendered":"Solvent Compatibility Chart for the Q-sep Bottle Top Solvent Dispenser"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Legend Key:<\/strong> A = Good resistance, B = Acceptable with limitations, C = Not recommended<br>1 = Possible crystallization, blockage, or possible coat peeling<br>2 = Swelling of plunger, possible peeling<br>3 = Acid vapors (better resistance with lower concentration)<br>4 = Risk of damage, softening or discoloration of external parts through vapors<br>5 = Chemical degradation of glass parts (plunger\/barrel)<\/td><td><\/td><\/tr><tr><td><strong>Chemical Name<\/strong><\/td><td><strong>Compatibility Code<\/strong><\/td><\/tr><tr><td>Acetaldehyde (ethanal)<\/td><td>A<\/td><\/tr><tr><td>Acetic acid, 96%<\/td><td>A<\/td><\/tr><tr><td>Acetic acid, 100% (glacial)<\/td><td>B\/4<\/td><\/tr><tr><td>Acetic anhydride<\/td><td>B\/4<\/td><\/tr><tr><td>Acetone (propanone)<\/td><td>B\/4<\/td><\/tr><tr><td>Acetonitrile (MECN)<\/td><td>B\/4<\/td><\/tr><tr><td>Acetophenone<\/td><td>B\/4<\/td><\/tr><tr><td>Acetyl chloride<\/td><td>B\/4<\/td><\/tr><tr><td>Acetylacetone<\/td><td>A<\/td><\/tr><tr><td>Acrylic acid<\/td><td>A<\/td><\/tr><tr><td>Acrylonitrile<\/td><td>B\/4<\/td><\/tr><tr><td>Adipic acid<\/td><td>C\/1<\/td><\/tr><tr><td>Allyl alcohol<\/td><td>A<\/td><\/tr><tr><td>Aluminum chloride<\/td><td>C\/1<\/td><\/tr><tr><td>Amino acids<\/td><td>C\/1<\/td><\/tr><tr><td>Ammonia, 20%<\/td><td>B\/4<\/td><\/tr><tr><td>Ammonia, 20\u201330%<\/td><td>B\/4<\/td><\/tr><tr><td>Ammonium chloride<\/td><td>C\/1<\/td><\/tr><tr><td>Ammonium fluoride<\/td><td>C\/1<\/td><\/tr><tr><td>Ammonium molybdate<\/td><td>C\/1<\/td><\/tr><tr><td>Ammonium sulfate<\/td><td>C\/1<\/td><\/tr><tr><td>Amyl alcohol (pentanol)<\/td><td>A<\/td><\/tr><tr><td>Amyl chloride (chloropentane)<\/td><td>B\/4<\/td><\/tr><tr><td>Aniline<\/td><td>A<\/td><\/tr><tr><td>Ascorbic acid<\/td><td>C1<\/td><\/tr><tr><td>n-Amyl acetate<\/td><td>B\/4<\/td><\/tr><tr><td>Barium chloride<\/td><td>C1<\/td><\/tr><tr><td>Benzaldehyde<\/td><td>A<\/td><\/tr><tr><td>Benzene<\/td><td>B\/4<\/td><\/tr><tr><td>Benzine<\/td><td>A<\/td><\/tr><tr><td>Benzoyl chloride<\/td><td>B\/4<\/td><\/tr><tr><td>Benzyl alcohol<\/td><td>A<\/td><\/tr><tr><td>Benzyl chloride<\/td><td>B\/4<\/td><\/tr><tr><td>Bis(2-ethylhexyl) phthalate<\/td><td>B\/4<\/td><\/tr><tr><td>Boric acid, 10%<\/td><td>B\/1<\/td><\/tr><tr><td>Bromine<\/td><td>C\/4<\/td><\/tr><tr><td>Bromobenzene<\/td><td>B\/4<\/td><\/tr><tr><td>Bromonaphthalene<\/td><td>A<\/td><\/tr><tr><td>Butanediol<\/td><td>B\/1<\/td><\/tr><tr><td>Butanol<\/td><td>A<\/td><\/tr><tr><td>Butanone (MEK)<\/td><td>B\/4<\/td><\/tr><tr><td>Butyl acetate<\/td><td>B\/4<\/td><\/tr><tr><td>Butyl methyl ether<\/td><td>B\/4<\/td><\/tr><tr><td>Butylamine<\/td><td>B\/4<\/td><\/tr><tr><td>Butyric