   {"id":45294,"date":"2020-10-26T14:30:00","date_gmt":"2020-10-26T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analyse-von-pestizidruckstanden-in-pflanzlichen-inhaltsstoffen-mittels-triple-quadrupol-gc-ms-ms\/"},"modified":"2026-01-28T22:19:25","modified_gmt":"2026-01-28T22:19:25","slug":"analyse-von-pestizidruckstanden-in-pflanzlichen-inhaltsstoffen-mittels-triple-quadrupol-gc-ms-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/fsar3080-de\/analyse-von-pestizidruckstanden-in-pflanzlichen-inhaltsstoffen-mittels-triple-quadrupol-gc-ms-ms","title":{"rendered":"Analyse von Pestizidr\u00fcckst\u00e4nden in pflanzlichen Inhaltsstoffen mittels Triple-Quadrupol GC-MS\/MS"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Einf\u00fchrung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In den USA werden Nahrungserg\u00e4nzungsmittel in zunehmendem Ma\u00dfe verwendet. Diese Produkte werden aus diversen getrockneten Pflanzen hergestellt, die aufgrund landwirtschaftlicher Praktiken Pestizidr\u00fcckst\u00e4nde enthalten k\u00f6nnen. Zur Sicherung ihrer Qualit\u00e4t und um eine Exposition zu vermeiden, ist ihre \u00dcberwachung deshalb unerl\u00e4sslich. Die Inhaltsstoffe liegen in getrocknetem Zustand vor, so dass die Standard-QuEChERS-Methoden [1] modifiziert werden m\u00fcssen. Die beste Methode zur Trennung von Mehrstoffgemischen mit koextrahierten St\u00f6rsubstanzen ist die Gaschromatografie. In Verbindung mit einem hochempfindlichen Triple-Quadrupol-Massenspektrometer (GC-MS\/MS) lassen sich so Verunreinigungen im Spurenbereich nachweisen. In dieser Studie haben wir auf einem Triple-Quadrupol GC-MS\/MS-System mit der modifizierten QuEChERS-Methode mehr als 200 Verbindungen gleichzeitig analysiert.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Materialien und Methoden<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Pestizidstandards, interne Standards, Qualit\u00e4tskontrollstandards und ein QuEChERS-Kit wurden von Restek erhalten:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GC Multipestizid-Kit (Art.-Nr. 32562)<\/li>\n\n\n\n<li>QuEChERS Internal Standard Mix f\u00fcr die GC-MS Analyse (Art.-Nr. 33267)<\/li>\n\n\n\n<li>SV Internal Standard Mix (Art.-Nr.31206)<\/li>\n\n\n\n<li>Q-sep QuEChERS Extraktions-Kit (Urspr\u00fcngliche Art.-Nr. 23991 wurde abgek\u00fcndigt; siehe\u00a0Art.-Nr.\u00a025848)<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Insgesamt wurden 232 Verbindungen (220 Pestizide, 6 interne Standards und 6 Qualit\u00e4ts-kontrollstandards) analysiert. Kommerziell erh\u00e4ltliches Ginseng wurde als Matrix verwendet. Damit wurden matrixangepasste Kalibrierstandards (1 bis 200 ng\/mL) und angereicherte Proben (jeweils zwei mit 10 ng\/g und 50 ng\/g) hergestellt. Kalibrierkurven (gewichtet 1\/C) wurden mithilfe des internen Standards PCB52 generiert.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eine MRM-Analysemethode wurde unter Verwendung der Smart Pesticides Database (Shimadzu) erstellt. Diese Datenbank enth\u00e4lt Retentionsindizes f\u00fcr alle registrierten Verbindungen und die Retentionszeiten lassen sich durch Analyse eines n-Alkan-Probengemischs vorhersagen (AART: Automatic Adjustment of Retention Time). Auf der Basis der erwarteten Retentionszeiten erzeugt Smart MRM ein optimales Zeitprogramm zur Datenerfassung (Abbildung 1).&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 1:\u00a0<\/strong>\u00a0Von Smart MRM erstelltes Zeitprogramm zur Datenerfassung<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"960\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-FSAR3080-01-1024x960.jpg\" alt=\"\" class=\"wp-image-20041\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-01-1024x960.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-01-300x281.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-01-768x720.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-01-1536x1440.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Extraktion und Reinigungsverfahren<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>1.0 \u00b1 0.05 g gemahlenes Ginsengpulver in 50-mL-Polypropylen-Zentrifugenr\u00f6hrchen einwiegen.<\/li>\n\n\n\n<li>10 mL Wasser von HPLC-Qualit\u00e4t zugeben und das R\u00f6hrchen auf einem Vortex-Mischer kr\u00e4ftig sch\u00fctteln.<\/li>\n\n\n\n<li>10 mL des ACN\/IS-Extraktionsl\u00f6semittels zugeben.<\/li>\n\n\n\n<li>R\u00f6hrchen 15 Minuten stehen lassen.<\/li>\n\n\n\n<li>4 g wasserfreies MgSO4 und 1 g NaCl zugeben.<\/li>\n\n\n\n<li>R\u00f6hrchen auf einem mechanischen Sch\u00fcttelapparat bei hoher Sch\u00fcttelintensit\u00e4t 30 Minuten lang sch\u00fctteln.<\/li>\n\n\n\n<li>Die 50-mL-R\u00f6hrchen bei 3000\u20134500 U\/min 5 Minuten zentrifugieren.<\/li>\n\n\n\n<li>Die GCB\/PSA (0.25 g\/0.5 g) SPE-S\u00e4ulen mit ca. 250 mg oben aufgebrachtem wasserfreiem Na2SO4 und dem 3-fachen S\u00e4ulenvolumen Aceton konditionieren.<\/li>\n\n\n\n<li>Sammelgestell mit 15-mL-Einweg-Glaszentrifugenr\u00f6hrchen auf einem SPE-Vakuumverteiler einsetzen.<\/li>\n\n\n\n<li>1.25 mL des ACN-Extrakts zugeben.<\/li>\n\n\n\n<li>Mit 1 mL Aceton sp\u00fclen.<\/li>\n\n\n\n<li>Mit 12 mL eines Aceton-Toluol-Gemischs (3:1 Vol.\/Vol.) eluieren.<\/li>\n\n\n\n<li>Das Elutionsmittel vorsichtig (50 \u00b0C) bis auf ca. 100 \u03bcL verdampfen.<\/li>\n\n\n\n<li>500 \u03bcL Toluol zu den Leer-\/angereicherten Proben, den Kalibrierstandardl\u00f6sungen und den matrixangepassten Kalibrierstandards hinzuf\u00fcgen.<\/li>\n\n\n\n<li>20 \u03bcL Qualit\u00e4tskontrollstandards (12.5 \u03bcg\/mL) und ca. 50 mg wasserfreies MgSO4 zu allen Proben hinzuf\u00fcgen.<\/li>\n\n\n\n<li>5 Sekunden lang auf dem Vortex-Mischer sch\u00fctteln.<\/li>\n\n\n\n<li>R\u00f6hrchen 5 Minuten bei 3000 g zentrifugieren.<\/li>\n\n\n\n<li>Toluolextrakt mithilfe einer Pasteur-Pipette an die ALS GC-Fl\u00e4schchen \u00fcberf\u00fchren.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Ergebnis und Diskussion<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Matrixangepasste Kalibrierung<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Das Chromatogramm in Abbildung 2 zeigt einen matrixangepassten 10-ng\/mL-Kalibrierstandard. Von den 232 Verbindungen konnten 230 innerhalb von \u00b10.1 Minuten der erwarteten Retentionszeit durch AART nachgewiesen werden. Die zwei verbleibenden Verbindungen, 1,4-Dichlorbenzol-d4 und Naphthalin-d8 aus den sechs Qualit\u00e4tskontrollstandards, eluierten in weniger als 4 Minuten. Obwohl die Retentionszeiten verschoben waren, fielen sie innerhalb von \u00b10.2 Minuten der erwarteten Retentionszeiten.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 2<\/strong>: MRM-Chromatogramm des matrixangepassten 10-ng\/mL-Kalibrierstandards (Interne Standards und Qualit\u00e4tskontrollstandards sind nicht gezeigt.)<br><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0568.png\" alt=\"Residual Pesticides in Botanicals by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0568<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Rxi-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/13423\" rel=\"noopener\">cat.# 13423<\/a>)<\/td><\/tr><tr><td><\/td><td>using Rxi guard column 5 m, 0.25 mm ID (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/10029\" rel=\"noopener\">cat.# 10029<\/a>)<\/td><\/tr><tr><td><\/td><td>with SilTite \u03bc-Union connector kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23885\" rel=\"noopener\">cat.# 23885<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>GC Multiresidue pesticide kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/32562\" rel=\"noopener\">cat.# 32562<\/a>)<\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Toluene<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>2 \u00b5L pulsed splitless<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 3.5 mm ID single taper inlet liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23336\" rel=\"noopener\">cat.# 23336<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pulse Pressure:<\/th><td>36 psi (248.2kPa)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pulse Time:<\/th><td>1.5  min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>90 &#176;C (hold 1 min) to 130 &#176;C at 30 &#176;C\/min to 330 &#176;C at 10 &#176;C\/min (hold 2 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant linear velocity<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>55 cm\/sec<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu GCMS TQ8040<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>290 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu GCMS-TQ8040<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Matrix-matched calibration standards were prepared in ginseng. Calibration curves were generated by the internal standard method using PCB52 as the internal standard. An MRM analytical method was created using the Shimadzu pesticides database. <br \/><br \/>Although the multiresidue pesticides kit mixes are formulated to ensure maximum long-term stability and reliability as packaged, stability may become an issue when a large number of compounds with different chemical functionalities are combined together into a single mix. This should be taken into consideration for quantitative analysis.<br \/><br \/><br \/><\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Acknowledgement<\/th><td>Chromatogram provided by Shimadzu. Publication 3655-11615-10ANS (C146-E334), First Edition, December 2016. Residual Pesticides Analysis of Botanical Ingredients Using Gas Chromatography Triple Quadrupole Mass Spectrometry. Riki Kitano, Tairo Ogura, Nicole Lock, Robert Clifford, Julie Kowalski, Jack Cochran, Dan Li<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32562<\/li><li>13423<\/li><li>10029<\/li><li>23885<\/li><li>23336<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>QuEChERS<\/li><li>Rxi<\/li><li>botanical<\/li><li>pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0568.