   {"id":51639,"date":"2021-10-06T14:30:00","date_gmt":"2021-10-06T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse\/"},"modified":"2026-01-28T15:50:47","modified_gmt":"2026-01-28T15:50:47","slug":"chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/blogs\/gnbl4621\/chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse","title":{"rendered":"Chiral Separations 4: Separation with Rt-\u03b2DEXm, Rt-\u03b2DEXsm and Rt-\u03b2DEXse"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In my previous chiral column blogs, I\u2019ve discussed how they compare, how to optimize the separations and column capacity. This blog focuses on individual columns and specific separations. We\u2019ll start with Rt-\u03b2DEXm, Rt-\u03b2DEXsm and Rt-\u03b2DEXse (Table 1).<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Table 1: Resolution of selected chiral compounds by Rt-\u03b2DEXm, Rt-\u03b2DEXsm and Rt-\u03b2DEXse<\/strong><\/h5>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><strong>Rt-\u03b2DEXm<\/strong><\/td><td><strong>Rt-\u03b2DEXsm<\/strong><\/td><td><strong>Rt-\u03b2DEXse<\/strong><\/td><\/tr><tr><td><strong>\u03b1-pinene<\/strong><\/td><td>3.89<\/td><td>3.14<\/td><td>0.82<\/td><\/tr><tr><td><strong>limonene<\/strong><\/td><td>1.53<\/td><td>5.60<\/td><td>3.10<\/td><\/tr><tr><td><strong>linalool<\/strong><\/td><td>1.01<\/td><td>3.10<\/td><td>5.96<\/td><\/tr><tr><td><strong>\u03b1-terpineol<\/strong><\/td><td>1.84<\/td><td>4.72<\/td><td>5.20<\/td><\/tr><tr><td><strong>isoborneol<\/strong><\/td><td>2.20<\/td><td>3.76<\/td><td>3.35<\/td><\/tr><tr><td><strong>menthol<\/strong><\/td><td>1.73<\/td><td>1.24<\/td><td>1.24<\/td><\/tr><tr><td><strong>2,3-butanediol<\/strong><\/td><td>2.94<\/td><td>6.44<\/td><td>7.10<\/td><\/tr><tr><td><strong>1-phenylethanol<\/strong><\/td><td>6.93<\/td><td>7.52<\/td><td>6.52<\/td><\/tr><tr><td><strong>\u03b1-ionone<\/strong><\/td><td>3.45<\/td><td>5.67<\/td><td>3.31<\/td><\/tr><tr><td><strong>menthone<\/strong><\/td><td>4.11<\/td><td>0.59<\/td><td>5.76<\/td><\/tr><tr><td><strong>ethyl-2-methylbutyrate<\/strong><\/td><td>1.00<\/td><td>3.94<\/td><td>4.66<\/td><\/tr><tr><td><strong>linalyl acetate<\/strong><\/td><td>ns<\/td><td>ns<\/td><td>2.36<\/td><\/tr><tr><td><strong>styrene oxide<\/strong><\/td><td>3.34<\/td><td>4.53<\/td><td>10.77<\/td><\/tr><tr><td><strong><em>trans<\/em>-linalool oxide<\/strong><\/td><td>9.74<\/td><td>9.71<\/td><td>2.96<\/td><\/tr><tr><td><strong><em>cis<\/em>-linalool oxide<\/strong><\/td><td>5.65<\/td><td>6.06<\/td><td>4.28<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">All chromatograms were collected using the following method:&nbsp;<strong>Oven temp.:<\/strong>&nbsp;40\u00b0C (hold 1 min.) to 230\u00b0C @ 2\u00b0C\/min. (hold 3 min.);&nbsp;<strong>Carrier gas:<\/strong>&nbsp;hydrogen; 80cm\/sec. set @ 40\u00b0C;&nbsp;<strong>Detector<\/strong>: FID set @ 220\u00b0C.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-\u03b2DEXm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s start with the most basic chiral column, the Rt-\u03b2DEXm, which is permethylated \u03b2-cyclodextrin added into midpolarity cyano\/phenyl polymer (the same as 1701 phase). Based on our table (Table 1), Rt-\u03b2DEXm resolves well&nbsp;<strong>\u03b1-pinene, menthol, 1-phenylethanol, methone and linalool oxides<\/strong>. In addition, this column resolved&nbsp;<strong>menthol<\/strong>&nbsp;better than any other chiral column in our study. Figure 1 shows the separation of menthol (A) and menthone (B) on Rt-\u03b2DEXm, because these two compounds are commonly found together in mint oils.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-01.png\" alt=\"lighting\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 1: Methol (A) and Menthone (B) resolution on Rt-\u03b2DEXm (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13101)<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-\u03b2DEXsm<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Rt-\u03b2DEXsm separates 20 of the 21 tested compounds, with 16 being baseline resolved. This column provides very good enantiomeric separation (Table 1) of&nbsp;<strong>\u03b1-pinene, \u03b1-ionone (Fig 2A), \u03b1-terpineol (Fig 2B), isoborneol (Fig 2C), 1-phenylethanol, 2,3-butanediol and linalool oxides (Fig 3).<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-02.