{"id":42437,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/konditionierung-von-gc-saulen\/"},"modified":"2026-01-28T22:26:08","modified_gmt":"2026-01-28T22:26:08","slug":"konditionierung-von-gc-saulen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3589-de\/konditionierung-von-gc-saulen","title":{"rendered":"Konditionierung von GC-S\u00e4ulen"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Column Conditioning\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/XFxCoVyyqEw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">GC-S\u00e4ulen bluten immer weniger, sogar wenn diese direkt aus der Verpackung eingebaut werden. &nbsp;&nbsp;<br>Dennoch empfehlen wir, eine neue GC-S\u00e4ule zu konditionieren &#8211; so k\u00f6nnen Sie die Leistung Ihrer GC-S\u00e4ule unter Ihren Gegebenheiten pr\u00fcfen.&nbsp;<br>Hierbei sollte auf ein leckfreies System und sauberes, trockenes sowie sauerstofffreies Tr\u00e4gergas geachtet werden.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnan1533\/how-to-condition-a-new-capillary-gc-column\" data-type=\"post\" data-id=\"43631\">How to Condition a New Capillary GC Column<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/20116\" target=\"_blank\" rel=\"noopener\">Ceramic Scoring Wafer<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/22654\" target=\"_blank\" rel=\"noopener\">Electronic Leak Detector and ProFLOW 6000 Flowmeter<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo zusammen, es ist mal wieder Zeit f\u00fcr einen neuen Tipp von Restek. Heute wollen wir \u00fcber die Konditionierung unserer GC-S\u00e4ule sprechen, ein einfaches Verfahren mit nur wenigen Schritten, das wir ab und zu durchf\u00fchren. Als erstes k\u00fcrzen wir unsere S\u00e4ule ein St\u00fcck, wobei wir darauf achten, unbedingt einen geraden Schnitt zu erhalten und dann installieren wir die S\u00e4ule am Einlass unseres Gaschromatografen. Dann sp\u00fclen wir die S\u00e4ule mit sauberem, trockenem Tr\u00e4gergas. Wir tun das, um vorhandene Luft komplett aus der S\u00e4ule zu entfernen. W\u00e4hrend wir die S\u00e4ule etwa 10 Minuten lang durchsp\u00fclen, m\u00fcssen wir darauf achten, dass wir die Temperatur nicht erh\u00f6hen. Das Sp\u00fclen sollte bei Raumtemperatur durchgef\u00fchrt werden. Wenn es dann an der Zeit ist, die S\u00e4ule zu konditionieren, m\u00fcssen wir zun\u00e4chst unsere Konditionierungstemperatur w\u00e4hlen. Dazu w\u00e4hlen wir entweder die maximal m\u00f6gliche Betriebstemperatur der S\u00e4ule (Maximaltemperatur) oder eine Temperatur, die um 20 Grad h\u00f6her liegt als die h\u00f6chste Temperatur, bei der wir die S\u00e4ule aktuell betreiben wollen. Von diesen beiden Temperaturen w\u00e4hlen wir dann die niedrigere. Wir heizen die S\u00e4ule dann auf diese Temperatur auf und konditionieren sie ungef\u00e4hr eine Stunde lang oder so lange bis die Basislinie sich stabilisiert hat. Sobald das eintritt, haben wir eine ordnungsgem\u00e4\u00df konditionierte GC-S\u00e4ule.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ich danke Ihnen vielmals, dass Sie sich diesen Tipp von Restek angesehen haben.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die Konditionierung einer neuen GC-Kapillars\u00e4ule minimiert das S\u00e4ulenbluten und hilft bei der Erstellung einer stabilen Basislinie.<\/p>\n","protected":false},"author":11,"featured_media":41031,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-42437","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3589-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42437","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42437"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42437\/revisions"}],"predecessor-version":[{"id":85794,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42437\/revisions\/85794"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41031"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42437"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42437"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42437"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42437"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42437"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42437"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42437"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42437"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42437"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}