{"id":43625,"date":"2021-06-25T14:30:00","date_gmt":"2021-06-25T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/revive-in-line-sample-preparation-ilsp-a-faster-approach-for-multiresidue-pesticides-in-food\/"},"modified":"2026-08-11T15:26:57","modified_gmt":"2026-08-11T15:26:57","slug":"revive-in-line-sample-preparation-ilsp-a-faster-approach-for-multiresidue-pesticides-in-food","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/articles\/fsss3549\/revive-in-line-sample-preparation-ilsp-a-faster-approach-for-multiresidue-pesticides-in-food","title":{"rendered":"Revive In-Line Sample Preparation (ILSP): A Faster Approach for Multiresidue Pesticides in Food"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Automated, in-line sample extract cleanup dramatically reduces sample preparation time.<\/li>\n\n\n\n<li>Simultaneous analysis and ILSP cartridge wash eliminate downtime between samples.<\/li>\n\n\n\n<li>Fast, simple alternative to QuEChERS or SPE for multiresidue pesticides analysis in foods.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">In-line sample preparation (ILSP) is an ideal sample preparation technique for food safety labs seeking to spend less time and money per LC-MS\/MS sample without sacrificing performance. A Revive ILSP Pesticides cartridge separates analytes from potentially interfering matrix components just like conventional SPE and QuEChERS methods do, but it replaces time-consuming manual procedures with an automated cleanup process that occurs on the instrument <em>in line<\/em>&nbsp;with the analytical sample flow path. Because Revive ILSP Pesticides cartridges leverage effective retention mechanisms (e.g., reversed-phase interactions) and efficient particle design, they provide a powerful, automated, chromatographic cleanup of complex samples that occurs on the instrument concurrent with sample analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As an example of the benefits of in-line sample preparation, Figure 1 compares a Revive ILSP Pesticides workflow and a typical QuEChERS workflow for the analysis of pesticide residues in spinach. The ISLP approach resulted in a time savings of 1.5 hours with fewer sample transfers, providing a significant leap forward in sample preparation productivity. ILSP also minimizes the risk of introducing error through manual steps and provides equivalent or superior analytical results compared to QuEChERS. An exhaustive study of this comparison has been published by Lupo, et al. [1].<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0Revive in-line sample preparation is 1.5 hours faster than a traditional QuEChERS workflow for 14 spinach samples.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43625_220840-b6 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43625_220840-b6\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"996\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-768x996.jpg\" alt=\"\" class=\"kb-img wp-image-20254\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-768x996.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-231x300.jpg 231w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-790x1024.jpg 790w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-1185x1536.jpg 1185w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01-1579x2048.jpg 1579w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-01.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">How Revive In-Line Sample Preparation Works<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As shown in Figure 2, Revive ILSP incorporates a sample cleanup cartridge directly into the LC injection flow path. Once the analytes reach the analytical column, the ILSP cleanup cartridge is then backflushed or \u201crevived,\u201d preparing it for the next injection while the first sample is analyzed. Concurrent regeneration and analysis are made possible using a six-port valve and a standard independent isocratic pump. Detailed guidance on instrument configuration, setting method parameters (e.g., valve timing and rinse solvent flow rate), and identifying an effective rinse solvent are given in&nbsp;<a href=\"https:\/\/discover.restek.com\/fsar3550\/in-line-sample-preparation-method-development\/\" data-type=\"post\" data-id=\"43593\">Restek\u2019s ILSP Method Development Guidelines document<\/a>. The day-to-day savings in operating costs will quickly pay for the investment in a pump and time spent setting up the method, especially for labs with high volumes of samples or limited sample preparation resources.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0How In-Line Sample Preparation Works<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43625_e1ce1c-d9 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43625_e1ce1c-d9\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"897\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02-1024x897.jpg\" alt=\"\" class=\"kb-img wp-image-20266\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02-1024x897.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02-300x263.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02-768x672.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02-1536x1345.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Consistent, Cost-Effective Results Over Long Lifetimes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Beyond time savings, a lifetime experiment conducted using 300 injections of avocado extracts provides an excellent example of the consistent results and substantial cost savings that ILSP also offers. Avocado, a high-fat commodity, was fortified with a representative mix of 61 pesticides that ranged in chemical characteristics and retention times. Samples were then extracted and analyzed using the optimized workflow shown in Figure 3. The in-line sample preparation method was significantly faster than a comparable QuEChERS avocado workflow, and a single Revive ILSP Pesticides cartridge provided effective cleanup and consistent chromatographic results over the duration of the experiment.