{"id":43885,"date":"2020-10-22T00:00:00","date_gmt":"2020-10-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/packed-column-information\/"},"modified":"2026-01-28T15:57:41","modified_gmt":"2026-01-28T15:57:41","slug":"packed-column-information","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/articles\/pcot3225\/packed-column-information","title":{"rendered":"Packed &#038; Micropacked Column Information"},"content":{"rendered":"<p><strong><a id=table-01\"><\/a>Table I:<\/strong>&nbsp;For specific applications, we recommend using these optimized columns for better method performance. Click on the column name for product specifications and easy online ordering.<\/p>\n<div>\n<table class=\"table table-bordered\" style=\"width: 100%; border-collapse: collapse; height: 891px;\">\n<tbody>\n<tr class=\"thead\" style=\"height: 19.25px;\">\n<td style=\"width: 25%; height: 19.25px; background-color: rgb(220, 221, 221); border-color: rgb(220, 221, 221);\"><strong>Application<\/strong><\/td>\n<td style=\"width: 25%; text-align: center; height: 19.25px; background-color: rgb(220, 221, 221); border-color: rgb(220, 221, 221);\"><strong>Column<\/strong><\/td>\n<td style=\"width: 25%; text-align: center; height: 19.25px; background-color: rgb(220, 221, 221); border-color: rgb(220, 221, 221);\"><strong>Feature<\/strong><\/td>\n<td style=\"width: 25%; text-align: center; height: 19.25px; background-color: rgb(220, 221, 221); border-color: rgb(220, 221, 221);\"><strong>Benefit<\/strong><\/td>\n<\/tr>\n<tr style=\"height: 214.5px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 214.5px;\">\n<p>ASTM Method D3606<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 214.5px;\">\n<p><a href=\"https:\/\/www.restek.com\/p\/83606-800\" target=\"_blank\" rel=\"noopener\">D3606 Application Column Set<\/a><\/p>\n<p>Column 1: Backflush column, 6&#8242; (1.8 m), 1\/8&#8243; OD, 2.0 mm ID; Column 2: proprietary packing, 16&#8242; (4.9 m), 1\/8&#8243; OD, 2.0 mm ID<\/p>\n<p><a href=\"https:\/\/www.restek.com\/p\/118-D3606\" target=\"_blank\" rel=\"noopener\">D3606 GC Capillary Column Set<\/a><br \/>Column 1: Rxi-1ms Capillary Column, 30 m, 0.25 mm ID, 0.50 &micro;m; Column 2: Stabilwax GC Capillary Column, 60 m, 0.32 mm ID, 1.00 &micro;m<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 214.5px;\">\n<p>Excellent separation of ethanol and benzene for ethanol blended fuels.<\/p>\n<p>&nbsp;<\/p>\n<p>Accurate quantitation of toluene and benzene, including benzene in gasoline containing ethanol or butanol blends.<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 214.5px;\">\n<p>Reliably meets method requirements.<\/p>\n<p><\/p>\n<p>Reliably meets method requirements.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 143px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 143px;\">\n<p>Refinery Gases<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 143px;\">\n<p><a href=\"https:\/\/www.restek.com\/p\/88000-810\" target=\"_blank\" rel=\"noopener\">2abc Refinery Gas Column Set<\/a><\/p>\n<p><a href=\"https:\/\/www.restek.com\/p\/88004-875\" target=\"_blank\" rel=\"noopener\">Backflush Column<\/a><\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 143px;\">\n<p>Optimized three-column set. (Backflush column sold separately.)<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 143px;\">\n<p>Elutes C5 hydrocarbons before C1-C4 hydrocarbons for optimized resolution.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 123.75px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 123.75px;\">\n<p>Unsaturated Light Hydrocarbons<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 123.75px;\">\n<p><a href=\"https:\/\/www.restek.com\/p\/80436-800\" target=\"_blank\" rel=\"noopener\">n-Octane on Res-Sil C Column<\/a><\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 123.75px;\">\n<p>Unique selectivity for unsaturated hydrocarbons.<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 123.75px;\">\n<p>Excellent resolution of unsaturated light hydrocarbons gives increased data accuracy.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 123.75px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>cis-2-Butene and 1,3-Butadiene<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p><a href=\"https:\/\/www.restek.com\/p\/80437-800\" target=\"_blank\" rel=\"noopener\">OPN on Res-Sil C Column<\/a><\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Optimized selectivity for&nbsp;cis-2-butene and 1,3-butadiene resolution.<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Increased data accuracy.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 143px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 143px;\">\n<p>Permanent Gases<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 143px;\">\n<p>ShinCarbon ST Columns<br \/><a href=\"https:\/\/www.restek.com\/p\/80486-800\" target=\"_blank\" rel=\"noopener\">Packed<\/a>&nbsp;\/ <a href=\"https:\/\/www.restek.com\/p\/19043\" target=\"_blank\" rel=\"noopener\">Micropacked<\/a><\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 143px;\">\n<p>Optimized selectivity for permanent gas resolution without cryogenic cooling. Preconditioned.<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; height: 143px;\">\n<p>Increases productivity.<\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 123.75px;\">\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Low-Level Sulfurs<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Rt-XLSulfur Columns<br \/><a href=\"https:\/\/www.restek.com\/p\/80484-800\" target=\"_blank\" rel=\"noopener\">Packed&nbsp;<\/a>\/ <a href=\"https:\/\/www.restek.com\/p\/19044\" target=\"_blank\" rel=\"noopener\">Micropacked<\/a><\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Highly inert for ppbv levels of sulfur. Eliminates need for PTFE tubing.<\/p>\n<\/td>\n<td style=\"width: 25%; text-align: left; vertical-align: top; border-color: rgb(220, 221, 221); background-color: rgb(220, 221, 221); height: 123.75px;\">\n<p>Increased data accuracy for low-level sulfur analysis. Eliminates need for a special GC setup.<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><strong><a id=\"table-02\"><\/a>Table II:<\/strong>&nbsp;Select the packed column configuration that fits your instrument from the options below and add the corresponding suffix to any standard part number.<\/p>\n<p><em>(Note that small OD columns [1\/16&rdquo; or less] do not require a suffix.)