acid<\/td><td>B\/4<\/td><\/tr><tr><td>Calcium carbonate<\/td><td>C\/1<\/td><\/tr><tr><td>Calcium chloride<\/td><td>C\/1<\/td><\/tr><tr><td>Calcium hydroxide<\/td><td>C\/1<\/td><\/tr><tr><td>Calcium hypochlorite<\/td><td>C\/1<\/td><\/tr><tr><td>Carbon disulfide<\/td><td>B\/4<\/td><\/tr><tr><td>Carbon tetrachloride<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorine dioxide<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorine water<\/td><td>B\/4<\/td><\/tr><tr><td>Chloro naphthalene<\/td><td>B\/4<\/td><\/tr><tr><td>Chloroacetaldehyde, 45%<\/td><td>B\/1<\/td><\/tr><tr><td>Chloroacetic acid<\/td><td>B\/1<\/td><\/tr><tr><td>Chloroacetone<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorobenzene<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorobutane<\/td><td>B\/4<\/td><\/tr><tr><td>Chloroethanol<\/td><td>B\/4<\/td><\/tr><tr><td>Chloroform<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorosulfonic acid<\/td><td>B\/4<\/td><\/tr><tr><td>Chlorosulfuric acid, 100%<\/td><td>B\/3\/4<\/td><\/tr><tr><td>Chromic acid<\/td><td>B\/3\/4<\/td><\/tr><tr><td>Chromosulfuric acid, 100%<\/td><td>C\/1\/3\/4<\/td><\/tr><tr><td>Citric acid<\/td><td>B\/1<\/td><\/tr><tr><td>Copper fluoride<\/td><td>C\/1<\/td><\/tr><tr><td>Copper sulfate<\/td><td>C\/1<\/td><\/tr><tr><td>Cresol<\/td><td>B\/1<\/td><\/tr><tr><td>Cumene (isopropylbenzene)<\/td><td>B\/4<\/td><\/tr><tr><td>Cyanoacrylate<\/td><td>C\/1<\/td><\/tr><tr><td>Cyclohexane<\/td><td>B\/4<\/td><\/tr><tr><td>Cyclohexanone<\/td><td>B\/4<\/td><\/tr><tr><td>Cyclopentane<\/td><td>B\/4<\/td><\/tr><tr><td>1,2-Diethylbenzene<\/td><td>B\/4<\/td><\/tr><tr><td>1,4-Dioxane (diethylene dioxide)<\/td><td>B\/4<\/td><\/tr><tr><td>1-Decanol<\/td><td>A<\/td><\/tr><tr><td>Decane<\/td><td>A<\/td><\/tr><tr><td>Di-(2-ethylhexyl) peroxydicarbonate<\/td><td>B\/4<\/td><\/tr><tr><td>Dibenzyl ether<\/td><td>B\/4<\/td><\/tr><tr><td>Dichloroacetic acid<\/td><td>A<\/td><\/tr><tr><td>Dichlorobenzene<\/td><td>A<\/td><\/tr><tr><td>Dichloroethane<\/td><td>A<\/td><\/tr><tr><td>Dichloroethylene<\/td><td>B\/4<\/td><\/tr><tr><td>Diesel oil (heating oil)<\/td><td>A<\/td><\/tr><tr><td>Diethanolamine<\/td><td>A<\/td><\/tr><tr><td>Diethylamine<\/td><td>B\/4<\/td><\/tr><tr><td>Diethylene glycol<\/td><td>A<\/td><\/tr><tr><td>Diethylether<\/td><td>B\/4<\/td><\/tr><tr><td>Dimethyl sulfoxide (DMSO)<\/td><td>B\/1\/4<\/td><\/tr><tr><td>Dimethylaniline<\/td><td>A<\/td><\/tr><tr><td>Dimethylformamide (DMF)<\/td><td>B\/4<\/td><\/tr><tr><td>Ethanol<\/td><td>A<\/td><\/tr><tr><td>Ethanolamine<\/td><td>B\/4<\/td><\/tr><tr><td>Ether<\/td><td>B\/4<\/td><\/tr><tr><td>Ethyl acetate<\/td><td>B\/4<\/td><\/tr><tr><td>Ethylbenzene<\/td><td>B\/4<\/td><\/tr><tr><td>Ethylene