{"id":43820,"date":"2020-11-18T00:00:00","date_gmt":"2020-11-18T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/set-your-sights-on-superior-performance\/"},"modified":"2026-09-25T17:58:40","modified_gmt":"2026-09-25T17:58:40","slug":"set-your-sights-on-superior-performance","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/articoli\/gnss2642\/set-your-sights-on-superior-performance","title":{"rendered":"PAL Smart SPME Arrow"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Rugged, stainless-steel construction ensures longer lifetimes.<\/li>\n\n\n\n<li>Faster extraction means higher sample throughput.<\/li>\n\n\n\n<li>Better sensitivity allows lower LODs.<\/li>\n\n\n\n<li>Choose format based on sampling technique:\n<ul class=\"wp-block-list\">\n<li>1.1 mm sleeve, if only using headspace sampling.<\/li>\n\n\n\n<li>1.5 mm wide sleeve, if using direct immersion sampling (works for headspace, too).<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Now with Smart technology\u2014each SPME Arrow is equipped with a unique Smart chip containing parameters, ranges, and usage history.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Solid phase microextraction (SPME) is a fast, automated sample preparation technology that reduces sample handling, extraction time, and solvent consumption, making it a popular choice in environmental, food, and clinical laboratories. However, traditional SPME fiber technology has some significant drawbacks, including poor mechanical stability and a small phase volume.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The PAL Smart SPME Arrow system is a revolutionary change in microextraction that combines exceptional robustness with faster extraction times and trace-level sensitivity (Table I). In contrast to traditional SPME fibers, SPME Arrows contain significantly more phase volume, which allows more target analyte to be extracted in less time. In addition, the stainless-steel construction, unique Arrow tip, inner stabilizing rod, and outer sheath design fully protect the phase, minimizing both mechanical damage and analyte loss during sample transfer.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong>&nbsp;Comparing Restek PAL SPME Arrow to Traditional SPME Fiber (Headspace Technique)<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><tbody><tr><td>&nbsp;<\/td><td><strong>Traditional Fibers<\/strong><\/td><td><strong>1.1 mm Arrow<\/strong><\/td><td><strong>1.5 mm Arrow<\/strong><\/td><td><strong>The Arrow Advantage<\/strong><\/td><\/tr><tr><td><strong>Rugged, stainless-steel construction<\/strong> Protective sheath Stabilizing inner rod Arrow-shaped tip<\/td><td>No<\/td><td>Yes<\/td><td>Yes<\/td><td><strong>Longer lifetimes:<\/strong>&nbsp;Arrow construction protects the phase and minimizes both damage and analyte loss. <br><br><strong>Less downtime<\/strong>&nbsp;due to breakage. <br><br><strong>Eliminates septa coring.<\/strong> &nbsp;<\/td><\/tr><tr><td><strong>Surface area<\/strong><\/td><td>9.4 mm<sup>2<\/sup><\/td><td>44 mm<sup>2<\/sup><\/td><td>63 mm<sup>2<\/sup><\/td><td>Increase sample throughput\u2014higher surface area lets you reduce extraction time and&nbsp;<strong>analyze more samples per shift.<\/strong><\/td><\/tr><tr><td><strong>Phase (PDMS) volume<\/strong><\/td><td>0.6 \u03bcL<\/td><td>3.8 \u03bcL<\/td><td>12 \u03bcL<\/td><td>With significantly more phase, SPME Arrow provides better sensitivity so you can&nbsp;<strong>lower detection limits with confidence.<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">On Target: Longer Lifetime<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">One of the main drawbacks to SPME fibers is their fragility. Even during routine use, they are easily damaged and can be irreparably broken (Figure 1). Busy labs will benefit greatly from the reliability of the rugged Restek PAL Smart SPME Arrow. The unique, stainless-steel Arrow design includes a robust inner stabilizing rod that resists bending and breakage as well as an outer sheath that protects the phase coating and prevents both physical damage and analyte loss. Typically, SPME Arrows perform well for hundreds of extractions, lasting two to three times longer than traditional SPME fibers. In addition, the unique arrow-shaped tip pierces the septum cleanly and with little resistance, extending septum lifetime (Figure 2).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong>\u00a0SPME fibers break easily during routine operation.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43820_86806f-a7 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43820_86806f-a7\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"642\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01-1024x642.jpg\" alt=\"\" class=\"kb-img wp-image-23218\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01-1024x642.