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Die Kalibrierkurven wurden mithilfe von matrixangepassten Kalibrierstandards erstellt und die R\u00fcckrechnung und Linearit\u00e4t wurden anschlie\u00dfend ausgewertet.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die R\u00fcckrechnung wurde durchgef\u00fchrt, indem die Konzentration jedes Kalibrierpunkts berechnet wurde. Wenn die Konzentration den theoretischen Wert um \u00b120 % \u00fcbertraf, wurde der Kalibrierpunkt unter Einbeziehung der beiden n\u00e4chstliegenden Punkte interpoliert. Mehr als 93 % der Verbindungen mit einer Konzentration von 1 ng\/mL lagen innerhalb von \u00b120 % der theoretischen Berechnungen und alle Verbindungen mit Konzentrationen von 20 bis 200 ng\/mL lagen innerhalb von \u00b120 % (Abbildung 3).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 3:<\/strong>\u00a0Unterschied zwischen R\u00fcckrechnung und theoretischer Konzentration<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"548\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-FSAR3080-03-1024x548.jpg\" alt=\"\" class=\"wp-image-20047\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-03-1024x548.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-03-300x161.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-03-768x411.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-03-1536x823.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-03.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Diese modifizierte QuEChERS-Methode umfasst Verd\u00fcnnungsschritte, wobei die Proben um ein Viertel verd\u00fcnnt werden. Zur Quantifizierung der 10-ng\/g-Konzentration werden Kalibrierpunkte mit 2 ng\/g oder weniger ben\u00f6tigt. Die Kalibrierkurven zeigen selbst bei niedrigen Konzentrationen gute Linearit\u00e4t (Abbildung 4) und alle Bestimmungskoeffizienten (220 Pestizide) waren gr\u00f6\u00dfer als 0.99.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 4:<\/strong>\u00a0Kalibrierkurven der sechs repr\u00e4sentativen Verbindungen<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"605\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-FSAR3080-04-1024x605.jpg\" alt=\"\" class=\"wp-image-20053\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-04-1024x605.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-04-300x177.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-04-768x454.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-04-1536x908.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-04.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Wiederfindung angereicherter Proben<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Es wurden jeweils zwei angereicherte Proben von 10 ng\/g und 50 ng\/g hergestellt (10 ng\/g-1, 10 ng\/g-2, 50 ng\/g-1, 50 ng\/g-2) und die Wiederfindungsraten wurden aus dem Durchschnitt von drei aufeinander folgenden Datenpunkten f\u00fcr jede Probe bestimmt.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">85 % der Verbindungen zeigten gute Wiederfindung zwischen 70 und 120 % bei 10 ng\/g-1 und 50 ng\/g-2. Wie oben erw\u00e4hnt wurden die angereicherten Proben auf 2.5 ng\/mL und 12.5 ng\/mL verd\u00fcnnt. Da die Kalibrierkurven gute Linearit\u00e4t bei niedrigen Konzentrationen zeigten und die modifizierte QuEChERS-Methode Interferenzen unterdr\u00fcckte, lie\u00dfen sich gute Wiederfindungsergebnisse erzielen. (Einige Verbindungen lie\u00dfen sich nicht korrekt quantifizieren, da sie in der Matrix f\u00fcr die Kalibrierstandards urspr\u00fcnglich enthalten waren. Der y-Abschnitt lag h\u00f6her und diese Verschiebung kann zu fehlerhafter Quantifizierung f\u00fchren, besonders bei niedrigen Konzentrationen. \u00dcber die Methode mit Zugabe von Standard wurden 16 Pestizide mit mehr als 10 ng\/g in der Matrix nachgewiesen.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In dieser Studie wurden die Wiederfindungsraten erneut gepr\u00fcft und mit der qualitativen Information des relativen Ionenverh\u00e4ltnisses kombiniert. Die Ionenverh\u00e4ltnisse zwischen dem Zielanalyt und der Referenz wurden mit dem des 100-ng\/g-Standards verglichen und gem\u00e4\u00df SANCO\/12571\/2013 [2] ausgewertet. Danach wird die Verwendung des relativen Verh\u00e4ltnisses mit einem Toleranzbereich von \u00b130 % als Kriterium empfohlen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tabelle I zeigt die Wiederfindung und das relative Ionenverh\u00e4ltnis f\u00fcr alle Verbindungen und Abbildung 5 zeigt das Kombinationsdiagramm der Wiederfindung und des relativen Ionenverh\u00e4ltnisses, das aus dieser Tabelle generiert wurde. 76 % der Verbindungen in der Spalte 10 ng\/g-1 lagen innerhalb von \u00b130 % des relativen Ionenverh\u00e4ltnisses mit guter Wiederfindung zwischen 70 und 120 %. F\u00fcr 50 ng\/g-2 lagen 83 % der Verbindungen innerhalb von \u00b130 % des relativen Ionenverh\u00e4ltnisses. Verbindungen mit schlechter Wiederfindung bzw. mit mehr als \u00b130 % Abweichung vom relativen Ionenverh\u00e4ltnis wurden untersucht.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Tabelle I:<\/strong>&nbsp;Wiederfindung und relatives Ionenverh\u00e4ltnis; Relative Ionenverh\u00e4ltnisse wurden f\u00fcr 100-ng\/mL-Standardl\u00f6sungen berechnet.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>ID<\/strong><\/td><td rowspan=\"2\"><strong>Substanzname<\/strong><\/td><td colspan=\"4\"><strong>\u00dcberg\u00e4nge<\/strong><\/td><td colspan=\"4\"><strong>Wiederfindung<\/strong>&nbsp;<br><strong>(Mittel aus n = 3)<\/strong><\/td><td colspan=\"4\"><strong>Relatives Ionenverh\u00e4ltnis&nbsp;<\/strong><br><strong>(Mittel aus n = 3)<\/strong><\/td><\/tr><tr><td><strong>Ziel<\/strong><\/td><td><strong>CE<\/strong><\/td><td><strong>Referenz<\/strong><\/td><td><strong>CE<\/strong><\/td><td><strong>10 ng\/g-1<\/strong><\/td><td><strong>10 ng\/g-2<\/strong><\/td><td><strong>50 ng\/g-1<\/strong><\/td><td><strong>50 ng\/g-2<\/strong><\/td><td><strong>10 ng\/g-1<\/strong><\/td><td><strong>10 ng\/g-2<\/strong><\/td><td><strong>50 ng\/g-1<\/strong><\/td><td><strong>50 ng\/g-2<\/strong><\/td><\/tr><tr><td>1<\/td><td>2,3,5,6-Tetrachloroaniline<\/td><td>228.9 &gt; 158.0<\/td><td>18<\/td><td>230.9 &gt; 158.0<\/td><td>22<\/td><td>72.5<\/td><td>67.0<\/td><td>61.4<\/td><td>68.8<\/td><td>93.6<\/td><td>97.2<\/td><td>98.9<\/td><td>101.1<\/td><\/tr><tr><td>2<\/td><td>2,4&#8242;-Methoxychlor<\/td><td>227.1 &gt; 121.1<\/td><td>16<\/td><td>228.1 &gt; 122.1<\/td><td>16<\/td><td>83.0<\/td><td>101.1<\/td><td>86.5<\/td><td>80.2<\/td><td>94.7<\/td><td>105.0<\/td><td>104.6<\/td><td>106.7<\/td><\/tr><tr><td>3<\/td><td>2-Phenylphenol<\/td><td>170.1 &gt; 141.1<\/td><td>24<\/td><td>170.1 &gt; 115.1<\/td><td>28<\/td><td>72.7<\/td><td>72.3<\/td><td>63.2<\/td><td>69.0<\/td><td>113.1<\/td><td>112.9<\/td><td>99.1<\/td><td>102.1<\/td><\/tr><tr><td>4<\/td><td>3,4-Dichloroaniline<\/td><td>161.0 &gt; 99.0<\/td><td>22<\/td><td>161.0 &gt; 126.0<\/td><td>14<\/td><td>74.5<\/td><td>66.2<\/td><td>56.4<\/td><td>64.4<\/td><td>103.8<\/td><td>105.5<\/td><td>105.8<\/td><td>106.0<\/td><\/tr><tr><td>5<\/td><td>4,4&#8242;-Dichlorobenzophenone<\/td><td>139.0 &gt; 111.0<\/td><td>14<\/td><td>139.0 &gt; 75.0<\/td><td>26<\/td><td>77.4<\/td><td>83.2<\/td><td>73.5<\/td><td>73.8<\/td><td>97.5<\/td><td>104.7<\/td><td>102.0<\/td><td>100.3<\/td><\/tr><tr><td>6<\/td><td>4,4&#8242;-methoxychlor olefin<\/td><td>308.0 &gt; 238.1<\/td><td>16<\/td><td>310.0 &gt; 238.1<\/td><td>20<\/td><td>84.4<\/td><td>94.8<\/td><td>85.7<\/td><td>83.0<\/td><td>99.4<\/td><td>101.0<\/td><td>100.0<\/td><td>98.4<\/td><\/tr><tr><td>7<\/td><td>Acequinocyl deg.<\/td><td>342.2 &gt; 188.1<\/td><td>14<\/td><td>342.2 &gt; 160.1<\/td><td>22<\/td><td>105.3<\/td><td>269.8<\/td><td>201.1<\/td><td>115.2<\/td><td>61.2<\/td><td>62.8<\/td><td>90.7<\/td><td>64.0<\/td><\/tr><tr><td>8<\/td><td>Acetochlor<\/td><td>223.1 &gt; 132.1<\/td><td>22<\/td><td>223.1 &gt; 147.1<\/td><td>10<\/td><td>77.5<\/td><td>88.3<\/td><td>77.4<\/td><td>77.1<\/td><td>109.0<\/td><td>104.1<\/td><td>102.8<\/td><td>106.2<\/td><\/tr><tr><td>9<\/td><td>Acrinathrin<\/td><td>289.1 &gt; 93.0<\/td><td>14<\/td><td>181.1 &gt; 152.1<\/td><td>26<\/td><td>102.5<\/td><td>121.4<\/td><td>91.0<\/td><td>82.4<\/td><td>87.0<\/td><td>94.7<\/td><td>92.3<\/td><td>95.1<\/td><\/tr><tr><td>10<\/td><td>Alachlor<\/td><td>188.1 &gt; 160.1<\/td><td>10<\/td><td>188.1 &gt; 132.1<\/td><td>18<\/td><td>74.1<\/td><td>87.2<\/td><td>77.8<\/td><td>74.1<\/td><td>114.7<\/td><td>107.2<\/td><td>97.3<\/td><td>103.5<\/td><\/tr><tr><td>11<\/td><td>Aldrin<\/td><td>262.9 &gt; 191.0<\/td><td>34<\/td><td>262.9 &gt; 193.0<\/td><td>28<\/td><td>86.0<\/td><td>66.9<\/td><td>65.2<\/td><td>74.3<\/td><td>79.8<\/td><td>101.1<\/td><td>104.6<\/td><td>93.2<\/td><\/tr><tr><td>12<\/td><td>Allidochlor<\/td><td>132.1 &gt; 56.0<\/td><td>8<\/td><td>132.1 &gt; 49.0<\/td><td>24<\/td><td>71.8<\/td><td>64.5<\/td><td>59.0<\/td><td>65.9<\/td><td>123.7<\/td><td>118.4<\/td><td>113.4<\/td><td>117.2<\/td><\/tr><tr><td>13<\/td><td>Anthraquinone<\/td><td>208.1 &gt; 180.1<\/td><td>10<\/td><td>208.1 &gt; 152.1<\/td><td>22<\/td><td>0.0<\/td><td>126.7<\/td><td>47.4<\/td><td>48.0<\/td><td>97.0<\/td><td>83.6<\/td><td>90.4<\/td><td>94.0<\/td><\/tr><tr><td>14<\/td><td>Atrazine<\/td><td>200.1 &gt; 104.1<\/td><td>18<\/td><td>200.1 &gt; 122.1<\/td><td>8<\/td><td>77.8<\/td><td>94.0<\/td><td>83.3<\/td><td>78.6<\/td><td>105.3<\/td><td>110.1 &nbsp;<\/td><td>92.5<\/td><td>100.6<\/td><\/tr><tr><td>15<\/td><td>Azinphos-ethyl<\/td><td>160.1 &gt; 132.1<\/td><td>4<\/td><td>160.1 &gt; 77.0<\/td><td>18<\/td><td>91.4<\/td><td>115.5<\/td><td>94.5<\/td><td>86.5<\/td><td>102.1<\/td><td>94.8<\/td><td>100.0<\/td><td>98.7<\/td><\/tr><tr><td>16<\/td><td>Azinphos-methyl<\/td><td>160.1 &gt; 