{"id":42518,"date":"2018-01-03T05:00:00","date_gmt":"2018-01-03T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/restek-tipp-austausch-eines-gc-inlet-liners\/"},"modified":"2025-12-17T16:13:55","modified_gmt":"2025-12-17T16:13:55","slug":"restek-tipp-austausch-eines-gc-inlet-liners","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3644-de\/restek-tipp-austausch-eines-gc-inlet-liners","title":{"rendered":"Restek Tipp: Austausch eines GC Inlet Liners"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Replacing a GC Inlet Liner\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/e2sGYmg1B-o?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Routinem\u00e4\u00dfige Wartung ist bei der Gaschromatografie wichtig und der Austausch der GC Inlet Liner ist eine der am h\u00e4ufigsten anfallenden Arbeiten. In diesem Beispiel tauschen wir den Liner eines Agilent 7890 Gaschromatografen aus. Die Vorgehensweise kann je nach Ger\u00e4t oder Konfiguration unterschiedlich sein.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/gnss2704\/gc-inlet-maintenance-resteks-quick-reference-guide\/\" data-type=\"post\" data-id=\"43823\">GC Inlet Maintenance Quick Reference Guide<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/gnar1991\/how-to-choose-a-gc-inlet-liner\/\" data-type=\"post\" data-id=\"45274\">How to Choose a GC Inlet Liner<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1210\" target=\"_blank\" rel=\"noopener\">Topaz Inlet Liners<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/p\/26262\" target=\"_blank\" rel=\"noopener\">The Claw Inlet Liner Removal Tool<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu einem weiteren Restek Tipp. In diesem Video werden wir unseren GC Inlet Liner austauschen. Hierbei handelt es sich um einen allt\u00e4glichen Wartungsschritt f\u00fcr unser Ger\u00e4t, f\u00fcr den wir eigentlich nur ein Werkzeug ben\u00f6tigen. Was wir brauchen ist eine Vorrichtung zur Entfernung des alten Liners und zur Einf\u00fchrung des neuen Liners, ohne ihn zu kontaminieren. Dabei wollen wir sichergehen, dass der neue Liner sauber und unber\u00fchrt bleibt. Eine Pinzette oder das &#8216;Claw&#8217; Greifwerkzeug von Restek sind ideal f\u00fcr diesen Zweck. Au\u00dferdem sollten wir darauf achten, den Einlass abk\u00fchlen zu lassen, bis er nur noch handwarm ist. Schlie\u00dflich wollen wir uns nicht die Finger verbrennen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sobald der Einlass abgek\u00fchlt ist, k\u00f6nnen wir den Injektorkopf abnehmen, um Zugang zum Liner selbst zu erhalten.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mit unserem Greifwerkzeug nehmen wir den alten Liner heraus und entsorgen ihn ordnungsgem\u00e4\u00df. Beim Einsetzen des neuen Liners sollten wir alles tun, um sicherzugehen, dass er sauber bleibt. Kontakt mit den Fingern sollte m\u00f6glichst vermieden werden. Au\u00dferdem sollten wir nicht vergessen, einen sauberen, neuen O-Ring auf dem Liner anzubringen. Neuer Liner, neuer O-Ring! Setzen Sie den neuen Liner mit dem Greifwerkzeug in den Injektor ein, und verschlie\u00dfen Sie den Injektorkopf. Und das ist auch schon alles, was f\u00fcr diesen Wartungsschritt zum Austausch unseres GC-Inlet-Liners ben\u00f6tigt wird. Vielen Dank f\u00fcr Ihr Interesse an diesem Restek Tipp.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Tauschen Sie Ihre GC Inlet Liner regelm\u00e4\u00dfig aus! Sehen Sie sich dieses Restek-Tipp Video an, wie man es richtig macht.<\/p>\n","protected":false},"author":11,"featured_media":41223,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480,2494],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-42518","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-gaschromatographie-produkte","product-library-inlet-zubehor","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2494,"label":"Inlet Zubeh\u00f6r"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3644-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42518","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42518"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42518\/revisions"}],"predecessor-version":[{"id":75079,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42518\/revisions\/75079"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41223"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42518"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42518"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42518"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42518"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42518"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42518"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42518"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42518"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42518"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}