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong>\u00a0An example in-line sample preparation workflow for high-fat avocado samples.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43625_5c719d-f9 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43625_5c719d-f9\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"691\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03-768x691.jpg\" alt=\"\" class=\"kb-img wp-image-20278\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03-768x691.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03-300x270.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03-1024x922.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03-1536x1382.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSSS3549-03.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">In addition to speed gains and robust performance, ILSP also offers significant cost savings. For example, if we assume a $4 per sample cost for each QuEChERS sample (extraction salts packet and dSPE tube), the 300 avocado samples would have cost $1200 in QuEChERS products alone. The Revive in-line sample preparation workflow uses a simple liquid-solid extraction without extraction salts or dSPE, which eliminates that cost. A single Revive ILSP Pesticides cartridge, which costs approximately a quarter of the total QuEChERS price, effectively cleaned the 300 avocado samples, and since its performance had not degraded after 300 injections, replacing the cartridge was not necessary when the experiment ended.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0Consistent chromatography even after 300 avocado matrix injections on a single Revive ILSP cartridge.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0584.png\" alt=\"ILSP Lifetime Study with Avocado\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FF0584<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/g)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imidacloprid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/138261-41-3\/Imidacloprid\" target=\"_blank\" rel=\"noopener\">Imidacloprid<\/a><\/td><td class=\"oth\">2.678<\/td><td class=\"oth\">50<\/td><td class=\"oth\">256.1<\/td><td class=\"oth\">175.0<\/td><td class=\"oth\">209.0<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenhexamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126833-17-8\/Fenhexamid\" target=\"_blank\" rel=\"noopener\">Fenhexamid<\/a><\/td><td class=\"oth\">4.557<\/td><td class=\"oth\">50<\/td><td class=\"oth\">302.1<\/td><td class=\"oth\">97.1<\/td><td class=\"oth\">55.05<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Eprinomectin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123997-26-2\/Eprinomectin\" target=\"_blank\" rel=\"noopener\">Eprinomectin<\/a><\/td><td class=\"oth\">6.396<\/td><td class=\"oth\">50<\/td><td class=\"oth\">914.6<\/td><td class=\"oth\">186.1<\/td><td class=\"oth\">154.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor ARC-18  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A12\" rel=\"noopener\">cat.# 9314A12<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor ARC-18 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A0252\" rel=\"noopener\">cat.# 9314A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>50 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile, 0.1% acetic acid<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>3 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.2% formic acid, 2 mM ammonium formate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.2% formic acid, 2 mM ammonium formate <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">C:<\/th><td>Methanol, 0.2% formic acid, 10 mM ammonium formate <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>2<\/td><td>0.4<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>4<\/td><td>0.4<\/td><td>25<\/td><td>75<\/td><\/tr><tr><td>6<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>8<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>8.01<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>10<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>UHPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td><i>Sample Fortification and Extraction<\/i><br \/>Avocado was peeled and homogenized, and 5 g of sample was weighed into a 50 mL polypropylene tube. 10 mL of acetonitrile containing 0.1% acetic acid was added to the sample and vortexed. Samples were shaken on a shaker table for 10 minutes and then centrifuged at 4200 rpm for 10 minutes. An aliquot was transferred to a vial and fortified with analytes for a final concentration of 50 ng\/g. The sample was vortexed, and an aliquot transferred to a 0.2 \u03bcm PTFE Thomson filter vial cat.# 25893 and filtered prior to injection. <br \/><br \/><i>In-Line Sample Preparation (ILSP)<\/i><br \/>The UHPLC system was equipped with an auxiliary pump; 6-port, high-pressure switching valve; and dual-directional 5 x 2.1 mm Revive ILSP Pesticides cartridge and holder (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/27882\" rel=\"noopener\">cat.# 27882<\/a>). At 5.5 min, after the target compounds had all eluted from the ILSP cartridge and were undergoing analysis, valve switching was used as described below to flush the ILSP cartridge and wash trapped matrix components to waste. At 7.0 min, the original valve configuration, where the ILSP cartridge is in-line with the analytical column, was restored and the system was brought back to equilibrium prior to the next injection.