chloride<\/td><td>B\/4<\/td><\/tr><tr><td>Ethylene diamine<\/td><td>A<\/td><\/tr><tr><td>Ethylene glycol<\/td><td>A<\/td><\/tr><tr><td>Fluoroacetic acid<\/td><td>B\/1\/4<\/td><\/tr><tr><td>Formaldehyde (formalin)<\/td><td>A<\/td><\/tr><tr><td>Formamide<\/td><td>A<\/td><\/tr><tr><td>Formic acid<\/td><td>A<\/td><\/tr><tr><td>Gamma-butyrolactone<\/td><td>A<\/td><\/tr><tr><td>Gasoline<\/td><td>B\/4<\/td><\/tr><tr><td>Glycerin, &lt;40%<\/td><td>A<\/td><\/tr><tr><td>Glycolic acid, 50%<\/td><td>B\/1<\/td><\/tr><tr><td>Heating oil (diesel oil)<\/td><td>A<\/td><\/tr><tr><td>Heptane<\/td><td>A<\/td><\/tr><tr><td>Hexane<\/td><td>A<\/td><\/tr><tr><td>Hexanoic acid<\/td><td>B\/1<\/td><\/tr><tr><td>Hexanol<\/td><td>A<\/td><\/tr><tr><td>Hydriodic acid<\/td><td>B\/4<\/td><\/tr><tr><td>Hydrobromic acid<\/td><td>A<\/td><\/tr><tr><td>Hydrochloric acid (HCl), 20%<\/td><td>A<\/td><\/tr><tr><td>Hydrochloric acid (HCl), 37%<\/td><td>B\/3<\/td><\/tr><tr><td>Hydrofluoric acid (HF)<\/td><td>C\/5<\/td><\/tr><tr><td>Hydrogen peroxide<\/td><td>A<\/td><\/tr><tr><td>Iodine<\/td><td>C\/1<\/td><\/tr><tr><td>Iodine bromide<\/td><td>C\/4<\/td><\/tr><tr><td>Iodine chloride<\/td><td>C\/4<\/td><\/tr><tr><td>Isoamyl alcohol<\/td><td>A<\/td><\/tr><tr><td>Isobutanol<\/td><td>A<\/td><\/tr><tr><td>Isooctane<\/td><td>A<\/td><\/tr><tr><td>Isopropanol<\/td><td>A<\/td><\/tr><tr><td>Isopropyl ether<\/td><td>B\/4<\/td><\/tr><tr><td>Isopropylamide<\/td><td>B\/4<\/td><\/tr><tr><td>Lactic acid<\/td><td>C\/1<\/td><\/tr><tr><td>2-Methoxyethanol<\/td><td>A<\/td><\/tr><tr><td>Methanol<\/td><td>A<\/td><\/tr><tr><td>Methoxybenzene (anisole)<\/td><td>B\/4<\/td><\/tr><tr><td>Methyl benzoate<\/td><td>B\/1\/4<\/td><\/tr><tr><td>Methyl chloride (chloromethane)<\/td><td>B\/4<\/td><\/tr><tr><td>Methyl formate<\/td><td>A<\/td><\/tr><tr><td>Methyl iodide (iodomethane)<\/td><td>B\/4<\/td><\/tr><tr><td>Methyl methacrylate (MMA)<\/td><td>B\/4<\/td><\/tr><tr><td>Methyl propyl ketone (2-pentanone)<\/td><td>A<\/td><\/tr><tr><td>Methyl&nbsp;<em>tert<\/em>-butyl ether<\/td><td>B\/4<\/td><\/tr><tr><td>Methylene chloride (dichloromethane)<\/td><td>B\/4<\/td><\/tr><tr><td>Methylpentanone<\/td><td>A<\/td><\/tr><tr><td>Mineral oil (engine oil)<\/td><td>A<\/td><\/tr><tr><td>Monochloroacetic acid<\/td><td>B\/1<\/td><\/tr><tr><td>N-Butylamine<\/td><td>B\/4<\/td><\/tr><tr><td>Nitric acid, 100%<\/td><td>C\/3\/4<\/td><\/tr><tr><td>Nitric acid, 30\u201370%<\/td><td>B\/4<\/td><\/tr><tr><td>Nitric acid, &lt;30%<\/td><td>B\/4<\/td><\/tr><tr><td>Nitrobenzene<\/td><td>B\/4<\/td><\/tr><tr><td>Nitrohydrochloric acid (aqua regia)<\/td><td>B\/4<\/td><\/tr><tr><td>Nitromethane<\/td><td>B\/4<\/td><\/tr><tr><td>N-Methyl-2-pyrrolidone (NMP)<\/td><td>A<\/td><\/tr><tr><td>Octane<\/td><td>A<\/td><\/tr><tr><td>Octanol<\/td><td>A<\/td><\/tr><tr><td>Oil (vegetable, animal)<\/td><td>B\/4<\/td><\/tr><tr><td>Oil of turpentine<\/td><td>B\/4<\/td><\/tr><tr><td>Oleic acid<\/td><td>B\/1<\/td><\/tr><tr><td>Oxalic acid<\/td><td>C\/1<\/td><\/tr><tr><td>Pentane<\/td><td>B\/4<\/td><\/tr><tr><td>Peracetic acid<\/td><td>A<\/td><\/tr><tr><td>Perchloric acid, 100%<\/td><td>B\/4<\/td><\/tr><tr><td>Perchloric acid, diluted<\/td><td>A<\/td><\/tr><tr><td>Perchloroethylene<\/td><td>B\/4<\/td><\/tr><tr><td>Petroleum<\/td><td>B\/4<\/td><\/tr><tr><td>Petroleum ether\/spirit<\/td><td>B\/4<\/td><\/tr><tr><td>Phenol<\/td><td>A<\/td><\/tr><tr><td>Phenylethanol<\/td><td>B\/4<\/td><\/tr><tr><td>Phenylhydrazine<\/td><td>B\/1\/4<\/td><\/tr><tr><td>Phosphoric acid, 100%<\/td><td>A<\/td><\/tr><tr><td>Phosphoric acid, 85%<\/td><td>A<\/td><\/tr><tr><td>Piperidine<\/td><td>B\/4<\/td><\/tr><tr><td>Potassium chloride<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium dichromate<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium hydroxide<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium iodide<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium permanganate<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium peroxydisulfate (persulfate)<\/td><td>C\/1<\/td><\/tr><tr><td>Potassium sulfate<\/td><td>C\/1<\/td><\/tr><tr><td>Propionic acid (propanoic acid)<\/td><td>A<\/td><\/tr><tr><td>Propylene glycol (propane-1,2,-diol)<\/td><td>A<\/td><\/tr><tr><td>Propylene oxide<\/td><td>A<\/td><\/tr><tr><td>Pyric acid (trinitrophenol)<\/td><td>B\/4<\/td><\/tr><tr><td>Pyridine<\/td><td>B\/4<\/td><\/tr><tr><td>Pyruvic acid<\/td><td>B\/1<\/td><\/tr><tr><td>Resorcin<\/td><td>C\/1<\/td><\/tr><tr><td>Salicylaldehyde<\/td><td>A<\/td><\/tr><tr><td>Scintillation fluid<\/td><td>A<\/td><\/tr><tr><td>Silver acetate<\/td><td>C\/1<\/td><\/tr><tr><td>Silver nitrate<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium acetate<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium chloride<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium dichromate<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium fluoride<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium hydroxide, 30%<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium hypochlorite<\/td><td>C\/1<\/td><\/tr><tr><td>Sodium thiosulfate<\/td><td>C\/1<\/td><\/tr><tr><td>Sulfonitric acid, 100%<\/td><td>B\/3\/4<\/td><\/tr><tr><td>Sulfur dioxide<\/td><td>B\/4<\/td><\/tr><tr><td>Sulfuric acid, 100%<\/td><td>B\/4<\/td><\/tr><tr><td>1,1,2-Trichlorotrifluoroethane<\/td><td>B\/4<\/td><\/tr><tr><td>Tartaric acid<\/td><td>C\/1<\/td><\/tr><tr><td>Tetrachlorethylene<\/td><td>B\/4<\/td><\/tr><tr><td>Tetrahydrofuran (THF)<\/td><td>B\/4<\/td><\/tr><tr><td>Tetramethylammonium