132.1<\/td><td>6<\/td><td>160.1 &gt; 77.0<\/td><td>20<\/td><td>84.1<\/td><td>124.7<\/td><td>93.0<\/td><td>83.3<\/td><td>89.6<\/td><td>103.3<\/td><td>98.2<\/td><td>100.0<\/td><\/tr><tr><td>17<\/td><td>Benfluralin<\/td><td>292.1 &gt; 264.0<\/td><td>8<\/td><td>292.1 &gt; 160.0<\/td><td>22<\/td><td>78.4<\/td><td>77.0<\/td><td>64.5<\/td><td>70.7<\/td><td>97.7<\/td><td>89.1<\/td><td>96.8<\/td><td>95.3<\/td><\/tr><tr><td>18<\/td><td>BHC,&nbsp;alpha-<\/td><td>180.9 &gt; 144.9<\/td><td>16<\/td><td>218.9 &gt; 182.9<\/td><td>8<\/td><td>62.5<\/td><td>50.4<\/td><td>58.2<\/td><td>66.1<\/td><td>99.0<\/td><td>104.0<\/td><td>99.2<\/td><td>104.3<\/td><\/tr><tr><td>19<\/td><td>BHC,&nbsp;beta-<\/td><td>180.9 &gt; 144.9<\/td><td>16<\/td><td>218.9 &gt; 182.9<\/td><td>8<\/td><td>69.6<\/td><td>87.6<\/td><td>76.8<\/td><td>71.8<\/td><td>102.2<\/td><td>102.9<\/td><td>98.9<\/td><td>104.1<\/td><\/tr><tr><td>20<\/td><td>BHC,&nbsp;delta-<\/td><td>180.9 &gt; 144.9<\/td><td>16<\/td><td>218.9 &gt; 182.9<\/td><td>8<\/td><td>28.6<\/td><td>87.6<\/td><td>69.0<\/td><td>67.8<\/td><td>102.5<\/td><td>104.3<\/td><td>106.4<\/td><td>104.2<\/td><\/tr><tr><td>21<\/td><td>BHC,&nbsp;gamma-<\/td><td>180.9 &gt; 144.9<\/td><td>16<\/td><td>218.9 &gt; 182.9<\/td><td>8<\/td><td>64.1<\/td><td>73.3<\/td><td>62.0<\/td><td>69.8<\/td><td>94.8<\/td><td>93.9<\/td><td>103.1<\/td><td>102.8<\/td><\/tr><tr><td>22<\/td><td>Bifenthrin<\/td><td>181.1 &gt; 166.1<\/td><td>12<\/td><td>181.1 &gt; 179.1<\/td><td>12<\/td><td>84.6<\/td><td>99.2<\/td><td>89.3<\/td><td>81.4<\/td><td>97.0<\/td><td>104.4<\/td><td>116.7<\/td><td>105.9<\/td><\/tr><tr><td>23<\/td><td>Bioallethrin<\/td><td>123.1 &gt; 81.1<\/td><td>10<\/td><td>136.1 &gt; 93.1<\/td><td>14<\/td><td>81.7<\/td><td>100.7<\/td><td>83.6<\/td><td>71.9<\/td><td>463.4<\/td><td>563.8<\/td><td>200.4<\/td><td>228.1<\/td><\/tr><tr><td>24<\/td><td>Biphenyl<\/td><td>154.1 &gt; 128.1<\/td><td>22<\/td><td>154.1 &gt; 115.1<\/td><td>24<\/td><td>90.0<\/td><td>67.9<\/td><td>56.2<\/td><td>65.1<\/td><td>105.5<\/td><td>105.1<\/td><td>106.3<\/td><td>106.0<\/td><\/tr><tr><td>25<\/td><td>Bromfenvinfos-methyl<\/td><td>294.9 &gt; 109.0<\/td><td>16<\/td><td>296.9 &gt; 109.0<\/td><td>16<\/td><td>85.5<\/td><td>98.5<\/td><td>84.2<\/td><td>77.6<\/td><td>103.5<\/td><td>92.2<\/td><td>100.9<\/td><td>102.7<\/td><\/tr><tr><td>26<\/td><td>Bromfenvinphos<\/td><td>266.9 &gt; 159.0<\/td><td>14<\/td><td>268.9 &gt; 161.0<\/td><td>16<\/td><td>78.<\/td><td>97.8<\/td><td>88.2<\/td><td>79.2<\/td><td>102.1<\/td><td>94.7<\/td><td>100.9<\/td><td>102.3<\/td><\/tr><tr><td>27<\/td><td>Bromophos<\/td><td>330.9 &gt; 315.9<\/td><td>14<\/td><td>328.9 &gt; 313.9<\/td><td>18<\/td><td>70.9<\/td><td>86.2<\/td><td>77.2<\/td><td>76.4<\/td><td>104.6<\/td><td>98.6<\/td><td>97.2<\/td><td>98.6<\/td><\/tr><tr><td>28<\/td><td>Bromophos-ethyl<\/td><td>358.9 &gt; 302.9<\/td><td>16<\/td><td>302.9 &gt; 284.9<\/td><td>18<\/td><td>78.0<\/td><td>86.9<\/td><td>76.5<\/td><td>75.8<\/td><td>91.9<\/td><td>89.6<\/td><td>98.5<\/td><td>98.4<\/td><\/tr><tr><td>29<\/td><td>Bromopropylate<\/td><td>340.9 &gt; 182.9<\/td><td>18<\/td><td>340.9 &gt; 184.9<\/td><td>20<\/td><td>85.8<\/td><td>104.5<\/td><td>94.3<\/td><td>85.6<\/td><td>101.4<\/td><td>100.9<\/td><td>101.0<\/td><td>99.2<\/td><\/tr><tr><td>30<\/td><td>Bupirimate<\/td><td>273.1 &gt; 108.1<\/td><td>16<\/td><td>273.1 &gt; 193.1<\/td><td>8<\/td><td>94.4<\/td><td>102.8<\/td><td>92.2<\/td><td>87.0<\/td><td>82.0<\/td><td>98.3<\/td><td>98.1<\/td><td>92.8<\/td><\/tr><tr><td>31<\/td><td>Captafol<\/td><td>79.0 &gt; 77.0<\/td><td>14<\/td><td>79.0 &gt; 51.0<\/td><td>20<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><\/tr><tr><td>32<\/td><td>Captan<\/td><td>149.1 &gt; 105.1<\/td><td>4<\/td><td>149.1 &gt; 79.1<\/td><td>14<\/td><td>90.7<\/td><td>95.3<\/td><td>83.4<\/td><td>75.3<\/td><td>232.6<\/td><td>240.2<\/td><td>118.7<\/td><td>135.5<\/td><\/tr><tr><td>33<\/td><td>Carbophenothion<\/td><td>341.9 &gt; 157.0<\/td><td>14<\/td><td>341.9 &gt; 199.0<\/td><td>8<\/td><td>81.9<\/td><td>97.6<\/td><td>84.2<\/td><td>79.2<\/td><td>58.6<\/td><td>66.3<\/td><td>80.4<\/td><td>91.6<\/td><\/tr><tr><td>34<\/td><td>Carfentrazone-ethyl<\/td><td>340.1 &gt; 312.1<\/td><td>14<\/td><td>312.1 &gt; 151.1<\/td><td>24<\/td><td>85.3<\/td><td>100.6<\/td><td>94.0<\/td><td>87.3<\/td><td>81.5<\/td><td>81.8<\/td><td>101.9<\/td><td>94.7<\/td><\/tr><tr><td>35<\/td><td>Chlorbenside<\/td><td>125.0 &gt; 99.0<\/td><td>18<\/td><td>127.0 &gt; 89.0<\/td><td>18<\/td><td>80.3<\/td><td>83.4<\/td><td>73.5<\/td><td>71.8<\/td><td>86.9<\/td><td>93.5<\/td><td>96.8<\/td><td>99.3<\/td><\/tr><tr><td>36<\/td><td>Chlordane,&nbsp;cis-<\/td><td>374.8 &gt; 265.9<\/td><td>26<\/td><td>372.8 &gt; 265.9<\/td><td>22<\/td><td>76.4<\/td><td>84.2<\/td><td>76.6<\/td><td>77.1<\/td><td>94.8<\/td><td>99.2<\/td><td>105.3<\/td><td>101.1<\/td><\/tr><tr><td>37<\/td><td>Chlordane,&nbsp;trans-<\/td><td>374.8 &gt; 265.9<\/td><td>26<\/td><td>372.8 &gt; 265.9<\/td><td>22<\/td><td>76.6<\/td><td>77.3<\/td><td>75.9<\/td><td>72.9<\/td><td>96.3<\/td><td>106.5<\/td><td>103.2<\/td><td>102.7<\/td><\/tr><tr><td>38<\/td><td>Chlorfenapyr<\/td><td>247.1 &gt; 227.0<\/td><td>16<\/td><td>247.1 &gt; 200.0<\/td><td>24<\/td><td>84.3<\/td><td>114.9<\/td><td>87.1<\/td><td>85.0<\/td><td>51.3<\/td><td>71.3<\/td><td>112.2<\/td><td>98.6<\/td><\/tr><tr><td>39<\/td><td>Chlorfenson<\/td><td>175.0 &gt; 111.0<\/td><td>12<\/td><td>301.9 &gt; 175.0<\/td><td>8<\/td><td>77.0<\/td><td>89.1<\/td><td>81.4<\/td><td>76.4<\/td><td>99.5<\/td><td>100.6<\/td><td>100.5<\/td><td>98.0<\/td><\/tr><tr><td>40<\/td><td>Chlorfenvinphos, (E)-<\/td><td>323.0 &gt; 267.0<\/td><td>16<\/td><td>267.0 &gt; 159.0<\/td><td>18<\/td><td>110.3<\/td><td>114.8<\/td><td>74.7<\/td><td>72.9<\/td><td>270.4<\/td><td>484.8<\/td><td>103.9<\/td><td>99.9<\/td><\/tr><tr><td>41<\/td><td>Chlorfenvinphos, (Z)-<\/td><td>323.0 &gt; 267.0<\/td><td>16<\/td><td>267.0 &gt; 159.0<\/td><td>18<\/td><td>85.5<\/td><td>96.6<\/td><td>82.7<\/td><td>78.5<\/td><td>105.8<\/td><td>101.5<\/td><td>104.8<\/td><td>101.2<\/td><\/tr><tr><td>42<\/td><td>Chlorobenzilate<\/td><td>251.0 &gt; 139.0<\/td><td>14<\/td><td>139.0 &gt; 75.0<\/td><td>26<\/td><td>87.5<\/td><td>106.9<\/td><td>88.9<\/td><td>80.3<\/td><td>98.3<\/td><td>92.0<\/td><td>100.1<\/td><td>101.1<\/td><\/tr><tr><td>43<\/td><td>Chloroneb<\/td><td>206.0 &gt; 141.0<\/td><td>20<\/td><td>193.0 &gt; 113.0<\/td><td>18<\/td><td>65.4<\/td><td>59.8<\/td><td>59.8<\/td><td>68.6<\/td><td>111.1<\/td><td>110.8<\/td><td>107.9<\/td><td>105.9<\/td><\/tr><tr><td>44<\/td><td>Chlorothalonil<\/td><td>263.9 &gt; 168.0<\/td><td>24<\/td><td>263.9 &gt; 228.8<\/td><td>18<\/td><td>N.D.<\/td><td>N.D.<\/td><td>5.2<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>82.3<\/td><td>N.D.<\/td><\/tr><tr><td>45<\/td><td>Chlorpropham<\/td><td>213.1 &gt; 171.1<\/td><td>6<\/td><td>127.1 &gt; 92.0<\/td><td>18<\/td><td>77.7<\/td><td>81.7<\/td><td>72.5<\/td><td>73.3<\/td><td>99.6<\/td><td>101.7<\/td><td>99.0<\/td><td>101.4<\/td><\/tr><tr><td>46<\/td><td>Chlorpyrifos<\/td><td>313.9 &gt; 257.9<\/td><td>14<\/td><td>313.9 &gt; 285.9<\/td><td>8<\/td><td>71.2<\/td><td>77.8<\/td><td>74.9<\/td><td>74.2<\/td><td>100.5<\/td><td>93.8<\/td><td>93.6<\/td><td>95.7<\/td><\/tr><tr><td>47<\/td><td>Chlorpyrifos-methyl<\/td><td>285.9 &gt; 93.0<\/td><td>22<\/td><td>287.9 &gt; 93.0<\/td><td>22<\/td><td>77.0<\/td><td>89.3<\/td><td>73.1<\/td><td>75.3<\/td><td>92.9<\/td><td>91.7<\/td><td>102.6<\/td><td>98.0<\/td><\/tr><tr><td>48<\/td><td>Chlorthal-dimethyl<\/td><td>298.9 &gt; 220.9<\/td><td>24<\/td><td>300.9 &gt; 222.9<\/td><td>26<\/td><td>78.8<\/td><td>81.9<\/td><td>77.3<\/td><td>73.7<\/td><td>90.7<\/td><td>95.7<\/td><td>96.1<\/td><td>99.9<\/td><\/tr><tr><td>49<\/td><td>Chlorthiophos-1<\/td><td>256.9 &gt; 239.0<\/td><td>14<\/td><td>256.9 &gt; 193.0<\/td><td>22<\/td><td>91.4<\/td><td>108.5<\/td><td>84.2<\/td><td>83.5<\/td><td>8.4<\/td><td>49.4<\/td><td>77.2<\/td><td>68.6<\/td><\/tr><tr><td>50<\/td><td>Chlorthiophos-2<\/td><td>324.9 &gt; 268.9<\/td><td>14<\/td><td>268.9 &gt; 205.0<\/td><td>18<\/td><td>76.1<\/td><td>96.8<\/td><td>84.6<\/td><td>80.0<\/td><td>73.8<\/td><td>79.3<\/td><td>95.8<\/td><td>101.5<\/td><\/tr><tr><td>51<\/td><td>Chlorthiophos-3<\/td><td>324.9 &gt; 268.9<\/td><td>14<\/td><td>268.9 &gt; 205.0<\/td><td>18<\/td><td>78.4<\/td><td>100.2<\/td><td>86.8<\/td><td>77.8<\/td><td>92.6<\/td><td>85.9<\/td><td>100.8<\/td><td>97.8<\/td><\/tr><tr><td>52<\/td><td>Chlozolinate<\/td><td>258.9 &gt; 188.0<\/td><td>14<\/td><td>330.9 &gt; 258.9<\/td><td>6<\/td><td>75.6<\/td><td>82.2<\/td><td>75.9<\/td><td>76.1<\/td><td>91.7<\/td><td>98.3<\/td><td>103.8<\/td><td>104.3<\/td><\/tr><tr><td>53<\/td><td>Clomazone<\/td><td>204.1 &gt; 107.0<\/td><td>20<\/td><td>204.1 &gt; 78.0<\/td><td>26<\/td><td>72.7<\/td><td>72.2<\/td><td>70.9<\/td><td>74.9<\/td><td>100.7<\/td><td>99.6<\/td><td>101.8<\/td><td>98.6<\/td><\/tr><tr><td>54<\/td><td>Coumaphos<\/td><td>362.0 &gt; 109.0<\/td><td>16<\/td><td>362.0 &gt; 226.0<\/td><td>14<\/td><td>90.1<\/td><td>110.4<\/td><td>98.2<\/td><td>89.7<\/td><td>84.4<\/td><td>84.7<\/td><td>94.5<\/td><td>94.9<\/td><\/tr><tr><td>55<\/td><td>Cycloate<\/td><td>154.2 &gt; 72.0<\/td><td>6<\/td><td>215.1 &gt; 154.2<\/td><td>4<\/td><td>69.8<\/td><td>66.7<\/td><td>61.2<\/td><td>69.5<\/td><td>89.3<\/td><td>89.9<\/td><td>93.3<\/td><td>94.0<\/td><\/tr><tr><td>56<\/td><td>Cyfluthrin-1<\/td><td>226.1 &gt; 206.1<\/td><td>14<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>92.8<\/td><td>111.7<\/td><td>98.2<\/td><td>92.1<\/td><td>105.2<\/td><td>118.8<\/td><td>100.9<\/td><td>96.1<\/td><\/tr><tr><td>57<\/td><td>Cyfluthrin-2<\/td><td>226.1 &gt; 206.1<\/td><td>14<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>92.5<\/td><td>113.1<\/td><td>91.9<\/td><td>90.2<\/td><td>124.6<\/td><td>121.5<\/td><td>105.1<\/td><td>97.6<\/td><\/tr><tr><td>58<\/td><td>Cyfluthrin-3<\/td><td>226.1 &gt; 