{"id":45295,"date":"2023-12-11T00:00:00","date_gmt":"2023-12-11T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/analysieren-sie-metallsensitive-komponenten-ohne-probleme-mit-unseren-neuen-inerten-lc-saulen\/"},"modified":"2026-09-08T18:52:21","modified_gmt":"2026-09-08T18:52:21","slug":"analysieren-sie-metallsensitive-komponenten-ohne-probleme-mit-unseren-neuen-inerten-lc-saulen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/gnss4155-de\/analysieren-sie-metallsensitive-komponenten-ohne-probleme-mit-unseren-neuen-inerten-lc-saulen","title":{"rendered":"Analysieren Sie metallsensitive Komponenten ohne Probleme mit unseren neuen inerten LC S\u00e4ulen"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Unsere neue inerte LC-S\u00e4ulentechnologie hilft Laboren, ihre Analyse von metallempfindlichen Verbindungen zu verbessern. Eine hochwertige inerte Beschichtung, die auf die Edelstahloberfl\u00e4che unserer LC-S\u00e4ulen aufgebracht wird, reduziert die unspezifische Bindung von chelatbildenden Analyten und erm\u00f6glicht so eine empfindliche Analyse und eine vereinfachte Integration der Peaks. In Kombination mit den selektiven station\u00e4ren Phasen von Restek sind diese neuen inerten LC-S\u00e4ulen ideal f\u00fcr die Analyse von metallempfindlichen Verbindungen wie Mykotoxinen und Organophosphat-Pestiziden. &nbsp; &nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die inerten LC-S\u00e4ulen von Restek bieten vier wesentliche Vorteile:&nbsp;<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Verbesserte Peakform<\/strong>&nbsp;ohne Passivierung oder Zus\u00e4tze in der mobilen Phase. &nbsp;&nbsp;<\/li>\n\n\n\n<li><strong>Erh\u00f6hte Response und Wiederfindung<\/strong>, die niedrigere Nachweisgrenzen erm\u00f6glicht. &nbsp;<\/li>\n\n\n\n<li><strong>Hohe Genauigkeit und hoher Durchsatz<\/strong>&nbsp;mit reproduzierbareren Ergebnissen. &nbsp;&nbsp;<\/li>\n\n\n\n<li><strong>Weniger zeitaufw\u00e4ndige Konditionierung<\/strong>&nbsp;und komplizierte Passivierung erforderlich. &nbsp;&nbsp;<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Eine au\u00dfergew\u00f6hnliche Inertheit, bringt au\u00dfergew\u00f6hnliche Ergebnisse&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Es&nbsp;war schon immer eine Herausforderung Verbindungen&nbsp;zu analysieren, die eine unspezifische Adsorption (NSA&nbsp;\u2013 non&nbsp;specific&nbsp;adsorption) oder unspezifische Bindung (NSB&nbsp;\u2013 non-specific&nbsp;binding)&nbsp;mit&nbsp;der&nbsp;Metalloberfl\u00e4che&nbsp;der&nbsp;LC-S\u00e4ulen&nbsp;ausbilden.&nbsp;Meist erkennt man an&nbsp;schlechter&nbsp;Peakform&nbsp;und -empfindlichkeit,&nbsp;dass polare, in der Regel saure Verbindungen mit den Metalloberfl\u00e4chen der S\u00e4ule interagieren, was die unsch\u00f6nen&nbsp;Ergebnisse&nbsp;verursacht. Unsere hochwertige inerte S\u00e4ulentechnologie&nbsp;wurde entwickelt, um NSA und NSB an die S\u00e4ulenhardware zu&nbsp;verhindern. So&nbsp;k\u00f6nnen&nbsp;Sie&nbsp;bei der Arbeit mit metallempfindlichen Analyten mehr Vertrauen in ihre Daten haben.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pestizide<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pestizid-Panels profitieren von der Verwendung inerter LC-S\u00e4ulen, da sie&nbsp;die verschiedensten&nbsp;Verbindungen enthalten. Phosphorylierte, saure, polare Verbindungen und\/oder&nbsp;metallchelatbildende&nbsp;Komponenten, wie Organophosphat-Pestizide, reagieren mit den Metalloberfl\u00e4chen im Inneren der analytischen S\u00e4ule. Unsere neuen inerten LC-S\u00e4ulen l\u00f6sen dieses Problem auf einfache Weise und verbessern das Gesamtergebnis Ihrer Pestizid-Analytik&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 1:<\/strong>\u00a0Unsere neuen inerten Raptor ARC-18-S\u00e4ulen bieten eine h\u00f6here Empfindlichkeit,\u00a0bessere\u00a0Wiederfindungsraten und niedrigere Nachweisgrenzen ohne\u00a0Konditionierung\u00a0der S\u00e4ule.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0596.png\" alt=\"Pesticides on Raptor Inert ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0596<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><th style=\"text-align: center;width: 75px\">Peak Area<\/th><th style=\"text-align: center;width: 75px\">Peak Height<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamidophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10265-92-6\/Methamidophos\" target=\"_blank\" rel=\"noopener\">Methamidophos<\/a><\/td><td class=\"oth\">1.33<\/td><td class=\"oth\">142.0<\/td><td class=\"oth\">94.0<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">428941<\/td><td class=\"oth\">105189<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acephate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30560-19-1\/Acephate\" target=\"_blank\" rel=\"noopener\">Acephate<\/a><\/td><td class=\"oth\">1.55<\/td><td class=\"oth\">184.0<\/td><td class=\"oth\">143.0<\/td><td class=\"oth\">48.9<\/td><td class=\"oth\">300642<\/td><td class=\"oth\">104729<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Omethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1113-02-6\/Omethoate\" target=\"_blank\" rel=\"noopener\">Omethoate<\/a><\/td><td class=\"oth\">1.72<\/td><td class=\"oth\">214.0<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">182.9<\/td><td class=\"oth\">892008<\/td><td class=\"oth\">337690<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Monocrotophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6923-22-4\/Monocrotophos\" target=\"_blank\" rel=\"noopener\">Monocrotophos<\/a><\/td><td class=\"oth\">2.21<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">215810<\/td><td class=\"oth\">78425<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicrotophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/141-66-2\/Dicrotophos\" target=\"_blank\" rel=\"noopener\">Dicrotophos<\/a><\/td><td class=\"oth\">2.35<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">112.1<\/td><td class=\"oth\">72.0<\/td><td class=\"oth\">404916<\/td><td class=\"oth\">159292<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">2.52<\/td><td