{"id":60360,"date":"2026-06-25T14:00:00","date_gmt":"2026-06-25T14:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60360"},"modified":"2026-09-01T10:59:30","modified_gmt":"2026-09-01T10:59:30","slug":"produktleitfaden-zur-pfas-analyse","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/evar3498-de\/produktleitfaden-zur-pfas-analyse","title":{"rendered":"Produktleitfaden zur PFAS-Analyse"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Ein methodenbasierter Produktleitfaden f\u00fcr PFAS-Analysen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Per- und Polyfluoralkylsubstanzen (PFAS), die sog. \u201eewigen Chemikalien\u201c, sind in der Umwelt allgegenw\u00e4rtig, finden sich aber auch h\u00e4ufig in Materialien und Ger\u00e4ten, die routinem\u00e4\u00dfig im Labor eingesetzt werden. Deshalb ist unbedingt darauf zu achten, dass die zu untersuchenden Proben nicht durch potenzielle Hintergrundquellen verunreinigt werden. PFAS k\u00f6nnen auch \u201eklebrig\u201c sein und sich an bestimmte Materialien anhaften, die \u00fcblicherweise bei Probenahmen und Analysen verwendet werden (z. B. Glasbeh\u00e4lter oder Pipetten). Der gesamte Probenflussweg muss deshalb auf seine F\u00e4higkeit hin untersucht werden, entweder die PFAS-Hintergrundkonzentration zu erh\u00f6hen oder in Proben vorhandene PFAS zur\u00fcckzuhalten.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Das Risiko einer Verunreinigung durch PFAS oder die Zur\u00fcckhaltung von PFAS kann die Auswahl der richtigen Labormaterialien und -ger\u00e4te f\u00fcr PFAS-Analysen schwierig gestalten. Hinzu kommt, dass zahlreiche Methoden mit unterschiedlichen Produkten f\u00fcr die Probenvorbereitung und Analyse verf\u00fcgbar sind. Die Auswahl geeigneter Labormaterialien und -ger\u00e4te ist noch schwieriger, wenn Sie Spurenkonzentrationen von PFAS messen m\u00f6chten, die in den aktuellen beh\u00f6rdlichen Methoden oder Richtlinien nicht aufgef\u00fchrt sind, wie z. B. ultrakurzkettige und kurzkettige PFAS.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die Suche nach geeigneten Produkten kann mithilfe der Tabellen auf den folgenden Seiten vereinfacht werden. Darin sind Laborartikel zur PFAS-Analyse aufgef\u00fchrt, die f\u00fcr weltweit anerkannte Testmethoden geeignet sind, darunter Methoden US-amerikanischer Beh\u00f6rden (CDC, EPA, FDA und USDA), europ\u00e4ischer Beh\u00f6rden (DIN) und Methoden nach internationalen Standards (ASTM und ISO). Nachdem Sie die f\u00fcr die Methode geeigneten Produkte ausgew\u00e4hlt haben, sollten Sie Ihr System und Ihre Verbrauchsmaterialien unbedingt \u00fcberpr\u00fcfen, um sicherzustellen, dass sie frei von Zielanalyten sind und zur PFAS-Analyse in den von der Methode erforderlichen Konzentrationen geeignet sind. &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek ist stolz darauf, PFAS-Pr\u00fcflabore mit sauberen, hochwertigen Labormaterialien f\u00fcr PFAS-Tests und fachkundigem technischen Support f\u00fcr die Analyse von traditionellen, alternativen und ultrakurzkettigen PFAS nach einer Vielzahl globaler Pr\u00fcfstandards zu unterst\u00fctzen. Registrieren Sie sich&nbsp;und<a href=\"https:\/\/explore.restek.com\/PFAS-Guides-DE\" target=\"_blank\" rel=\"noreferrer noopener\">vergleichen Sie die Analytenlisten und Matrizen der verschiedenen Methoden<\/a> mit unserer \u00dcbersicht oder besuchen Sie&nbsp;<a href=\"https:\/\/www.restek.com\/pfas\" target=\"_blank\" rel=\"noopener\">www.restek.com\/PFAS<\/a>, um unsere technischen Ressourcen zur PFAS-Analyse zu erkunden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Labormaterialien f\u00fcr die PFAS-Analyse nach Methode<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Klicken Sie auf eine Methode in den Tabellen\u00fcberschriften, um eine \u00dcbersicht \u00fcber die Methode und eine Liste der empfohlenen Produkte f\u00fcr diese spezifische Methode zu erhalten. Wollen Sie die Ergebnisse Ihrer Methoden sehen, bevor Sie das Labor betreten? Sie k\u00f6nnen PFAS-Methoden in wenigen Minuten von Ihrem Schreibtisch aus mit Resteks kostenlosem, online verf\u00fcgbaren&nbsp;<a href=\"https:\/\/ez.restek.com\/proezlc\/de\" target=\"_blank\" rel=\"noopener\">Pro EZLC Chromatogramm-Modellierer<\/a> entwickeln.