206.1<\/td><td>14<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>81.4<\/td><td>96.8<\/td><td>92.5<\/td><td>81.7<\/td><td>117.8<\/td><td>160.7<\/td><td>124.5<\/td><td>128.0<\/td><\/tr><tr><td>59<\/td><td>Cyfluthrin-4<\/td><td>226.1 &gt; 206.1<\/td><td>14<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>76.5<\/td><td>95.7<\/td><td>106.8<\/td><td>88.7<\/td><td>167.1<\/td><td>159.4<\/td><td>121.8<\/td><td>126.4<\/td><\/tr><tr><td>60<\/td><td>Cyhalothrin,&nbsp;lambda-<\/td><td>208.1 &gt; 181.1<\/td><td>8<\/td><td>197.1 &gt; 141.0<\/td><td>12<\/td><td>88.4<\/td><td>108.0<\/td><td>92.1<\/td><td>85.5<\/td><td>99.2<\/td><td>113.2<\/td><td>99.5<\/td><td>96.9<\/td><\/tr><tr><td>61<\/td><td>Cypermethrin-1<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>163.1 &gt; 109.1<\/td><td>22<\/td><td>96.0<\/td><td>113.8<\/td><td>94.6<\/td><td>89.9<\/td><td>108.8<\/td><td>93.7<\/td><td>117.4<\/td><td>111.3<\/td><\/tr><tr><td>62<\/td><td>Cypermethrin-2<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>163.1 &gt; 109.1<\/td><td>22<\/td><td>89.6<\/td><td>119.7<\/td><td>98.0<\/td><td>88.7<\/td><td>99.2<\/td><td>113.1<\/td><td>94.8<\/td><td>100.1<\/td><\/tr><tr><td>63<\/td><td>Cypermethrin-3<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>163.1 &gt; 109.1<\/td><td>22<\/td><td>75.9<\/td><td>124.9<\/td><td>103.1<\/td><td>96.9<\/td><td>126.1<\/td><td>114.1<\/td><td>96.6<\/td><td>104.1<\/td><\/tr><tr><td>64<\/td><td>Cypermethrin-4<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>163.1 &gt; 109.1<\/td><td>22<\/td><td>76.6<\/td><td>100.1<\/td><td>84.6<\/td><td>81.5<\/td><td>115.3<\/td><td>119.9<\/td><td>124.9<\/td><td>120.1<\/td><\/tr><tr><td>65<\/td><td>Cyprodinil<\/td><td>224.1 &gt; 197.1<\/td><td>22<\/td><td>224.1 &gt; 131.1<\/td><td>14<\/td><td>82.0<\/td><td>88.9<\/td><td>80.0<\/td><td>71.2<\/td><td>138.1<\/td><td>117.5<\/td><td>100.5<\/td><td>112.6<\/td><\/tr><tr><td>66<\/td><td>DDD,&nbsp;o,p&#8217;-<\/td><td>235.0 &gt; 165.0<\/td><td>24<\/td><td>235.0 &gt; 199.0<\/td><td>16<\/td><td>83.6<\/td><td>96.0<\/td><td>79.8<\/td><td>75.3<\/td><td>87.0<\/td><td>86.6<\/td><td>100.1<\/td><td>99.1<\/td><\/tr><tr><td>67<\/td><td>DDD,&nbsp;p,p&#8217;-<\/td><td>235.0 &gt; 165.0<\/td><td>24<\/td><td>235.0 &gt; 199.0<\/td><td>16<\/td><td>80.2<\/td><td>94.6<\/td><td>83.6<\/td><td>78.2<\/td><td>104.4<\/td><td>98.8<\/td><td>102.6<\/td><td>104.3<\/td><\/tr><tr><td>68<\/td><td>DDE,&nbsp;o,p&#8217;-<\/td><td>246.0 &gt; 176.0<\/td><td>30<\/td><td>248.0 &gt; 176.0<\/td><td>28<\/td><td>73.7<\/td><td>83.1<\/td><td>75.7<\/td><td>71.7<\/td><td>101.7<\/td><td>97.9<\/td><td>99.0<\/td><td>100.3<\/td><\/tr><tr><td>69<\/td><td>DDE,&nbsp;p,p&#8217;-<\/td><td>246.0 &gt; 176.0<\/td><td>30<\/td><td>317.9 &gt; 248.0<\/td><td>24<\/td><td>76.9<\/td><td>99.7<\/td><td>76.2<\/td><td>73.5<\/td><td>101.1<\/td><td>93.8<\/td><td>98.8<\/td><td>98.3<\/td><\/tr><tr><td>70<\/td><td>DDT,&nbsp;o,p&#8217;-<\/td><td>235.0 &gt; 165.0<\/td><td>24<\/td><td>235.0 &gt; 199.0<\/td><td>16<\/td><td>79.0<\/td><td>89.1<\/td><td>78.0<\/td><td>74.3<\/td><td>93.9<\/td><td>97.6<\/td><td>100.1<\/td><td>101.2<\/td><\/tr><tr><td>71<\/td><td>DDT,&nbsp;p,p&#8217;-<\/td><td>235.0 &gt; 165.0<\/td><td>24<\/td><td>235.0 &gt; 199.0<\/td><td>16<\/td><td>75.2<\/td><td>95.1<\/td><td>80.7<\/td><td>75.8<\/td><td>96.8<\/td><td>95.0<\/td><td>102.9<\/td><td>97.7<\/td><\/tr><tr><td>72<\/td><td>Deltamethrin<\/td><td>252.9 &gt; 93.0<\/td><td>20<\/td><td>252.9 &gt; 171.9<\/td><td>8<\/td><td>83.8<\/td><td>109.4<\/td><td>92.2<\/td><td>85.3<\/td><td>99.9<\/td><td>99.3<\/td><td>102.5<\/td><td>99.7<\/td><\/tr><tr><td>73<\/td><td>Di-allate-1<\/td><td>234.1 &gt; 150.0<\/td><td>20<\/td><td>234.1 &gt; 192.1<\/td><td>14<\/td><td>75.3<\/td><td>66.5<\/td><td>63.3<\/td><td>70.7<\/td><td>93.8<\/td><td>93.0<\/td><td>100.9<\/td><td>103.3<\/td><\/tr><tr><td>74<\/td><td>Di-allate-2<\/td><td>234.1 &gt; 150.0<\/td><td>20<\/td><td>234.1 &gt; 192.1<\/td><td>14<\/td><td>72.4<\/td><td>65.1<\/td><td>63.0<\/td><td>70.5<\/td><td>88.9<\/td><td>107.7<\/td><td>100.0<\/td><td>94.1<\/td><\/tr><tr><td>75<\/td><td>Diazinon<\/td><td>304.1 &gt; 179.1<\/td><td>10<\/td><td>304.1 &gt; 162.1<\/td><td>8<\/td><td>76.4<\/td><td>70.3<\/td><td>69.5<\/td><td>74.4<\/td><td>62.3<\/td><td>80.6<\/td><td>97.9<\/td><td>86.4<\/td><\/tr><tr><td>76<\/td><td>Dichlobenil<\/td><td>170.9 &gt; 100.0<\/td><td>24<\/td><td>170.9 &gt; 136.0<\/td><td>14<\/td><td>71.2<\/td><td>65.3<\/td><td>58.2<\/td><td>65.4<\/td><td>96.5<\/td><td>97.4<\/td><td>96.5<\/td><td>98.2<\/td><\/tr><tr><td>77<\/td><td>Dichlofluanid<\/td><td>223.9 &gt; 123.1<\/td><td>8<\/td><td>223.9 &gt; 77.0<\/td><td>28<\/td><td>65.0<\/td><td>71.1<\/td><td>57.8<\/td><td>56.9<\/td><td>75.4<\/td><td>87.4<\/td><td>94.4<\/td><td>101.7<\/td><\/tr><tr><td>78<\/td><td>Dicloran<\/td><td>206.0 &gt; 176.0<\/td><td>10<\/td><td>206.0 &gt; 124.0<\/td><td>24<\/td><td>78.1<\/td><td>76.6<\/td><td>69.7<\/td><td>77.0<\/td><td>79.0<\/td><td>87.7<\/td><td>100.6<\/td><td>91.0<\/td><\/tr><tr><td>79<\/td><td>Dieldrin<\/td><td>276.9 &gt; 241.0<\/td><td>8<\/td><td>262.9 &gt; 193.0<\/td><td>34<\/td><td>80.2<\/td><td>80.3<\/td><td>89.0<\/td><td>85.0<\/td><td>154.2<\/td><td>185.9<\/td><td>102.7<\/td><td>91.4<\/td><\/tr><tr><td>80<\/td><td>Dimethachlor<\/td><td>197.1 &gt; 148.1<\/td><td>10<\/td><td>199.1 &gt; 148.1<\/td><td>10<\/td><td>78.4<\/td><td>90.6<\/td><td>77.9<\/td><td>76.8<\/td><td>99.6<\/td><td>89.1<\/td><td>100.2<\/td><td>101.6<\/td><\/tr><tr><td>81<\/td><td>Diphenamid<\/td><td>239.1 &gt; 167.1<\/td><td>8<\/td><td>239.1 &gt; 72.0<\/td><td>16<\/td><td>94.7<\/td><td>96.0<\/td><td>88.3<\/td><td>79.8<\/td><td>126.1<\/td><td>123.6<\/td><td>112.2<\/td><td>115.5<\/td><\/tr><tr><td>82<\/td><td>Diphenylamine<\/td><td>169.1 &gt; 66.0<\/td><td>24<\/td><td>169.1 &gt; 77.0<\/td><td>28<\/td><td>78.2<\/td><td>74.6<\/td><td>65.6<\/td><td>71.1<\/td><td>85.3<\/td><td>99.9<\/td><td>98.3<\/td><td>100.6<\/td><\/tr><tr><td>83<\/td><td>Disulfoton<\/td><td>186.0 &gt; 153.0<\/td><td>6<\/td><td>186.0 &gt; 97.0<\/td><td>16<\/td><td>71.4<\/td><td>66.2<\/td><td>64.6<\/td><td>78.9<\/td><td>142.4<\/td><td>124.1<\/td><td>107.9<\/td><td>85.8<\/td><\/tr><tr><td>84<\/td><td>Edifenphos<\/td><td>173.0 &gt; 109.0<\/td><td>10<\/td><td>310.0 &gt; 173.0<\/td><td>14<\/td><td>82.6<\/td><td>103.7<\/td><td>91.0<\/td><td>83.6<\/td><td>97.9<\/td><td>94.6<\/td><td>100.3<\/td><td>98.2<\/td><\/tr><tr><td>85<\/td><td>Endosulfan ether<\/td><td>240.9 &gt; 205.9<\/td><td>16<\/td><td>238.9 &gt; 203.9<\/td><td>16<\/td><td>62.7<\/td><td>64.4<\/td><td>67.2<\/td><td>69.5<\/td><td>126.7<\/td><td>95.3<\/td><td>104.8<\/td><td>101.2<\/td><\/tr><tr><td>86<\/td><td>Endosulfan sulfate<\/td><td>271.8 &gt; 236.9<\/td><td>18<\/td><td>386.8 &gt; 252.9<\/td><td>16<\/td><td>83.8<\/td><td>88.4<\/td><td>87.0<\/td><td>85.1<\/td><td>42.5<\/td><td>55.6<\/td><td>83.3<\/td><td>85.8<\/td><\/tr><tr><td>87<\/td><td>Endosulfan,&nbsp;alpha-<\/td><td>194.9 &gt; 160.0<\/td><td>8<\/td><td>194.9 &gt; 125.0<\/td><td>24<\/td><td>74.0<\/td><td>80.0<\/td><td>75.6<\/td><td>80.7<\/td><td>77.6<\/td><td>76.9<\/td><td>92.3<\/td><td>83.4<\/td><\/tr><tr><td>88<\/td><td>Endosulfan,&nbsp;beta-<\/td><td>194.9 &gt; 160.0<\/td><td>8<\/td><td>194.9 &gt; 125.0<\/td><td>24<\/td><td>83.1<\/td><td>99.4<\/td><td>81.6<\/td><td>81.7<\/td><td>102.1<\/td><td>67.3<\/td><td>93.2<\/td><td>100.2<\/td><\/tr><tr><td>89<\/td><td>Endrin<\/td><td>262.9 &gt; 193.0<\/td><td>28<\/td><td>262.9 &gt; 228.0<\/td><td>22<\/td><td>84.1<\/td><td>89.9<\/td><td>77.2<\/td><td>75.3<\/td><td>50.2<\/td><td>49.4<\/td><td>85.3<\/td><td>88.2<\/td><\/tr><tr><td>90<\/td><td>Endrin aldehyde<\/td><td>249.8 &gt; 214.9<\/td><td>26<\/td><td>344.9 &gt; 244.9<\/td><td>16<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><\/tr><tr><td>91<\/td><td>Endrin ketone<\/td><td>316.9 &gt; 244.9<\/td><td>20<\/td><td>314.9 &gt; 242.9<\/td><td>18<\/td><td>73.4<\/td><td>91.5<\/td><td>84.1<\/td><td>88.0<\/td><td>108.9<\/td><td>95.4<\/td><td>107.6<\/td><td>101.9<\/td><\/tr><tr><td>92<\/td><td>EPN<\/td><td>169.1 &gt; 140.9<\/td><td>8<\/td><td>169.1 &gt; 77.0<\/td><td>22<\/td><td>90.3<\/td><td>107.4<\/td><td>89.2<\/td><td>82.3<\/td><td>94.3<\/td><td>102.9<\/td><td>100.2<\/td><td>98.8<\/td><\/tr><tr><td>93<\/td><td>Ethalfluralin<\/td><td>276.0 &gt; 202.0<\/td><td>18<\/td><td>316.1 &gt; 276.0<\/td><td>10<\/td><td>73.3<\/td><td>67.7<\/td><td>63.0<\/td><td>67.1<\/td><td>95.2<\/td><td>96.4<\/td><td>100.9<\/td><td>100.6<\/td><\/tr><tr><td>94<\/td><td>Ethion<\/td><td>230.9 &gt; 129.0<\/td><td>24<\/td><td>230.9 &gt; 174.9<\/td><td>14<\/td><td>81.4<\/td><td>97.1<\/td><td>84.2<\/td><td>77.9<\/td><td>118.3<\/td><td>108.6<\/td><td>101.8<\/td><td>102.6<\/td><\/tr><tr><td>95<\/td><td>Etofenprox<\/td><td>163.1 &gt; 135.1<\/td><td>10<\/td><td>163.1 &gt; 107.1<\/td><td>18<\/td><td>87.1<\/td><td>101.1<\/td><td>95.6<\/td><td>87.3<\/td><td>97.4<\/td><td>103.1<\/td><td>98.8<\/td><td>97.8<\/td><\/tr><tr><td>96<\/td><td>Etridiazole<\/td><td>210.9 &gt; 182.9<\/td><td>10<\/td><td>210.9 &gt; 139.9<\/td><td>22<\/td><td>70.0<\/td><td>60.1<\/td><td>58.0<\/td><td>66.9<\/td><td>88.2<\/td><td>102.0<\/td><td>102.0<\/td><td>100.4<\/td><\/tr><tr><td>97<\/td><td>Fenamiphos<\/td><td>303.1 &gt; 195.1<\/td><td>8<\/td><td>288.1 &gt; 260.1<\/td><td>6<\/td><td>88.7<\/td><td>104.6<\/td><td>99.3<\/td><td>87.1<\/td><td>120.9<\/td><td>106.0<\/td><td>96.8<\/td><td>100.1<\/td><\/tr><tr><td>98<\/td><td>Fenarimol<\/td><td>251.0 &gt; 139.0<\/td><td>14<\/td><td>330.0 &gt; 139.0<\/td><td>8<\/td><td>83.9<\/td><td>106.7<\/td><td>96.5<\/td><td>89.4<\/td><td>97.4<\/td><td>92.6<\/td><td>99.3<\/td><td>96.0<\/td><\/tr><tr><td>99<\/td><td>Fenchlorphos<\/td><td>284.9 &gt; 269.9<\/td><td>16<\/td><td>286.9 &gt; 271.9<\/td><td>18<\/td><td>80.5<\/td><td>81.4<\/td><td>71.5<\/td><td>74.8<\/td><td>89.8<\/td><td>83.8<\/td><td>99.1<\/td><td>97.2<\/td><\/tr><tr><td>100<\/td><td>Fenitrothion<\/td><td>277.0 &gt; 260.0<\/td><td>6<\/td><td>260.0 &gt; 125.1<\/td><td>12<\/td><td>78.0<\/td><td>89.3<\/td><td>79.3<\/td><td>75.8<\/td><td>104.9<\/td><td>99.2<\/td><td>111.4<\/td><td>109.6<\/td><\/tr><tr><td>101<\/td><td>Fenpropathrin<\/td><td>265.1 &gt; 210.1<\/td><td>12<\/td><td>265.1 &gt; 89.0<\/td><td>28<\/td><td>90.3<\/td><td>102.8<\/td><td>96.8<\/td><td>88.2<\/td><td>68.9<\/td><td>75.9<\/td><td>90.9<\/td><td>94.4<\/td><\/tr><tr><td>102<\/td><td>Fenson<\/td><td>141.0 &gt; 77.0<\/td><td>16<\/td><td>267.9 &gt; 141.0<\/td><td>6<\/td><td>78.3<\/td><td>88.0<\/td><td>77.9<\/td><td>74.5<\/td><td>91.3<\/td><td>92.7<\/td><td>100.8<\/td><td>96.8<\/td><\/tr><tr><td>103<\/td><td>Fenthion<\/td><td>278.0 &gt; 169.0<\/td><td>14<\/td><td>278.0 &gt; 125.0<\/td><td>20<\/td><td>80.4<\/td><td>81.9<\/td><td>78.2<\/td><td>76.0<\/td><td>93.9<\/td><td>96.0<\/td><td>102.2<\/td><td>104.1<\/td><\/tr><tr><td>104<\/td><td>Fenvalerate-1<\/td><td>225.1 &gt; 147.1<\/td><td>10<\/td><td>419.1 &gt; 225.1<\/td><td>6<\/td><td>82.2<\/td><td>100.7<\/td><td>94.6<\/td><td>88.9<\/td><td>95.5<\/td><td>92.4<\/td><td>103.2<\/td><td>99.3<\/td><\/tr><tr><td>105<\/td><td>Fenvalerate-2<\/td><td>225.1 &gt; 147.1<\/td><td>10<\/td><td>419.1 &gt; 225.1<\/td><td>6<\/td><td>75.7<\/td><td>106.7<\/td><td>93.1<\/td><td>86.5<\/td><td>73.5<\/td><td>70.0<\/td><td>86.2<\/td><td>89.7<\/td><\/tr><tr><td>106<\/td><td>Fipronil<\/td><td>366.9 &gt; 212.9<\/td><td>30<\/td><td>368.9 &gt; 214.9<\/td><td>30<\/td><td>92.8<\/td><td>113.2<\/td><td>99.5<\/td><td>82.8<\/td><td>93.8<\/td><td>96.2<\/td><td>88.0<\/td><td>96.7<\/td><\/tr><tr><td>107<\/td><td>Fluazifop-P-butyl<\/td><td>282.1 &gt; 91.0<\/td><td>18<\/td><td>383.1 &gt; 282.1<\/td><td>14<\/td><td>77.4<\/td><td>94.0<\/td><td>89.0<\/td><td>80.6<\/td><td>101.9<\/td><td>96.4<\/td><td>99.6<\/td><td>100.5<\/td><\/tr><tr><td>108<\/td><td>Fluchloralin<\/td><td>306.0 &gt; 264.0<\/td><td>8<\/td><td>326.0 &gt; 63.0<\/td><td>16<\/td><td>76.4<\/td><td>78.4<\/td><td>76.9<\/td><td>75.1<\/td><td>95.8<\/td><td>96.0<\/td><td>90.4<\/td><td>96.5<\/td><\/tr><tr><td>109<\/td><td>Flucythrinate-1<\/td><td>157.1 &gt; 107.1<\/td><td>12<\/td><td>199.1 &gt; 107.1<\/td><td>22<\/td><td>86.9<\/td><td>111.9<\/td><td>95.6<\/td><td>87.3<\/td><td>119.8<\/td><td>120.4<\/td><td>107.1<\/td><td>105.2<\/td><\/tr><tr><td>110<\/td><td>Flucythrinate-2<\/td><td>157.1 &gt; 107.1<\/td><td>12<\/td><td>199.1 &gt; 107.1<\/td><td>22<\/td><td>89.4<\/td><td>111.0<\/td><td>96.0<\/td><td>86.6<\/td><td>105.1<\/td><td>108.4<\/td><td>102.6<\/td><td>104.6<\/td><\/tr><tr><td>111<\/td><td>Fludioxonil<\/td><td>248.0 &gt; 127.0<\/td><td>26<\/td><td>248.0 &gt; 154.0<\/td><td>20<\/td><td>94.1<\/td><td>110.3<\/td><td>96.5<\/td><td>86.1<\/td><td>91.9<\/td><td>101.1<\/td><td>98.1<\/td><td>96.0<\/td><\/tr><tr><td>112<\/td><td>Fluquinconazole<\/td><td>340.0 &gt; 298.0<\/td><td>20<\/td><td>340.0 &gt; 313.0<\/td><td>14<\/td><td>85.2<\/td><td>107.0<\/td><td>98.9<\/td><td>88.9<\/td><td>97.7<\/td><td>98.5<\/td><td>101.4<\/td><td>101.1<\/td><\/tr><tr><td>113<\/td><td>Fluridone<\/td><td>328.1 &gt; 259.0<\/td><td>24<\/td><td>328.1 &gt; 127.0<\/td><td>24<\/td><td>91.5<\/td><td>117.7<\/td><td>100.3<\/td><td>91.4<\/td><td>80.1<\/td><td>77.3<\/td><td>93.4<\/td><td>95.7<\/td><\/tr><tr><td>114<\/td><td>Flusilazole<\/td><td>233.1 &gt; 165.1<\/td><td>14<\/td><td>233.1 &gt; 152.1<\/td><td>14<\/td><td>78.1<\/td><td>93.3<\/td><td>84.9<\/td><td>83.2<\/td><td>105.9<\/td><td>91.5<\/td><td>94.8<\/td><td>95.4<\/td><\/tr><tr><td>115<\/td><td>Flutolanil<\/td><td>173.0 &gt; 95.0<\/td><td>26<\/td><td>281.1 &gt; 173.0<\/td><td>12<\/td><td>84.1<\/td><td>108.0<\/td><td>93.4<\/td><td>84.7<\/td><td>104.1<\/td><td>101.1<\/td><td>100.0<\/td><td>99.8<\/td><\/tr><tr><td>116<\/td><td>Flutriafol<\/td><td>219.1 &gt; 123.1<\/td><td>14<\/td><td>219.1 &gt; 95.0<\/td><td>28<\/td><td>82.9<\/td><td>109.6<\/td><td>89.8<\/td><td>84.2<\/td><td>120.1<\/td><td>115.2<\/td><td>103.9<\/td><td>103.9<\/td><\/tr><tr><td>117<\/td><td>Fluvalinate-1,&nbsp;tau-<\/td><td>250.1 &gt; 55.0<\/td><td>18<\/td><td>250.1 &gt; 200.1<\/td><td>16<\/td><td>86.7<\/td><td>112.8<\/td><td>91.9<\/td><td>85.5<\/td><td>79.4<\/td><td>79.9<\/td><td>90.8<\/td><td>90.4<\/td><\/tr><tr><td>118<\/td><td>Fluvalinate-2,&nbsp;tau-<\/td><td>250.1 &gt; 55.0<\/td><td>18<\/td><td>250.1 &gt; 200.1<\/td><td>16<\/td><td>90.4<\/td><td>112.0<\/td><td>89.1<\/td><td>83.9<\/td><td>89.6<\/td><td>95.5<\/td><td>102.5<\/td><td>104.7<\/td><\/tr><tr><td>119<\/td><td>Folpet<\/td><td>259.9 &gt; 130.0<\/td><td>14<\/td><td>261.9 &gt; 130.0<\/td><td>18<\/td><td>65.2<\/td><td>82.9<\/td><td>72.8<\/td><td>67.0<\/td><td>97.2<\/td><td>89.1<\/td><td>99.1<\/td><td>98.3<\/td><\/tr><tr><td>120<\/td><td>Fonofos<\/td><td>246.0 &gt; 137.1<\/td><td>6<\/td><td>246.0 &gt; 109.1<\/td><td>18<\/td><td>76.6<\/td><td>74.7<\/td><td>65.8<\/td><td>71.4<\/td><td>106.8<\/td><td>97.6<\/td><td>102.1<\/td><td>101.2<\/td><\/tr><tr><td>121<\/td><td>Heptachlor<\/td><td>271.8 &gt; 236.9<\/td><td>20<\/td><td>273.8 &gt; 238.9<\/td><td>16<\/td><td>68.6<\/td><td>65.4<\/td><td>65.0<\/td><td>68.6<\/td><td>92.3<\/td><td>102.0<\/td><td>104.0<\/td><td>101.2<\/td><\/tr><tr><td>122<\/td><td>Heptachlor-exo-epoxide<\/td><td>352.8 &gt; 262.9<\/td><td>14<\/td><td>352.8 &gt; 316.9<\/td><td>10<\/td><td>81.1<\/td><td>80.4<\/td><td>71.8<\/td><td>79.1<\/td><td>33.7<\/td><td>39.0<\/td><td>88.6<\/td><td>71.5<\/td><\/tr><tr><td>123<\/td><td>Hexachlorobenzene<\/td><td>283.8 &gt; 248.8<\/td><td>24<\/td><td>283.8 &gt; 213.8<\/td><td>28<\/td><td>45.7<\/td><td>28.8<\/td><td>48.1<\/td><td>62.3<\/td><td>101.4<\/td><td>100.7<\/td><td>102.7<\/td><td>99.3<\/td><\/tr><tr><td>124<\/td><td>Hexazinone<\/td><td>171.1 &gt; 71.0<\/td><td>16<\/td><td>171.1 &gt; 85.0<\/td><td>16<\/td><td>93.2<\/td><td>112.9<\/td><td>96.1<\/td><td>88.2<\/td><td>105.3<\/td><td>101.3<\/td><td>104.0<\/td><td>105.2<\/td><\/tr><tr><td>125<\/td><td>Iodofenphos<\/td><td>376.9 &gt; 361.8<\/td><td>22<\/td><td>376.9 &gt; 331.8<\/td><td>32<\/td><td>80.0<\/td><td>86.8<\/td><td>75.8<\/td><td>74.2<\/td><td>83.8<\/td><td>102.3<\/td><td>97.3<\/td><td>97.1<\/td><\/tr><tr><td>126<\/td><td>Iprodione<\/td><td>314.0 &gt; 245.0<\/td><td>12<\/td><td>314.0 &gt; 56.0<\/td><td>22<\/td><td>110.5<\/td><td>156.0<\/td><td>102.0<\/td><td>89.9<\/td><td>91.0<\/td><td>99.9<\/td><td>102.2<\/td><td>107.0<\/td><\/tr><tr><td>127<\/td><td>Isazofos<\/td><td>257.0 &gt; 162.0<\/td><td>8<\/td><td>257.0 &gt; 119.0<\/td><td>18<\/td><td>80.0<\/td><td>87.4<\/td><td>74.4<\/td><td>74.7<\/td><td>109.5<\/td><td>107.1<\/td><td>96.0<\/td><td>102.6<\/td><\/tr><tr><td>128<\/td><td>Isodrin<\/td><td>192.9 &gt; 157.0<\/td><td>20<\/td><td>262.9 &gt; 192.9<\/td><td>28<\/td><td>76.4<\/td><td>73.7<\/td><td>67.4<\/td><td>71.2<\/td><td>88.2<\/td><td>99.0<\/td><td>110.1<\/td><td>98.6<\/td><\/tr><tr><td>129<\/td><td>Isopropalin<\/td><td>280.1 &gt; 238.1<\/td><td>8<\/td><td>280.1 &gt; 133.1<\/td><td>18<\/td><td>76.5<\/td><td>88.1<\/td><td>73.6<\/td><td>71.4<\/td><td>89.8<\/td><td>82.7<\/td><td>97.9<\/td><td>106.1<\/td><\/tr><tr><td>130<\/td><td>Lenacil<\/td><td>153.1 &gt; 136.1<\/td><td>14<\/td><td>153.1 &gt; 82.1<\/td><td>16<\/td><td>85.1<\/td><td>103.2<\/td><td>97.5<\/td><td>85.7<\/td><td>109.0<\/td><td>108.9<\/td><td>124.1<\/td><td>111.8<\/td><\/tr><tr><td>131<\/td><td>Leptophos<\/td><td>376.9 &gt; 361.9<\/td><td>24<\/td><td>374.9 &gt; 359.9<\/td><td>24<\/td><td>86.8<\/td><td>102.6<\/td><td>89.0<\/td><td>82.6<\/td><td>95.4<\/td><td>99.8<\/td><td>101.9<\/td><td>103.0<\/td><\/tr><tr><td>132<\/td><td>Linuron<\/td><td>248.0 &gt; 61.0<\/td><td>16<\/td><td>250.0 &gt; 61.0<\/td><td>16<\/td><td>68.3<\/td><td>84.7<\/td><td>77.7<\/td><td>77.9<\/td><td>98.3<\/td><td>83.1<\/td><td>105.8<\/td><td>108.6<\/td><\/tr><tr><td>133<\/td><td>Malathion<\/td><td>173.1 &gt; 99.0<\/td><td>14<\/td><td>158.1 &gt; 125.0<\/td><td>10<\/td><td>79.9<\/td><td>87.3<\/td><td>77.6<\/td><td>75.3<\/td><td>95.2<\/td><td>97.4<\/td><td>101.3<\/td><td>100.9<\/td><\/tr><tr><td>134<\/td><td>Metalaxyl<\/td><td>249.2 &gt; 190.1<\/td><td>8<\/td><td>249.2 &gt; 146.1<\/td><td>22<\/td><td>83.5<\/td><td>88.7<\/td><td>89.5<\/td><td>81.1<\/td><td>103.0<\/td><td>122.4<\/td><td>104.0<\/td><td>100.7<\/td><\/tr><tr><td>135<\/td><td>Metazachlor<\/td><td>209.1 &gt; 132.1<\/td><td>18<\/td><td>211.1 &gt; 132.1<\/td><td>20<\/td><td>83.3<\/td><td>93.2<\/td><td>83.8<\/td><td>80.1<\/td><td>97.8<\/td><td>100.1<\/td><td>101.6<\/td><td>104.8<\/td><\/tr><tr><td>136<\/td><td>Methacrifos<\/td><td>208.0 &gt; 180.0<\/td><td>8<\/td><td>240.0 &gt; 208.0<\/td><td>4<\/td><td>75.6<\/td><td>68.7<\/td><td>62.9<\/td><td>67.2<\/td><td>93.3<\/td><td>89.0<\/td><td>95.3<\/td><td>101.8<\/td><\/tr><tr><td>137<\/td><td>Methoxychlor<\/td><td>227.1 &gt; 169.1<\/td><td>24<\/td><td>227.1 &gt; 212.1<\/td><td>14<\/td><td>82.8<\/td><td>101.8<\/td><td>90.8<\/td><td>83.5<\/td><td>109.0<\/td><td>108.5<\/td><td>103.5<\/td><td>103.2<\/td><\/tr><tr><td>138<\/td><td>Metolachlor<\/td><td>238.1 &gt; 162.1<\/td><td>12<\/td><td>238.1 &gt; 133.1<\/td><td>26<\/td><td>77.0<\/td><td>89.0<\/td><td>77.9<\/td><td>75.4<\/td><td>104.8<\/td><td>96.6<\/td><td>101.4<\/td><td>102.3<\/td><\/tr><tr><td>139<\/td><td>Mevinphos-1<\/td><td>192.0 &gt; 127.0<\/td><td>12<\/td><td>127.0 &gt; 95.0<\/td><td>18<\/td><td>75.7<\/td><td>70.7<\/td><td>64.1<\/td><td>71.4<\/td><td>95.8<\/td><td>104.8<\/td><td>103.6<\/td><td>102.2<\/td><\/tr><tr><td>140<\/td><td>MGK 264-1<\/td><td>164.1 &gt; 93.0<\/td><td>10<\/td><td>164.1 &gt; 80.0<\/td><td>24<\/td><td>112.8<\/td><td>102.9<\/td><td>86.2<\/td><td>81.3<\/td><td>92.5<\/td><td>104.4<\/td><td>108.1<\/td><td>104.7<\/td><\/tr><tr><td>141<\/td><td>MGK 264-2<\/td><td>164.1 &gt; 98.0<\/td><td>12<\/td><td>164.1 &gt; 67.0<\/td><td>8<\/td><td>74.8<\/td><td>89.7<\/td><td>79.3<\/td><td>78.2<\/td><td>116.0<\/td><td>100.8<\/td><td>93.7<\/td><td>96.0<\/td><\/tr><tr><td>142<\/td><td>Mirex<\/td><td>271.8 &gt; 236.8<\/td><td>18<\/td><td>273.8 &gt; 238.8<\/td><td>18<\/td><td>71.4<\/td><td>80.4<\/td><td>73.6<\/td><td>71.2<\/td><td>99.9<\/td><td>97.3<\/td><td>100.7<\/td><td>99.6<\/td><\/tr><tr><td>143<\/td><td>Myclobutanil<\/td><td>179.1 &gt; 125.0<\/td><td>14<\/td><td>179.1 &gt; 152.0<\/td><td>8<\/td><td>83.7<\/td><td>104.4<\/td><td>90.8<\/td><td>84.1<\/td><td>122.4<\/td><td>127.5<\/td><td>112.5<\/td><td>108.8<\/td><\/tr><tr><td>144<\/td><td>N-(2,4-dimethylphenyl) formamide<\/td><td>149.1 &gt; 106.1<\/td><td>16<\/td><td>149.1 &gt; 121.1<\/td><td>6<\/td><td>86.6<\/td><td>88.5<\/td><td>73.0<\/td><td>71.4<\/td><td>334.2<\/td><td>367.6<\/td><td>157.5<\/td><td>169.6<\/td><\/tr><tr><td>145<\/td><td>Nitralin<\/td><td>316.1 &gt; 274.0<\/td><td>8<\/td><td>274.0 &gt; 169.0<\/td><td>12<\/td><td>101.1<\/td><td>116.0<\/td><td>95.4<\/td><td>87.2<\/td><td>98.7<\/td><td>104.0<\/td><td>106.2<\/td><td>97.4<\/td><\/tr><tr><td>146<\/td><td>Nitrofen<\/td><td>202.0 &gt; 139.0<\/td><td>24<\/td><td>282.9 &gt; 253.0<\/td><td>12<\/td><td>83.4<\/td><td>91.9<\/td><td>85.9<\/td><td>77.0<\/td><td>89.0<\/td><td>95.2<\/td><td>99.6<\/td><td>104.3<\/td><\/tr><tr><td>147<\/td><td>Nonachlor,&nbsp;cis-<\/td><td>406.8 &gt; 299.9<\/td><td>24<\/td><td>406.8 &gt; 334.9<\/td><td>16<\/td><td>80.0<\/td><td>91.3<\/td><td>79.8<\/td><td>77.0<\/td><td>59.7<\/td><td>48.5<\/td><td>84.3<\/td><td>87.0<\/td><\/tr><tr><td>148<\/td><td>Nonachlor,&nbsp;trans-<\/td><td>406.8 &gt; 299.9<\/td><td>24<\/td><td>406.8 &gt; 334.9<\/td><td>16<\/td><td>74.8<\/td><td>86.0<\/td><td>80.8<\/td><td>78.2<\/td><td>58.4<\/td><td>72.4<\/td><td>82.3<\/td><td>84.6<\/td><\/tr><tr><td>149<\/td><td>Norflurazon<\/td><td>303.0 &gt; 145.0<\/td><td>22<\/td><td>145.0 &gt; 95.0<\/td><td>18<\/td><td>94.7<\/td><td>111.0<\/td><td>98.7<\/td><td>85.0<\/td><td>92.7<\/td><td>95.4<\/td><td>99.2<\/td><td>100.8<\/td><\/tr><tr><td>150<\/td><td>Oxadiazon<\/td><td>258.0 &gt; 175.0<\/td><td>8<\/td><td>302.0 &gt; 175.0<\/td><td>14<\/td><td>78.8<\/td><td>88.7<\/td><td>84.7<\/td><td>76.9<\/td><td>95.1<\/td><td>101.4<\/td><td>100.4<\/td><td>103.2<\/td><\/tr><tr><td>151<\/td><td>Oxyfluorfen<\/td><td>361.0 &gt; 300.0<\/td><td>14<\/td><td>361.0 &gt; 317.0<\/td><td>6<\/td><td>101.4<\/td><td>106.2<\/td><td>90.9<\/td><td>80.4<\/td><td>91.2<\/td><td>97.7<\/td><td>101.4<\/td><td>102.1<\/td><\/tr><tr><td>152<\/td><td>Paclobutrazol<\/td><td>236.1 &gt; 125.0<\/td><td>14<\/td><td>236.1 &gt; 167.0<\/td><td>10<\/td><td>92.2<\/td><td>116.7<\/td><td>92.8<\/td><td>86.1<\/td><td>98.0<\/td><td>86.2<\/td><td>100.9<\/td><td>100.1<\/td><\/tr><tr><td>153<\/td><td>Parathion<\/td><td>291.1 &gt; 137.0<\/td><td>6<\/td><td>291.1 &gt; 81.0<\/td><td>24<\/td><td>99.8<\/td><td>96.8<\/td><td>80.7<\/td><td>76.0<\/td><td>100.1<\/td><td>115.2<\/td><td>104.9<\/td><td>108.1<\/td><\/tr><tr><td>154<\/td><td>Parathion-methyl<\/td><td>263.0 &gt; 109.0<\/td><td>14<\/td><td>263.0 &gt; 246.0<\/td><td>6<\/td><td>85.5<\/td><td>91.6<\/td><td>74.2<\/td><td>77.4<\/td><td>71.7<\/td><td>69.8<\/td><td>96.2<\/td><td>93.7<\/td><\/tr><tr><td>155<\/td><td>Pebulate<\/td><td>161.1 &gt; 128.1<\/td><td>6<\/td><td>128.1 &gt; 57.0<\/td><td>6<\/td><td>64.1<\/td><td>59.1<\/td><td>56.9<\/td><td>66.7<\/td><td>115.3<\/td><td>111.1<\/td><td>101.3<\/td><td>101.7<\/td><\/tr><tr><td>156<\/td><td>Penconazole<\/td><td>248.1 &gt; 157.1<\/td><td>26<\/td><td>159.1 &gt; 123.1<\/td><td>22<\/td><td>90.9<\/td><td>92.6<\/td><td>75.3<\/td><td>75.4<\/td><td>90.0<\/td><td>94.4<\/td><td>97.6<\/td><td>97.5<\/td><\/tr><tr><td>157<\/td><td>Pendimethalin<\/td><td>252.1 &gt; 162.1<\/td><td>10<\/td><td>252.1 &gt; 191.1<\/td><td>8<\/td><td>84.0<\/td><td>84.2<\/td><td>73.9<\/td><td>73.8<\/td><td>89.5<\/td><td>98.9<\/td><td>102.2<\/td><td>104.0<\/td><\/tr><tr><td>158<\/td><td>Pentachloroaniline<\/td><td>262.9 &gt; 191.9<\/td><td>22<\/td><td>264.9 &gt; 193.9<\/td><td>18<\/td><td>23.6<\/td><td>83.6<\/td><td>52.0<\/td><td>72.4<\/td><td>99.4<\/td><td>99.0<\/td><td>101.1<\/td><td>98.8<\/td><\/tr><tr><td>159<\/td><td>Pentachloroanisole<\/td><td>279.9 &gt; 236.8<\/td><td>26<\/td><td>279.9 &gt; 264.8<\/td><td>12<\/td><td>69.0<\/td><td>65.8<\/td><td>60.2<\/td><td>67.9<\/td><td>102.8<\/td><td>93.3<\/td><td>101.7<\/td><td>101.4<\/td><\/tr><tr><td>160<\/td><td>Pentachlorobenzene<\/td><td>249.9 &gt; 214.9<\/td><td>18<\/td><td>249.9 &gt; 176.9<\/td><td>26<\/td><td>59.9<\/td><td>27.0<\/td><td>47.6<\/td><td>62.0<\/td><td>104.3<\/td><td>113.2<\/td><td>108.4<\/td><td>104.3<\/td><\/tr><tr><td>161<\/td><td>Pentachlorobenzonitrile<\/td><td>274.8 &gt; 239.8<\/td><td>18<\/td><td>272.8 &gt; 202.9<\/td><td>30<\/td><td>69.3<\/td><td>65.6<\/td><td>63.2<\/td><td>68.7<\/td><td>90.1<\/td><td>88.2<\/td><td>96.3<\/td><td>95.7<\/td><\/tr><tr><td>162<\/td><td>Pentachlorothioanisole<\/td><td>295.8 &gt; 262.9<\/td><td>14<\/td><td>295.8 &gt; 245.8<\/td><td>30<\/td><td>55.8<\/td><td>75.7<\/td><td>62.7<\/td><td>69.7<\/td><td>92.4<\/td><td>96.3<\/td><td>94.9<\/td><td>93.5<\/td><\/tr><tr><td>163<\/td><td>Permethrine,&nbsp;cis-<\/td><td>183.1 &gt; 153.1<\/td><td>14<\/td><td>183.1 &gt; 168.1<\/td><td>14<\/td><td>86.6<\/td><td>112.1<\/td><td>96.8<\/td><td>87.5<\/td><td>101.7<\/td><td>108.3<\/td><td>99.5<\/td><td>100.2<\/td><\/tr><tr><td>164<\/td><td>Permethrine,&nbsp;trans-<\/td><td>183.1 &gt; 153.1<\/td><td>14<\/td><td>183.1 &gt; 168.1<\/td><td>14<\/td><td>96.0<\/td><td>131.5<\/td><td>97.0<\/td><td>88.4<\/td><td>100.4<\/td><td>98.3<\/td><td>103.6<\/td><td>102.4<\/td><\/tr><tr><td>165<\/td><td>Perthane<\/td><td>223.2 &gt; 167.1<\/td><td>14<\/td><td>223.2 &gt; 193.1<\/td><td>28<\/td><td>85.3<\/td><td>92.7<\/td><td>81.9<\/td><td>78.1<\/td><td>97.1<\/td><td>106.8<\/td><td>102.3<\/td><td>100.3<\/td><\/tr><tr><td>166<\/td><td>Phenothrin-1<\/td><td>183.1 &gt; 153.1<\/td><td>14<\/td><td>183.1 &gt; 168.1<\/td><td>14<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>84.8<\/td><td>N.D.<\/td><td>N.D.<\/td><td>111.5<\/td><td>92.4<\/td><\/tr><tr><td>167<\/td><td>Phenothrin-2<\/td><td>183.1 &gt; 153.1<\/td><td>14<\/td><td>183.1 &gt; 168.1<\/td><td>14<\/td><td>100.7<\/td><td>113.7<\/td><td>95.7<\/td><td>86.7<\/td><td>101.4<\/td><td>112.1<\/td><td>105.1<\/td><td>100.1<\/td><\/tr><tr><td>168<\/td><td>Phorate<\/td><td>260.0 &gt; 75.0<\/td><td>8<\/td><td>231.0 &gt; 129.0<\/td><td>24<\/td><td>74.3<\/td><td>63.8<\/td><td>61.9<\/td><td>69.7<\/td><td>92.7<\/td><td>116.3<\/td><td>99.8<\/td><td>101.6<\/td><\/tr><tr><td>169<\/td><td>Phosalone<\/td><td>182.0 &gt; 102.0<\/td><td>14<\/td><td>182.0 &gt; 111.0<\/td><td>14<\/td><td>86.3<\/td><td>101.6<\/td><td>93.9<\/td><td>84.4<\/td><td>117.0<\/td><td>123.8<\/td><td>101.2<\/td><td>104.5<\/td><\/tr><tr><td>170<\/td><td>Phosmet<\/td><td>160.0 &gt; 77.0<\/td><td>24<\/td><td>160.0 &gt; 105.0<\/td><td>18<\/td><td>86.7<\/td><td>105.4<\/td><td>92.6<\/td><td>83.0<\/td><td>100.8<\/td><td>100.1<\/td><td>103.5<\/td><td>101.2<\/td><\/tr><tr><td>171<\/td><td>Piperonyl butoxide<\/td><td>176.1 &gt; 131.1<\/td><td>12<\/td><td>176.1 &gt; 117.1<\/td><td>20<\/td><td>84.1<\/td><td>112.8<\/td><td>92.1<\/td><td>85.9<\/td><td>104.9<\/td><td>118.6<\/td><td>102.2<\/td><td>102.3<\/td><\/tr><tr><td>172<\/td><td>Pirimiphos ethyl<\/td><td>304.1 &gt; 168.1<\/td><td>12<\/td><td>318.1 &gt; 166.1<\/td><td>12<\/td><td>78.1<\/td><td>94.3<\/td><td>79.1<\/td><td>73.8<\/td><td>83.5<\/td><td>84.4<\/td><td>97.4<\/td><td>105.8<\/td><\/tr><tr><td>173<\/td><td>Pirimiphos-methyl<\/td><td>290.1 &gt; 125.0<\/td><td>22<\/td><td>290.1 &gt; 233.1<\/td><td>12<\/td><td>80.4<\/td><td>88.9<\/td><td>78.5<\/td><td>76.1<\/td><td>93.3<\/td><td>92.5<\/td><td>101.2<\/td><td>99.4<\/td><\/tr><tr><td>174<\/td><td>Pretilachlor<\/td><td>262.1 &gt; 202.1<\/td><td>10<\/td><td>238.1 &gt; 162.1<\/td><td>10<\/td><td>77.0<\/td><td>95.2<\/td><td>86.0<\/td><td>79.7<\/td><td>109.6<\/td><td>79.5<\/td><td>93.4<\/td><td>102.5<\/td><\/tr><tr><td>175<\/td><td>Prochloraz<\/td><td>180.1 &gt; 138.1<\/td><td>12<\/td><td>180.1 &gt; 69.0<\/td><td>20<\/td><td>68.1<\/td><td>110.1<\/td><td>85.4<\/td><td>81.5<\/td><td>106.2<\/td><td>102.1<\/td><td>91.1<\/td><td>91.2<\/td><\/tr><tr><td>176<\/td><td>Procymidone<\/td><td>283.0 &gt; 96.0<\/td><td>10<\/td><td>285.0 &gt; 96.0<\/td><td>10<\/td><td>12.4<\/td><td>140.1<\/td><td>78.8<\/td><td>79.4<\/td><td>103.0<\/td><td>101.7<\/td><td>104.7<\/td><td>101.8<\/td><\/tr><tr><td>177<\/td><td>Prodiamine<\/td><td>321.1 &gt; 279.1<\/td><td>6<\/td><td>321.1 &gt; 203.1<\/td><td>10<\/td><td>86.1<\/td><td>94.7<\/td><td>81.6<\/td><td>78.3<\/td><td>88.5<\/td><td>88.3<\/td><td>93.6<\/td><td>99.0<\/td><\/tr><tr><td>178<\/td><td>Profenofos<\/td><td>338.9 &gt; 268.9<\/td><td>18<\/td><td>336.9 &gt; 266.9<\/td><td>14<\/td><td>87.1<\/td><td>93.5<\/td><td>90.0<\/td><td>85.6<\/td><td>107.6<\/td><td>107.6<\/td><td>93.3<\/td><td>91.1<\/td><\/tr><tr><td>179<\/td><td>Profluralin<\/td><td>318.1 &gt; 199.1<\/td><td>16<\/td><td>318.1 &gt; 55.0<\/td><td>22<\/td><td>66.3<\/td><td>64.9<\/td><td>65.7<\/td><td>74.8<\/td><td>105.2<\/td><td>95.9<\/td><td>97.6<\/td><td>91.7<\/td><\/tr><tr><td>180<\/td><td>Propachlor<\/td><td>176.1 &gt; 57.0<\/td><td>8<\/td><td>176.1 &gt; 77.0<\/td><td>24<\/td><td>74.9<\/td><td>76.4<\/td><td>67.3<\/td><td>71.4<\/td><td>114.9<\/td><td>106.5<\/td><td>103.8<\/td><td>102.7<\/td><\/tr><tr><td>181<\/td><td>Propanil<\/td><td>217.0 &gt; 161.0<\/td><td>10<\/td><td>160.9 &gt; 126.0<\/td><td>18<\/td><td>93.5<\/td><td>105.3<\/td><td>91.4<\/td><td>78.7<\/td><td>100.7<\/td><td>106.9<\/td><td>95.8<\/td><td>104.6<\/td><\/tr><tr><td>182<\/td><td>Propargite<\/td><td>173.1 &gt; 135.1<\/td><td>16<\/td><td>173.1 &gt; 107.1<\/td><td>24<\/td><td>88.0<\/td><td>98.7<\/td><td>90.8<\/td><td>85.5<\/td><td>120.0<\/td><td>122.8<\/td><td>74.1<\/td><td>66.1<\/td><\/tr><tr><td>183<\/td><td>Propisochlor<\/td><td>223.1 &gt; 132.1<\/td><td>20<\/td><td>223.1 &gt; 147.1<\/td><td>8<\/td><td>83.7<\/td><td>90.8<\/td><td>79.4<\/td><td>77.9<\/td><td>91.0<\/td><td>100.1<\/td><td>98.4<\/td><td>101.0<\/td><\/tr><tr><td>184<\/td><td>Propyzamide<\/td><td>172.9 &gt; 109.0<\/td><td>26<\/td><td>172.9 &gt; 74.0<\/td><td>28<\/td><td>83.0<\/td><td>91.4<\/td><td>77.1<\/td><td>76.5<\/td><td>98.7<\/td><td>100.0<\/td><td>108.7<\/td><td>106.3<\/td><\/tr><tr><td>185<\/td><td>Prothiofos<\/td><td>266.9 &gt; 238.9<\/td><td>10<\/td><td>309.0 &gt; 238.9<\/td><td>14<\/td><td>74.3<\/td><td>88.9<\/td><td>78.0<\/td><td>73.9<\/td><td>102.4<\/td><td>94.4<\/td><td>102.7<\/td><td>101.2<\/td><\/tr><tr><td>186<\/td><td>Pyraclofos<\/td><td>194.0 &gt; 138.0<\/td><td>22<\/td><td>360.1 &gt; 194.0<\/td><td>14<\/td><td>91.6<\/td><td>111.4<\/td><td>97.0<\/td><td>87.0<\/td><td>84.1<\/td><td>89.9<\/td><td>99.3<\/td><td>100.1<\/td><\/tr><tr><td>187<\/td><td>Pyrazophos<\/td><td>221.1 &gt; 193.1<\/td><td>12<\/td><td>221.1 &gt; 149.1<\/td><td>14<\/td><td>88.7<\/td><td>111.9<\/td><td>97.3<\/td><td>86.1<\/td><td>101.7<\/td><td>96.0<\/td><td>99.9<\/td><td>103.7<\/td><\/tr><tr><td>188<\/td><td>Pyridaben<\/td><td>147.1 &gt; 117.1<\/td><td>22<\/td><td>147.1 &gt; 132.1<\/td><td>14<\/td><td>87.5<\/td><td>106.4<\/td><td>92.5<\/td><td>84.1<\/td><td>99.2<\/td><td>105.1<\/td><td>102.0<\/td><td>102.5<\/td><\/tr><tr><td>189<\/td><td>Pyridaphenthion<\/td><td>340.0 &gt; 199.1<\/td><td>8<\/td><td>199.1 &gt; 92.0<\/td><td>16<\/td><td>100.2<\/td><td>120.0<\/td><td>95.0<\/td><td>89.3<\/td><td>114.1<\/td><td>129.2<\/td><td>109.5<\/td><td>107.5<\/td><\/tr><tr><td>190<\/td><td>Pyrimethanil<\/td><td>198.1 &gt; 118.1<\/td><td>28<\/td><td>198.1 &gt; 158.1<\/td><td>18<\/td><td>74.4<\/td><td>82.5<\/td><td>75.3<\/td><td>73.2<\/td><td>95.2<\/td><td>99.1<\/td><td>96.4<\/td><td>98.5<\/td><\/tr><tr><td>191<\/td><td>Pyriproxyfen<\/td><td>136.1 &gt; 96.0<\/td><td>14<\/td><td>226.1 &gt; 186.1<\/td><td>14<\/td><td>81.3<\/td><td>91.9<\/td><td>92.8<\/td><td>84.4<\/td><td>59.7<\/td><td>78.1<\/td><td>88.1<\/td><td>84.8<\/td><\/tr><tr><td>192<\/td><td>Quinalphos<\/td><td>146.1 &gt; 118.0<\/td><td>10<\/td><td>146.1 &gt; 91.0<\/td><td>24<\/td><td>71.7<\/td><td>86.6<\/td><td>79.6<\/td><td>72.9<\/td><td>204.6<\/td><td>155.7<\/td><td>122.4<\/td><td>117.8<\/td><\/tr><tr><td>193<\/td><td>Quintozene<\/td><td>294.8 &gt; 236.8<\/td><td>16<\/td><td>264.8 &gt; 236.8<\/td><td>10<\/td><td>61.7<\/td><td>0.0<\/td><td>18.5<\/td><td>71.1<\/td><td>100.1<\/td><td>100.7<\/td><td>101.5<\/td><td>100.3<\/td><\/tr><tr><td>194<\/td><td>Resmethrin-1<\/td><td>171.1 &gt; 128.1<\/td><td>12<\/td><td>171.1 &gt; 143.1<\/td><td>6<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><td>N.D.<\/td><\/tr><tr><td>195<\/td><td>Resmethrin-2<\/td><td>171.1 &gt; 143.1<\/td><td>6<\/td><td>171.1 &gt; 128.1<\/td><td>14<\/td><td>85.8<\/td><td>96.4<\/td><td>85.8<\/td><td>78.1<\/td><td>86.0<\/td><td>97.9<\/td><td>95.6<\/td><td>100.0<\/td><\/tr><tr><td>196<\/td><td>Sulfotep<\/td><td>322.0 &gt; 294.0<\/td><td>4<\/td><td>322.0 &gt; 202.0<\/td><td>10<\/td><td>79.1<\/td><td>71.8<\/td><td>65.5<\/td><td>71.8<\/td><td>94.6<\/td><td>98.9<\/td><td>98.0<\/td><td>95.0<\/td><\/tr><tr><td>197<\/td><td>Sulprofos<\/td><td>322.0 &gt; 156.0<\/td><td>8<\/td><td>156.0 &gt; 108.0<\/td><td>28<\/td><td>80.7<\/td><td>97.3<\/td><td>86.0<\/td><td>83.2<\/td><td>101.1<\/td><td>95.9<\/td><td>97.3<\/td><td>95.1<\/td><\/tr><tr><td>198<\/td><td>Tebuconazole<\/td><td>250.1 &gt; 125.1<\/td><td>22<\/td><td>250.1 &gt; 153.1<\/td><td>12<\/td><td>76.8<\/td><td>82.9<\/td><td>68.1<\/td><td>71.6<\/td><td>112.5<\/td><td>96.6<\/td><td>98.9<\/td><td>98.1<\/td><\/tr><tr><td>199<\/td><td>Tebufenpyrad<\/td><td>333.1 &gt; 171.1<\/td><td>20<\/td><td>333.1 &gt; 276.1<\/td><td>8<\/td><td>87.7<\/td><td>105.2<\/td><td>96.7<\/td><td>84.7<\/td><td>97.6<\/td><td>97.3<\/td><td>94.6<\/td><td>95.6<\/td><\/tr><tr><td>200<\/td><td>Tecnazene<\/td><td>260.9 &gt; 202.9<\/td><td>14<\/td><td>202.9 &gt; 85.0<\/td><td>24<\/td><td>78.8<\/td><td>59.9<\/td><td>59.7<\/td><td>72.4<\/td><td>93.9<\/td><td>99.1<\/td><td>96.8<\/td><td>95.8<\/td><\/tr><tr><td>201<\/td><td>Tefluthrin<\/td><td>177.0 &gt; 127.1<\/td><td>16<\/td><td>177.0 &gt; 137.1<\/td><td>16<\/td><td>79.0<\/td><td>81.2<\/td><td>67.5<\/td><td>72.5<\/td><td>92.6<\/td><td>94.9<\/td><td>101.0<\/td><td>98.3<\/td><\/tr><tr><td>202<\/td><td>Terbacil<\/td><td>161.0 &gt; 88.0<\/td><td>20<\/td><td>117.0 &gt; 76.0<\/td><td>8<\/td><td>97.5<\/td><td>111.6<\/td><td>86.5<\/td><td>82.0<\/td><td>81.8<\/td><td>77.9<\/td><td>92.5<\/td><td>96.1<\/td><\/tr><tr><td>203<\/td><td>Terbufos<\/td><td>231.0 &gt; 128.9<\/td><td>26<\/td><td>231.0 &gt; 174.9<\/td><td>14<\/td><td>78.8<\/td><td>80.6<\/td><td>65.2<\/td><td>70.3<\/td><td>111.6<\/td><td>100.1<\/td><td>102.8<\/td><td>104.7<\/td><\/tr><tr><td>204<\/td><td>Terbuthylazine<\/td><td>229.1 &gt; 173.1<\/td><td>6<\/td><td>214.1 &gt; 71.0<\/td><td>16<\/td><td>94.9<\/td><td>91.0<\/td><td>77.6<\/td><td>77.1<\/td><td>82.6<\/td><td>91.6<\/td><td>99.7<\/td><td>103.3<\/td><\/tr><tr><td>205<\/td><td>Tetrachlorvinphos<\/td><td>328.9 &gt; 109.0<\/td><td>20<\/td><td>330.9 &gt; 109.0<\/td><td>22<\/td><td>87.4<\/td><td>102.5<\/td><td>87.3<\/td><td>81.0<\/td><td>96.0<\/td><td>93.6<\/td><td>99.9<\/td><td>96.6<\/td><\/tr><tr><td>206<\/td><td>Tetradifon<\/td><td>355.9 &gt; 159.0<\/td><td>18<\/td><td>355.9 &gt; 228.9<\/td><td>12<\/td><td>84.1<\/td><td>96.6<\/td><td>93.6<\/td><td>88.5<\/td><td>87.9<\/td><td>103.1<\/td><td>102.9<\/td><td>96.7<\/td><\/tr><tr><td>207<\/td><td>Tetramethrin-1<\/td><td>164.1 &gt; 107.1<\/td><td>14<\/td><td>164.1 &gt; 77.0<\/td><td>22<\/td><td>N.D.<\/td><td>N.D.<\/td><td>100.5<\/td><td>94.8<\/td><td>N.D.<\/td><td>N.D.<\/td><td>106.5<\/td><td>114.1<\/td><\/tr><tr><td>208<\/td><td>Tetramethrin-2<\/td><td>164.1 &gt; 107.1<\/td><td>14<\/td><td>164.1 &gt; 77.0<\/td><td>22<\/td><td>103.2<\/td><td>129.6<\/td><td>98.4<\/td><td>88.4<\/td><td>115.2<\/td><td>117.0<\/td><td>107.9<\/td><td>113.8<\/td><\/tr><tr><td>209<\/td><td>THPI<\/td><td>151.1 &gt; 79.0<\/td><td>18<\/td><td>151.1 &gt; 77.0<\/td><td>28<\/td><td>79.4<\/td><td>85.0<\/td><td>81.5<\/td><td>78.2<\/td><td>104.7<\/td><td>104.1<\/td><td>103.6<\/td><td>108.0<\/td><\/tr><tr><td>210<\/td><td>Tolclofos-methyl<\/td><td>264.9 &gt; 93.0<\/td><td>24<\/td><td>264.9 &gt; 219.9<\/td><td>22<\/td><td>72.8<\/td><td>78.6<\/td><td>72.6<\/td><td>73.8<\/td><td>98.8<\/td><td>100.9<\/td><td>102.3<\/td><td>103.6<\/td><\/tr><tr><td>211<\/td><td>Tolylfluanid<\/td><td>238.0 &gt; 137.1<\/td><td>14<\/td><td>181.1 &gt; 138.1<\/td><td>10<\/td><td>66.8<\/td><td>79.8<\/td><td>65.9<\/td><td>64.1<\/td><td>118.7<\/td><td>117.3<\/td><td>114.3<\/td><td>107.4<\/td><\/tr><tr><td>212<\/td><td>Transfluthrin<\/td><td>163.1 &gt; 127.1<\/td><td>6<\/td><td>163.1 &gt; 143.1<\/td><td>16<\/td><td>84.2<\/td><td>85.7<\/td><td>77.1<\/td><td>77.6<\/td><td>106.3<\/td><td>115.0<\/td><td>97.7<\/td><td>99.0<\/td><\/tr><tr><td>213<\/td><td>Triadimefon<\/td><td>208.1 &gt; 111.0<\/td><td>22<\/td><td>208.1 &gt; 127.0<\/td><td>14<\/td><td>88.4<\/td><td>98.2<\/td><td>86.7<\/td><td>80.5<\/td><td>99.5<\/td><td>103.9<\/td><td>97.9<\/td><td>104.7<\/td><\/tr><tr><td>214<\/td><td>Triadimenol<\/td><td>168.1 &gt; 70.0<\/td><td>10<\/td><td>128.1 &gt; 65.0<\/td><td>22<\/td><td>N.D.<\/td><td>N.D.<\/td><td>101.2<\/td><td>94.2<\/td><td>N.D.<\/td><td>N.D.<\/td><td>80.9<\/td><td>85.6<\/td><\/tr><tr><td>215<\/td><td>Tri-allate<\/td><td>268.1 &gt; 184.0<\/td><td>20<\/td><td>270.1 &gt; 186.0<\/td><td>20<\/td><td>80.0<\/td><td>75.6<\/td><td>68.6<\/td><td>74.6<\/td><td>102.4<\/td><td>85.9<\/td><td>94.6<\/td><td>98.1<\/td><\/tr><tr><td>216<\/td><td>Triazophos<\/td><td>257.0 &gt; 162.0<\/td><td>8<\/td><td>257.0 &gt; 134.0<\/td><td>22<\/td><td>89.7<\/td><td>112.4<\/td><td>94.8<\/td><td>86.4<\/td><td>95.9<\/td><td>80.8<\/td><td>90.3<\/td><td>88.2<\/td><\/tr><tr><td>217<\/td><td>Tricyclazole<\/td><td>189.0 &gt; 161.9<\/td><td>12<\/td><td>189.0 &gt; 135.0<\/td><td>18<\/td><td>91.5<\/td><td>95.7<\/td><td>84.5<\/td><td>81.8<\/td><td>105.9<\/td><td>118.7<\/td><td>105.2<\/td><td>97.3<\/td><\/tr><tr><td>218<\/td><td>Triflumizole<\/td><td>278.1 &gt; 73.0<\/td><td>6<\/td><td>206.1 &gt; 186.1<\/td><td>8<\/td><td>87.2<\/td><td>88.2<\/td><td>71.5<\/td><td>76.8<\/td><td>83.2<\/td><td>110.9<\/td><td>97.0<\/td><td>99.2<\/td><\/tr><tr><td>219<\/td><td>Trifluralin<\/td><td>306.1 &gt; 264.1<\/td><td>8<\/td><td>306.1 &gt; 160.1<\/td><td>22<\/td><td>79.9<\/td><td>73.6<\/td><td>64.4<\/td><td>72.5<\/td><td>92.7<\/td><td>100.3<\/td><td>100.8<\/td><td>101.1<\/td><\/tr><tr><td>220<\/td><td>Vinclozolin<\/td><td>285.0 &gt; 212.0<\/td><td>12<\/td><td>212.0 &gt; 172.0<\/td><td>16<\/td><td>86.3<\/td><td>92.8<\/td><td>79.9<\/td><td>80.7<\/td><td>84.3<\/td><td>96.4<\/td><td>104.2<\/td><td>103.3<\/td><\/tr><tr><td>QC-1<\/td><td>1,4-Dichlorobenzene-d4<\/td><td>150.0 &gt; 78.0<\/td><td>24<\/td><td>115.1 &gt; 78.0<\/td><td>12<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>QC-2<\/td><td>Acenaphthene-d10<\/td><td>164.0 &gt; 160.0<\/td><td>30<\/td><td>164.0 &gt; 134.0<\/td><td>38<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>QC-3<\/td><td>Chrysene-d12<\/td><td>240.0 &gt; 236.0<\/td><td>30<\/td><td>240.0 &gt; 212.0<\/td><td>24<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>QC-4<\/td><td>Naphthalene-d8<\/td><td>136.0 &gt; 84.0<\/td><td>22<\/td><td>136.0 &gt; 82.0<\/td><td>28<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>QC-5<\/td><td>Perylene-d12<\/td><td>264.0 &gt; 263.0<\/td><td>34<\/td><td>264.0 &gt; 262.0<\/td><td>24<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>QC-6<\/td><td>Phenanthrene-d10<\/td><td>188.0 &gt; 160.0<\/td><td>24<\/td><td>187.0 &gt; 159.0<\/td><td>18<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-1<\/td><td>2,2&#8242;,5-Trichlorobiphenyl<\/td><td>255.9 &gt; 186.0<\/td><td>26<\/td><td>257.9 &gt; 186.0<\/td><td>26<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-2<\/td><td>2,4,4&#8242;-Trichlorobiphenyl<\/td><td>255.9 &gt; 186.0<\/td><td>26<\/td><td>257.9 &gt; 186.0<\/td><td>26<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-3<\/td><td>2,2&#8242;,5,5&#8242;-Tetrachlorobiphenyl<\/td><td>257.0 &gt; 222.0<\/td><td>12<\/td><td>292.0 &gt; 220.0<\/td><td>26<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-4<\/td><td>Triphenylmethane<\/td><td>244.1 &gt; 167.1<\/td><td>16<\/td><td>244.1 &gt; 165.1<\/td><td>26<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-5<\/td><td>Triphenylphosphate<\/td><td>215.1 &gt; 168.1<\/td><td>16<\/td><td>325.1 &gt; 169.1<\/td><td>20<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><tr><td>IS-6<\/td><td>Tris(1,3-dichloroisopropyl)phosphate<\/td><td>379.0 &gt; 159.0<\/td><td>12<\/td><td>381.0 &gt; 159.0<\/td><td>12<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><td>\u2014<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Die Verbindungen au\u00dferhalb des roten Felds (Abbildung 5) wurden in vier Gruppen unterteilt.