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01-300x188.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01-768x481.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01-1536x963.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong>\u00a0The rugged construction of the Restek PAL SPME Arrow prevents breakage under normal use.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43820_1300d5-05 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43820_1300d5-05\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"642\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02-1024x642.jpg\" alt=\"\" class=\"kb-img wp-image-23224\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02-1024x642.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02-300x188.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02-768x481.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02-1536x963.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642E-02.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<h2 class=\"wp-block-heading\">Which Restek PAL SPME Arrow is best for my application?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PAL Smart SPME Arrows are suitable for a wide range of analyte chemistries and sample matrices. They are suitable for manual injection and are fully backwards compatible with any generation of PAL3 Systems. Choose the best SPME Arrow for your application based on the properties of your target compounds. Note that a <a href=\"https:\/\/www.restek.com\/c\/1353\" target=\"_blank\" rel=\"noopener\">GC inlet conversion kit<\/a>&nbsp;is required in order to use a Restek PAL SPME Arrow.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Trace analysis in foodstuffs<\/li>\n\n\n\n<li>Drugs and pharmaceuticals<\/li>\n\n\n\n<li>Herbicides\/pesticides<\/li>\n\n\n\n<li>Medical diagnostics<\/li>\n\n\n\n<li>Trace impurities in polymers and solid samples<\/li>\n\n\n\n<li>Solvent residues in raw materials<\/li>\n\n\n\n<li>Water analysis (organics in water)<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Analytes<sup>*<\/sup><\/strong><\/td><td><strong>Molecular Weight<sup>\u2020<\/sup><\/strong><\/td><td><strong>Material<\/strong><\/td><td><strong>Thickness (\u00b5m)<\/strong><\/td><td><strong>Needle Diameter (mm)<\/strong><\/td><td><strong>Hub Color<\/strong><\/td><td><strong>Smart SPME Arrow<br>Each (cat.#)<\/strong><\/td><td><strong>Smart SPME Arrow<br>3-pk (cat.#)<\/strong><\/td><\/tr><tr><td>Volatile<\/td><td>60\u2013275<\/td><td>Polydimethylsiloxane (PDMS)<\/td><td>100<\/td><td>1.1<\/td><td>Red<\/td><td><a href=\"p\/28906-1\">28906-1<\/a><\/td><td><a href=\"p\/28906-3\">28906-3<\/a><\/td><\/tr><tr><td>Volatile<\/td><td>60\u2013275<\/td><td>Polydimethylsiloxane (PDMS)<\/td><td>100<\/td><td>1.5<\/td><td>Red<\/td><td><a href=\"p\/28910-1\">28910-1<\/a><\/td><td><a href=\"p\/28910-3\">28910-3<\/a><\/td><\/tr><tr><td>Volatile (high capacity)<\/td><td>60\u2013275<\/td><td>Polydimethylsiloxane (PDMS)<\/td><td>250<\/td><td>1.5<\/td><td>Black<\/td><td><a href=\"p\/28911-1\">28911-1<\/a><\/td><td><a href=\"p\/28911-3\">28911-3<\/a><\/td><\/tr><tr><td>Polar, semivolatile<\/td><td>80\u2013300<\/td><td>Polyacrylate (PA)<\/td><td>100<\/td><td>1.1<\/td><td>Gray<\/td><td><a href=\"p\/28902-1\">28902-1<\/a><\/td><td><a href=\"p\/28902-3\">28902-3<\/a><\/td><\/tr><tr><td>Highly volatile<\/td><td>30\u2013225<\/td><td>Carbon Wide Range\/<br>Polydimethylsiloxane (Carbon-WR\/PDMS)&nbsp;<\/td><td>120<\/td><td>1.1<\/td><td>Light Blue<\/td><td><a href=\"p\/28903-1\">28903-1<\/a><\/td><td><a href=\"p\/28903-3\">28903-3<\/a><\/td><\/tr><tr><td>Highly volatile<\/td><td>30\u2013225<\/td><td>Carbon Wide Range\/<br>Polydimethylsiloxane (Carbon-WR\/PDMS)&nbsp;<\/td><td>120<\/td><td>1.5<\/td><td>Light Blue<\/td><td><a href=\"p\/28907-1\">28907-1<\/a><\/td><td><a href=\"p\/28907-3\">28907-3<\/a><\/td><\/tr><tr><td>Aromatic, semivolatile<\/td><td>60\u2013300<\/td><td>Divinylbenzene\/<br>Polydimethylsiloxane (DVB\/PDMS)<\/td><td>120<\/td><td>1.1<\/td><td>Violet<\/td><td><a href=\"p\/28905-1\">28905-1<\/a><\/td><td><a href=\"p\/28905-3\">28905-3<\/a><\/td><\/tr><tr><td>Aromatic, semivolatile<\/td><td>60\u2013300<\/td><td>Divinylbenzene\/<br>Polydimethylsiloxane (DVB\/PDMS)<\/td><td>120<\/td><td>1.5<\/td><td>Violet<\/td><td><a href=\"p\/28909-1\">28909-1<\/a><\/td><td><a href=\"p\/28909-3\">28909-3<\/a><\/td><\/tr><tr><td>Volatile and semivolatile<\/td><td>40\u2013275<\/td><td>Divinylbenzene\/<br>Carbon Wide Range\/<br>Polydimethylsiloxane (DVB\/Carbon-WR\/PDMS)<\/td><td>120<\/td><td>1.1<\/td><td>Dark Gray<\/td><td><a href=\"p\/28904-1\">28904-1<\/a><\/td><td><a href=\"p\/28904-3\">28904-3<\/a><\/td><\/tr><tr><td>Volatile and semivolatile<\/td><td>40\u2013275<\/td><td>Divinylbenzene\/<br>Carbon Wide Range\/<br>Polydimethylsiloxane (DVB\/Carbon-WR\/PDMS)<\/td><td>120<\/td><td>1.5<\/td><td>Dark Gray<\/td><td><a href=\"p\/28908-1\">28908-1<\/a><\/td><td><a href=\"p\/28908-3\">28908-3<\/a><\/td><\/tr><tr><td colspan=\"6\">PAL Smart SPME Arrow Method Development Kit (one Smart SPME arrow each: 1.1 mm PA 100 \u03bcm, 1.1 mm Carbon-WR\/PDMS 120 \u03bcm; 1.1 mm DVB\/PDMS 120 \u03bcm; 1.1 mm PDMS 100 \u03bcm; 1.1 mm DVB\/Carbon-WR\/PDMS 120 \u03bcm).