{"id":43579,"date":"2020-10-21T14:30:00","date_gmt":"2020-10-21T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/lc-ms-ms-analytik-von-mykotoxinen-in-erdnusspulver-in-5-5-minuten\/"},"modified":"2026-02-19T20:40:29","modified_gmt":"2026-02-19T20:40:29","slug":"lc-ms-ms-analytik-von-mykotoxinen-in-erdnusspulver-in-5-5-minuten","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/ffss2971-de\/lc-ms-ms-analytik-von-mykotoxinen-in-erdnusspulver-in-5-5-minuten","title":{"rendered":"LC-MS\/MS-Analytik von Mykotoxinen in Erdnusspulver in 5.5 Minuten"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Schnelle Analytik f\u00fcr h\u00f6heren Probendurchsatz<\/li>\n\n\n\n<li>Ausgezeichnete Trennung verbessert die Genauigkeit f\u00fcr 12 kontrollierte Mykotoxine.<\/li>\n\n\n\n<li>Schnelle und einfache Probenvorbereitung (Verd\u00fcnnen, Filtrieren, Analysieren)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Bestimmte Schimmelpilze, die auf landwirtschaftlichen Produkten wachsen k\u00f6nnen, produzieren toxische Metabolite, die als Mykotoxine bekannt sind. Selbst mit modernen Verfahren der Lebensmittelverarbeitung lassen sich diese Verbindungen nicht vollst\u00e4ndig entfernen, so dass strikte \u00dcberwachungsprotokolle festgelegt wurden. Eine universelle Methode zur Analyse der Mykotoxine w\u00fcrde zwar ein hocheffizientes Screening erm\u00f6glichen, die Entwicklung einer derartigen Methode ist jedoch aufgrund der Unterschiede der physikochemischen Eigenschaften der Mykotoxine, der Extraktionseffizienzen und der Matrixeffekte eine gro\u00dfe Herausforderung. Zhang et al. ver\u00f6ffentlichten eine Multi-Labor-Studie [1] mit dem Ziel, den Laboren ein analytisches Verfahren zur Verf\u00fcgung zu stellen, das zur Analyse einer Vielzahl von Mykotoxinen in unterschiedlichsten Matrices geeignet ist. Aufbauend auf diesen Arbeiten entwickelten wir die folgende LC-MS\/MS-Methode, mit der sich 12 FDA-kontrollierte Mykotoxine innerhalb des Druckbereiches herk\u00f6mmlicher HPLC-Ger\u00e4te trennen lie\u00dfen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Im vorliegenden Beispiel wurden Mykotoxine in einer Erdnusspulver-Matrix analysiert. Die Verwendung einer relativ kurzen S\u00e4ule, die Selektivit\u00e4t der station\u00e4ren Phase (Biphenyl) und die Effizienz der 2.7\u00b5m-Raptor Core-Shell-Partikel erm\u00f6glichten ausgezeichnete Trennungen in einer schnellen Analysenzeit von 5.5 Minuten (bei einer Gesamtzykluszeit von 7 Minuten). Eine koeluierende Matrixverbindung zeigte denselben st\u00e4rksten MRM \u00dcbergang wie Mykotoxin HT-2 (447.3-285.3), so dass ein weniger empfindlicher \u00dcbergang (447.3-345.3) zur quantitativen Bestimmung ausgew\u00e4hlt wurde. Zur Erh\u00f6hung der Empfindlichkeit wurde ein Ammoniumpuffer verwendet, um eine bessere Ionisierung der Mykotoxine zu f\u00f6rdern. Die Raptor Biphenyl S\u00e4ule eignete sich sehr gut f\u00fcr die 12 Mykotoxine, die in der zitierten Studie untersucht wurden. F\u00fcr erweiterte Listen von Substanzen, die isobare Mykotoxine \u00e4hnlicher Strukturen enthalten, ist m\u00f6glicherweise die Raptor FluoroPhenyl Phase erforderlich, um ausreichende chromatografische Aufl\u00f6sung zu erzielen. Die passende Selektivit\u00e4t der Raptor FluoroPhenyl-S\u00e4ule wurde in einer&nbsp;<a href=\"https:\/\/discover.restek.com\/articles\/ffss2790\/highly-selective-lc-msms-analysis-of-mycotoxins-from-multiple-classes\" data-type=\"post\" data-id=\"43565\">Analyse von 20 Mykotoxinen<\/a>&nbsp;unter Beweis gestellt.<br><br>Die vorliegende Methode zeigte ausgezeichnete Pr\u00e4zision und Richtigkeit f\u00fcr die 12 FDA-kontrollierten Mykotoxine, die im Rahmen einer Validierungsstudie mit einer Vielzahl von Matrices untersucht wurden (darunter verschiedene Quellen von Maismehl und braunem Reismehl neben dem hier gezeigten Erdnusspulver). Restek m\u00f6chte sich bei Dr. Zhang f\u00fcr seine technische Unterst\u00fctzung bei diesem Projekt bedanken.