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 5:<\/strong>\u00a0Kombinationsdiagramm von Wiederfindung und Ionenverh\u00e4ltnis (Mittel von n = 3 f\u00fcr alle angereicherten Proben) Das rote Feld zeigt den Wiederfindungsbereich zwischen 70\u2013120 % und das Ionenverh\u00e4ltnis innerhalb von \u00b1 30 %.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"630\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-FSAR3080-05-1024x630.jpg\" alt=\"\" class=\"wp-image-20059\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-05-1024x630.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-05-300x185.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-05-768x473.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-05-1536x945.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FSAR3080-05.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">Gruppe A zeigte nur geringe Wiederfindung; diese Gruppe bestand in erster Linie aus Verbindungen mit einem niedrigen Siedepunkt. Sie sind m\u00f6glicherweise bei der Verdampfung verloren gegangen. Gruppe B zeigte hohe relative Ionenverh\u00e4ltnisse, verursacht durch Matrixinterferenzen. Gruppe C zeigte eine hohe Wiederfindung; diese Gruppe bestand aus angereicherten Proben von 10 ng\/g. Einige dieser Verbindungen lagen urspr\u00fcnglich in der Matrix vor und wurden falsch quantifiziert. Bei anderen wurden die hohen Werte durch ihre \u00dcberg\u00e4nge verursacht, die niedrige Response und geringe Stabilit\u00e4t hatten. Gruppe D zeigte ein niedriges relatives Ionenverh\u00e4ltnis. Hier mussten \u00dcberg\u00e4nge mit h\u00f6herer Response festgelegt werden. Durch \u00c4nderung einiger Verfahren und Parameter lassen sich die Positionen dieser Verbindungen m\u00f6glicherweise verbessern.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Schlussfolgerung<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Diese Studie zeigt, dass die modifizierte QuEChERS-Methode in Verbindung mit GC-MS\/MS zur konsistenten \u00dcberwachung von Pestiziden in pflanzlichen Inhaltsstoffen geeignet ist.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Obwohl getrocknete Proben oft mit einer schweren und schwierigen Matrix verbunden sind, lie\u00dfen sich mithilfe der modifizierten QuEChERS-Methode, einer SPE-S\u00e4ulenreinigung und der Verd\u00fcnnung mit Toluol matrixbedingte Interferenzen unterdr\u00fccken. Mittels GC-MS\/MS lie\u00dfen sich selbst bei verd\u00fcnnten Proben \u00e4u\u00dferst kleine Pestizidmengen nachweisen. Die Analysemethode dauert insgesamt nur 30 Minuten und deckt mehr als 200 Pestizide ab. F\u00fcr Laboratorien, die derartige Analysen durchf\u00fchren, ist dies eine L\u00f6sung mit hohem Durchsatz.<\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Literatur<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">[1] M. Anastassiades, S. J. Lehotay, D. \u0160tajnbaher, F. J. Schenck, Fast and Easy Multiresidue Method Employing Acetonitrile Extraction\/Partitioning and \u201cDispersive Solid-Phase Extraction\u201d for the Determination of Pesticide Residues in Produce,&nbsp;<em>J. AOAC Int<\/em>.,&nbsp;<strong>86<\/strong>&nbsp;(2003) 412\u2013431<br>[2] European Commission, Health &amp; Consumer Protection Directorate-General, Guidance document on analytical quality control and validation procedures for pesticide residues analysis in food and feed, SANCO\/12571\/2013<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Erw\u00e4hnte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/32562\">                                Art.-Nr. 32562                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC Multipestizid Standard Kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/32562\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/33267\">                                Art.-Nr. 33267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">QuEChERS Interner Standard Mix f\u00fcr die GC\/MS Analyse, in Acetonitril, 5 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/33267\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31206\">                                Art.-Nr. 31206                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SV Interner Standard Mix, 2000 \u03bcg\/mL, Methylenchlorid, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31206\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25848\">                                Art.-Nr. 25848                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS-Extraktionskit (Original), 4 g MgSO4, 1 g NaCl mit 50 mL-Zentrifugenr\u00f6hrchen, 50 P\u00e4ckchen und 50 R\u00f6hrchen<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/25848\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dietary supplements, which are consumed worldwide, are made from various botanical ingredients. To be safe from pesticides exposure, residual pesticides must be monitored by chromatographic instrumentation. Issues arise, however, due to the fact these botanical samples are dried and cause large interferences in the chromatography. This study shows that the modified QuEChERS method combined with GC-MS\/MS achieves consistent pesticides monitoring in botanical ingredients.<\/p>\n","protected":false},"author":5,"featured_media":6982,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2236,2238],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2329,2324,2328,2363,2368],"ppma_author":[738,754,726,739,594,590,587],"class_list":["post-45294","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-lebensmittel-getranke","industries-application-lebensmittelsicherheit","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-festphasenextraktion-spe","resource-technique-gaschromatographie-gc","resource-technique-massenspektrometrie-ms","resource-technique-ms-ms-de","resource-technique-quechers-de"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"},{"value":2238,"label":"Lebensmittelsicherheit"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2329,"label":"Festphasenextraktion (SPE)"},{"value":2324,"label":"Gaschromatographie (GC)"},{"value":2328,"label":"Massenspektrometrie (MS)"},{"value":2363,"label":"MS\/MS"},{"value":2368,"label":"QuEChERS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSAR3080-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/de\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":787,"category_count":511,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":738,"user_id":0,"is_guest":1,"slug":"riki-kitano","display_name":"Riki Kitano","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Riki","last_name":"Kitano","user_url":"","job_title":"","description":"Shimadzu Scientific Instruments"},{"term_id":754,"user_id":0,"is_guest":1,"slug":"tairo-ogura","display_name":"Tairo Ogura","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Tairo","last_name":"Ogura","user_url":"","job_title":"","description":"Shimadzu Scientific Instruments"},{"term_id":726,"user_id":0,"is_guest":1,"slug":"nicole-lock","display_name":"Nicole Lock","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Nicole","last_name":"Lock","user_url":"","job_title":"","description":"Shimadzu Scientific Instruments"},{"term_id":739,"user_id":0,"is_guest":1,"slug":"robert-clifford","display_name":"Robert Clifford","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Robert","last_name":"Clifford","user_url":"","job_title":"","description":"Shimadzu Scientific Instruments"},{"term_id":594,"user_id":0,"is_guest":1,"slug":"julie-kowalski","display_name":"Julie Kowalski","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Julie","last_name":"Kowalski","user_url":"","job_title":"","description":""},{"term_id":590,"user_id":0,"is_guest":1,"slug":"jack-cochran","display_name":"Jack Cochran","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":587,"user_id":0,"is_guest":1,"slug":"dan-li","display_name":"Dan Li","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Dan","last_name":"Li","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45294","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=45294"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45294\/revisions"}],"predecessor-version":[{"id":85778,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45294\/revisions\/85778"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/6982"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=45294"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=45294"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=45294"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=45294"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=45294"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=45294"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=45294"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=45294"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=45294"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}