{"id":42535,"date":"2020-10-18T18:30:00","date_gmt":"2020-10-18T18:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/die-bedeutung-der-gc-fid-wartung\/"},"modified":"2025-12-17T14:04:00","modified_gmt":"2025-12-17T14:04:00","slug":"die-bedeutung-der-gc-fid-wartung","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav3660-de\/die-bedeutung-der-gc-fid-wartung","title":{"rendered":"Die Bedeutung der GC-FID-Wartung"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"The Importance of GC FID Maintenance\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/wc2HPTBzrzE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Flammenionisationsdetektoren (FIDs) geh\u00f6ren zu den am h\u00e4ufigsten verwendeten gaschromatografischen (GC) Detektoren. Um eine optimale Leistung zu erzielen, m\u00fcssen sie routinem\u00e4\u00dfig \u00fcberpr\u00fcft und gewartet werden. Wir besprechen einige h\u00e4ufige Symptome, die auf einen Wartungsbedarf hinweisen, und die wichtigsten Aufgaben, damit Ihr FID optimal funktioniert.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/gnbl4866\/when-your-data-goes-boing-an-electrifying-tale-of-fid-troubleshooting\/\" data-type=\"post\" data-id=\"51857\">A Tale of FID Troubleshooting<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/de\/c\/1420\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/de\/c\/1420\" target=\"_blank\" rel=\"noopener\">Detector Supplies<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu einem weiteren Restek-Tipp. In unserem heutigen Tipp geht es um die Wartung Ihres Flammenionisationsdetektors oder FID. Nehmen wir an, Sie arbeiten in einem Labor, in dem t\u00e4glich Hunderte von Probenanalysen durchgef\u00fchrt werden. Im Laufe der Zeit k\u00f6nnen diese Proben Ihr GC-System, einschlie\u00dflich des FID, ziemlich stark kontaminieren. Es kann zu Problemen wie einer hohen Basislinie, einem Verlust der Empfindlichkeit oder Rauschspitzen kommen, oder vielleicht z\u00fcndet die Flamme einfach nicht mehr. Manchmal kann das FID so stark verschmutzt sein, dass Sie Probenablagerungen im Inneren des Aufsatzes der Z\u00fcndvorrichtung erkennen k\u00f6nnen. Das ist ein gutes Anzeichen daf\u00fcr, dass es an der Zeit ist, einige Wartungsarbeiten an Ihrem FID durchzuf\u00fchren!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn Sie die D\u00fcse erneuert haben, die Probleme jedoch weiterhin bestehen, wird es vielleicht Zeit, einige FID-Teile auszutauschen. Dazu geh\u00f6ren der Aufsatz der Z\u00fcndvorrichtung, die oberen und unteren PTFE-Isolatoren, der Kollektor, die Gummidichtung f\u00fcr das Geh\u00e4use und die FID-D\u00fcse. Zum Austausch dieser Teile m\u00fcssen Sie das GC-Ger\u00e4t zun\u00e4chst abk\u00fchlen lassen, den Gasfluss durch das Ger\u00e4t abschalten, die S\u00e4ule vom Detektor trennen und den FID abk\u00fchlen lassen. Denken Sie auch daran, alle Gasfl\u00fcsse an den FID abzuschalten. Dann k\u00f6nnen wir anfangen, den FID auseinanderzubauen. Entfernen Sie den Z\u00fcnder und alle Torx-Schrauben aus dem FID-Geh\u00e4use. Entfernen Sie anschlie\u00dfend die R\u00e4ndelmutter aus Messing und die Federscheibe.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vor dem Wiedereinbau der neuen Teile reinige ich das FID-Geh\u00e4use meistens mit ein wenig Methanol. Danach k\u00f6nnen wir den Aufsatz der Z\u00fcndvorrichtung, die PTFE-Isolatoren, den Kollektor und die Gummidichtung f\u00fcr das Geh\u00e4use wieder einsetzen. Nach dem Austausch unserer Teile wird das FID-Geh\u00e4use wieder mit dem GC verbunden und der Z\u00fcnder wird wieder an den Aufsatz der Z\u00fcndvorrichtung angeschlossen. Schlie\u00dfen Sie die S\u00e4ule wieder an und bringen Sie den GC und den FID wieder in seinen normalen Betriebszustand zur\u00fcck. Lassen Sie den FID eine Zeit lang bei seiner Betriebstemperatur konditionieren, um fl\u00fcchtige Verunreinigungen zu entfernen. Danach sollte Ihr FID so gut wie neu sein!<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Danke, dass Sie sich die Zeit zum Anschauen dieses Videos genommen haben. Und wenn Sie irgendetwas Bestimmtes sehen wollen, schreiben Sie uns unten einfach einen Kommentar! Und vergessen Sie nicht, uns ein Like auf unseren Social Media-Seiten zu geben! Wir hoffen, dass Ihnen dieser Restek-Tipp gefallen hat.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Haben Sie Probleme mit Ihrem FID? Entfachen Sie die Flamme wieder mit diesen Tipps zur FID-Wartung in diesem Restek-Tipp!<\/p>\n","protected":false},"author":11,"featured_media":41295,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42535","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3660-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42535"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42535\/revisions"}],"predecessor-version":[{"id":74937,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42535\/revisions\/74937"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41295"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42535"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42535"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42535"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42535"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42535"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42535"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}