<\/td><td><a href=\"p\/28901\">28901 (kit)<\/a><\/td><td>____<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><sup>*<\/sup>Recommended maximum GC inlet pressure is 50 psi or less.<br>All Restek PAL SPME Arrows have 20 mm of stationary phase bonded onto stainless steel.<br><sup>\u2020<\/sup>These molecular weight ranges are a reasonable approximation; however, end users should verify suitability for their specific application.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">On Target: Higher Sample Throughput<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek PAL Smart SPME Arrows provide much faster extraction times than traditional SPME fibers because Arrows have much more phase volume. As shown in Figure 3, the increased phase volume allows more target analyte to be extracted in just seconds using an Arrow than can be extracted from a traditional fiber. Being able to extract what you need in a fraction of the time means more samples can be analyzed per day, which improves lab efficiency and profitability. The example in Table II demonstrates a nearly 50% increase in productivity!<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Benchmark Comparison of 1.1 mm SPME Arrow vs. Standard SPME Fiber for 2.5 ppb Volatiles in Headspace<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43820_c1b00a-ea .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43820_c1b00a-ea\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"869\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03-1024x869.jpg\" alt=\"\" class=\"kb-img wp-image-23182\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03-1024x869.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03-300x255.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03-768x652.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03-1536x1304.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong>&nbsp;Analyze more samples per day with Restek PAL SPME Arrow.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"9\"><strong>Sample Collection and Desorption Steps with Associated Times (sec)<\/strong><\/td><\/tr><tr><td><strong>Select Sample Vial<\/strong><\/td><td><strong>Vial Incubation \/ Fiber Conditioning<\/strong><\/td><td><strong>Vial Transfer<\/strong><\/td><td><strong>Sample Extraction (Headspace)<\/strong><\/td><td><strong>GC Equilibration<\/strong><\/td><td><strong>Desorb Fiber<\/strong><\/td><td><strong>Return Sample Vial<\/strong><\/td><td><strong>Total Time<\/strong><\/td><td><strong>Samples per Day<\/strong><\/td><\/tr><tr><td colspan=\"9\"><strong>Target Analytes: Traditional SPME Fiber<\/strong><\/td><\/tr><tr><td>22<\/td><td>120<\/td><td>20<\/td><td><strong>120<\/strong><\/td><td>15<\/td><td>10<\/td><td>15<\/td><td>322<\/td><td><strong>268<\/strong><\/td><\/tr><tr><td colspan=\"9\"><strong>Target Analytes: SPME Arrow<\/strong><\/td><\/tr><tr><td>22<\/td><td>120<\/td><td>20<\/td><td><strong>15<\/strong><\/td><td>15<\/td><td>10<\/td><td>15<\/td><td>217<\/td><td><strong>398 (~50% increase)<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;Note: Processes that take &lt;10 sec to perform were omitted from the table. Actual samples per day is dependent on GC cycle time.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">On Target: Lower Detection Limits<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Developing a new method or trying to improve the performance of an existing one? Restek PAL Smart SPME Arrows have more phase volume, so they provide much greater sensitivity than traditional fibers. To demonstrate this, 82 volatile compounds were analyzed under three different headspace extraction time and extraction volume combinations. Results under all experimental conditions definitively show that Arrow outperforms traditional SPME fiber and provides much higher analyte responses (Table III and Figure 4).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong>&nbsp;Analyte response is much higher with SPME Arrow than with a traditional SPME fiber.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td colspan=\"2\">&nbsp;<\/td><td colspan=\"2\"><strong>Average % Increase in Response of Arrow vs.<br>Traditional Fiber<\/strong><\/td><\/tr><tr><td><strong>Extraction Time (min)<\/strong><\/td><td><strong>Extraction Volume (mL Water)<\/strong><\/td><td><strong>1.1 mm Arrow<\/strong><\/td><td><strong>1.5 mm Arrow<\/strong><\/td><\/tr><tr><td>10<\/td><td>10<\/td><td>297%<\/td><td>527%<\/td><\/tr><tr><td>5<\/td><td>10<\/td><td>618%<\/td><td>896%<\/td><\/tr><tr><td>10<\/td><td>5<\/td><td>446%<\/td><td>634%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong>\u00a0Restek PAL SPME Arrow extracts more target analyte from samples, allowing lower detection limits.