<br \/>\u2022 0 min; valve position 0<br \/>\u2022 0 min; C flow= 0 mL\/min<br \/>\u2022 5.49 min; C flow= 0 mL\/min<br \/>\u2022 5.5 min; valve position 1<br \/>\u2022 5.5 min; C flow= 1 mL\/min<br \/>\u2022 6.9 min; C flow=1 mL\/min<br \/>\u2022 7 min; C flow= 0 mL\/min<br \/>\u2022 7 min; valve position 0<br \/><br \/><\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Thomson SINGLE StEP standard filter vials cat.# 25893 were used to produce this chromatogram, but have since been discontinued. For assistance choosing a replacement for this application, contact Restek Technical Service or your local Restek representative.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9314A0252<\/li><li>9314A12<\/li><li>27882<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ff0584.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Revive ILSP in Action: Multiresidue Pesticide Analysis in Disparate Foods<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Analyzing pesticides in food commodities is particularly challenging due to the wide range of analyte chemistries and matrix types (high fat, high sugar, high pigmentation, low water, etc.) To address this, a variety of QuEChERS products have been formulated to ensure effective extraction and cleanup for different situations. However, a single Revive ILSP Pesticides cartridge can provide excellent results across the same wide range of analytes and matrices.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To demonstrate this broad applicability, a recovery study was performed using in-line sample preparation methods that were developed for six commodities spanning five of the commodity groups in the SANTE\/12682\/2019 guidelines (Table I). These foods were fortified with 61 pesticides representing a variety of compound chemistries that elute at different points (early, mid, late) across a typical multiresidue pesticide screening method chromatogram (Table II).&nbsp;<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Table I:<\/strong>&nbsp;Commodities used to develop Revive ILSP methods.<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Commodity Group<\/strong><\/td><td><strong>Food Sample<\/strong><\/td><\/tr><tr><td>High water and high pigment content<\/td><td>Spinach<\/td><\/tr><tr><td>High acid content and high water content<\/td><td>Whole orange<\/td><\/tr><tr><td>High lipid content and very low water content<\/td><td>Soybean meal<\/td><\/tr><tr><td>High lipid content and intermediate water content<\/td><td>Avocado<\/td><\/tr><tr><td rowspan=\"2\">&#8220;Difficult or unique commodities&#8221;<\/td><td>Hibiscus tea<\/td><\/tr><tr><td>Black tea<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Table II:<\/strong>&nbsp;Revive ILSP recovery experiments were performed using 61 pesticides that differed in both chemical characteristics and elution time (early, mid, late) in typical multiresidue pesticide screening methods.<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"3\"><strong>List of Monitored Pesticides<\/strong><\/td><\/tr><tr><td>Cyromazine<\/td><td>Flutolanil<\/td><td>Benzoximate<\/td><\/tr><tr><td>Dinotefuran<\/td><td>Mepronil<\/td><td>Trifloxystrobin<\/td><\/tr><tr><td>Nitenpyram<\/td><td>Myclobutanil<\/td><td>Metaflumizone<\/td><\/tr><tr><td>Imidacloprid<\/td><td>Methoxyfenozide<\/td><td>Fluazinam<\/td><\/tr><tr><td>Acetamiprid<\/td><td>Triadimefon<\/td><td>Tebufenpyrad<\/td><\/tr><tr><td>Oxadixyl<\/td><td>Mepanipyrim<\/td><td>Pyriproxyfen<\/td><\/tr><tr><td>Carbetamide<\/td><td>Fluoxastrobin<\/td><td>Piperonyl Butoxide<\/td><\/tr><tr><td>Pyracarbolid<\/td><td>Fenhexamid<\/td><td>Quinoxyfen<\/td><\/tr><tr><td>Secbumeton<\/td><td>Butafenacil<\/td><td>Amitraz<\/td><\/tr><tr><td>Prometon<\/td><td>Cyprodinil<\/td><td>Fenpyroximate<\/td><\/tr><tr><td>Terbumeton<\/td><td>Picoxystrobin<\/td><td>Eprinomectin<\/td><\/tr><tr><td>Ametryn<\/td><td>Rotenone<\/td><td>Abamectin B1a<\/td><\/tr><tr><td>Metalaxyl<\/td><td>Tebufenozide<\/td><td>Fenazaquin<\/td><\/tr><tr><td>Chlorantraniliprole<\/td><td>Dimoxystrobin<\/td><td>Doramectin<\/td><\/tr><tr><td>Pyrimethanil<\/td><td>Carfentrazone-ethyl +NH4<\/td><td>Ivermectin<\/td><\/tr><tr><td>Spiroxamine<\/td><td>Kresoxym-methyl<\/td><td>Moxidectin<\/td><\/tr><tr><td>Azoxystrobin<\/td><td>Zoxamide<\/td><td>Imazalil<\/td><\/tr><tr><td>Halofenozide<\/td><td>Famoxadone<\/td><td>Pymetrozine<\/td><\/tr><tr><td>Furalaxyl<\/td><td>Benalaxyl<\/td><td>Fludioxinol<\/td><\/tr><tr><td>Boscalid<\/td><td>Clofentezine<\/td><td>&nbsp;<\/td><\/tr><tr><td>Mandipropamid<\/td><td>Prochloraz<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">ILSP Sample Extraction<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">For Revive ILSP extraction, sample homogenization followed by a liquid-solid extraction worked well for all commodities studied. The exact extraction parameters (solvent, volume, shake time, filtration, etc.) were optimized for each commodity, but the overall procedure was simple, quick, and effective: homogenization, solvent addition, agitation, followed by sample filtration, if necessary. In addition, because there is no dispersive cleanup step as is typical of QuEChERS methods, in-line sample preparation methods minimize analyte loss during cleanup.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">ILSP Recoveries Across Various Commodity Group<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nearly all of the pesticides studied were recovered from all six different matrices within the performance guidelines provided by SANTE\/12682\/2019 using an LC-MS\/MS with low-to-mid range sensitivity (Table III). These results demonstrate the broad applicability of Revive in-line sample preparation for multiresidue pesticide monitoring in food and feed commodities.