{"id":60095,"date":"2025-11-04T18:18:46","date_gmt":"2025-11-04T18:18:46","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60095"},"modified":"2026-08-11T18:29:44","modified_gmt":"2026-08-11T18:29:44","slug":"advances-in-sample-preparation-workflows-for-oral-fluid-analysis","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/posters-presentations\/gnot5263\/advances-in-sample-preparation-workflows-for-oral-fluid-analysis","title":{"rendered":"Advances in Sample Preparation Workflows for Oral Fluid Analysis"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The analysis of drugs of abuse in oral fluids is a solution that is gaining popularity due to its less invasive collection technique as compared to blood or urine collection. However, there are some issues with the buffer used in the collection devices for oral fluid testing. It is often difficult to remove all of the surfactants from the buffer, which can cause matrix effects. Oftentimes solid phase extraction or lengthy extraction techniques are utilized. Finding a method that uses a simple sample preparation paired with accurate and robust quantitation of the analytes is important for laboratories running these tests. An LC-MS\/MS method was developed for the quantitation of these compounds using a Raptor Biphenyl 50 x 2.1 mm, 2.7 \u00b5m analytical column equipped with a Raptor Biphenyl EXP 5 x 2 mm, 2.7 \u00b5m guard column. Samples were prepared in oral fluid and combined with Quantisal buffer. Samples were tested using three different sample preparation techniques: salt-assisted liquid-liquid extraction (SALLE); supported liquid extraction (SLE); and dilute and shoot. The results of these extraction techniques were investigated and compared using recovery, linearity, matrix effects, and accuracy and precision.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/AAFS-2025-Oral-Fluids-Sample-Prep-Comparisons_poster-final.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of AAFS 2025 Oral Fluids Sample Prep Comparisons_poster final.\"><\/object><a id=\"wp-block-file--media-c8e49931-ecdb-429f-95d5-5463dbcfc4f4\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/AAFS-2025-Oral-Fluids-Sample-Prep-Comparisons_poster-final.pdf\">AAFS 2025 Oral Fluids Sample Prep Comparisons_poster final<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/AAFS-2025-Oral-Fluids-Sample-Prep-Comparisons_poster-final.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-c8e49931-ecdb-429f-95d5-5463dbcfc4f4\">Download<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>The analysis of drugs of abuse in oral fluids is a solution that is gaining popularity due to its less invasive collection technique as compared to blood or urine collection. However, there are some issues with the buffer used in the collection devices for oral fluid testing. It is often difficult to remove all of the surfactants from the buffer, which can cause matrix effects. Oftentimes solid phase extraction or lengthy extraction techniques are utilized. Finding a method that uses a simple sample preparation paired with accurate and robust quantitation of the analytes is important for laboratories running these tests. An LC-MS\/MS method was developed for the quantitation of these compounds using a Raptor Biphenyl 50 x 2.1 mm, 2.7 \u00b5m analytical column equipped with a Raptor Biphenyl EXP 5 x 2 mm, 2.7 \u00b5m guard column. Samples were prepared in oral fluid and combined with Quantisal buffer. Samples were tested using three different sample preparation techniques: salt-assisted liquid-liquid extraction (SALLE); supported liquid extraction (SLE); and dilute and shoot. The results of these extraction techniques were investigated and compared using recovery, linearity, matrix effects, and accuracy and precision.<\/p>\n","protected":false},"author":24,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2810],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[444,592],"class_list":["post-60095","post","type-post","status-publish","format-standard","hentry","category-posters-presentations"],"acf":[],"taxonomy_info":{"category":[{"value":2810,"label":"Posters &amp; Presentations"}]},"featured_image_src_large":false,"author_info":{"display_name":"Samantha Herbick","author_link":"https:\/\/discover.restek.com\/de\/author\/samantha-herbick\/"},"comment_info":0,"category_info":[{"term_id":2810,"name":"Posters &amp; Presentations","slug":"posters-presentations","term_group":0,"term_taxonomy_id":2810,"taxonomy":"category","description":"","parent":0,"count":125,"filter":"raw","cat_ID":2810,"category_count":125,"category_description":"","cat_name":"Posters &amp; Presentations","category_nicename":"posters-presentations","category_parent":0}],"tag_info":false,"authors":[{"term_id":444,"user_id":24,"is_guest":0,"slug":"samantha-herbick","display_name":"Samantha Herbick","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg"},"author_category":"1","first_name":"Samantha","last_name":"Herbick","user_url":"https:\/\/www.linkedin.com\/in\/samantha-herbick-656378136\/","job_title":"Advanced Scientist, LC Solutions","description":"Samantha Herbick is an applications scientist within the LC Solutions Department at Restek. Her primary focus is on the development of applications in the toxicology and life science markets. She attended Duquesne University where she earned a bachelor\u2019s degree in Biochemistry and a master's degree in forensic science and law. Prior to joining Restek, Samantha worked as a scientist and method developer in a forensic toxicology lab. In this role, she performed analysis on toxicology casework and worked on the development and validation of new and existing assays using LC-MS\/MS, GC-MS, and GC-FID."},{"term_id":592,"user_id":51,"is_guest":0,"slug":"jared-burkhart","display_name":"Jared Burkhart","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-burkhart-jared.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-burkhart-jared.jpg"},"author_category":"1","first_name":"Jared","last_name":"Burkhart","user_url":"https:\/\/www.linkedin.com\/in\/jaredburkhart\/","job_title":"Business Development Manager, Global Sales","description":"Jared Burkhart is the business development manager for life sciences at Restek with a BS in biology and an ASCP (C) certification. He brings 14 years of experience in LC\/MS laboratories supporting both clinical and forensic toxicology, giving him a strong understanding of the analytical and operational needs of these markets. An active member of MATT since 2023 and SOFT since 2025, Jared leverages his technical expertise and industry experience to help laboratories identify solutions that advance their testing capabilities."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=60095"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60095\/revisions"}],"predecessor-version":[{"id":60136,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60095\/revisions\/60136"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=60095"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=60095"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=60095"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=60095"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=60095"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=60095"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=60095"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=60095"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=60095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}