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0526.png\" alt=\"Mycotoxins in Peanut Powder on Raptor Biphenyl by LC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0526<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/g)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51481-10-8\/Deoxynivalenol\" target=\"_blank\" rel=\"noopener\">Deoxynivalenol<\/a><\/td><td class=\"oth\">0.62<\/td><td class=\"oth\">50<\/td><td class=\"oth\">297.3<\/td><td class=\"oth\">249.3<\/td><td class=\"oth\">231.2<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-83-0\/Fumonisin B1\" target=\"_blank\" rel=\"noopener\">Fumonisin B1<\/a><\/td><td class=\"oth\">2.45<\/td><td class=\"oth\">50<\/td><td class=\"oth\">722.5<\/td><td class=\"oth\">352.4<\/td><td class=\"oth\">334.5<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for HT-2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26934-87-2\/HT-2\" target=\"_blank\" rel=\"noopener\">HT-2<\/a><\/td><td class=\"oth\">2.60<\/td><td class=\"oth\">50<\/td><td class=\"oth\">447.3<\/td><td class=\"oth\">345.3<\/td><td class=\"oth\">285.3<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1422359-85-0\/Fumonisin B3\" target=\"_blank\" rel=\"noopener\">Fumonisin B3<\/a><\/td><td class=\"oth\">2.85<\/td><td class=\"oth\">50<\/td><td class=\"oth\">706.5<\/td><td class=\"oth\">336.4<\/td><td class=\"oth\">318.4<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-84-1\/Fumonisin B2\" target=\"_blank\" rel=\"noopener\">Fumonisin B2<\/a><\/td><td class=\"oth\">3.23<\/td><td class=\"oth\">50<\/td><td class=\"oth\">706.5<\/td><td class=\"oth\">336.3<\/td><td class=\"oth\">141.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for T2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-31-7\/T2\" target=\"_blank\" rel=\"noopener\">T2<\/a><\/td><td class=\"oth\">3.31<\/td><td class=\"oth\">50<\/td><td class=\"oth\">489.3<\/td><td class=\"oth\">245.2<\/td><td class=\"oth\">387.4<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/g)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7241-98-7\/Aflatoxin G2\" target=\"_blank\" rel=\"noopener\">Aflatoxin G2<\/a><\/td><td class=\"oth\">3.74<\/td><td class=\"oth\">5<\/td><td class=\"oth\">331.2<\/td><td class=\"oth\">313.3<\/td><td class=\"oth\">189.3<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zearalenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17924-92-4\/Zearalenone\" target=\"_blank\" rel=\"noopener\">Zearalenone<\/a><\/td><td class=\"oth\">3.96<\/td><td class=\"oth\">50<\/td><td class=\"oth\">319.3<\/td><td class=\"oth\">283.3<\/td><td class=\"oth\">187.2<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1165-39-5\/Aflatoxin G1\" target=\"_blank\" rel=\"noopener\">Aflatoxin G1<\/a><\/td><td class=\"oth\">4.22<\/td><td class=\"oth\">5<\/td><td class=\"oth\">329.2<\/td><td class=\"oth\">243.2<\/td><td class=\"oth\">200.2<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7220-81-7\/Aflatoxin B2\" target=\"_blank\" rel=\"noopener\">Aflatoxin B2<\/a><\/td><td class=\"oth\">4.43<\/td><td class=\"oth\">5<\/td><td class=\"oth\">315.3<\/td><td class=\"oth\">287.3<\/td><td class=\"oth\">259.2<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1162-65-8\/Aflatoxin B1\" target=\"_blank\" rel=\"noopener\">Aflatoxin B1<\/a><\/td><td class=\"oth\">4.99<\/td><td class=\"oth\">5<\/td><td class=\"oth\">313.3<\/td><td class=\"oth\">285.2<\/td><td class=\"oth\">241.2<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ochratoxin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-47-9\/Ochratoxin A\" target=\"_blank\" rel=\"noopener\">Ochratoxin A<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">5<\/td><td class=\"oth\">404.2<\/td><td class=\"oth\">239.3<\/td><td class=\"oth\">358.3<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">Matrix interference was observed for HT-2 transition 447.3-285.3 in peanut powder. Therefore, 447.3-345.3 was chose for quantification.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A52\" rel=\"noopener\">cat.# 9309A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor Biphenyl EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A0252\" rel=\"noopener\">cat.# 9309A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><th>%C<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><td><\/td><\/tr><tr><td>0.6<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><td><\/td><\/tr><tr><td>0.7<\/td><td>0.5<\/td><td>50<\/td><td>50<\/td><td><\/td><\/tr><tr><td>3.0<\/td><td>0.5<\/td><td>25<\/td><td>70<\/td><td><\/td><\/tr><tr><td>4.5<\/td><td>0.5<\/td><td>25<\/td><td>75<\/td><td><\/td><\/tr><tr><td>5.0<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><td><\/td><\/tr><tr><td>5.2<\/td><td>0.5<\/td><td>10<\/td><td>90<\/td><td><\/td><\/tr><tr><td>5.21<\/td><td>0.5<\/td><td>25<\/td><td>75<\/td><td><\/td><\/tr><tr><td>6.00<\/td><td>0.5<\/td><td>25<\/td><td>75<\/td><td><\/td><\/tr><tr><td>6.01<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><td><\/td><\/tr><tr><td>7.00<\/td><td>0.5<\/td><td>70<\/td><td>30<\/td><td> <\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Weighed 1.00 gram of peanut powder in a 50 mL centrifuge tube and added 2.00 mL of water. Vortexed at 3000 rpm for 5 min followed by the addition of 4.0 mL of extraction solvent (50:50 water:acetonitrile, v\/v). The tube was then vortexed at 3000 rpm for 5 min followed by centrifugation for 15 min at 4200 rpm. 475 \u03bcL of the supernatant was filtered through a Thomson SINGLE StEP Nano filter vial (0.2 \u03bcm). The sample was then fortified with 25 \u03bcL of a standard solution prepared in water at 1000 ng\/mL (100 ng\/mL for aflatoxins and ochratoxin A) as part of the matrix-matched calibration curve. Vortexed at 3000 rpm for 1 min prior to analysis.