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1439.png\" alt=\"SPME Arrow vs. Traditional SPME Fiber\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1439<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rtx-VMS, 30 m, 0.25 mm ID, 1.40 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/19915\" rel=\"noopener\">cat.# 19915<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>2-Chloroethyl vinyl ether (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30265\" rel=\"noopener\">cat.# 30265<\/a>)<\/td><\/tr><tr><td><\/td><td>8260 MegaMix calibration mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30633\" rel=\"noopener\">cat.# 30633<\/a>)<\/td><\/tr><tr><td><\/td><td>8260 Surrogate mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30073\" rel=\"noopener\">cat.# 30073<\/a>)<\/td><\/tr><tr><td><\/td><td>VOA calibration mix #1 (ketones) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30006\" rel=\"noopener\">cat.# 30006<\/a>)<\/td><\/tr><tr><td><\/td><td>California oxygenates mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30465\" rel=\"noopener\">cat.# 30465<\/a>)<\/td><\/tr><tr><td><\/td><td>502.2 Calibration mix #1 (gases) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30042\" rel=\"noopener\">cat.# 30042<\/a>)<\/td><\/tr><tr><td><\/td><td>8260 Internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30074\" rel=\"noopener\">cat.# 30074<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>50 ng\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 1.8 mm ID straight\/SPME inlet liner (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23280\" rel=\"noopener\">cat.# 23280<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 100 &#176;C at 12 &#176;C\/min (hold 0 min) to 240 &#176;C at 25 &#176;C\/min (hold 1.6 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.0 mL\/min<tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>44.411 cm\/sec @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>0<\/td><td>35-226<\/td><td>12.1<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Type:<\/th><td>Extractor <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Extractor Lens:<\/th><td>3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>300 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70.0 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>manual <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC &amp; 5977A MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Acknowledgement<\/th><td>CTC Analytics AG<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30265<\/li><li>30633<\/li><li>30073<\/li><li>30006<\/li><li>30465<\/li><li>30042<\/li><li>30074<\/li><li>19915<\/li><li>23280<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1439.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Turning to the emerging cannabis market and the triple-phase (DVB\/Carbon WR\/PDMS) Arrow, you can also expect significantly higher analyte responses with residual solvents and other classes of compounds (Figure 5).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong>\u00a0Restek PAL SPME Arrow provides similarly superior results for residual solvents and other compounds.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1204.png\" alt=\"Triple-Phase SPME Arrow vs. Triple-Phase SPME Fiber\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1204<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Propane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/74-98-6\/n-Propane\" target=\"_blank\" rel=\"noopener\">n-Propane<\/a><\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isobutane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-28-5\/Isobutane\" target=\"_blank\" rel=\"noopener\">Isobutane<\/a><\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Butane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-97-8\/n-Butane\" target=\"_blank\" rel=\"noopener\">n-Butane<\/a><\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-56-1\/Methanol\" target=\"_blank\" rel=\"noopener\">Methanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Pentane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-66-0\/n-Pentane\" target=\"_blank\" rel=\"noopener\">n-Pentane<\/a><\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/64-17-5\/Ethanol\" target=\"_blank\" rel=\"noopener\">Ethanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-29-7\/Diethyl ether\" target=\"_blank\" rel=\"noopener\">Diethyl