{"id":42433,"date":"2019-10-01T04:00:00","date_gmt":"2019-10-01T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/konditionieren-ihres-lc-gerats-und-der-saule-fur-hilic\/"},"modified":"2026-01-28T22:25:45","modified_gmt":"2026-01-28T22:25:45","slug":"konditionieren-ihres-lc-gerats-und-der-saule-fur-hilic","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3575-de\/konditionieren-ihres-lc-gerats-und-der-saule-fur-hilic","title":{"rendered":"Konditionieren Ihres LC-Ger\u00e4ts und der S\u00e4ule f\u00fcr HILIC"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Conditioning Your LC Instrument and Column for HILIC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/znIAVFtVjOI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">HILIC steht f\u00fcr \u201eHydrophilic Interaction Liquid Chromatography\u201c und ist eine leistungsstarke spezielle Form der Fl\u00fcssigkeitschromatografie (LC), bei der polare station\u00e4re Phasen und eine anf\u00e4ngliche mobile Phase mit hohem organischem Anteil zur Trennung polarer Analyte verwendet werden. Aufgrund der \u00fcberwiegend organischen Anfangsbedingungen ist es wichtig, das Ger\u00e4t und die S\u00e4ule zu konditionieren, um optimale Performance zu erhalten. Wie das geht, zeigen wir in diesem Video.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\" data-type=\"post\" data-id=\"43644\">How to Avoid Common Problems with\u00a0HILIC\u00a0Methods<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\" data-type=\"post\" data-id=\"43822\">Simplify the Switch to HILIC with Raptor HILIC-Si Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/search\/hilic-si\/_\/N-1673632971?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">Raptor HILIC-Si S\u00e4ulen<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jetzt haben Sie also eine neue HILIC-S\u00e4ule und m\u00f6chten gern eine HILIC-Analyse entwickeln oder durchf\u00fchren. Was sollten Sie zuallererst tun?<br><br>Wie bereits f\u00fcr HILIC-basierte LC-Trennungen erl\u00e4utert, ist der Anfangseluent eine mobile Phase mit hohem organischen Anteil, wobei auf der Oberfl\u00e4che der polaren station\u00e4ren Phase eine w\u00e4ssrige Schicht vorliegt. Zwischen einzelnen L\u00e4ufen muss die S\u00e4ule konditioniert und dann wieder \u00e4quilibriert werden, um die Wasserschicht auf der Partikeloberfl\u00e4che wiederherzustellen. Wenn Sie erstmals eine neue HILIC-S\u00e4ule benutzen oder die Zusammensetzung der mobilen Phase \u00e4ndern m\u00f6chten, sollten Sie die S\u00e4ule mit wenigstens 50 Volumina der mobilen Phase durchsp\u00fclen. Au\u00dferdem sollten mindestens 10 Leerinjektionen mit dem kompletten Elutionsprogramm durchgef\u00fchrt werden, bevor Sie einen neuen Chargenlauf starten. Die \u00c4quilibrierungszeit zwischen einzelnen Injektionen k\u00f6nnte stark vom jeweiligen Analyten abh\u00e4ngig sein. Deshalb sollten Sie die Reproduzierbarkeit der Retentionszeiten beobachten, um so die zur erneuten \u00c4quilibrierung erforderliche Zeit zu bestimmen.<br><br>Au\u00dferdem sollten Sie nicht vergessen, dass neben der S\u00e4ule selbst auch Ihr LC-System f\u00fcr die HILIC-Analyse konditioniert werden muss. Wir wissen, dass LC-Ger\u00e4te normalerweise f\u00fcr LC-Analysen im Umkehrphasenbetrieb verwendet werden.<br>Bevor Sie auf die HILIC-Analyse umsteigen, vergessen Sie also bitte nicht, Ihr System mit einer mobilen Phase mit hohem organischem Anteil 30 bis 60 Minuten lang durchzusp\u00fclen.&nbsp;<br><br>Wenn Sie sowohl Ihre S\u00e4ule als auch Ihr System auf diese Weise f\u00fcr die HILIC-Analyse konditioniert haben, k\u00f6nnen Sie Ihre Arbeit in Angriff nehmen. Wenn Ihnen diese Videos gefallen, denken Sie bitte an die \u201eGef\u00e4llt mir\u201c-Angabe und teilen und abonnieren Sie sie. Sie k\u00f6nnen das nachstehende Kommentarfeld verwenden, um uns Ihre Ideen f\u00fcr k\u00fcnftige TechTipps mitzuteilen. Vielen Dank f\u00fcr Ihre Aufmerksamkeit und bis zum n\u00e4chsten Mal.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In diesem Restek-Tipp geht es um die Konditionierung Ihrer S\u00e4ule und Ihres Instruments f\u00fcr HILIC. Fl\u00fcssigchromatografie.<\/p>\n","protected":false},"author":11,"featured_media":41025,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2499],"resource-technique":[2326,2355],"ppma_author":[414],"class_list":["post-42433","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-lc-saulen","resource-technique-flussigchromatografie","resource-technique-hilic-de"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"},{"value":2355,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3575-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":772,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42433","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42433"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42433\/revisions"}],"predecessor-version":[{"id":85793,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42433\/revisions\/85793"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41025"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42433"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42433"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42433"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42433"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42433"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42433"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42433"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42433"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42433"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}