{"id":43544,"date":"2020-10-22T00:00:00","date_gmt":"2020-10-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/robuste-analyse-der-fettsauren-in-milch-eine-unabhangige-lebensdauerbewertung-von-rt-2560-gc-saulen\/"},"modified":"2026-01-28T22:31:37","modified_gmt":"2026-01-28T22:31:37","slug":"robuste-analyse-der-fettsauren-in-milch-eine-unabhangige-lebensdauerbewertung-von-rt-2560-gc-saulen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/ffar3047-de\/robuste-analyse-der-fettsauren-in-milch-eine-unabhangige-lebensdauerbewertung-von-rt-2560-gc-saulen","title":{"rendered":"Robuste Analyse der Fetts\u00e4uren in Milch: Eine unabh\u00e4ngige Lebensdauerbewertung von Rt-2560 GC-S\u00e4ulen"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Die Pr\u00fcfung der Fetts\u00e4urezusammensetzung ist von allgemeinem Interesse, egal ob es sich um die Charakterisierung von Speise\u00f6len oder um Untersuchungen zu den gesundheitlichen Auswirkungen von Lebensmitteln handelt. In den L\u00e4ndern der Europ\u00e4ischen Union wird enorme Arbeit geleistet, um unser Verst\u00e4ndnis dieser Auswirkungen zu verbessern. Dabei nimmt die Analyse der Fetts\u00e4uren eine zentrale Rolle ein. \u00dcberall in Europa arbeiten Lebensmittelforscher an der Harmonisierung der Methoden und unterst\u00fctzen Vorschriften, die die Unverf\u00e4lschtheit von Speise\u00f6len garantieren. Ein weiteres Ziel ist die Einschr\u00e4nkung des Verzehrs industrieller Transfetts\u00e4uren (TFS), die mit gesundheitssch\u00e4digenden Auswirkungen wie koronare Herzerkrankung in Verbindung gebracht werden [1].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Zur Bestimmung des Fetts\u00e4ureprofils von Lebensmitteln werden h\u00e4ufig 100%ige Biscyanopropyl-Polysiloxan-Kapillars\u00e4ulen wie z. B. eine Rt-2560-S\u00e4ule verwendet. Damit lassen sich Fetts\u00e4uremethylester nach Kettenl\u00e4nge und Grad der Unges\u00e4ttigtheit sowie nach Position und Isomerie der Doppelbindungen trennen. Die Beschichtung einer langen S\u00e4ule mit einer d\u00fcnnen Schicht einer hoch polaren station\u00e4ren Phase ist jedoch extrem schwierig und selbst kleinste Abweichungen bei der Herstellung k\u00f6nnen Qualit\u00e4t und Reproduzierbarkeit nachteilig beeinflussen. Um die Konsistenz der Trennleistung zu gew\u00e4hrleisten, werden Rt-2560-S\u00e4ulen mithilfe eines optimierten Prozesses gefertigt und einer anwendungsspezifischen Qualit\u00e4tskontrollpr\u00fcfung unterzogen [2].<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Auch wenn wir jede Rt-2560-S\u00e4ule in unserem QK-Labor testen, wissen wir die wissenschaftliche Arbeit von Forscherinnen wie Christiane Barthel (Eurofins Analytik GmbH) sehr zu sch\u00e4tzen. Sie f\u00fchrte einen rigorosen Lebensdauertest mit Milchfettproben durch, um herauszufinden, ob die Rt-2560-S\u00e4ule f\u00fcr zuverl\u00e4ssige Pr\u00fcfungen unter realen Bedingungen geeignet ist. Milchfett ist ein besonders komplexes nat\u00fcrliches Fett &nbsp;und eine anspruchsvolle Matrix zur Bewertung der S\u00e4ulenperformance. Die Tests wurden mithilfe einer modifizierten Variante von ISO 12966-2 (Veresterung) zur Probenvorbereitung &nbsp;und anschlie\u00dfender GC-Analyse nach ISO 12966-4 durchgef\u00fchrt. Abbildung 1 zeigt konsistente Retentionszeiten und Trennungen selbst nach 225 Injektionen; ein Beweis f\u00fcr die robuste Performance der Rt-2560-S\u00e4ule zur Analyse von Fetts\u00e4uren in Milchfett.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek bedankt sich bei Frau Barthel und der Eurofins Analytik GmbH f\u00fcr die Durchf\u00fchrung dieser Pr\u00fcfung. Danke auch f\u00fcr die Einbringung ihrer Expertise in die laufenden Bem\u00fchungen zur Gew\u00e4hrleistung der Qualit\u00e4t und Sicherheit von Lebensmitteln weltweit.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 1:<\/strong>\u00a0Rt-2560 GC-S\u00e4ulen zeigen konsistent hervorragende chromatografische Ergebnisse bei der Analyse von Fetts\u00e4uren in Milch.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1291.png\" alt=\"Rt-2560 Lifetime Test\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1291<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rt-2560, 100 m, 0.25 mm ID, 0.20 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13198\" rel=\"noopener\">cat.# 13198<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Customer analysis of milk fat sample<\/td><\/tr>\n<tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 100:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>120 &#176;C to 240 &#176;C at 4 &#176;C\/min (hold 7 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>H<sub>2<\/sub>, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.7 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Sample was prepared following ISO 12966-2 (esterification) and analyzed following ISO 12966-4 using GC-FID.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Acknowledgement<\/th><td>Christiane Bartel, Eurofins Analytik GmbH<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>13198<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>FAMEs<\/li><li>Fatty acid analysis<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1291.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Literatur<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>D. Mozaffarian, A. Aro, W.C. Willet, Health effects of trans-fatty acids: experimental and observational evidence, Eur J Clin Nutr 63(S2) (2009) S5-S21.&nbsp;<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19424218\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/19424218<\/a><\/li>\n\n\n\n<li>K. Sellers, R. Stevens,\u00a0<a href=\"https:\/\/discover.restek.com\/articles\/ffar2589\/highly-reproducible-detailed-cistrans-fames-analysis-ensured-by-new-optimized-rt-2560-column-manufacturing-and-application-specific-qc-test\" data-type=\"post\" data-id=\"43541\">Highly reproducible detailed cis\/trans FAMEs analysis ensured by new optimized Rt-2560 column manufacturing and application-specific QC test<\/a>, Application note, FFAR2589-UNV, Restek Corporation, 2016.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die Analyse von Fetts\u00e4uren in Milchfett ist ein wichtiger Test, und diese anspruchsvolle Matrix wurde von Eurofins Analytik GmbH verwendet, um die Stabilit\u00e4t von Rt-2560-S\u00e4ulen zu bewerten. Selbst nach 225 Injektionen wurden gleichbleibende Retentionszeiten und Trennungen erzielt, was die robuste Leistung der S\u00e4ule belegt.<\/p>\n","protected":false},"author":11,"featured_media":6868,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2236,2237],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324],"ppma_author":[414],"class_list":["post-43544","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-lebensmittel-getranke","industries-application-lebensmittelqualitat","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"},{"value":2237,"label":"Lebensmittelqualit\u00e4t"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAR3047-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":787,"category_count":509,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43544"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43544\/revisions"}],"predecessor-version":[{"id":85801,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43544\/revisions\/85801"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/6868"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43544"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43544"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43544"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43544"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43544"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43544"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}