ether<\/a><\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-64-1\/Acetone\" target=\"_blank\" rel=\"noopener\">Acetone<\/a><\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Propanol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-63-0\/2-Propanol\" target=\"_blank\" rel=\"noopener\">2-Propanol<\/a><\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetonitrile\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-05-8\/Acetonitrile\" target=\"_blank\" rel=\"noopener\">Acetonitrile<\/a><\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methylene chloride\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/75-09-2\/Methylene chloride\" target=\"_blank\" rel=\"noopener\">Methylene chloride<\/a><\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Hexane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-54-3\/n-Hexane\" target=\"_blank\" rel=\"noopener\">n-Hexane<\/a><\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl acetate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-78-6\/Ethyl acetate\" target=\"_blank\" rel=\"noopener\">Ethyl acetate<\/a><\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chloroform\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-66-3\/Chloroform\" target=\"_blank\" rel=\"noopener\">Chloroform<\/a><\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclohexane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-82-7\/Cyclohexane\" target=\"_blank\" rel=\"noopener\">Cyclohexane<\/a><\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/71-43-2\/Benzene\" target=\"_blank\" rel=\"noopener\">Benzene<\/a><\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107-06-2\/1,2-Dichlorethane\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorethane<\/a><\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for n-Heptane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/142-82-5\/n-Heptane\" target=\"_blank\" rel=\"noopener\">n-Heptane<\/a><\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trichloroethene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79-01-6\/Trichloroethene\" target=\"_blank\" rel=\"noopener\">Trichloroethene<\/a><\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Toluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-88-3\/Toluene\" target=\"_blank\" rel=\"noopener\">Toluene<\/a><\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for m-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-38-3\/m-Xylene\" target=\"_blank\" rel=\"noopener\">m-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-42-3\/p-Xylene\" target=\"_blank\" rel=\"noopener\">p-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Xylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-47-6\/o-Xylene\" target=\"_blank\" rel=\"noopener\">o-Xylene<\/a><\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N,N-Dimethylacetamide (solvent)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/127-19-5\/N,N-Dimethylacetamide\" target=\"_blank\" rel=\"noopener\">N,N-Dimethylacetamide (solvent)<\/a><\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-624Sil MS, 30 m, 0.25 mm ID, 1.40 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13868\" rel=\"noopener\">cat.# 13868<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Residual solvents #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34105\" rel=\"noopener\">cat.# 34105<\/a>)<\/td><\/tr><tr><td><\/td><td>n-Propane, isobutane, <i>n<\/i>-butane (Emerald Scientific)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>N,N-Dimethylacetamide<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td>Direct<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 1.8 mm ID straight\/SPME inlet liner (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23280\" rel=\"noopener\">cat.# 23280<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>30 &#176;C (hold 6 min) to 85 &#176;C at 15 &#176;C\/min (hold 2 min) to 250 &#176;C at 35 &#176;C\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>FID @ 320 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Flow Rate:<\/th><td>40 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Make-up Gas Type:<\/th><td>N<sub>2<\/sub> <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Hydrogen flow:<\/th><td>45 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Air flow:<\/th><td>450 mL\/min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Data Rate:<\/th><td>20 Hz<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890B GC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>A 6 mL sample for residual solvents analysis based on USP  was prepared for headspace solid phase microextraction (HS-SPME) as follows:<br \/>1. 3 g sodium chloride was weighed into a 20 mL amber headspace vial (cat. # 23086) with screw top cap (cat. # 23090). <br \/>2. 