{"id":42458,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-fehlerbehebung-geteilte-peaks\/"},"modified":"2025-12-17T15:08:29","modified_gmt":"2025-12-17T15:08:29","slug":"gc-fehlerbehebung-geteilte-peaks","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3601-de\/gc-fehlerbehebung-geteilte-peaks","title":{"rendered":"GC-Fehlerbehebung &#8211; geteilte Peaks"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Troubleshooting\u2014Split Peaks\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/fPbvbmCBhek?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p>Gesplittete Peaks k\u00f6nnen in der Gaschromatografie auftreten, wenn die Injektion nicht richtig funktioniert oder wenn es Probleme beim \u00dcbergang vom Inlet auf die S\u00e4ule gibt. Bei der Fehlersuche in Bezug auf gesplittete Peaks sollten wir auf die Konfiguration und Einrichtung des Einlasses achten und sicherstellen, dass alles mit der Injektion richtig funktioniert. Au\u00dferdem sollten wir sicherstellen, dass die station\u00e4re Phase der S\u00e4ule und das L\u00f6sungsmittel miteinander kompatibel sind.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/chromablography\/avoiding-split-peaks-in-gas-chromatography-for-quechers-extracts-in-acetonitrile\" target=\"_blank\" rel=\"noreferrer noopener\">Avoiding Split Peaks in Gas Chromatography for QuEChERS Extracts in Acetonitrile<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1210?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">GC Inlet Liners and Liner Supplies<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p>Hallo allerseits und herzlich willkommen zu einem weiteren Restek-Tipp. Heute wollen wir uns mit gesplitteten Peaks befassen.<\/p>\n\n\n\n<p>Angenommen wir f\u00fchren eine GC-Analyse durch und finden einige gesplittete Peaks. Was k\u00f6nnte der Grund daf\u00fcr sein? Wenn wir \u00fcber gesplittete Peaks nachdenken, k\u00f6nnen wir generell davon ausgehen, dass irgendetwas den Probentransfer vom Injektionsport auf die S\u00e4ule st\u00f6rt, jedenfalls in den meisten F\u00e4llen. Das hei\u00dft, die Probe wird nicht in einer sch\u00f6nen engen Bande \u00fcbertragen. Stattdessen verteilen sich die Probenbestandteile im Laufe der Zeit oder werden voneinander getrennt.<\/p>\n\n\n\n<p>Was k\u00f6nnte der Grund daf\u00fcr sein? Es k\u00f6nnte sich um ein Injektionsproblem handeln. Selbst etwas ganz einfaches, wenn zum Beispiel unsere Spritze die Probe nicht gleichm\u00e4\u00dfig in den Injektionsport injiziert oder wenn unsere Probe im Injektor keine homogene Dampfwolke bildet, bevor sie auf die S\u00e4ule aufgetragen wird.<\/p>\n\n\n\n<p>Oder Aerosoltr\u00f6pfchen k\u00f6nnten auf die S\u00e4ule gelangen, und das k\u00f6nnte zur Bildung von gesplitteten Peaks beitragen. Wenn wir das ein wenig verbessern wollen, sollten wir irgendeine Art von F\u00fcller in unserem Liner haben oder einen Liner mit einer speziellen Geometrie verwenden, um sicherzustellen, dass die gesamte Probe in die Dampfphase \u00fcberf\u00fchrt wird und keine Aerosoltr\u00f6pfchen die S\u00e4ule erreichen k\u00f6nnen.<\/p>\n\n\n\n<p>In Bezug auf die S\u00e4ule selbst, k\u00f6nnten wir auch hier einige Probleme haben, besonders eine Diskrepanz der Polarit\u00e4ten von L\u00f6semittel und station\u00e4rer Phase, so dass das L\u00f6semittel die station\u00e4re Phase nicht gleichm\u00e4\u00dfig benetzen kann. Um dieses Problem zu beseitigen, sollten wir ein L\u00f6semittel und eine station\u00e4re Phase ausw\u00e4hlen, die \u00e4hnlichere Polarit\u00e4ten aufweisen, so dass sie miteinander mischbar sind.&nbsp;<\/p>\n\n\n\n<p>Dies sind einige der h\u00e4ufig vorkommenden Ursachen und L\u00f6sungsans\u00e4tze, um gesplittete Peaks zu vermeiden. Vielen Dank f\u00fcr Ihr Interesse an diesem Tipp von Restek!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Haben Sie genug von geteilten Peaks? Probieren Sie diese Fehlerbehebungstechniken von Restek Tip aus, um Ihre Chromatografie zu verbessern.<\/p>\n","protected":false},"author":11,"featured_media":41091,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480,2492,2494],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-42458","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-gaschromatographie-produkte","product-library-gc-saulen","product-library-inlet-zubehor","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"},{"value":2494,"label":"Inlet Zubeh\u00f6r"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3601-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":136,"filter":"raw","cat_ID":772,"category_count":136,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42458","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42458"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42458\/revisions"}],"predecessor-version":[{"id":75031,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42458\/revisions\/75031"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41091"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42458"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42458"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42458"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42458"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42458"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42458"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42458"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42458"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42458"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}