{"id":42580,"date":"2019-10-29T04:00:00","date_gmt":"2019-10-29T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/auswahl-des-puffers-fur-die-hilic-chromatografie\/"},"modified":"2026-01-28T22:21:07","modified_gmt":"2026-01-28T22:21:07","slug":"auswahl-des-puffers-fur-die-hilic-chromatografie","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav4887-de\/auswahl-des-puffers-fur-die-hilic-chromatografie","title":{"rendered":"Auswahl des Puffers f\u00fcr die HILIC-Chromatografie"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Buffer Choices for HILIC\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/O0WWmQmhzpk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p>HILIC steht f\u00fcr \u201eHydrophilic Interaction Liquid Chromatography\u201c und ist eine leistungsstarke spezielle Form der Fl\u00fcssigkeitschromatografie (LC), bei der polare station\u00e4re Phasen und eine anf\u00e4ngliche mobile Phase mit hohem organischen Anteil zur Trennung polarer Analyte verwendet werden. Puffer spielen bei der HILIC eine wichtige Rolle, da der Ionisationszustand der Analyte und der station\u00e4ren Phase die Trennung beeinflusst. Hier beschreiben wir ein Verfahren zur Optimierung der verwendeten Pufferkonzentrationen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnar2716\/how-to-avoid-common-problems-with-hilic-methods\" target=\"_blank\" data-type=\"post\" data-id=\"43644\" rel=\"noreferrer noopener\">How to Avoid Common Problems with HILIC Methods<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/gnss2687\/raptor-hilic-si-simplify-the-switch-to-hilic\" target=\"_blank\" data-type=\"post\" data-id=\"43822\" rel=\"noreferrer noopener\">Simplify the Switch to HILIC with Raptor HILIC-Si Columns<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1793\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1793\" rel=\"noreferrer noopener\">Raptor HILIC-Si S\u00e4ulen<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript&nbsp;<\/h2>\n\n\n\n<p>Da Sie jetzt mit der Methodenentwicklung f\u00fcr die HILIC-Fl\u00fcssigkeitschromatografie anfangen, m\u00fcssen Sie sich bez\u00fcglich der mobilen Phasen entscheiden.<\/p>\n\n\n\n<p>Eine gute HILIC-LC Performance ist abh\u00e4ngig vom Ionisationszustand der station\u00e4ren Phasen und Analyte, der seinerseits vom pH-Wert der mobilen Phasen kontrolliert wird.<\/p>\n\n\n\n<p>F\u00fcr einen schnellen Einstieg empfehlen wir, wenigstens drei w\u00e4ssrige mobile Phasen mit unterschiedlichen pH-Werten herzustellen.<\/p>\n\n\n\n<p>Die erste L\u00f6sung enth\u00e4lt 10 mM Ammoniumformiat und wird mit Ameisens\u00e4urel\u00f6sung auf einen pH-Wert von 3 eingestellt,<\/p>\n\n\n\n<p>die zweite enth\u00e4lt 10 mM Ammoniumacetat und wird mit Essigs\u00e4urel\u00f6sung auf einen pH-Wert von 5 eingestellt,<\/p>\n\n\n\n<p>und die dritte enth\u00e4lt 10 mM Ammoniumacetat und wird mit Essigs\u00e4urel\u00f6sung auf einen pH-Wert von 6.8 eingestellt.<\/p>\n\n\n\n<p>Mithilfe eines isokratischen Laufs oder einer Gradientenelution, die bei 90 oder 95 % Acetonitril anf\u00e4ngt, sollten Sie entscheiden k\u00f6nnen, welche pH-L\u00f6sung besser ist, indem Sie sich einfach die Peakformen der Analyte ansehen.<\/p>\n\n\n\n<p>Nachdem Sie sich f\u00fcr den pH-Wert der mobilen Phase entschieden haben, k\u00f6nnen Sie die Methode durch Einstellung der Pufferkonzentration und des Elutionsprogramms dann weiter optimieren.<\/p>\n\n\n\n<p>Manchmal werden Sie feststellen, dass eine h\u00f6here Pufferkonzentration zu besseren Peakformen f\u00fchrt, aber denken Sie daran, dass das Puffersalz ausgef\u00e4llt werden kann, wenn es mit organischen L\u00f6semitteln in hohen Konzentrationen vermischt wird.<\/p>\n\n\n\n<p>Und in Bezug auf die Gradientenelution empfiehlt es sich, die w\u00e4ssrigen und organischen mobilen Phasen gleicherma\u00dfen zu puffern, um die Ionenst\u00e4rke w\u00e4hrend des Laufs konstant zu halten.<\/p>\n\n\n\n<p>Wenn Sie eine vern\u00fcnftige Wahl f\u00fcr den pH-Wert und die Pufferkonzentration der mobilen Phasen treffen, ist das ein vielversprechender Auftakt.<\/p>\n\n\n\n<p>Wenn Ihnen diese Videos gefallen, denken Sie bitte an die \u201eGef\u00e4llt mir\u201c-Angabe und teilen und abonnieren Sie sie.<\/p>\n\n\n\n<p>Sie k\u00f6nnen das nachstehende Kommentarfeld verwenden, um uns Ihre Ideen f\u00fcr k\u00fcnftige TechTipps mitzuteilen.<\/p>\n\n\n\n<p>Vielen Dank f\u00fcr Ihre Aufmerksamkeit und bis zum n\u00e4chsten Mal.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In diesem Tipp geht es um die Bedeutung von Puffern f\u00fcr HILIC-Trennungen.<\/p>\n","protected":false},"author":11,"featured_media":41433,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2481,2502],"resource-technique":[2326,2355],"ppma_author":[414],"class_list":["post-42580","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-flussigchromatographie-produkte","product-library-mobile-phase-management-flussigchromatographie-produkte","resource-technique-flussigchromatografie","resource-technique-hilic-de"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2502,"label":"Mobile Phase Management"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"},{"value":2355,"label":"HILIC"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4887-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":133,"filter":"raw","cat_ID":772,"category_count":133,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42580","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42580"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42580\/revisions"}],"predecessor-version":[{"id":85782,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42580\/revisions\/85782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41433"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42580"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42580"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42580"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42580"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42580"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42580"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42580"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42580"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42580"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}