{"id":42483,"date":"2018-04-24T04:00:00","date_gmt":"2018-04-24T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/konditionierung-von-lc-saulen\/"},"modified":"2026-01-28T22:26:29","modified_gmt":"2026-01-28T22:26:29","slug":"konditionierung-von-lc-saulen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3617-de\/konditionierung-von-lc-saulen","title":{"rendered":"Konditionierung von LC-S\u00e4ulen"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"LC Column Conditioning\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/JYaLzRUxI7s?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Saubere, stabile Basislinien sind f\u00fcr eine gute Fl\u00fcssigchromatografie von entscheidender Bedeutung, und die ordnungsgem\u00e4\u00dfe Konditionierung Ihrer LC-S\u00e4ule ist eine hilfreiche Methode, um eine gute Basislinie zu gew\u00e4hrleisten. Sie m\u00fcssen das Lagerl\u00f6sungsmittel aussp\u00fclen und die S\u00e4ule mit Ihrem L\u00f6sungsmittelgemisch \u00e4quilibrieren. M\u00f6glicherweise m\u00fcssen Sie ein Zwischenl\u00f6sungsmittel verwenden, um eine vollst\u00e4ndige Durchmischung und Sp\u00fclung zu gew\u00e4hrleisten.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Do reverse phase HPLC columns really need conditioning?<\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/instruction-sheet\/700-02-002\/restek-liquid-chromatography-lc-columns-usage-care\" data-type=\"post\" data-id=\"5656\">Restek LC Columns Usage &amp; Care<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1275\" target=\"_blank\" rel=\"noopener\">HPLC &amp; UHPLC Analytical Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo allerseits! Vielen Dank f\u00fcr Ihr Interesse an diesem Restek-Tipp! Unser heutiges Thema ist die S\u00e4ulenkonditionierung. In den meisten F\u00e4llen ist die S\u00e4ule nicht sofort nach dem Auspacken einsatzbereit, es sei denn, die mobile Phase, die Sie verwenden, ist identisch mit unserem zur Lagerung verwendeten L\u00f6semittel. Das Analysenzertifikat gibt das zur Lagerung verwendete L\u00f6semittel an, und Sie k\u00f6nnen das Zertifikat mithilfe des innen im S\u00e4ulenkarton angegeben Links einsehen oder herunterladen. Die meisten unserer S\u00e4ulen werden in L\u00f6semitteln gelagert, die einen organischen Anteil von mehr als 50 % aufweisen. Wenn Sie eine organische mobile Phase verwenden, die mit dem zur Lagerung verwendeten L\u00f6semittel nicht \u00fcbereinstimmt, sollten Sie die S\u00e4ule zun\u00e4chst mit einem L\u00f6semittel mit 10 oder 20 % kleinerem organischem Anteil sp\u00fclen. Tun Sie dies f\u00fcr circa 10 S\u00e4ulenvolumina und wechseln Sie dann auf das L\u00f6semittel \u00fcber, das Sie f\u00fcr Ihre Methode verwenden wollen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;Falls Sie vergessen haben, wie man das S\u00e4ulenvolumen berechnet, k\u00f6nnen Sie eine dieser beiden Formeln verwenden. Und beachten Sie dabei, dass der Wert f\u00fcr die Konstante unterschiedlich ist, je nachdem, ob Sie vollpor\u00f6se oder oberfl\u00e4chlich por\u00f6se Partikel verwenden. Wenn Sie in Ihrer Methode Puffer verwenden, sollten Sie zun\u00e4chst mit einem 10 bis 20 % kleineren organischen Anteil als im zur Lagerung verwendeten L\u00f6semittel sp\u00fclen. Dadurch wird sichergestellt, dass es bei der Einf\u00fchrung des Puffers nicht zur Ausf\u00e4llung von Salzen kommt, die den Gegendruck erh\u00f6hen und letztlich die S\u00e4ule verstopfen w\u00fcrden. Nach etwa 10 S\u00e4ulenvolumina k\u00f6nnen Sie zur mobilen Phase, die Sie verwenden wollen, mit eingeschlossenem Puffer \u00fcbergehen, und dann noch einmal mit etwa 10 S\u00e4ulenvolumina sp\u00fclen. Warten Sie ab, bis sich die Baseline f\u00fcr Druck stabilisiert, weil dies anzeigt, dass die S\u00e4ule sich \u00e4quilibriert. Viele Analytiker f\u00fchren gerne ein oder zwei Injektionen zur Konditionierung durch, bevor sie ihren Probenlauf starten. Das ist eine gute M\u00f6glichkeit, die S\u00e4ule sozusagen betriebsbereit zu machen und sie auf die Bedingungen vorzubereiten, die Sie f\u00fcr Ihre Methode verwenden werden. Nachdem Sie ein paar dieser Injektionen durchgef\u00fchrt haben, k\u00f6nnen Sie dann den Rest Ihrer Probenanalyse abarbeiten. Ich hoffe, das hat Ihnen die S\u00e4ulen\u00e4quilibrierung ein wenig verst\u00e4ndlicher gemacht. Freuen Sie sich auf weitere Tipps von Ihren Freunden bei Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die Konditionierung Ihrer LC-S\u00e4ule ist entscheidend. Dieser Restek-Tipp beantwortet Ihre Fragen zur Konditionierung!<\/p>\n","protected":false},"author":11,"featured_media":41151,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2499],"resource-technique":[2326],"ppma_author":[414],"class_list":["post-42483","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-lc-saulen","resource-technique-flussigchromatografie"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3617-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42483"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42483\/revisions"}],"predecessor-version":[{"id":85795,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42483\/revisions\/85795"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41151"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42483"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42483"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42483"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42483"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42483"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42483"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42483"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42483"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}