{"id":42496,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/restek-tipp-lc-systemvolumen-minimieren\/"},"modified":"2025-12-17T16:20:45","modified_gmt":"2025-12-17T16:20:45","slug":"restek-tipp-lc-systemvolumen-minimieren","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3626-de\/restek-tipp-lc-systemvolumen-minimieren","title":{"rendered":"Restek Tipp: LC-Systemvolumen minimieren"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Minimizing LC System Volume\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/rf5GMxIKlts?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ein zu gro\u00dfes Systemvolumen kann eine Reihe von Problemen bei der Fl\u00fcssigchromatografie (LC) verursachen. Au\u00dferdem k\u00f6nnen Unterschiede im Systemvolumen zwischen unterschiedlichen Ger\u00e4ten zu erheblichen Diskrepanzen f\u00fchren. Dichte Anschl\u00fcsse, die Verwendung kurzer Zuleitungen und Zuleitungen mit entsprechendem Innendurchmesser helfen Ihnen, die Performance Ihrer Fl\u00fcssigchromatografie zu optimieren.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Troubleshooting HPLC \u2013 Tailing Peaks<\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/gnot5082\/how-do-i-know-what-the-internal-diameter-of-my-lc-tubing-is\/\" data-type=\"post\" data-id=\"3334\">How do I know what the internal diameter of my LC tubing is?<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1121\" target=\"_blank\" rel=\"noopener\">LC Tubing and Connectors<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/p\/25069\" target=\"_blank\" rel=\"noopener\">Clean-Cut Tubing Cutter<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vielen Dank f\u00fcr Ihr Interesse an unserem aktuellen Restek Tipp. Heute m\u00f6chte ich mit Ihnen \u00fcber den Einfluss des Systemvolumens auf die Chromatografie-Performance sprechen. Viele von uns \u00fcbertragen innerhalb unseres Labors Methoden von einem Ger\u00e4t auf ein anderes Ger\u00e4t. Und dabei stellen wir manchmal ziemlich gro\u00dfe Unterschiede im chromatografischen Verhalten fest, z. B. \u00c4nderungen bei der Retentionszeit, Verlust an Aufl\u00f6sung und manchmal sogar Peakverbreiterung. Was wir oft vergessen ist, wie sich das Systemvolumen \u00e4ndert, wenn wir unsere Methoden von einem Ger\u00e4t auf ein anderes Ger\u00e4t \u00fcbertragen. Selbst ein Unterschied von nur 20 Mikrolitern kann das chromatografische Verhalten von einem Ger\u00e4t zum anderen wesentlich beeinflussen. Aufl\u00f6sungsverlust und \u00c4nderungen der Retentionszeit sind alles Dinge, auf die wir bei der Methoden\u00fcbertragung gut verzichten k\u00f6nnen. Es gibt allerdings einige Dinge, die wir versuchen k\u00f6nnen, um diese Auswirkungen zu minimieren, wenn wir Methoden innerhalb unseres Labors von einem Ger\u00e4t auf ein anderes Ger\u00e4t \u00fcbertragen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ein guter Anfang ist die \u00dcberpr\u00fcfung unserer Anschl\u00fcsse. Wenn wir auf dichte Verbindungen in unserem gesamten System achten, auch am Einlass in die S\u00e4ule, k\u00f6nnen wir eine Zunahme des Systemvolumens vermeiden. Zweitens w\u00fcrde ich mir den Innendurchmesser der verwendeten Zuleitungen ansehen, um sicherzugehen, dass er mit fr\u00fcheren Systemen vergleichbar ist und dass das Totvolumen des Systems m\u00f6glichst \u00e4hnlich ist wie bei den vorherigen Ger\u00e4ten. Letztlich sollte man \u00fcber eine Reduzierung der L\u00e4nge der Zuleitungen nachdenken. Die Verk\u00fcrzung dieser Verbindungen kann helfen, die Peakdispersion insgesamt zu reduzieren und auch das Gesamtvolumen unseres Systems.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das sind einige der Dinge, die ich normalerweise versuche, wenn ich in meinem Labor Methoden von einem Ger\u00e4t auf ein anderes Ger\u00e4t \u00fcbertragen m\u00f6chte, um die Auswirkungen des zus\u00e4tzlichen Systemvolumens zu reduzieren.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nochmals vielen Dank f\u00fcr Ihr Interesse an unserem aktuellen Restek Tipp.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In diesem Restek-Tipp geht es darum, das Volumen zu reduzieren! Ein niedriges Systemvolumen erm\u00f6glicht die beste Fl\u00fcssigchromatografie und sorgt f\u00fcr ein \u00e4hnliches Systemvolumen bei mehreren Ger\u00e4ten, um konsistente Daten zu gew\u00e4hrleisten.<\/p>\n","protected":false},"author":11,"featured_media":41199,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2504],"resource-technique":[2299],"ppma_author":[414],"class_list":["post-42496","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-lc-schlauche-fittings","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2504,"label":"LC Schl\u00e4uche &amp; Fittings"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3626-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42496"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42496\/revisions"}],"predecessor-version":[{"id":75090,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42496\/revisions\/75090"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41199"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42496"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42496"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42496"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42496"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42496"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42496"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}