<\/em><\/p>\n<div>\n<table class=\"table table-bordered\" style=\"width: 100%; border-collapse: collapse;\">\n<tbody>\n<tr class=\"thead\">\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\"><strong>Suffix<\/strong><\/td>\n<td style=\"width: 50%; text-align: center; border-color: #dcdddd; background-color: #dcdddd;\"><strong>Configuration<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-800<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>General<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-810<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p class=\"p1\">Agilent Standard<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-811<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Agilent 6850<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-820<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Varian Standard<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-821<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Varian 3800<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-830<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>PE 900-3920; Sigma 1,2,3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-840<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p class=\"p1\">PE Standard<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-845<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>ABB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-850<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Shimadzu 14A, 2014<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-851<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Shimadzu 8A<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-853<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Shimadzu 17A, 2010<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-860<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Thermo TRACE 2000<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-875<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Analytical Controls<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-890<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Gow Mac 590<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-891<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>Gow Mac 550<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>-893<\/p>\n<\/td>\n<td style=\"width: 50%; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Gow Mac 816<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%;\">\n<p>-895<\/p>\n<\/td>\n<td style=\"width: 50%;\">\n<p>SRI 8610C<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>&nbsp;<\/p>\n<p><a id=\"table-03\"><\/a>Complete your column with one of our fitting kits.<\/p>\n<div>\n<table class=\"table table-bordered\" style=\"width: 100%; border-collapse: collapse; height: 198px;\">\n<tbody>\n<tr class=\"thead\" style=\"height: 18px;\">\n<td style=\"width: 50%; height: 18px; border-color: #dcdddd; background-color: #dcdddd;\"><strong>Option*<\/strong><\/td>\n<td style=\"width: 50%; text-align: center; height: 18px; border-color: #dcdddd; background-color: #dcdddd;\"><strong>Description<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit 1S<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/4&#8243; Brass Nuts, <br \/>1\/4&#8243; to 1\/8&#8243; V\/G Reducing Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit 2S<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/4&#8243; Brass Nuts, <br \/>1\/4&#8243; to 3\/16&#8243; V\/G Reducing Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit A<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/8&#8243; Brass Nuts, <br \/>1\/8&#8243; V\/G Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit B<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/8&#8243; Brass Nuts, <br \/>1\/8&#8243; Brass Front &amp; Back Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit B2<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/4&#8243; Brass Nuts,<br \/>1\/4&#8243; Brass Front &amp; Back Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit C<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/8&#8243; SS Nuts, <br \/>1\/8&#8243; SS Front &amp; Back Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit D<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/8&#8243; SS Nuts, <br \/>1\/8&#8243; V\/G Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit E<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/4&#8243; SS Nuts, <br \/>1\/4&#8243; to 1\/8&#8243; V\/G Reducing Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit F<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/4&#8243; SS Nuts, <br \/>1\/4&#8243; to 3\/16&#8243; V\/G Reducing Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit G<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/4&#8243; SS Nuts,<br \/>1\/4&#8243; V\/G Ferrules<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Kit VNICKEL<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Fitting Kit: 1\/8&#8243; VCR fittings (Nickel)<br \/>(Silver soldered onto the column)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Kit VSS<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top; border-color: #dcdddd; background-color: #dcdddd;\">\n<p>Fitting Kit: 1\/8&#8243; VCR fitting (SS)<br \/>(Silver soldered onto the column)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Preconditioning<\/p>\n<\/td>\n<td style=\"width: 50%; vertical-align: top;\">\n<p>Optional for each finished column<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>*Some options available at additional cost.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>For specific applications, we recommend using these optimized packed &#038; micropacked columns for better method performance. Click on the column name for product specifications and easy online ordering.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[2204],"post-badge":[],"resource-type":[567],"product-library":[2444,2456],"resource-technique":[2316],"ppma_author":[414],"class_list":["post-43885","post","type-post","status-publish","format-standard","hentry","category-articles","industries-application-energie","resource-type-selection-guides","product-library-produits-pour-la-chromatographie-en-phase-gazeuse","product-library-colonnes-gc","resource-technique-chromatographie-en-phase-gazeuse-gc"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2204,"label":"Energie"}],"resource-type":[{"value":567,"label":"Selection Guides"}],"product-library":[{"value":2444,"label":"Produits pour la chromatographie en phase gazeuse"},{"value":2456,"label":"Colonnes GC"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":7,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=43885"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43885\/revisions"}],"predecessor-version":[{"id":85411,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/43885\/revisions\/85411"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=43885"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=43885"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=43885"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=43885"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=43885"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=43885"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=43885"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=43885"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=43885"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}