class=\"oth\">230.0<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">199.0<\/td><td class=\"oth\">807805<\/td><td class=\"oth\">342939<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trichlorfon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-68-6\/Trichlorfon\" target=\"_blank\" rel=\"noopener\">Trichlorfon<\/a><\/td><td class=\"oth\">2.53<\/td><td class=\"oth\">257.0<\/td><td class=\"oth\">108.9<\/td><td class=\"oth\">220.8<\/td><td class=\"oth\">173942<\/td><td class=\"oth\">63266<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vamidothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2275-23-2\/Vamidothion\" target=\"_blank\" rel=\"noopener\">Vamidothion<\/a><\/td><td class=\"oth\">2.54<\/td><td class=\"oth\">288.0<\/td><td class=\"oth\">146.0<\/td><td class=\"oth\">118.0<\/td><td class=\"oth\">1333829<\/td><td class=\"oth\">547308<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\">Mevinphos isomer 1<\/td><td class=\"oth\">2.55<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">126.9<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">311274<\/td><td class=\"oth\">129961<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\">Mevinphos isomer 2<\/td><td class=\"oth\">2.76<\/td><td class=\"oth\">241.9<\/td><td class=\"oth\">126.9<\/td><td class=\"oth\">192.9<\/td><td class=\"oth\">74030<\/td><td class=\"oth\">29802<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-25-2\/Carbaryl\" target=\"_blank\" rel=\"noopener\">Carbaryl<\/a><\/td><td class=\"oth\">3.18<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">145.0<\/td><td class=\"oth\">127.0<\/td><td class=\"oth\">39671<\/td><td class=\"oth\">11924<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isocarbophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24353-61-5\/Isocarbophos\" target=\"_blank\" rel=\"noopener\">Isocarbophos<\/a><\/td><td class=\"oth\">3.52<\/td><td class=\"oth\">291.1<\/td><td class=\"oth\">231.1<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">33294<\/td><td class=\"oth\">11941<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\">Dimethomorph isomer 1<\/td><td class=\"oth\">3.96<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">300.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">511766<\/td><td class=\"oth\">172977<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\">Dimethomorph isomer 2<\/td><td class=\"oth\">4.13<\/td><td class=\"oth\">388.2<\/td><td class=\"oth\">300.9<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">877031<\/td><td class=\"oth\">328826<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Temephos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3383-96-8\/Temephos\" target=\"_blank\" rel=\"noopener\">Temephos<\/a><\/td><td class=\"oth\">5.70<\/td><td class=\"oth\">467.1<\/td><td class=\"oth\">124.9<\/td><td class=\"oth\">418.9<\/td><td class=\"oth\">164310<\/td><td class=\"oth\">64751<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Inert ARC-18   (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9314A12-T\" rel=\"noopener\">cat.# 9314A12-T<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>50 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>LC multiresidue pesticide standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31972\" rel=\"noopener\">cat.# 31972<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water, 0.1% formic acid<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 2 mM ammonium formate, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>2.00<\/td><td>0.4<\/td><td>40<\/td><td>60<\/td><\/tr><tr><td>4.00<\/td><td>0.4<\/td><td>25<\/td><td>75<\/td><\/tr><tr><td>6.00<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>7.50<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>7.51<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>95<\/td><td>5<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu LCMS-8060<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12-T<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0596.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 2:<\/strong>\u00a0Verglichen mit\u00a0herk\u00f6mmlichen\u00a0S\u00e4ulen aus Edelstahl, bietet unsere neue inerte Raptor\u00a0ARC-18 S\u00e4ule au\u00dfergew\u00f6hnliche\u00a0Wiederfindungen.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0591.png\" alt=\"Comparison of Pesticides on Raptor Inert ARC-18 and Raptor ARC-18\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0591<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0591.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 3:<\/strong>\u00a0Peakfl\u00e4che und\u00a0Peakh\u00f6he\u00a0sind deutlich erh\u00f6ht f\u00fcr die Pestizidanalytik.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0593.png\" alt=\"Comparison of Pesticides on Raptor Inert ARC-18 and Raptor ARC-18 - Overlay View\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0593<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31972<\/li><li>9314A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0593.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Tabelle I:<\/strong>&nbsp;Die neuen inerten S\u00e4ulen von Restek zeigen bei dieser Analyse von Pestiziden eine bis zu 2-fach gr\u00f6\u00dfere Peakfl\u00e4che und&nbsp;-h\u00f6he gegen\u00fcber Edelstahls\u00e4ulen.