{"id":42460,"date":"2018-01-14T05:00:00","date_gmt":"2018-01-14T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-fehlersuche-nachlaufende-peaks\/"},"modified":"2025-12-17T14:39:41","modified_gmt":"2025-12-17T14:39:41","slug":"gc-fehlersuche-nachlaufende-peaks","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3602-de\/gc-fehlersuche-nachlaufende-peaks","title":{"rendered":"GC-Fehlersuche &#8211; Nachlaufende Peaks"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Troubleshooting\u2014Tailing Peaks\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/YQ7CoDr1WBs?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Unsere Chromatogramme k\u00f6nnen uns viel sagen, vor allem, wenn wir uns auf die Details konzentrieren. Die Diagnose und Korrektur von tailenden Peaks ist ein Bereich, in dem eine besondere Aufmerksamkeit f\u00fcr das Chromatogramm besonders hilfreich sein kann. Wir werfen einen Blick auf einige der Ursachen von tailenden Peaks, die ein sehr h\u00e4ufiges Problem darstellen, und darauf, wie unser Chromatogramm uns Hinweise auf ihre Ursache geben kann.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Why do only some of my peaks tail?<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/articles\/topaz-gc-inlet-liners\" target=\"_blank\" rel=\"noopener\">Topaz Inlet Liner<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu einem weiteren Restek-Tipp.&nbsp;In diesem Video befassen wir uns mit dem Tailing von Peaks, was h\u00e4ufig vorkommt, wenn wir gaschromatografische Analysen durchf\u00fchren.<br>Normalerweise l\u00e4sst sich das Peak-Tailing auf eine von zwei Ursachen zur\u00fcckf\u00fchren. Entweder liegt eine St\u00f6rung unseres Flusswegs vor oder es findet irgendeine Art von reversibler chemischer Adsorption statt. Aber wie k\u00f6nnen wir zwischen diesen beiden Ursachen unterscheiden?<br>Als erstes sollten wir uns unser Chromatogramm anschauen. Wenn die meisten oder alle unserer Peaks Tailing zeigen, wird diese Art des Tailings oft durch eine St\u00f6rung des Flusswegs verursacht, durch etwas, was alle vorliegenden Verbindungen beeinflusst.<br>Sind im Gegensatz dazu nur einige unserer Peaks betroffen, k\u00f6nnte es sich um irgendeine Art von chemischem Verhalten handeln, irgendeine Art von Adsorption oder Wechselwirkung aufgrund einer bestimmten Verbindung oder Verbindungsklasse.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br>Nachdem wir dies also gekl\u00e4rt haben, was k\u00f6nnen wir tun, um diese Probleme zu beseitigen?&nbsp;Also, wenn eine St\u00f6rung des Flusswegs vorliegt, sollten wir daf\u00fcr sorgen, dass alle Abst\u00e4nde in unserer Installation korrekt sind, dass unsere S\u00e4ulen rechtwinklig geschnitten sind, dass alle unsere Verbindungen leckagefrei sind und dass das Totvolumen m\u00f6glichst klein ist.&nbsp;Bez\u00fcglich der Sauberkeit des Systems und der chemischen Adsorption m\u00fcssen wir sicherstellen, dass alles sauber und inert ist.<br>Das hei\u00dft, es k\u00f6nnte an der Zeit sein, einige Wartungsarbeiten durchzuf\u00fchren \u2013 den Liner oder die Injektordichtung zu erneuern oder die Vors\u00e4ule vielleicht ein wenig zu verk\u00fcrzen, kurz gesagt, alles was wir tun k\u00f6nnen, um sicherzustellen, dass der gesamte Flussweg sauber und deaktiviert ist, damit jegliche Wechselwirkungen m\u00f6glichst vermieden werden.&nbsp;Das sind also prinzipiell die beiden Ans\u00e4tze, die wir verfolgen k\u00f6nnen, um die Grundursachen f\u00fcr die meisten unserer Probleme mit dem Peak-Tailing anzugehen. Vielen Dank f\u00fcr Ihr Interesse an diesem Tipp von Restek!<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Es ist Zeit f\u00fcr eine kurze Geschichte \u00fcber Tailing. In diesem Restek-Tipp sprechen wir \u00fcber einige Tipps und Tricks zur Behebung von nachlaufenden Peaks.<\/p>\n","protected":false},"author":11,"featured_media":41097,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2385,2480,2493,2494],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-42460","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-ferrules-fittings-connectors","product-library-gaschromatographie-produkte","product-library-gc-ferrules-fittings-verbinder","product-library-inlet-zubehor","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2385,"label":"Ferrules, Fittings, Connectors"},{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2493,"label":"GC Ferrules, Fittings &amp; Verbinder"},{"value":2494,"label":"Inlet Zubeh\u00f6r"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3602-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":772,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/live-discover-restek.pantheonsite.io\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/live-discover-restek.pantheonsite.io\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42460","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42460"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42460\/revisions"}],"predecessor-version":[{"id":74957,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42460\/revisions\/74957"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41097"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42460"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42460"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42460"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42460"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42460"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42460"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42460"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42460"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42460"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}