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition, when Revive ILSP was compared to analogous QuEChERS methods, ILSP performed comparably, if not better, in all cases. And, for instances when compounds fell outside the ideal 70-120% recovery range, guidelines like SANTE\/12682\/2019 provide provisions for reporting that data, if the results are consistent, as is the case with ILSP\u2019s automated and reproducible cleanup.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Table III:<\/strong>&nbsp;Total recovery performance for Revive ILSP methods developed for six disparate food commodities.<\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Commodity<\/strong><\/td><td><strong>Percentage of Compounds with 70-120% Recovery &amp; \u2264 20% RSD (Concentration)<\/strong><\/td><\/tr><tr><td>Spinach<\/td><td>85.7% (5 ng\/g); 95.2% (100 ng\/g)<\/td><\/tr><tr><td>Whole Orange<\/td><td>87% (10 ng\/g)<\/td><\/tr><tr><td>Soybean Meal<\/td><td>97% (10 ng\/g)<\/td><\/tr><tr><td>Avocado<\/td><td>95% (10 ng\/g)<\/td><\/tr><tr><td>Hibiscus Tea<\/td><td>92% (10 ng\/g)<\/td><\/tr><tr><td>Black Tea<\/td><td>98% (10 ng\/g)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Matrix Effects and ILSP<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">As in any analysis of real-world samples, some matrix components will likely be extracted along with the target analytes. In this regard, ILSP is no different than any other sample preparation technique and using matrix-matched calibration standards is the best way to assure accurate quantitation. This is particularly true for compounds that elute early in the run where unretained matrix components are most likely to appear and cause enhancement or suppression.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to affecting quantitation, matrix components can contaminate instruments. With in-line sample preparation methods, uncleaned extracts are being injected, so it is important to ensure that internal and external needle rinses are performed between injections to avoid carryover between samples and prevent buildup that could require instrument downtime to remove.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Revive In-Line Sample Preparation: A Faster Approach for Multiresidue Pesticides in Food<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In-line sample preparation uses the power of your LC-MS\/MS to streamline and automate sample extract cleanup. With a Revive ILSP Pesticides cartridge, six-port valve, and an independent isocratic pump, your instrument can be transformed into an analytical workhorse, combining sample cleanup and analysis in a single, efficient method. Decrease sample preparation time, cut the costs associated with disposable sample prep products, and reduce errors related to manual procedures by integrating Revive ILSP into your current methods for multiresidue pesticide analysis in foods.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>References<\/strong><\/h5>\n\n\n\n<ol class=\"wp-block-list\">\n<li>A. Lupo, R.L. Romesberg, X. Lu, Automated inline pigment removal for the analysis of pesticide residues in spinach by liquid chromatography tandem mass spectrometry, J. Chromatogr. A 1629 (2020) 461477.&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.chroma.2020.461477\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.chroma.2020.461477<\/a><\/li>\n\n\n\n<li>EU Reference Laboratories for Residues of Pesticides, SANTE\/2019\/12682, Analytical quality control and method validation procedures for pesticide residues analysis in food and feed (2020).&nbsp;<a href=\"https:\/\/www.eurl-pesticides.eu\/userfiles\/file\/EurlALL\/AqcGuidance_SANTE_2019_12682.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.eurl-pesticides.eu\/userfiles\/file\/EurlALL\/AqcGuidance_SANTE_2019_12682.pdf<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Revive in-line sample preparation combines an automated sample cleanup with concurrent analysis, significantly speeding up LC-MS\/MS multiresidue pesticide analysis in food.<\/p>\n","protected":false},"author":11,"featured_media":7063,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2784],"tags":[],"industries-application":[2167,2169],"post-badge":[],"resource-type":[],"product-library":[2401,2375],"resource-technique":[2299],"ppma_author":[414],"class_list":["post-43625","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles","industries-application-food-beverage","industries-application-food-safety","product-library-in-line-sample-preparation-ilsp","product-library-sample-preparation-products","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":2784,"label":"Articles"}],"industries-application":[{"value":2167,"label":"Food &amp; Beverage"},{"value":2169,"label":"Food Safety"}],"product-library":[{"value":2401,"label":"In-Line Sample Preparation (ILSP)"},{"value":2375,"label":"Sample Preparation Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSSS3549-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2784,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":2784,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":2784,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43625"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43625\/revisions"}],"predecessor-version":[{"id":85584,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43625\/revisions\/85584"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/7063"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43625"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43625"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43625"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43625"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43625"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43625"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43625"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43625"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}