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Komponente<\/strong><\/td><td colspan=\"3\"><strong>Peakfl\u00e4che<\/strong><\/td><td colspan=\"3\"><strong>Peakh\u00f6he<\/strong><\/td><\/tr><tr><td><strong>Edelstahl<\/strong><\/td><td><strong>Inert<\/strong><\/td><td><strong>Verh\u00e4ltnis der Peakfl\u00e4chen&nbsp;(Inert\/Edelstahl)<\/strong><\/td><td><strong>Edelstahl<\/strong><\/td><td><strong>Inert<\/strong><\/td><td><strong>Verh\u00e4ltnis der&nbsp;Peakh\u00f6hen&nbsp;(Inert\/Edelstahl)<\/strong><\/td><\/tr><tr><td>Methamidophos<\/td><td>254969<\/td><td>428941<\/td><td><strong>1.68<\/strong><\/td><td>52553<\/td><td>105189<\/td><td><strong>2.00<\/strong><\/td><\/tr><tr><td>Acephate<\/td><td>168776<\/td><td>300642<\/td><td><strong>1.78<\/strong><\/td><td>58418<\/td><td>104729<\/td><td><strong>1.79<\/strong><\/td><\/tr><tr><td>Omethoate<\/td><td>579502<\/td><td>892008<\/td><td><strong>1.54<\/strong><\/td><td>216157<\/td><td>337690<\/td><td><strong>1.56<\/strong><\/td><\/tr><tr><td>Monocrotophos<\/td><td>140095<\/td><td>215810<\/td><td><strong>1.54<\/strong><\/td><td>51402<\/td><td>78425<\/td><td><strong>1.53<\/strong><\/td><\/tr><tr><td>Dicrotophos<\/td><td>340978<\/td><td>404916<\/td><td><strong>1.19<\/strong><\/td><td>135380<\/td><td>159292<\/td><td><strong>1.18<\/strong><\/td><\/tr><tr><td>Dimethoate<\/td><td>461156<\/td><td>807805<\/td><td><strong>1.75<\/strong><\/td><td>188746<\/td><td>342939<\/td><td><strong>1.82<\/strong><\/td><\/tr><tr><td>Trichlorfon<\/td><td>84233<\/td><td>173942<\/td><td><strong>2.07<\/strong><\/td><td>34793<\/td><td>63266<\/td><td><strong>1.82<\/strong><\/td><\/tr><tr><td>Vamidothion<\/td><td>913264<\/td><td>1333829<\/td><td><strong>1.46<\/strong><\/td><td>354311<\/td><td>547308<\/td><td><strong>1.54<\/strong><\/td><\/tr><tr><td>Mevinphos isomer 1<\/td><td>213632<\/td><td>311274<\/td><td><strong>1.46<\/strong><\/td><td>82105<\/td><td>129961<\/td><td><strong>1.58<\/strong><\/td><\/tr><tr><td>Mevinphos isomer 2<\/td><td>56093<\/td><td>74030<\/td><td><strong>&nbsp;1.32<\/strong><\/td><td>29070<\/td><td>29802<\/td><td><strong>1.03&nbsp;<\/strong><\/td><\/tr><tr><td>Carbaryl<\/td><td>43590<\/td><td>39671<\/td><td><strong>0.91<\/strong><\/td><td>14563<\/td><td>11924<\/td><td><strong>0.82<\/strong><\/td><\/tr><tr><td>Isocarbophos<\/td><td>21587<\/td><td>33294<\/td><td><strong>1.54<\/strong><\/td><td>9062<\/td><td>11941<\/td><td><strong>1.32<\/strong><\/td><\/tr><tr><td>Dimethomorph isomer 1<\/td><td>462425<\/td><td>511766<\/td><td><strong>1.11<\/strong><\/td><td>166990<\/td><td>172977<\/td><td><strong>1.04<\/strong><\/td><\/tr><tr><td>Dimethomorph isomer 2<\/td><td>896109<\/td><td>877031<\/td><td><strong>0.98&nbsp;<\/strong><\/td><td>311657<\/td><td>328826<\/td><td><strong>1.06&nbsp;<\/strong><\/td><\/tr><tr><td>Temephos<\/td><td>98793<\/td><td>164310<\/td><td><strong>1.66<\/strong><\/td><td>35383<\/td><td>64751<\/td><td><strong>1.83<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Mykotoxine<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die Analyse von Mykotoxinen kann schwierig sein und erfordert oft eine umfangreiche S\u00e4ulenkonditionierung und&nbsp;\u00c4quilibrierung, um akzeptable&nbsp;Peakformen&nbsp;zu erhalten. Dies&nbsp;l\u00e4sst sich&nbsp;auf die reaktive Natur der Verbindungen zur\u00fcckf\u00fchren, die saure, polare oder anderweitig&nbsp;metallchelatbildende&nbsp;Gruppen enthalten.&nbsp;In Kombination mit unseren station\u00e4ren Phasen, kann unsere&nbsp;inerte S\u00e4ulenhardware&nbsp;ihre&nbsp;Methoden vereinfachen und die&nbsp;Response&nbsp;und&nbsp;Peakform&nbsp;dieser Verbindungen verbessern.&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 4:<\/strong>\u00a0Erzielen Sie bei der Analyse von Mykotoxinen mit unseren neuen inerten Raptor-Biphenyls\u00e4ulen\u00a0eine hervorragende\u00a0Peakform\u00a0ohne zus\u00e4tzliche Passivierung der S\u00e4ule oder Zus\u00e4tze\u00a0zu den mobilen Phasen.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0552.png\" alt=\"Multi-Mycotoxin Analysis on Raptor Inert Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0552<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion <\/th><th style=\"text-align: center;width: 75px\">Peak Area<\/th><th style=\"text-align: center;width: 75px\">Peak Height<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nivalenol \" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23282-20-4\/Nivalenol \" target=\"_blank\" rel=\"noopener\">Nivalenol <\/a><\/td><td class=\"oth\">0.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">295.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">4182<\/td><td class=\"oth\">64495<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51481-10-8\/Deoxynivalenol\" target=\"_blank\" rel=\"noopener\">Deoxynivalenol<\/a><\/td><td class=\"oth\">1.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">297.2<\/td><td class=\"oth\">231.0<\/td><td class=\"oth\">17346<\/td><td class=\"oth\">281906<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fusarenon-X\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23255-69-8\/Fusarenon-X\" target=\"_blank\" rel=\"noopener\">Fusarenon-X<\/a><\/td><td class=\"oth\">1.92<\/td><td class=\"oth\">10<\/td><td class=\"oth\">355.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">7668<\/td><td class=\"oth\">121790<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 15-Acetyldeoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88337-96-6\/15-Acetyldeoxynivalenol\" target=\"_blank\" rel=\"noopener\">15-Acetyldeoxynivalenol<\/a><\/td><td class=\"oth\">3.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">339.2<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">31369<\/td><td class=\"oth\">517570<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Acetyldeoxynivalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50722-38-8\/3-Acetyldeoxynivalenol\" target=\"_blank\" rel=\"noopener\">3-Acetyldeoxynivalenol<\/a><\/td><td class=\"oth\">3.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">339.2<\/td><td class=\"oth\">213.1<\/td><td class=\"oth\">22613<\/td><td class=\"oth\">296396<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tenuazonic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/610-88-8\/Tenuazonic acid\" target=\"_blank\" rel=\"noopener\">Tenuazonic acid<\/a><\/td><td class=\"oth\">4.11<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">125.0<\/td><td class=\"oth\">47828<\/td><td class=\"oth\">197658<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Altenuene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29752-43-0\/Altenuene\" target=\"_blank\" rel=\"noopener\">Altenuene<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">10<\/td><td class=\"oth\">293.2<\/td><td class=\"oth\">257.1<\/td><td class=\"oth\">113850<\/td><td class=\"oth\">2059699<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alternariol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/641-38-3\/Alternariol\" target=\"_blank\" rel=\"noopener\">Alternariol<\/a><\/td><td class=\"oth\">5.