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">ANALYSE<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-533-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-1633-for-aqueous-solid-biosolids-and-tissue\" target=\"_blank\" rel=\"noopener\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\" target=\"_blank\" rel=\"noopener\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-and-siluriformes-muscle-and-bovine-plasma\" target=\"_blank\" rel=\"noopener\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-cdc-6304-09-for-serum\" target=\"_blank\" rel=\"noopener\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\" target=\"_blank\" rel=\"noopener\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-en-17892-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\" target=\"_blank\" rel=\"noopener\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-21675-2019-for-water\" target=\"_blank\" rel=\"noopener\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-23702-1-2023-for-leather\" target=\"_blank\" rel=\"noopener\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7968-23-for-soil\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"16\"><strong>C18-S\u00c4ULEN<\/strong><\/td><\/tr><tr><td>PFAS Delay-S\u00e4ule: 5 \u00b5m, 50 x 2.1 mm&nbsp;(<a href=\"https:\/\/www.restek.com\/p\/27854\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr.27854<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>PFAS Delay-S\u00e4ule: 5 \u00b5m, 50 x 3.0 mm&nbsp;<br>(Art.-Nr. 580959 [Spezialprodukt])<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Force C18 FPP-S\u00e4ule:<br>50 x 2.1 mm, 1.8 \u03bcm, (<a href=\"https:\/\/www.restek.com\/p\/9634252\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr. 9634252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 SPP-S\u00e4ule:<br>50 x 2.1 mm, 2.7 \u03bcm, (<a href=\"https:\/\/www.restek.com\/p\/9304A52\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 9304A52<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td colspan=\"16\"><em>Weitere C18-S\u00e4ulendimensionen sind <a href=\"https:\/\/www.restek.com\/c\/lc-pfas?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">hier<\/a>&nbsp;erh\u00e4ltlich.<\/em><\/td><\/tr><tr><td colspan=\"16\"><strong>S\u00c4ULEN MIT SPEZIALPHASEN<\/strong><\/td><\/tr><tr><td>Raptor Polar X:<br>2.7 \u00b5m, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9311A52\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 9311A52<\/a>)<\/td><td colspan=\"15\">Ideal f\u00fcr die Analyse ultrakurzkettiger PFAS (C1-C3) mit isokratischen Methoden. <a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noreferrer noopener\">Sehen Sie sich unsere Methode an!<\/a><\/td><\/tr><tr><td>Ultra IBD:<br>3 \u00b5m, 100 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9175312\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 9175312<\/a>)<\/td><td colspan=\"15\">Ideal f\u00fcr die Analyse ultrakurzkettiger, kurzkettiger, mittelkettiger und langkettiger PFAS (C1-C14) mit Gradientenmethoden.&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/c1-c10-pfas-analysis-in-human-plasma-and-serum\" target=\"_blank\" rel=\"noopener\">Sehen Sie sich unsere Methode an!<\/a><\/td><\/tr><tr><td colspan=\"16\"><strong>VORS\u00c4ULEN<\/strong><\/td><\/tr><tr><td>UltraShield UHPLC Vors\u00e4ulen-Filter, 0.2 \u00b5m Fritte (<a href=\"https:\/\/www.restek.com\/p\/25809\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 25809<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>EXP Direct Connect-Halter f\u00fcr EXP&nbsp;<br>Vors\u00e4ulenkartuschen, enth\u00e4lt Fittings und Ferrules&nbsp;(<a href=\"https:\/\/www.restek.com\/p\/25808\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 25808<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 EXP Vors\u00e4ulenkartusche, 2.7 \u00b5m, 5 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9304A0252\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 9304A0252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HINWEIS<\/strong>: Einige der oben gezeigten Produkte entsprechen m\u00f6glicherweise nicht genau der Produktbeschreibung in den Methoden.