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 2: \u03b1-ionone (A), \u03b1-terpineol (B) and isoborneol (C) resolution on Rt-\u03b2DEXsm (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13104)<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-03.png\" alt=\"shape\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 3: Trans-linalool oxide (1) and cis-linalool oxide (2) resolution on Rt-\u03b2DEXsm (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13104)<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rt-\u03b2DEXse<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The Rt-\u03b2DEXse is similar in performance to the Rt-\u03b2DEXsm, but&nbsp;it&nbsp;provides better resolution for&nbsp;<strong>limonene,&nbsp;<\/strong><strong>\u03b1-terpineol, linalool, linalyl acetate (Fig 4), ethyl-2-methylbutyrate (Fig 5A), 2,3-butanediol, menthone (Fig 5B) and styrene oxides<\/strong>.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-04.png\" alt=\"a blue line in the dark\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 4: Linalool and linalyl acetate resolution on Rt-\u03b2DEXse (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13106)<\/em><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-05.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 5: Ethyl2-methylbutyrate (A) and menthone (B) resolution on Rt-\u03b2DEXse (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13106)<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sometimes extensive separation results in overlap of enantiomeric pairs (Fig 6B).<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-chiral-separation-4-separation-with-rt-dexm-rt-dexsm-and-rt-dexse-06.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Figure 6: Limonene (A), camphor and styrene oxide (B) resolution on Rt-\u03b2DEXse (30m, 0.32mm ID, 0.25\u00b5m; cat. # 13<\/em>106)<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Erw\u00e4hnte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13101\">                                Art.-Nr. 13101                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chirale GC Kapillars\u00e4ule, Rt-\u03b2DEXm 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13101\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13104\">                                Art.-Nr. 13104                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chirale Kapillars\u00e4ule Rt-\u03b2DEXsm 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13104\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13106\">                                Art.-Nr. 13106                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Chirale GC Kapillars\u00e4ule, Rt-\u03b2DEXse 30 m, 0.32 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13106\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In my previous chiral column blogs, I&rsquo;ve discussed how they compare, how to optimize the separations and column capacity. This blog focuses on individual columns and specific separations.&nbsp;<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2149,2167],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2294],"ppma_author":[591],"class_list":["post-51639","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-cannabis","industries-application-food-beverage","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2149,"label":"Cannabis"},{"value":2167,"label":"Food &amp; Beverage"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/de\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=51639"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51639\/revisions"}],"predecessor-version":[{"id":85256,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51639\/revisions\/85256"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=51639"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=51639"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=51639"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=51639"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=51639"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=51639"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=51639"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=51639"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=51639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}