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">259.0<\/td><td class=\"oth\">185.1<\/td><td class=\"oth\">73272<\/td><td class=\"oth\">1302192<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergosine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/561-94-4\/Ergosine\" target=\"_blank\" rel=\"noopener\">Ergosine<\/a><\/td><td class=\"oth\">5.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">548.4<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">486620<\/td><td class=\"oth\">9366601<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Citrinin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/518-75-2\/Citrinin\" target=\"_blank\" rel=\"noopener\">Citrinin<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">251.2<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">1007880<\/td><td class=\"oth\">9828889<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergosinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/596-88-3\/Ergosinine\" target=\"_blank\" rel=\"noopener\">Ergosinine<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">548.4<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">496734<\/td><td class=\"oth\">8740527<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-83-0\/Fumonisin B1\" target=\"_blank\" rel=\"noopener\">Fumonisin B1<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">10<\/td><td class=\"oth\">722.5<\/td><td class=\"oth\">352.3<\/td><td class=\"oth\">122878<\/td><td class=\"oth\">2415567<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diacetoxyscirpenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2270-40-8\/Diacetoxyscirpenol\" target=\"_blank\" rel=\"noopener\">Diacetoxyscirpenol<\/a><\/td><td class=\"oth\">5.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">384.2<\/td><td class=\"oth\">247.1<\/td><td class=\"oth\">68139<\/td><td class=\"oth\">1208825<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergotamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-15-5\/Ergotamine\" target=\"_blank\" rel=\"noopener\">Ergotamine<\/a><\/td><td class=\"oth\">5.71<\/td><td class=\"oth\">10<\/td><td class=\"oth\">582.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">493003<\/td><td class=\"oth\">9274155<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocornine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/564-36-3\/Ergocornine\" target=\"_blank\" rel=\"noopener\">Ergocornine<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">562.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">387025<\/td><td class=\"oth\">7732744<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergotaminine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/639-81-6\/Ergotaminine\" target=\"_blank\" rel=\"noopener\">Ergotaminine<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">10<\/td><td class=\"oth\">582.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">462119<\/td><td class=\"oth\">9237991<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for HT-2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26934-87-2\/HT-2\" target=\"_blank\" rel=\"noopener\">HT-2<\/a><\/td><td class=\"oth\">6.13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">447.2<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">15221<\/td><td class=\"oth\">323765<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocryptine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-09-1\/Ergocryptine\" target=\"_blank\" rel=\"noopener\">Ergocryptine<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">10<\/td><td class=\"oth\">576.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">522204<\/td><td class=\"oth\">11360838<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1422359-85-0\/Fumonisin B3\" target=\"_blank\" rel=\"noopener\">Fumonisin B3<\/a><\/td><td class=\"oth\">6.23<\/td><td class=\"oth\">10<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><td class=\"oth\">143302<\/td><td class=\"oth\">3444421<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocristine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-08-0\/Ergocristine\" target=\"_blank\" rel=\"noopener\">Ergocristine<\/a><\/td><td class=\"oth\">6.44<\/td><td class=\"oth\">10<\/td><td class=\"oth\">610.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">195562<\/td><td class=\"oth\">4450058<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-84-1\/Fumonisin B2\" target=\"_blank\" rel=\"noopener\">Fumonisin B2<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><td class=\"oth\">151719<\/td><td class=\"oth\">3869822<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tentoxin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28540-82-1\/Tentoxin\" target=\"_blank\" rel=\"noopener\">Tentoxin<\/a><\/td><td class=\"oth\">6.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">415.2<\/td><td class=\"oth\">312.2<\/td><td class=\"oth\">95175<\/td><td class=\"oth\">2131906<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Zearalenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36455-72-8\/\u03b1-Zearalenol\" target=\"_blank\" rel=\"noopener\">\u03b1-Zearalenol<\/a><\/td><td class=\"oth\">6.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">303.1<\/td><td class=\"oth\">285.1<\/td><td class=\"oth\">30224<\/td><td class=\"oth\">702420<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocorninine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/564-37-4\/Ergocorninine\" target=\"_blank\" rel=\"noopener\">Ergocorninine<\/a><\/td><td class=\"oth\">6.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">562.