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Want even better performance when analyzing metal-sensitive compounds? Check out Inert LC columns at <a href=\"https:\/\/www.restek.com\/inert\" target=\"_blank\" rel=\"noopener\">www.restek.com\/inert<\/a>. <\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A52<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Mycotoxins<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0526.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Literatur<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>K. Zhang, M.R. Schaab, G. Southwood, E.R. Tor, L.S. Aston, W. Song, B. Eitzer, S. Majumdar, T. Lapainis, H. Mai, K. Tran, A. El-Demerdash, V. Vega, Y. Cai, J.W. Wong, A.J. Krynitsky, T.H. Begley, A collaborative study: determination of mycotoxins in corn, peanut butter, and wheat flour using stable isotope dilution assay (SIDA) and liquid chromatography-tandem mass spectrometry (LC-MS\/MS), Journal of Agricultural and Food Chemistry, 65 (33) (2017) 7138-7152.&nbsp;<a href=\"https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27983809\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27983809<\/a>.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Verwandte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9319A12\">                                Art.-Nr. 9319A12                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100&#215;2.1 mm HPLC-S\u00e4ule<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9319A12\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9319A0252\">                                Art.-Nr. 9319A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl EXP Vors\u00e4ulenkartusche, 2.7 \u00b5m, 5 x 2.1 mm, 3er Pack<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9319A0252\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25808\">                                Art.-Nr. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect-Halter f\u00fcr EXP Vors\u00e4ulenkartuschen, enth\u00e4lt Fittings und Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25808\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25937\">                                Art.-Nr. 25937                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Finger-Tight-Fitting (Nut mit Ferrule)<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25937\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die hier entwickelte Methode erm\u00f6glicht eine schnelle Analyse von Mykotoxinen in Erdnusspulver. Die Trennung von 12 FDA- und EU-regulierten Mykotoxinen wurde in einer 5,5-min\u00fctigen Analyse (7 Minuten Gesamtzykluszeit) erreicht. Diese Methode kann auf verschiedene Matrices angewendet werden, wobei entweder eine matrixangepasste Kalibrierung oder ein Assay mit stabiler Isotopenverd\u00fcnnung verwendet wird. Der Probendurchsatz kann durch die kurze Zykluszeit f\u00fcr jeden Lauf erheblich gesteigert werden.<\/p>\n","protected":false},"author":11,"featured_media":6925,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-43579","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFSS2971-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":787,"category_count":510,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43579","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43579"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43579\/revisions"}],"predecessor-version":[{"id":87963,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43579\/revisions\/87963"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/6925"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43579"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43579"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43579"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43579"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43579"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43579"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43579"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43579"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43579"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}