6 mL of deionized water was added to the vial. <br \/>3. The sample was fortified at 10 \u00b5g\/mL with the residual solvents, <i>n<\/i>-propane, isobutane, and <i>n<\/i>-butane standards. <br \/>4. The vial was capped and vortexed at 3000 rpm for 10 seconds, inverted, then vortexed again for 10 seconds at 3000 rpm. <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><b>CTC RTC Parameters<br \/>HS-SPME Arrow<\/b><br \/>Tool: SPME Arrow and SPME fiber<br \/>SPME Arrow: Restek PAL SPME Arrow, DVB\/C-WR\/PDMS, 1.1 mm, 120 \u03bcm cat.# 27875 <br \/>SPME Fiber: Restek SPME fiber, DVB\/C-WR\/PDMS cat.# 27873-1<br \/>Agitator Speed: 250 rpm<br \/>Agitator Temp: 30 \u00b0C<br \/>Incubation Time: 120 sec<br \/>Heatex Stirrer Speed: 1000 rpm<br \/>Heatex Stirrer Temp.: 30 \u00b0C<br \/>Vial Penetration Depth: 35 mm<br \/>Extraction Time: 120 sec<br \/>Injector Penetration Depth: 50 mm<br \/>Desorption Time: 10 sec<br \/>Pre-Conditioning: True<br \/>Post-Conditioning: False<br \/>Conditioning Time: 60 sec<br \/>Conditioning Temp.: 250 \u00b0C<br \/><br \/>SPME Arrow cat.# 27875 and SPME fiber cat.# 27873-1 were used to produce this chromatogram but have since been discontinued. For assistance choosing replacements for this application, contact Restek Technical Service or your local Restek representative.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34105<\/li><li>13868<\/li><li>23280<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Residual<\/li><li>Solvents<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1204.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong>\u00a0Traditional SPME fibers cannot match the extraction yield of SPME Arrows (immersion extraction technique).<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43820_c401ca-30 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43820_c401ca-30\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"540\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06-1024x540.jpg\" alt=\"\" class=\"kb-img wp-image-23200\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06-1024x540.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06-300x158.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06-768x405.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06-1536x811.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2642D-06.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:19px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"What is SPME?\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/YC201BnFGZc?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"SPME Arrow Tips\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/wASzuLOd9H8?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The PAL SPME Arrow system is a revolutionary change in microextraction that combines exceptional robustness with faster extraction times and trace-level sensitivity. In contrast to traditional SPME fibers, SPME Arrows contain significantly more sorbent which allows more target analyte to be extracted in less time, significantly increasing sample throughput. In addition, the unique Arrow tip, inner stabilizing rod, and outer sheath design fully protect the sorbent, minimizing both and analyte loss and mechanical damage.<\/p>\n","protected":false},"author":11,"featured_media":7393,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2519,2547],"resource-technique":[2338],"ppma_author":[414],"class_list":["post-43820","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","product-library-prodotti-per-la-preparazione-del-campione","product-library-spme-prodotti","resource-technique-microestrazione-in-fase-solida-spme"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"product-library":[{"value":2519,"label":"Prodotti per la Preparazione del Campione"},{"value":2547,"label":"SPME"}],"resource-technique":[{"value":2338,"label":"Microestrazione in Fase Solida (SPME)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS2642-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":788,"category_count":511,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43820","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43820"}],"version-history":[{"count":13,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43820\/revisions"}],"predecessor-version":[{"id":103114,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43820\/revisions\/103114"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/7393"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43820"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43820"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43820"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43820"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43820"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43820"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43820"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43820"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43820"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}