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">704029<\/td><td class=\"oth\">14389283<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7241-98-7\/Aflatoxin G2\" target=\"_blank\" rel=\"noopener\">Aflatoxin G2<\/a><\/td><td class=\"oth\">6.97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">331.2<\/td><td class=\"oth\">189.0<\/td><td class=\"oth\">262824<\/td><td class=\"oth\">5274353<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for T-2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-31-7\/T-2\" target=\"_blank\" rel=\"noopener\">T-2<\/a><\/td><td class=\"oth\">7.09<\/td><td class=\"oth\">10<\/td><td class=\"oth\">489.2<\/td><td class=\"oth\">387.1<\/td><td class=\"oth\">56535<\/td><td class=\"oth\">1394735<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocryptinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-10-4\/Ergocryptinine\" target=\"_blank\" rel=\"noopener\">Ergocryptinine<\/a><\/td><td class=\"oth\">7.18<\/td><td class=\"oth\">10<\/td><td class=\"oth\">576.4<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">778972<\/td><td class=\"oth\">16765348<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ergocristinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/511-07-9\/Ergocristinine\" target=\"_blank\" rel=\"noopener\">Ergocristinine<\/a><\/td><td class=\"oth\">7.40<\/td><td class=\"oth\">10<\/td><td class=\"oth\">610.4<\/td><td class=\"oth\">223.2<\/td><td class=\"oth\">1583053<\/td><td class=\"oth\">32975663<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin G1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1165-39-5\/Aflatoxin G1\" target=\"_blank\" rel=\"noopener\">Aflatoxin G1<\/a><\/td><td class=\"oth\">7.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">329.1<\/td><td class=\"oth\">199.7<\/td><td class=\"oth\">304389<\/td><td class=\"oth\">6102959<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zearalenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17924-92-4\/Zearalenone\" target=\"_blank\" rel=\"noopener\">Zearalenone<\/a><\/td><td class=\"oth\">7.59<\/td><td class=\"oth\">10<\/td><td class=\"oth\">319.2<\/td><td class=\"oth\">283.1<\/td><td class=\"oth\">37162<\/td><td class=\"oth\">927455<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alternariol monomethylether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26894-49-5\/Alternariol monomethylether\" target=\"_blank\" rel=\"noopener\">Alternariol monomethylether<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">273.0<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">31024<\/td><td class=\"oth\">640689<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7220-81-7\/Aflatoxin B2\" target=\"_blank\" rel=\"noopener\">Aflatoxin B2<\/a><\/td><td class=\"oth\">7.63<\/td><td class=\"oth\">10<\/td><td class=\"oth\">315.1<\/td><td class=\"oth\">287.0<\/td><td class=\"oth\">295648<\/td><td class=\"oth\">5724754<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aflatoxin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1162-65-8\/Aflatoxin B1\" target=\"_blank\" rel=\"noopener\">Aflatoxin B1<\/a><\/td><td class=\"oth\">8.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">313.2<\/td><td class=\"oth\">241.1<\/td><td class=\"oth\">223520<\/td><td class=\"oth\">4425821<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ochratoxin A\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-47-9\/Ochratoxin A\" target=\"_blank\" rel=\"noopener\">Ochratoxin A<\/a><\/td><td class=\"oth\">8.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">404.1<\/td><td class=\"oth\">239.0<\/td><td class=\"oth\">190060<\/td><td class=\"oth\">4411953<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor Inert Biphenyl  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\" rel=\"noopener\">cat.# 9309A12-T<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>60 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Aflatoxins standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34121\" rel=\"noopener\">cat.# 34121<\/a>)<\/td><\/tr><tr><td><\/td><td>Ochratoxin A standard (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34122\" rel=\"noopener\">cat.# 34122<\/a>)<\/td><\/tr><tr><td><\/td><\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.05% formic acid  <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.05% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>5.00<\/td><td>0.4<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>9.01<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>11.0<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>440 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY UPLC I-Class<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><br \/><br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34121<\/li><li>34122<\/li><li>9309A12-T<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>mycotoxin<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0552.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 5:<\/strong>\u00a0Bei dieser Analyse von\u00a0Fumonisinen\u00a0erreichen unsere neuen inerten Raptor-Biphenyls\u00e4ulen\u00a0deutlich\u00a0gr\u00f6\u00dfere\u00a0Peakfl\u00e4chen\u00a0im Vergleich zu herk\u00f6mmlichen Edelstahls\u00e4ulen.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0554.png\" alt=\"Comparison of Fumonisin B Compounds on Raptor Inert Biphenyl and Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0554<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0554.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 6:<\/strong>\u00a0Peakfl\u00e4che und\u00a0Peakh\u00f6he\u00a0sind bei der Analyse von\u00a0Fumonisinen\u00a0signifikant h\u00f6her.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0556.png\" alt=\"Comparison of Fumonisin B Compounds on Raptor Inert Biphenyl and Raptor Biphenyl\u2014Overlay View\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0556<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Raptor Inert Biphenyl t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Raptor Biphenyl t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion <\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-83-0\/Fumonisin B1\" target=\"_blank\" rel=\"noopener\">Fumonisin B1<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">722.5<\/td><td class=\"oth\">352.3<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B3\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1422359-85-0\/Fumonisin B3\" target=\"_blank\" rel=\"noopener\">Fumonisin B3<\/a><\/td><td class=\"oth\">6.23<\/td><td class=\"oth\">6.23<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fumonisin B2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116355-84-1\/Fumonisin B2\" target=\"_blank\" rel=\"noopener\">Fumonisin B2<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">6.60<\/td><td class=\"oth\">706.4<\/td><td class=\"oth\">336.