{"id":42429,"date":"2018-04-24T04:00:00","date_gmt":"2018-04-24T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/choosing-the-right-exp-fitting\/"},"modified":"2026-06-17T19:49:10","modified_gmt":"2026-06-17T19:49:10","slug":"choosing-the-right-exp-fitting","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos\/gnav3565\/choosing-the-right-exp-fitting","title":{"rendered":"Choosing the Right EXP Fitting"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Choosing the Right EXP Fitting\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Q_8dBlymTqk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There are many different types of&nbsp;fittings for making connections with liquid chromatography. We recommend using EXP fittings when working with stainless steel tubing. They are reusable and available in a&nbsp;number of&nbsp;configurations,&nbsp;so you get exactly the type of connection you need&nbsp;throughout&nbsp;your&nbsp;system.&nbsp;We\u2019ll show you how to select the right one every time.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/gnss1774\/exp-and-exp2-fittings-reusable-fittings-for-easy-reliable-hplc-uhplc-connections\/\">EXP and EXP2 Fittings<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/730-20-003\/exp-fittings\/\">EXP Fitting Instruction Sheet<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/730-20-004\/exp2-fittings\/\">EXP2 Fitting Instruction Sheet<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1759\" target=\"_blank\" rel=\"noreferrer noopener\">EXP Reusable Fittings for HPLC &amp; UHPLC<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hi, everyone. Thanks for joining us for this Restek Tip. Our topic today is EXP fitting selection. Now, the EXP system is for stainless steel tubing,&nbsp;and it&#8217;s got several different types of nuts along with the PEEK and titanium hybrid ferrule. Now, the way the ferrule works is that the PEEK portion goes into your column port and makes the seal while the metal portion faces the nut so when tightened the ferrule securely grips the tubing without permanently attaching. So, it can be reused multiple times without compromising the seal.&nbsp;You have a few choices when it comes to the style of nut.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">First is the traditional hex&nbsp;head in&nbsp;three different lengths&nbsp;of the threaded shaft. This could be an all-purpose connection for a pump outlet to the mixer tubing or for the connection to the mixer itself. Next is the hand-tight fitting, which has a little bit of a larger head for better grip when you&#8217;re tightening by hand. You need to use this where you have a little extra space,&nbsp;like a connection from the pump to the mixer. Finally, there&#8217;s the EXP2 style, which is a slim head and comes with a nut driver, so you&#8217;re able to install the fitting in a space where it&#8217;s a little tight squeeze,&nbsp;like on a multiport valve.&nbsp;No matter which one of these fittings you choose, you&#8217;re ensured to have a reliable connection for your LC tubing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thanks for joining us, and watch for more tips from your friends at Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EXPerience how good liquid chromatography fittings can be! This Restek Tip brings the knowledge on EXP fittings and their many options for quick selection and quality connections.<\/p>\n","protected":false},"author":11,"featured_media":41010,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[567],"product-library":[2396,2373],"resource-technique":[2299],"ppma_author":[414],"class_list":["post-42429","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos","resource-type-selection-guides","product-library-lc-tubing-fittings","product-library-liquid-chromatography-products","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}],"resource-type":[{"value":567,"label":"Selection Guides"}],"product-library":[{"value":2396,"label":"LC Tubing &amp; Fittings"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3565-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":8,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42429"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42429\/revisions"}],"predecessor-version":[{"id":78655,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42429\/revisions\/78655"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41010"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42429"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42429"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42429"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42429"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42429"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42429"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}