{"id":42442,"date":"2018-10-23T04:00:00","date_gmt":"2018-10-23T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-saulen-installation\/"},"modified":"2026-01-28T22:24:34","modified_gmt":"2026-01-28T22:24:34","slug":"gc-saulen-installation","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3590-de\/gc-saulen-installation","title":{"rendered":"GC-S\u00e4ulen-Installation"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Column Installation\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/GGLDnWd4U40?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die ordnungsgem\u00e4\u00dfe Installation Ihrer Gaschromatografies\u00e4ule ist einer der vielen Teilschritte, die zu hervorragenden Ergebnissen f\u00fchren. Wir gehen die Schritte durch, die f\u00fcr eine gute Installation erforderlich sind, und geben Ihnen einige Tipps, wie Sie diese \u00fcberpr\u00fcfen k\u00f6nnen. Schauen Sie unbedingt in Ihrem Handbuch nach, um den f\u00fcr Ihr Ger\u00e4t spezifischen Installationsabstand zu ermitteln.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Restek Capillary Column Installation Guide:&nbsp;<\/li>\n\n\n\n<li>Check your column installation distance!<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/p\/20116\" target=\"_blank\" rel=\"noopener\">Ceramic Scoring Wafer<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/28500\" target=\"_blank\" rel=\"noopener\">Electronic Leak Detector<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu einem weiteren Restek-Tipp. Heute wollen wir uns mit der Installation von GC-S\u00e4ulen befassen. Dazu m\u00fcssen wir zun\u00e4chst unseren GC-Ofen abk\u00fchlen lassen und den Gasfluss durch das Ger\u00e4t abschalten. Anschlie\u00dfend entnehmen wir die S\u00e4ule aus dem Karton und befestigen Sie an der Aufh\u00e4ngung innen im Ofen. Nehmen Sie das Einlassende und schieben sie die S\u00e4ulenmutter und das passende Ferrule \u00fcber das S\u00e4ulenende. Als n\u00e4chstes wollen wir das S\u00e4ulenende abschneiden, um sicherzustellen, dass ein sauberer S\u00e4ulenabschnitt im Injektor installiert wird.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mithilfe einer Installationsf\u00fchrung wird die S\u00e4ulenl\u00e4nge auf die f\u00fcr den Injektor geeignete Tiefe eingestellt. Diese Tiefe finden Sie in Ihrem Ger\u00e4tehandbuch. Nachdem die korrekte Tiefe eingestellt wurde, ziehen Sie die S\u00e4ulenmutter gegen die Reduziermutter des Injektors fest, so dass die S\u00e4ule fest im Injektor sitzt. Nach der Installation unserer S\u00e4ule am Einlassende, f\u00fchren wir dieselben Schritte zur Installation am Detektorende durch. Und wie vorhin k\u00f6nnen Sie auch hier Ihr Ger\u00e4tehandbuch konsultieren, um die korrekte Einstellung der Installationstiefe f\u00fcr den jeweiligen Detektor zu gew\u00e4hrleisten. Achten Sie darauf, dass die S\u00e4ule keine starken Biegungen aufweist und dass sie die Ofenw\u00e4nde nicht ber\u00fchrt.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ein Trick, den ich gerne benutze, um sicherzustellen, dass ich die S\u00e4ulenmutter fest genug angezogen habe, besteht darin, an den Enden der S\u00e4ule leicht zu ziehen. Wenn das S\u00e4ulenende dabei herausrutscht, muss die S\u00e4ule neu installiert und die S\u00e4ulenmutter ein wenig fester angezogen werden. Andererseits darf die S\u00e4ulenmutter jedoch nicht zu fest angezogen werden, weil dies zu anderen Problemen f\u00fchren k\u00f6nnte. Nach der Installation sollten Sie mithilfe eines elektronischen Lecksuchers auf Undichtigkeiten pr\u00fcfen. Eine weitere Methode zur Pr\u00fcfung der Installation beruht auf der Injektion einer kleinen L\u00f6semittelmenge in das Ger\u00e4t. Wenn der L\u00f6semittelpeak zu viel Tailing aufweist, sollten Sie Ihre Installation noch einmal \u00fcberpr\u00fcfen. Ist der L\u00f6semittelpeak jedoch scharf, ist alles in Ordnung.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie mit Ihrer Installation zufrieden sind, k\u00f6nnen Sie Ihre S\u00e4ule konditionieren und mit der Probenanalyse beginnen. Vielen Dank f\u00fcr Ihr Interesse an diesem Tipp von Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Installieren Sie Ihre Gaschromatografies\u00e4ule richtig! In diesem Restek-Tipp zeigen wir Ihnen, was Sie daf\u00fcr brauchen!<\/p>\n","protected":false},"author":11,"featured_media":41037,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-42442","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3590-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42442","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42442"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42442\/revisions"}],"predecessor-version":[{"id":85790,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42442\/revisions\/85790"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41037"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42442"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42442"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42442"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42442"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42442"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42442"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42442"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42442"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42442"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}