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes.<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>60 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>50:50 Water:methanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>10 ng\/mL<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.05% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.05% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>5.00<\/td><td>0.4<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>9.00<\/td><td>0.4<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>9.01<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><tr><td>11.0<\/td><td>0.4<\/td><td>75<\/td><td>25<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>440 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Waters Xevo TQ-S<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Waters ACQUITY UPLC I-Class<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Y-axes are shown at the same scale.<br \/>Columns are:<br \/>\u2022 Raptor Inert Biphenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12-T\" rel=\"noopener\">cat.# 9309A12-T<\/a>)<br \/>\u2022 Raptor Biphenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9309A12\" rel=\"noopener\">cat.# 9309A12<\/a>)<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A12<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0556.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Tabelle II:<\/strong>&nbsp;Bei dieser Analyse von Mykotoxinen k\u00f6nnen unsere neuen inerten S\u00e4ulen eine bis zu 10-fache Steigerung der&nbsp;Peakh\u00f6he&nbsp;gegen\u00fcber&nbsp;Edelstahl-S\u00e4ulen erzielen.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>Komponente<\/strong><\/td><td colspan=\"3\"><strong>Peakfl\u00e4che<\/strong><\/td><td colspan=\"3\"><strong>Peakh\u00f6he<\/strong><\/td><\/tr><tr><td><strong>Edelstahl<\/strong><\/td><td><strong>Inert<\/strong><\/td><td><strong>Verh\u00e4ltnis der Peakfl\u00e4chen&nbsp;(Inert\/Edelstahl)<\/strong><\/td><td><strong>Edelstahl<\/strong><\/td><td><strong>Inert<\/strong><\/td><td><strong>Verh\u00e4ltnis der&nbsp;Peakh\u00f6hen&nbsp;(Inert\/Edelstahl)<\/strong><\/td><\/tr><tr><td>Fumonisin B1<\/td><td>32578<\/td><td>122878<\/td><td><strong>3.77<\/strong><\/td><td>399544<\/td><td>2415567<\/td><td><strong>6.05<\/strong><\/td><\/tr><tr><td>Fumonisin B2<\/td><td>23427<\/td><td>151719<\/td><td><strong>6.48<\/strong><\/td><td>383130<\/td><td>3869822<\/td><td><strong>10.10<\/strong><\/td><\/tr><tr><td>Fumonisin B3<\/td><td>29864<\/td><td>143302<\/td><td><strong>4.80<\/strong><\/td><td>472279<\/td><td>3444421<\/td><td><strong>7.29<\/strong><\/td><\/tr><tr><td>Ergocristine<\/td><td>171197<\/td><td>195562<\/td><td><strong>1.14<\/strong><\/td><td>3865898<\/td><td>4450058<\/td><td><strong>1.15<\/strong><\/td><\/tr><tr><td>Ergocristinine<\/td><td>1393116<\/td><td>1583053<\/td><td><strong>1.14<\/strong><\/td><td>29212317<\/td><td>32975663<\/td><td><strong>1.13<\/strong><\/td><\/tr><tr><td>Ergotamine<\/td><td>433635<\/td><td>493003<\/td><td><strong>1.14<\/strong><\/td><td>8149518<\/td><td>9274156<\/td><td><strong>1.14<\/strong><\/td><\/tr><tr><td>Ergotaminine<\/td><td>397370<\/td><td>462119<\/td><td><strong>1.16<\/strong><\/td><td>7885403<\/td><td>9237991<\/td><td><strong>1.17<\/strong><\/td><\/tr><tr><td>Ergocryptine<\/td><td>446481<\/td><td>522204<\/td><td><strong>1.17<\/strong><\/td><td>9671753<\/td><td>11360839<\/td><td><strong>1.17<\/strong><\/td><\/tr><tr><td>Ergocryptinine<\/td><td>658788<\/td><td>778972<\/td><td><strong>1.18<\/strong><\/td><td>13680420<\/td><td>16765348<\/td><td><strong>1.23<\/strong><\/td><\/tr><tr><td>Ergocornine<\/td><td>370509<\/td><td>387025<\/td><td><strong>1.04<\/strong><\/td><td>7248981<\/td><td>7732744<\/td><td><strong>1.07<\/strong><\/td><\/tr><tr><td>Ergocorninine<\/td><td>590167<\/td><td>704029<\/td><td><strong>1.19<\/strong><\/td><td>12052359<\/td><td>14389283<\/td><td><strong>1.19<\/strong><\/td><\/tr><tr><td>Ergosine<\/td><td>445243<\/td><td>486620<\/td><td><strong>1.09<\/strong><\/td><td>8630932<\/td><td>9366602<\/td><td><strong>1.09<\/strong><\/td><\/tr><tr><td>Ergosinine<\/td><td>439026<\/td><td>496734<\/td><td><strong>1.13<\/strong><\/td><td>7820785<\/td><td>8740527<\/td><td><strong>1.12<\/strong><\/td><\/tr><tr><td>T-2<\/td><td>43286<\/td><td>56535<\/td><td><strong>1.31<\/strong><\/td><td>1046233<\/td><td>1394735<\/td><td><strong>1.33<\/strong><\/td><\/tr><tr><td>HT-2<\/td><td>10183<\/td><td>15221<\/td><td><strong>1.49<\/strong><\/td><td>216703<\/td><td>323765<\/td><td><strong>1.49<\/strong><\/td><\/tr><tr><td>Tentoxin<\/td><td>70973<\/td><td>95175<\/td><td><strong>1.34<\/strong><\/td><td>1577164<\/td><td>2131907<\/td><td><strong>1.35<\/strong><\/td><\/tr><tr><td>Ochratoxin<\/td><td>173686<\/td><td>190060<\/td><td><strong>1.09<\/strong><\/td><td>4039682<\/td><td>4411953<\/td><td><strong>1.09<\/strong><\/td><\/tr><tr><td>Diacetoxyscirpenol<\/td><td>47850<\/td><td>68139<\/td><td><strong>1.42<\/strong><\/td><td>846403<\/td><td>1208826<\/td><td><strong>1.43<\/strong><\/td><\/tr><tr><td>Fusarenone X<\/td><td>3865<\/td><td>7668<\/td><td><strong>1.98<\/strong><\/td><td>60409<\/td><td>121790<\/td><td><strong>2.02<\/strong><\/td><\/tr><tr><td>15-acetyl-DON<\/td><td>17055<\/td><td>31369<\/td><td><strong>1.84<\/strong><\/td><td>269862<\/td><td>517570<\/td><td><strong>1.92<\/strong><\/td><\/tr><tr><td>3-acetyldeoxyvinalenol<\/td><td>13353<\/td><td>22613<\/td><td><strong>1.69<\/strong><\/td><td>179204<\/td><td>296396<\/td><td><strong>1.65<\/strong><\/td><\/tr><tr><td>Aflatoxin