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">**DIN EN 17892 f\u00fchrt im Anhang S\u00e4ulen in folgenden Dimensionen auf: Force C18 S\u00e4ule (vollpor\u00f6s): 1.8 \u00b5m, 100 x 3.0 mm (Art.-Nr. 963421E) und Raptor C18 S\u00e4ule (Core-Shell): 2.7 \u00b5m, 100 x 2.1 mm (Art.-Nr. 9304A12).<br><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">STANDARDS<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Die unter www.restek.com gezeigten Produkte enthalten detaillierte Listen der Verbindungen.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-533-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-1633-for-aqueous-solid-biosolids-and-tissue\" target=\"_blank\" rel=\"noopener\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\" target=\"_blank\" rel=\"noopener\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-and-siluriformes-muscle-and-bovine-plasma\" target=\"_blank\" rel=\"noopener\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-cdc-6304-09-for-serum\" target=\"_blank\" rel=\"noopener\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\" target=\"_blank\" rel=\"noopener\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-en-17892-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\" target=\"_blank\" rel=\"noopener\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-21675-2019-for-water\" target=\"_blank\" rel=\"noopener\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-23702-1-2023-for-leather\" target=\"_blank\" rel=\"noopener\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7968-23-for-soil\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td>PFAS 24 Kalibrierstandard: 1 \u00b5g\/mL, Methanol&nbsp;(1 mM KOH\/2-propanol [98:2]) (<a href=\"https:\/\/www.restek.com\/p\/30733\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr. 30733)<\/a><\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS 28 Kalibrierstandard: 1 \u00b5g\/mL, Methanol&nbsp;(1 mM KOH\/2-propanol [98:2]) (<a href=\"https:\/\/www.restek.com\/p\/30734\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr. 30734<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS EPA Methode 533 Analyt Prim\u00e4rverd\u00fcnnungsstandard (PDS) 2 \u00b5g\/ml, Methanol (1 mM NaOH)\/2-Propanol (98:2), 1.2 mL\/Ampulle (<a href=\"https:\/\/www.restek.com\/p\/30840\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr. 30840<\/a>)<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS EPA-Methode 537.1 Analyt-Prim\u00e4rverd\u00fcnnungsstandard (PDS) 2 \u00b5g\/mL, Methanol (1 mM NaOH)\/2-Propanol (98:2), 1.2 mL\/Ampulle (<a href=\"https:\/\/www.restek.com\/p\/30840\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr. 30841<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HINWEIS<\/strong>: Einige der oben gezeigten Produkte entsprechen m\u00f6glicherweise nicht genau der Produktbeschreibung in den Methoden.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">PROBENHANDHABUNG<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>Produkt-<\/strong><br><strong>kategorie<\/strong><\/td><td><strong>Beschreibung<\/strong><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-533-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-1633-for-aqueous-solid-biosolids-and-tissue\" target=\"_blank\" rel=\"noopener\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\" target=\"_blank\" rel=\"noopener\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-and-siluriformes-muscle-and-bovine-plasma\" target=\"_blank\" rel=\"noopener\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-cdc-6304-09-for-serum\" target=\"_blank\" rel=\"noopener\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\" target=\"_blank\" rel=\"noopener\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-en-17892-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\" target=\"_blank\" rel=\"noopener\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-21675-2019-for-water\" target=\"_blank\" rel=\"noopener\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-23702-1-2023-for-leather\" target=\"_blank\" rel=\"noopener\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7968-23-for-soil\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"17\"><strong>PRESCREENING ODER FILTRATION VON PARTIKELHALTIGEN PROBEN<\/strong><\/td><\/tr><tr><td rowspan=\"3\">Spritzenfilter<\/td><td>30 