{"id":43482,"date":"2021-01-13T00:00:00","date_gmt":"2021-01-13T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/einfache-methode-mit-injektion-groser-volumina-zur-glyphosatanalyse-im-spurenbereich-in-flaschentrinkwasser\/"},"modified":"2026-01-28T22:23:08","modified_gmt":"2026-01-28T22:23:08","slug":"einfache-methode-mit-injektion-groser-volumina-zur-glyphosatanalyse-im-spurenbereich-in-flaschentrinkwasser","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/evfa3196-de\/einfache-methode-mit-injektion-groser-volumina-zur-glyphosatanalyse-im-spurenbereich-in-flaschentrinkwasser","title":{"rendered":"Einfache Methode mit Injektion gro\u00dfer Volumina zur Glyphosatanalyse im Spurenbereich in Flaschentrinkwasser"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Glyphosatanalyse ohne Derivatisierung oder Ionenpaarreagenzien.<\/li>\n\n\n\n<li>Spezielle Raptor Polar X S\u00e4ule bietet gute Retention und effiziente Elution mit besserer Peakform.<\/li>\n\n\n\n<li>Direktinjektion gro\u00dfer Volumina erm\u00f6glicht einfache Erh\u00f6hung der Empfindlichkeit im ppt-Bereich.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Die Analyse von Glyphosat in Wasser stellt eine Herausforderung dar, weil es auf Reversed-Phase-S\u00e4ulen nicht retardiert wird und aufgrund von Chelatbildung mit Metalloberfl\u00e4chen im Probenweg bei LC-MS\/MS-Systemen h\u00e4ufig eine schwache Response zeigt. Derivatisierung und Ionenpaarreagenzien werden oft zur Verbesserung der Performance eingesetzt, k\u00f6nnen das Ger\u00e4t jedoch nachteilig beeinflussen und zus\u00e4tzliche Probenvorbereitungszeit erfordern. Eine bessere Alternative ist die Verwendung einer Raptor Polar X S\u00e4ule, deren neuartige station\u00e4re Phase eine Affinit\u00e4t f\u00fcr polare anionische Verbindungen wie Glyphosat aufweist und sowohl effektive Retention als auch eine effiziente Elution bietet.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In der hier beschriebenen Methode f\u00fcr Glyphosat in Wasser sorgt ein Anionenaustausch in der S\u00e4ule f\u00fcr ausreichende Retention unter den Anfangsbedingungen der mobile Phase, so dass gro\u00dfe Volumina von Flaschentrinkwasser (500 \u00b5L) injiziert werden k\u00f6nnen. Dadurch l\u00e4sst sich die Empfindlichkeit bei niedrigen Konzentrationen auf einfache Weise verbessern. Zur Optimierung des Retentions- und Elutionsverhaltens wurden das Additiv f\u00fcr die mobile Phase und der pH-Wert sorgf\u00e4ltig kontrolliert, um einen Ladungszustand f\u00fcr ausreichende Retention und optimale Empfindlichkeit zu erzielen. Au\u00dferdem lie\u00df sich durch eine einmalige Passivierung des LC-Systems (ohne analytische S\u00e4ule oder Vors\u00e4ule im Flussweg) eine unerw\u00fcnschte Chelatbildung verhindern und es wurde eine gute Response bei 100 ppt beobachtet (Signal-Rausch-Verh\u00e4ltnis &gt;50).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0571.png\" alt=\"Glyphosate in Bottled Drinking Water at 100 ppt on Raptor Polar X by Large Volume Injection Using LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0571<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/L)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Glyphosate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1071-83-6\/Glyphosate\" target=\"_blank\" rel=\"noopener\">Glyphosate<\/a><\/td><td class=\"oth\">6.13<\/td><td class=\"oth\">100<\/td><td class=\"oth\">168.10<\/td><td class=\"oth\">62.95<\/td><td class=\"oth\">78.95<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Polar X  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9311A32\" rel=\"noopener\">cat.# 9311A32<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>30 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Glyphosate (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/32426\" rel=\"noopener\">cat.# 32426<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Direct injection of bottled drinking water fortified at 100 ppt with glyphosate.<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>500 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.5% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Acetonitrile, 0.5% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>1.0<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.0<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>9.0<\/td><td>0.5<\/td><td>90<\/td><td>10<\/td><\/tr><tr><td>9.01<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>10.5<\/td><td>0.5<\/td><td>5<\/td><td>95<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32426<\/li><li>9311A32<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>drinking<\/li><li>glyphosate<\/li><li>injection<\/li><li>large<\/li><li>volume<\/li><li>water<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0571.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Der Nachweis von Glyphosat im Spurenbereich kann ohne komplexe Derivatisierung oder Ionenpaarung durch direkte Injektion von Wasser in gro\u00dfen Mengen auf einer Raptor Polar X-S\u00e4ule erfolgen.<\/p>\n","protected":false},"author":11,"featured_media":6712,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2236],"post-badge":[],"resource-type":[],"product-library":[2481,2499],"resource-technique":[2326,2363],"ppma_author":[414],"class_list":["post-43482","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-lebensmittel-getranke","product-library-flussigchromatographie-produkte","product-library-lc-saulen","resource-technique-flussigchromatografie","resource-technique-ms-ms-de"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"}],"resource-technique":[{"value":2326,"label":"Fl\u00fcssigchromatografie"},{"value":2363,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3196-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":787,"category_count":511,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43482"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43482\/revisions"}],"predecessor-version":[{"id":85786,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43482\/revisions\/85786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/6712"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43482"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43482"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43482"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43482"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43482"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43482"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43482"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}