{"id":42453,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-fehlersuche-starkes-saulenbluten\/"},"modified":"2026-01-28T22:24:15","modified_gmt":"2026-01-28T22:24:15","slug":"gc-fehlersuche-starkes-saulenbluten","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3597-de\/gc-fehlersuche-starkes-saulenbluten","title":{"rendered":"GC Fehlersuche\u2014Starkes S\u00e4ulenbluten"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Troubleshooting\u2014High GC Column Bleed\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/767MCWu86pQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Starkes S\u00e4ulenbluten ist eines der am h\u00e4ufigsten auftretenden Probleme in der Gaschromatografie. Es tritt oft in Verbindung mit der Zersetzung der station\u00e4ren Phase auf, z. B. wenn Sauerstoff durch eine undichte Stelle in das System gelangt oder durch einen aggressiven Probenbestandteil. Wichtige Schritte zur Vermeidung von \u00fcberm\u00e4\u00dfig starkem S\u00e4ulenbluten sind die Pr\u00fcfung auf Leckagen, die Installation eines Sauerstoff-Filters in der Tr\u00e4gergasleitung und Proben, die keine Bestandteile enthalten, die die S\u00e4ule sch\u00e4digen k\u00f6nnten.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar3294\/ultra-low-bleed-columns-improve-trace-level-analysis\" data-type=\"post\" data-id=\"43685\">Ultra\u2013Low Bleed Columns Improve Trace\u2013Level Analysis<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/articles\/rxi-gc-columns\" target=\"_blank\" rel=\"noopener\">Restek&#8217;s Inert and Low\u2013Bleed Rxi GC Column<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu einem weiteren Restek Tipp. Heute wollen wir \u00fcber starkes S\u00e4ulenbluten sprechen. Was verstehen wir \u00fcberhaupt unter S\u00e4ulenbluten im Zusammenhang mit der Gaschromatografie?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00e4ulenbluten ist der nat\u00fcrliche Zersetzungsprozess unserer station\u00e4ren Phase. Im Laufe der Zeit zersetzt sie sich ein wenig, und die Abbauprodukte der station\u00e4ren Phase durchlaufen dann die S\u00e4ule und erzeugen ein gewisses Signal. Von starkem S\u00e4ulenbluten spricht man, wenn dieser normale Vorgang sich zu einem Problem entwickelt. Das Signal wird sehr hoch, das S\u00e4ulenbluten tritt schon bei niedrigen Temperaturen oder unter au\u00dfergew\u00f6hnlichen Umst\u00e4nden auf. Was k\u00f6nnte die Ursache daf\u00fcr sein? Irgendetwas scheint ihre station\u00e4re Phase zu zersetzen. H\u00f6chstwahrscheinlich handelt es sich dabei um Sauerstoff. Sauerstoff ist ein echter S\u00e4ulenkiller. Er gelangt entweder \u00fcber undichte Stellen oder \u00fcber kontaminiertes Tr\u00e4gergas in das System. Eine andere M\u00f6glichkeit w\u00e4re, dass unsere station\u00e4re Phase durch aggressive Chemikalien besch\u00e4digt wird. Vielleicht haben wir ja irgendwelche Derivatisierungsreagenzien oder starke S\u00e4uren oder Basen injiziert. Diese k\u00f6nnen ebenfalls eine S\u00e4ule zerst\u00f6ren. In diesem Fall sollten wir vielleicht versuchen, unsere Injektion ein bisschen sanfter zu gestalten, indem wir weniger aggressive Chemikalien auf die S\u00e4ule aufgeben. Um noch einmal zum Sauerstoffproblem zur\u00fcckzukehren &#8230; das sollten wir auf jeden Fall immer im Auge behalten. Wir sollten unsere GC-Systeme st\u00e4ndig auf Leckagefreiheit \u00fcberpr\u00fcfen. Und wir m\u00fcssen immer sicherstellen, dass der Sauerstoff aus unserem Tr\u00e4gergas entfernt wird. Die Verwendung eines entsprechenden Inline-Filters kann dazu \u00e4u\u00dferst n\u00fctzlich sein.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mithilfe dieser Tools und Methoden sollten Sie in der Lage sein, das S\u00e4ulenbluten bei Ihrer Arbeit am GC zu kontrollieren. Vielen Dank f\u00fcr Ihr Interesse an diesem Restek Tipp.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Wie kann man starkes S\u00e4ulenbluten in der Gaschromatografie behandeln? In diesem Restek-Tipp erfahren Sie, wie Sie S\u00e4ulenbluten beheben und Ihre GC-S\u00e4ulen pflegen k\u00f6nnen.<\/p>\n","protected":false},"author":11,"featured_media":41073,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42453","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3597-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42453"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42453\/revisions"}],"predecessor-version":[{"id":85789,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42453\/revisions\/85789"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41073"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42453"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42453"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42453"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42453"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42453"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42453"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42453"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42453"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}