G2<\/td><td>171597<\/td><td>262824<\/td><td><strong>1.53<\/strong><\/td><td>3429501<\/td><td>5274354<\/td><td><strong>1.54<\/strong><\/td><\/tr><tr><td>Aflatoxin G1<\/td><td>224058<\/td><td>304389<\/td><td><strong>1.36<\/strong><\/td><td>4607959<\/td><td>6102959<\/td><td><strong>1.32<\/strong><\/td><\/tr><tr><td>Ergometrine<\/td><td>301459<\/td><td>558555<\/td><td><strong>1.85<\/strong><\/td><td>2255203<\/td><td>4659031<\/td><td><strong>2.07<\/strong><\/td><\/tr><tr><td>Ergometrinine<\/td><td>217271<\/td><td>396109<\/td><td><strong>1.82<\/strong><\/td><td>1814997<\/td><td>4031002<\/td><td><strong>2.22<\/strong><\/td><\/tr><tr><td>ZON<\/td><td>25617<\/td><td>37162<\/td><td><strong>1.45<\/strong><\/td><td>656915<\/td><td>927455<\/td><td><strong>1.41<\/strong><\/td><\/tr><tr><td>Aflatoxin B2<\/td><td>159389<\/td><td>295648<\/td><td><strong>1.85<\/strong><\/td><td>3462489<\/td><td>5724754<\/td><td><strong>1.65<\/strong><\/td><\/tr><tr><td>Aflatoxin B1<\/td><td>265935<\/td><td>223520<\/td><td><strong>0.84<\/strong><\/td><td>5335576<\/td><td>4425821<\/td><td><strong>0.83<\/strong><\/td><\/tr><tr><td>Alpha-zearalenol<\/td><td>16202<\/td><td>30224<\/td><td><strong>1.87<\/strong><\/td><td>382092<\/td><td>702420<\/td><td><strong>1.84<\/strong><\/td><\/tr><tr><td>Deoxynivalenol<\/td><td>6935<\/td><td>17346<\/td><td><strong>2.50<\/strong><\/td><td>117927<\/td><td>281906<\/td><td><strong>2.39<\/strong><\/td><\/tr><tr><td>Nivalenol<\/td><td>1790<\/td><td>4182<\/td><td><strong>2.34<\/strong><\/td><td>25276<\/td><td>64495<\/td><td><strong>2.55<\/strong><\/td><\/tr><tr><td>Altenuene<\/td><td>63224<\/td><td>113850<\/td><td><strong>1.80<\/strong><\/td><td>1187958<\/td><td>2059700<\/td><td><strong>1.73<\/strong><\/td><\/tr><tr><td>Alternariol monomethyl ether<\/td><td>19537<\/td><td>31024<\/td><td><strong>1.59<\/strong><\/td><td>428922<\/td><td>640689<\/td><td><strong>1.49<\/strong><\/td><\/tr><tr><td>Alternariol<\/td><td>48204<\/td><td>73272<\/td><td><strong>1.52<\/strong><\/td><td>837410<\/td><td>1302192<\/td><td><strong>1.56<\/strong><\/td><\/tr><tr><td>Citrinin<\/td><td>499900<\/td><td>1007880<\/td><td><strong>2.02<\/strong><\/td><td>5031182<\/td><td>9828890<\/td><td><strong>1.95<\/strong><\/td><\/tr><tr><td>Tenuazonic acid<\/td><td>21503<\/td><td>47828<\/td><td><strong>2.22<\/strong><\/td><td>89293<\/td><td>197658<\/td><td><strong>2.21<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Au\u00dfergew\u00f6hnliche&nbsp;Inertheit&nbsp;trifft auf au\u00dfergew\u00f6hnliche station\u00e4re Phasen&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wir stellen unsere inerte LC-S\u00e4ulentechnologie auf drei S\u00e4ulentypen vor: Raptor Biphenyl, Raptor ARC-18 und Force Biphenyl. Mit diesen neuen S\u00e4ulen k\u00f6nnen Labore, die auf LC-MS\/MS-Workflows f\u00fcr&nbsp;\u201esmall&nbsp;molecules\u201c&nbsp;spezialisiert sind, von den Vorteilen der inerten S\u00e4ulentechnologie profitieren.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Raptor LC S\u00e4ulen<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"340\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-raptor-cropped-1.jpg\" alt=\"\" class=\"wp-image-63820\" style=\"width:313px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-raptor-cropped-1.jpg 1000w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-raptor-cropped-1-300x102.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-raptor-cropped-1-768x261.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Raptor-LC-S\u00e4ulen kombinieren die Geschwindigkeit von 2,7 \u00b5m&nbsp;Core-Shell&nbsp;S\u00e4ulen&nbsp;mit der Aufl\u00f6sung der USLC-Technologie (Ultra&nbsp;Selective&nbsp;Liquid&nbsp;Chromatography), wodurch die Trennungen verbessert und die Analysezeiten mit Standard-HPLC-Ger\u00e4ten verk\u00fcrzt werden. Wenn Geschwindigkeit Ihr Ziel ist, empfiehlt Restek die Raptor-LC-S\u00e4ulen.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Erfahren Sie mehr auf\u00a0<a href=\"https:\/\/www.restek.com\/Raptor\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/Raptor<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Raptor Inert Biphenyl<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Unsere branchenf\u00fchrende&nbsp;Biphenyl-Phase&nbsp;ist unsere beliebteste station\u00e4re LC-Phase. Sie eignet sich besonders gut f\u00fcr die Trennung von Verbindungen, die schwer aufzul\u00f6sen sind&nbsp;(Isomere, Isobare)&nbsp;oder die auf C18 und anderen&nbsp;Phenylphasen&nbsp;fr\u00fch eluieren.&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Raptor Inert ARC-18<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Die Raptor ARC-18-S\u00e4ule verf\u00fcgt \u00fcber ein ausgewogenes Retentionsprofil&nbsp;und ist besonders f\u00fcr die Massenspektrometrie geeignet, da sie&nbsp;gegen\u00fcber den&nbsp;erforderlichen aggressiven, sauren mobilen Phasen&nbsp;deutlich stabiler ist als eine gew\u00f6hnliche C18-S\u00e4ule.&nbsp;Selbst nach l\u00e4ngerem Einsatz&nbsp;bei&nbsp;so&nbsp;niedrigen&nbsp;pH-Werten&nbsp;(\u2264 2,0) bietet die sterisch gesch\u00fctzte ARC-18 eine&nbsp;konsistente&nbsp;Retention,&nbsp;Peakform&nbsp;und&nbsp;Response&nbsp;f\u00fcr geladene Basen, neutrale S\u00e4uren, kleine polare Verbindungen und mehr.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Force LC S\u00e4ulen<\/h3>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"303\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-force-cropped-1.jpg\" alt=\"\" class=\"wp-image-63828\" style=\"width:334px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-force-cropped-1.jpg 1000w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-force-cropped-1-300x91.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-force-cropped-1-768x233.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">Die&nbsp;vollpor\u00f6sen&nbsp;Force&nbsp;Partikel&nbsp;sind f\u00fcr hohe Dr\u00fccke und hohe Belastungen ausgelegt und hergestellt. Sie sind langlebig, reproduzierbar und von erstklassiger Qualit\u00e4t &#8211; gesichert durch unsere 100%ige Zufriedenheitsgarantie. Wenn Sie eine h\u00f6here Retention und sch\u00e4rfere Peaks ben\u00f6tigen, sind Force LC-S\u00e4ulen bereit f\u00fcr den Einsatz.