{"id":51678,"date":"2011-08-24T00:00:00","date_gmt":"2011-08-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions\/"},"modified":"2025-10-24T16:47:51","modified_gmt":"2025-10-24T16:47:51","slug":"faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/blog-fr\/gnbl4660\/faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions","title":{"rendered":"Fast(er) GC: How to Decrease Analysis Time using Existing Instrumentation? Part I: Impact of column dimensions."},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"118\" height=\"114\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-01.jpg\" alt=\"\" class=\"wp-image-14260\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">When talking with customers, I always hear there is a lot of interest in doing faster GC. Often people think they have to buy new instrumentation to do that. Sometimes it\u2019s necessary if you have a 20 year old GC, but for most GC\u2019s of younger age, you can easily develop method to go faster.\u00a0 What you need to know is what your objectives are.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There are roughly 2 situations:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><em><strong>We have plenty of resolution between the components of interest. Here we trade some efficiency in\u00a0 favor for a faster analysis<\/strong><\/em><\/li>\n\n\n\n<li><em><strong>We have \u201cjust\u201d enough resolution. Here we need for the faster solution at least similar efficiency (plate number).<\/strong><\/em><\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"989\" height=\"206\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-02.png\" alt=\"\" class=\"wp-image-14266\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-02.png 989w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-02-300x62.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-02-768x160.png 768w\" sizes=\"auto, (max-width: 989px) 100vw, 989px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 1 generalized resolution equation<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the first case we can manipulate several parameters to reduce the analysis time. Let\u2019s first take a look at the column dimensions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As we have plenty of resolution, we should be able to choose a column with less separation power.&nbsp; <strong>The most easy is to use a shorter column length<\/strong>. &nbsp;Looking at the resolution equation in fig.1, we see the resolution is linear to the square of the plate number. This means that when I reduce the column length by a factor 2, the resolution only reduces by a factor 1.4.&nbsp; The analysis time however reduces immediately by a factor 2.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"709\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-03-709x1024.gif\" alt=\"\" class=\"wp-image-14272\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-03-709x1024.gif 709w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-03-208x300.gif 208w\" sizes=\"auto, (max-width: 709px) 100vw, 709px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig.2 Comparison of analysis time of a 60 and a 30m column; Isothermal analysis on Rt Alumina BOND. The 30m is 2x faster.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Fig 2 shows the effect of length on analysis time using a 60 and a 30 m Rt Alumina BOND column. The alumina BOND is very selective for C1-C5 hydrocarbons, meaning that the components are all very well resolved.&nbsp; The analysis was done in the same GC, same carrier gas and the result shows a very simple reduction of analysis time by a factor 2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">By changing ONLY the column length, the only change we had to make was setting a lower inlet pressure. Very easy to implement for isothermal methods.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For temperature programmed methods, we have to adjust besides the inlet pressure, also the temperature program rate and the iso times.&nbsp; Reason for this is, that we like to have exactly the SAME separation. This only happens if the elution temperatures are kept the same.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">If we reduce the column length by a factor 2, we need to<strong> increase<\/strong> <strong>the program rate<\/strong> by a factor 2 and <strong>decrease the iso-times<\/strong> by a factor 2.&nbsp; Example calculation is shown in figure 3. When we make these changes, we also will get exactly a factor 2 shorter run time while elution temperatures remain the same.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This can be done basically for all methods where there is plenty of resolution. The limitation is usually set by the maximum temperature program the oven can accommodate. Most GC\u2019s can program with 25-30C\/min, but above 200C it becomes difficult. &nbsp;One can make the GC keep up with the higher temperature program rates by using a 220V OR using an oven \u2013insert.. By reducing the oven size, the systems can heat up much faster.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"720\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-faster-gc-how-to-decrease-analysis-time-using-existing-instrumentation-part-i-impact-of-column-dimensions-04.gif\" alt=\"\" class=\"wp-image-14278\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig.3 Example of new temperature program when replacing a 30m for a 15 m column: elution temperatures will be similar resulting in same chromatogram, just 2x faster<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">To produce less plates one can also use a wider diameter column of same or shorter length, or use a much shorter column with smaller diameter. Choosing the wider diameter in shorter length will also be an option, but we have to be more careful with adjusting pressures and oven programming-rate. The&nbsp; much shorter smaller ID column will be faster, but will also challenge the method on setting of operational parameters like pressures, program rates,&nbsp; injection speed and loadability. We will discuss this one later if we are going for speeding up situation 2.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Next time we will discuss how we manipulate run time using flow..<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>When talking with customers, I always hear there is a lot of interest in doing faster GC. Often people think they have to buy new instrumentation to do that. Sometimes it&rsquo;s necessary if you have a 20 year old GC,&#8230;<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[791],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[562],"product-library":[],"resource-technique":[2316],"ppma_author":[439],"class_list":["post-51678","post","type-post","status-publish","format-standard","hentry","category-blog-fr","resource-type-chromatography-fundamentals","resource-technique-chromatographie-en-phase-gazeuse-gc"],"acf":[],"taxonomy_info":{"category":[{"value":791,"label":"Blog"}],"resource-type":[{"value":562,"label":"Chromatography Fundamentals"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/de\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":791,"name":"Blog","slug":"blog-fr","term_group":0,"term_taxonomy_id":791,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":791,"category_count":457,"category_description":"","cat_name":"Blog","category_nicename":"blog-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51678","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=51678"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51678\/revisions"}],"predecessor-version":[{"id":56946,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/51678\/revisions\/56946"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=51678"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=51678"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=51678"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=51678"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=51678"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=51678"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=51678"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=51678"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=51678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}