hydroxide<\/td><td>C\/1\/4<\/td><\/tr><tr><td>Toluene<\/td><td>B\/4<\/td><\/tr><tr><td>Trichloroethylene<\/td><td>B\/4<\/td><\/tr><tr><td>Trichloroacetic acid<\/td><td>B\/1\/4<\/td><\/tr><tr><td>Trichlorobenzene<\/td><td>B\/4<\/td><\/tr><tr><td>Trichloroethane<\/td><td>B\/4<\/td><\/tr><tr><td>Trichloromethane (chloroform)<\/td><td>B\/4<\/td><\/tr><tr><td>Triethanolamine<\/td><td>A<\/td><\/tr><tr><td>Triethylene glycol<\/td><td>A<\/td><\/tr><tr><td>Trifluoroacetic anhydride (TFAA)<\/td><td>B\/4<\/td><\/tr><tr><td>Trifluoromethane (fluoroform)<\/td><td>B\/4<\/td><\/tr><tr><td>Urea<\/td><td>C1<\/td><\/tr><tr><td>Xylene<\/td><td>B\/4<\/td><\/tr><tr><td>Zinc chloride, 10%<\/td><td>C1<\/td><\/tr><tr><td>Zinc sulfate, 10%<\/td><td>C1<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Chemical Compatibility Chart for the Q-sep Bottle Top Solvent Dispenser<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[23],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[562],"product-library":[2372,2373,2375],"resource-technique":[],"ppma_author":[414],"class_list":["post-39930","post","type-post","status-publish","format-standard","hentry","category-faq","resource-type-chromatography-fundamentals","product-library-gas-chromatography-products","product-library-liquid-chromatography-products","product-library-sample-preparation-products"],"acf":[],"taxonomy_info":{"category":[{"value":23,"label":"FAQ"}],"resource-type":[{"value":562,"label":"Chromatography Fundamentals"}],"product-library":[{"value":2372,"label":"Gas Chromatography Products"},{"value":2373,"label":"Liquid Chromatography Products"},{"value":2375,"label":"Sample Preparation Products"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":23,"name":"FAQ","slug":"faq","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":309,"filter":"raw","cat_ID":23,"category_count":309,"category_description":"","cat_name":"FAQ","category_nicename":"faq","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/39930","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=39930"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/39930\/revisions"}],"predecessor-version":[{"id":85482,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/39930\/revisions\/85482"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=39930"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=39930"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=39930"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=39930"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=39930"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=39930"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=39930"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=39930"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=39930"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}