{"id":42383,"date":"2019-09-19T04:00:00","date_gmt":"2019-09-19T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/die-hilic-trennmethode-in-der-flussigkeitschromatografie-lc\/"},"modified":"2026-01-28T22:22:05","modified_gmt":"2026-01-28T22:22:05","slug":"die-hilic-trennmethode-in-der-flussigkeitschromatografie-lc","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3663-de\/die-hilic-trennmethode-in-der-flussigkeitschromatografie-lc","title":{"rendered":"Die HILIC-Trennmethode in der Fl\u00fcssigkeitschromatografie (LC)"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Understanding the HILIC Separation Method in LC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/f83U3zgWbPY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die HILIC-Chromatografie (\u201eHydrophilic interaction liquid chromatography\u201c) ist eine leistungsf\u00e4hige spezielle Form der Fl\u00fcssigkeitschromatografie (LC), bei der polare station\u00e4re Phasen und eine anf\u00e4ngliche mobile Phase mit hohem organischem Anteil zur Trennung polarer Analyte verwendet werden. In diesem Video erl\u00e4utern wir die Grundlagen der HILIC-Methode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\" data-type=\"post\" data-id=\"43644\">How to Avoid Common Problems with\u00a0HILIC\u00a0Methods<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\" data-type=\"post\" data-id=\"43822\">Simplify the Switch to HILIC with Raptor HILIC-Si Columns<\/a><br><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/search\/hilic-si\/_\/N-1673632971?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Raptor HILIC-Si LC Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In dieser Reihe von Restek-Tipps werden wir die Methodenentwicklung f\u00fcr HILIC-basierte LC-Methoden behandeln. Zun\u00e4chst wollen wir uns den Trennmechanismus der HILIC-Methode ansehen. Hierbei handelt es sich um eine Trennung unter Verwendung polarer station\u00e4rer Phasen. Da die station\u00e4re Phase polar ist, ist die HILIC-Methode gut geeignet zur Analyse von polaren Molek\u00fclen, die an typischen Umkehrphasen nur begrenzt oder gar nicht retardiert werden. Die mobilen Phasen sind den bei der Umkehrphasen-LC verwendeten Phasen vergleichbar. Bei der HILIC-Trennung ist der Anfangseluent jedoch eine mobile Phase mit hohem organischen Anteil, wobei auf der Oberfl\u00e4che der polaren station\u00e4ren Phase eine w\u00e4ssrige Schicht erzeugt wird.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Da die polaren Analyte in der w\u00e4ssrigen Schicht l\u00f6slich sind, k\u00f6nnen sie mit der polaren station\u00e4ren Phase in Wechselwirkung treten und auf mehrfache Weise retardiert werden, z. B. durch Wasserstoffbr\u00fcckenbindung, Dipol-Dipol-Wechselwirkungen und Ionenaustausch. Aufgrund der differentiellen Verteilung zwischen der station\u00e4ren Phase, der w\u00e4ssrigen Schicht und der mobilen Phase, kann das Gemisch der polaren Verbindungen dann selektiv von der HILIC-S\u00e4ule eluiert werden. Und weil die mobile Phase einen hohen Anteil des organischen L\u00f6semittels enth\u00e4lt, ist die Nachweisempfindlichkeit deutlich erh\u00f6ht, wenn ein Massenspektrometer als Detektor verwendet wird. Wenn Sie interessiert sind, es mal mit der HILIC-Analyse zu versuchen, geben wir Ihnen in den kommenden Videos einige Tipps, die Ihnen helfen k\u00f6nnen, Ihre eigenen HILIC-Methoden zu entwickeln.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Ihnen diese Videos gefallen, denken Sie bitte an die \u201eGef\u00e4llt mir\u201c-Angabe und teilen und abonnieren Sie sie. Sie k\u00f6nnen das nachstehende Kommentarfeld verwenden, um uns Ihre Ideen f\u00fcr k\u00fcnftige TechTipps mitzuteilen. Vielen Dank f\u00fcr Ihre Aufmerksamkeit und bis zum n\u00e4chsten Mal.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dieser Restek-Tipp ist Teil eins unserer Serie zum Verst\u00e4ndnis und zur Optimierung von HILIC-Trennungen.<\/p>\n","protected":false},"author":11,"featured_media":41313,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2499],"resource-technique":[2326,2355],"ppma_author":[414],"class_list":["post-42383","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-lc-saulen","resource-technique-flussigchromatografie","resource-technique-hilic-de"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"},{"value":2355,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3663-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":772,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42383"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42383\/revisions"}],"predecessor-version":[{"id":85784,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42383\/revisions\/85784"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41313"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42383"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42383"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42383"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42383"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42383"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42383"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42383"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42383"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}