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Erfahren Sie mehr auf\u00a0<a href=\"https:\/\/www.restek.com\/Force\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/Force<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Force Inert Biphenyl<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">Die Force Inert Biphenyl-S\u00e4ule trennt Verbindungen, die andere Phenyl- und C18-S\u00e4ulen nicht trennen k\u00f6nnen. Sie&nbsp;kann&nbsp;mit&nbsp;einfachen, MS-freundlichen&nbsp;mobilen&nbsp;Phasen&nbsp;verwendet werden&nbsp;und&nbsp;ist&nbsp;ideal, wenn Sie die Retention von hydrophilen Aromaten erh\u00f6hen m\u00fcssen.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Au\u00dfergew\u00f6hnliche&nbsp;Inertheit&nbsp;f\u00fcr ihre&nbsp;Analytik&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Da wir&nbsp;selbst&nbsp;im Labor stehen, wissen wir, wie wichtig es ist, sich auf&nbsp;seine&nbsp;Daten verlassen zu k\u00f6nnen. Ganz gleich, ob Sie Pestizide, Mykotoxine oder andere metallsensitive Verbindungen analysieren, diese neuen LC-S\u00e4ulen bieten die Genauigkeit, den Durchsatz und die Leistung, die Ihr Labor&nbsp;braucht.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wenden Sie sich noch heute an Ihren \u00f6rtlichen Restek-Vertreter unter\u00a0<a href=\"https:\/\/www.restek.com\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/contact-us<\/a>,\u00a0um die Vorteile unserer inerten Technologie f\u00fcr Ihre Applikation auszuprobieren.<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Erw\u00e4hnte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9314A12-T\">                                Art.-Nr. 9314A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert ARC-18, 2.7 \u00b5m, 100 x 2.1 mm HPLC S\u00e4ule<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9314A12-T\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9309A12-T\">                                Art.-Nr. 9309A12-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert Biphenyl, 2.7 \u00b5m, 100 x 2.1 mm HPLC S\u00e4ule<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9309A12-T\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9629312-T\">                                Art.-Nr. 9629312-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force Inert Biphenyl, 3 \u00b5m, 100 x 2.1 mm LC S\u00e4ule<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/9629312-T\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31971\">                                Art.-Nr. 31971                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LC Multipestizid Standard Kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31971\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34121\">                                Art.-Nr. 34121                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Aflatoxine (B1, B2, G1, G2) Standard 10 \u00b5g\/mL, Acetonitril, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34121\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34122\">                                Art.-Nr. 34122                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ochratoxin-Standard, 10 \u00b5g\/mL, Acetonitril, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34122\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/32475\">                                Art.-Nr. 32475                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LC Passivierungsl\u00f6sung, Methylendiphosphons\u00e4ure (Medrons\u00e4ure), 1760 \u03bcg\/mL, Methanol (HPLC Qualit\u00e4t)\/Wasser (50:50), 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/32475\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Our new inert LC column technology helps labs improve their analysis of metal-sensitive compounds. A premium inert coating applied to the stainless-steel surface of our LC columns reduces nonspecific binding of chelating analytes, enabling sensitive analysis and smooth integration of peaks.<\/p>\n","protected":false},"author":11,"featured_media":7471,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2223,2236,2241,2230],"post-badge":[],"resource-type":[],"product-library":[2481,2499,2500],"resource-technique":[2363],"ppma_author":[414],"class_list":["post-45295","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-klinisch","industries-application-lebensmittel-getranke","industries-application-pharmazeutika-biopharma","industries-application-umweltbereich","product-library-flussigchromatographie-produkte","product-library-lc-saulen","product-library-lc-ms","resource-technique-ms-ms-de"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2223,"label":"Klinisch"},{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"},{"value":2241,"label":"Pharmazeutika &amp; Biopharma"},{"value":2230,"label":"Umweltbereich"}],"product-library":[{"value":2481,"label":"Fl\u00fcssigchromatographie Produkte"},{"value":2499,"label":"LC S\u00e4ulen"},{"value":2500,"label":"LC-MS"}],"resource-technique":[{"value":2363,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS4155-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":787,"category_count":506,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=45295"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45295\/revisions"}],"predecessor-version":[{"id":87792,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/45295\/revisions\/87792"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/7471"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=45295"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=45295"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=45295"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=45295"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=45295"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=45295"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=45295"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=45295"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=45295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}