{"id":42480,"date":"2019-05-21T04:00:00","date_gmt":"2019-05-21T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/reinigung-und-regeneration-von-lc-saulen\/"},"modified":"2026-01-28T22:30:54","modified_gmt":"2026-01-28T22:30:54","slug":"reinigung-und-regeneration-von-lc-saulen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3616-de\/reinigung-und-regeneration-von-lc-saulen","title":{"rendered":"Reinigung und Regeneration von LC-S\u00e4ulen"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"LC Column Cleaning and Regeneration\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/F4cdVXmjRw8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Im Laufe der Zeit sammeln sich in unseren Fl\u00fcssigchromatografies\u00e4ulen Verunreinigungen an, insbesondere wenn wir regelm\u00e4\u00dfig verschmutzte Proben analysieren. Es gibt einige Ma\u00dfnahmen, die wir ergreifen k\u00f6nnen, um unsere S\u00e4ulen sauber zu halten. Dar\u00fcber hinaus k\u00f6nnen wir auch eine begrenzte S\u00e4ulenregeneration durchf\u00fchren, die oft dazu beitragen kann, die Leistung unserer S\u00e4ulen wiederherzustellen und ihre Lebensdauer zu verl\u00e4ngern.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar3266\/restek-liquid-chromatography-lc-columns-cleaning-recommendations\" data-type=\"post\" data-id=\"43670\">LC Column Cleaning Recommendations<\/a><\/li>\n\n\n\n<li>LC Guard Column Selector<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1119\" target=\"_blank\" rel=\"noopener\">LC S\u00e4ulen<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1277\" target=\"_blank\" rel=\"noopener\">Guard Cartridges and Hardware<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1123\" target=\"_blank\" rel=\"noopener\">Mobile Phase Accessories<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vielen Dank f\u00fcr Ihr Interesse an unserem neuesten Restek-Tipp, in dem wir uns mit der Reinigung und Regenerierung von LC-S\u00e4ulen befassen. S\u00e4ulenkontamination aufgrund der Adsorption von Analyten oder Matrixverunreinigungen kann sich nachteilig auf die Chromatografie auswirken und zu Problemen wie gesplitteten Peaks, \u00c4nderungen der Selektivit\u00e4t oder verringerter Empfindlichkeit f\u00fchren, die letztlich alle die quantitative Analyse beeintr\u00e4chtigen k\u00f6nnen. Es wird unbedingt empfohlen, Vors\u00e4ulen oder einen UltraShield-Vors\u00e4ulenfilter zum Schutz Ihrer analytischen S\u00e4ulen zu verwenden. Mit der Zeit k\u00f6nnen Sie jedoch selbst mit diesen Vorsichtsma\u00dfnahmen m\u00f6glicherweise eine reduzierte S\u00e4ulenperformance, einen h\u00f6heren Gegendruck oder andere Anzeichen von S\u00e4ulenkontamination feststellen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Reinigung und Regenerierung von HPLC oder UHPLC-S\u00e4ulen wird das Sp\u00fclen unter Verwendung einer Reihe von st\u00e4rkeren L\u00f6semittelkombinationen in der auf der S\u00e4ule angezeigten Flussrichtung empfohlen. F\u00fcr Reversed-Phase-S\u00e4ulen die S\u00e4ule mit wenigstens 20 S\u00e4ulenvolumina jedes L\u00f6semittels sp\u00fclen, und zwar in der in der Tabelle angegebenen Reihenfolge, von 5 % Methanol in Wasser bis zu L\u00f6semitteln mit hohem organischen Anteil und wieder zur\u00fcck zu den Anfangsbedingungen Ihrer mobilen Phase. F\u00fcr Normalphasens\u00e4ulen die S\u00e4ule mit wenigstens 20 S\u00e4ulenvolumina jedes L\u00f6semittels sp\u00fclen, und zwar in der in der Tabelle angegebenen Reihenfolge, von Isopropylalkohol bis zu Ethanol und wieder zur\u00fcck zu den Anfangsbedingungen Ihrer mobilen Phase. Das S\u00e4ulenvolumen l\u00e4sst sich anhand der hier gezeigten Formel absch\u00e4tzen. Es wird unbedingt empfohlen, Ihre S\u00e4ule wieder auf die Anfangsbedingungen Ihrer Methode zu \u00e4quilibrieren, indem eine Reihe von Injektionen vor Beginn Ihrer Probencharge durchgef\u00fchrt wird. Nach der S\u00e4ulenregenerierung ist es wichtig, dass Sie Ihre LC-S\u00e4ulen mit fest verschlossenen Endkappen und dem von Ihrem S\u00e4ulenhersteller empfohlenen L\u00f6semittel f\u00fcr kurz- oder langfristige Lagerung aufbewahren.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Ihnen diese Videos gefallen, geben Sie uns ein Like, teilen Sie sie mit anderen und abonnieren Sie sie. Sie k\u00f6nnen uns Ihre Vorschl\u00e4ge f\u00fcr zuk\u00fcnftige Tech-Tipps in den Kommentaren unten mitteilen. Vielen Dank f\u00fcr Ihr Interesse an diesem neuesten Restek-Tipp.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In diesem Restek-Tipp geht es um Fl\u00fcssigchromatografie und speziell um die Lebensdauer von S\u00e4ulen. Wir haben einige Informationen zur Reinigung und Regeneration von LC-S\u00e4ulen.<\/p>\n","protected":false},"author":11,"featured_media":41145,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2499],"resource-technique":[2326],"ppma_author":[414],"class_list":["post-42480","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-lc-saulen","resource-technique-flussigchromatografie"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3616-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42480","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42480"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42480\/revisions"}],"predecessor-version":[{"id":85799,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42480\/revisions\/85799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41145"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42480"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42480"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42480"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42480"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42480"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42480"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42480"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42480"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42480"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}