{"id":42606,"date":"2018-05-22T04:00:00","date_gmt":"2018-05-22T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/fehlersuche-mit-der-teile-und-herrsche-methode-divide-and-conquer\/"},"modified":"2026-01-28T22:23:53","modified_gmt":"2026-01-28T22:23:53","slug":"fehlersuche-mit-der-teile-und-herrsche-methode-divide-and-conquer","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/videos-de\/gnav4902-de\/fehlersuche-mit-der-teile-und-herrsche-methode-divide-and-conquer","title":{"rendered":"Fehlersuche mit der \u201eTeile-und-Herrsche\u201c-Methode (Divide &#038; Conquer)"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Divide &amp; Conquer Troubleshooting\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/XIRTuso5L-o?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Beschreibung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Das Rezept f\u00fcr eine erfolgreiche Fehlersuche bei der Gaschromatografie ist eine Mischung aus grundlegenden Kenntnissen und der Anwendung n\u00fctzlicher Methoden. Eine der Hauptschwierigkeiten bei der Fehlersuche ist die gro\u00dfe Anzahl an potenziellen Ursachen f\u00fcr Ihr Problem. \u201eTeile-und-Herrsche\u201c ist eine Strategie, mit der sich m\u00f6gliche Ursachen rasch einengen lassen, so dass Sie sich auf das Wesentliche konzentrieren und das Problem identifizieren und beheben k\u00f6nnen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weitere Informationen<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNWC1723.pdf\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNWC1723.pdf\">GC Troubleshooting Poster<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Von Restek empfohlene Tools &amp; Ersatzteile<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1437\" target=\"_blank\" rel=\"noopener\">Tool Kits<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transkript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hallo und herzlich willkommen zu diesem Restek Tipp. Also &#8230;. Ihre Daten oder Ihr Ger\u00e4t (oder beide) signalisieren Ihnen, dass irgendetwas nicht stimmt. Sie m\u00fcssen also eine Fehlersuche durchf\u00fchren. Nun besteht aber der erste Schritt bei jeder Fehlersuche darin, das Problem m\u00f6glichst genau zu beschreiben. Wir alle wissen jedoch, dass ein bestimmtes Problem eine Reihe m\u00f6glicher Ursachen haben k\u00f6nnte. Worauf sollten wir also bei der Fehlersuche unsere Aufmerksamkeit richten? Hier kann uns eine sogenannte \u201eTeile-und-Herrsche\u201c-Methode als Fehlersuchverfahren von gro\u00dfem Nutzen sein.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Stellen Sie sich sowohl Ihr Ger\u00e4t als auch Ihr Verfahren als eine Reihe von Komponenten vor, die zusammen Ihre Daten produzieren. Wenn es Ihnen gelingt, diese Komponenten zu isolieren und sie individuell zu untersuchen, k\u00f6nnen Sie herausfinden, wo Ihr Problem liegt, und Ihre Aufmerksamkeit bei der Fehlersuche entsprechend fokussieren. Lassen Sie mich ein paar Beispiele anf\u00fchren. Angenommen, Sie finden einen unerkl\u00e4rlichen Peak und wissen nicht, woher er stammt. Sie k\u00f6nnten zum Beispiel viel Zeit damit verbringen, Ihre Probenhandhabung und -vorbereitung, und Ihre Spritzen und Ihre Sp\u00fclfl\u00e4schchen zu untersuchen, aber bevor Sie das tun, sollten wir vielleicht herausfinden, ob der Peak im Ger\u00e4t selbst vorliegt, aus dem Ger\u00e4t stammt oder von au\u00dferhalb des Ger\u00e4ts eingebracht wird. Dazu k\u00f6nnten wir beispielsweise einen Ger\u00e4teleerwert bestimmen, indem \u00fcberhaupt nichts injiziert wird. Ist der Peak dann immer noch da, wissen Sie, dass Sie das Problem wahrscheinlich irgendwo am Einlass suchen m\u00fcssen. Ist der Peak nicht mehr vorhanden, m\u00fcssen Sie Ihre Aufmerksamkeit nach au\u00dferhalb des Ger\u00e4tes verlagern.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ein weiteres Beispiel: Angenommen, Sie haben ein Ger\u00e4t mit zwei Kan\u00e4len, in dem beide Kan\u00e4le gleich konfiguriert sind, z. B. mit einem Split\/Splitlos-Injektor an einem FID sowohl vorne als auch hinten. Wenn Sie das Problem vorne vermuten, k\u00f6nnten Sie die Detektorenden der S\u00e4ulen vertauschen, so dass die vordere S\u00e4ule jetzt zum hinteren Detektor f\u00fchrt und die hintere S\u00e4ule an den vorderen Detektor. F\u00fchren Sie die Analyse erneut durch. Wenn das Problem auch weiterhin am vorderen Detektor auftritt, w\u00e4hrend Sie alles andere ge\u00e4ndert haben, sind die Chancen gut, dass dort auch Ihr Problem liegt. Wechselt das Problem aber pl\u00f6tzlich zum hinteren Detektor, denken Sie, \u201eEs ist wahrscheinlich nicht mein Detektor, sondern eher meine S\u00e4ule oder mein Injektor.\u201c Die \u201eTeile-und-Herrsche\u201c-Strategie kann also tats\u00e4chlich helfen Ihre Fehlersuche zu fokussieren. Also viel Gl\u00fcck und vielen Dank f\u00fcr Ihr Interesse am aktuellen Tipp von Restek.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Teile und herrsche&#8221; sollte der Schlachtruf des Chromatografie-Troubleshooters sein. In diesem Video erfahren Sie, wie Sie diese leistungsstarke Technik einsetzen k\u00f6nnen.&#8221;<\/p>\n","protected":false},"author":11,"featured_media":41499,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[772],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2480],"resource-technique":[],"ppma_author":[414],"class_list":["post-42606","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-de","product-library-gaschromatographie-produkte"],"acf":[],"taxonomy_info":{"category":[{"value":772,"label":"Videos"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4902-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":772,"name":"Videos","slug":"videos-de","term_group":0,"term_taxonomy_id":772,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":772,"category_count":139,"category_description":"","cat_name":"Videos","category_nicename":"videos-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42606","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=42606"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42606\/revisions"}],"predecessor-version":[{"id":85788,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/42606\/revisions\/85788"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/41499"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=42606"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=42606"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=42606"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=42606"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=42606"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=42606"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=42606"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=42606"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=42606"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}