mm Spritzenfilter:&nbsp;0.45 \u00b5m, nylon (<a href=\"https:\/\/www.restek.com\/p\/23981\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23981<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>30 mm Spritzenfilter: 0.22 \u00b5m, nylon (<a href=\"https:\/\/www.restek.com\/p\/23980\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23980<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>25 mm Spritzenfilter: &nbsp;0.22 \u00b5m, Polypropylen (<a href=\"https:\/\/www.restek.com\/p\/28935\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28935<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Glaswolle<\/td><td>Deaktivierte Borosilikat-Glaswolle (<a href=\"https:\/\/www.restek.com\/p\/20789\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 20789<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>Weitere Filter Vial-Materialien und -Formate sind&nbsp;<a href=\"https:\/\/www.restek.com\/c\/1337?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">hier<\/a>&nbsp;verf\u00fcgbar.<\/em><\/td><\/tr><tr><td colspan=\"17\"><strong>PROBENAHME, TRANSFER UND EXTRAKTION<\/strong><\/td><\/tr><tr><td rowspan=\"5\">SPE (WAX)<\/td><td>Resprep PFAS SPE Kartusche, 6 mL, WAX 150 mg\/GCB 50 mg (<a href=\"https:\/\/www.restek.com\/p\/28291\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28930<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep PFAS-Kartuschen mit werkseitig verpacktem Filterhilfsmittel, 6 mL, Filterhilfsmittel 2000 mg\/WAX 150 mg\/GCB 50 mg (<a href=\"https:\/\/www.restek.com\/p\/28931\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28931<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep Polymerische SPE-Kartusche: WAX, 6 mL\/500 mg, 30 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/28268\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28268<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep Polymerische SPE-Kartusche: WAX, 6 mL\/200 mg, 30 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/28292\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28292<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>Weitere WAX SPE-Konfigurationen sind&nbsp;<a href=\"https:\/\/www.restek.com\/c\/sp-pfas?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noopener\">hier<\/a>&nbsp;verf\u00fcgbar.<\/em><\/td><\/tr><tr><td>SPE (S-DVB)<\/td><td>Resprep S-DVB SPE-Kartusche: 6 mL\/500 mg (<a href=\"https:\/\/www.restek.com\/p\/28937\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28937<\/a>)<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td><strong>*<\/strong><\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Polypropylen-Probenbeh\u00e4lter<\/td><td>Polypropylen-Probenbeh\u00e4lter: 75 mL (<a href=\"https:\/\/www.restek.com\/p\/26015\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 26015<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Polypropylen<br>-Verbinder<\/td><td>Polypropylen-Verbinder (<a href=\"https:\/\/www.restek.com\/p\/26007\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 26007<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">QuEChERS<br>extraktionssalze<\/td><td>Nur Q-sep QuEChERS-Extraktionssalz-P\u00e4ckchen kOriginal): 6 g MgSO4, 1,5 g NaCl (Art.-Nr. 582025 [Sonderprodukt]) &nbsp;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>Weitere QuEChERS-Produkte sind&nbsp;<a href=\"https:\/\/www.restek.com\/c\/1134\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/c\/1134\" rel=\"noreferrer noopener\">hier<\/a>&nbsp;verf\u00fcgbar.<\/em><\/td><\/tr><tr><td>Harz<\/td><td>Clean SDVB Harz (<a href=\"https:\/\/de.restek.com\/p\/24230\" target=\"_blank\" rel=\"noopener\">Art.-Nr. 24230<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">Vakuum-<br>Absaugstation<\/td><td>Resprep QR-24 Vakuum-Absaugstation (<a href=\"https:\/\/www.restek.com\/p\/28299-VM\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28299-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep QR-12 Vakuum-Absaugstation<br>&nbsp;(<a href=\"https:\/\/www.restek.com\/p\/28298-VM\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28298-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">Vakuumpumpen<\/td><td>Chemker 300 PTFE Vakuumpumpe: 20 L\/min, AC110 V, 60 Hz (<a href=\"https:\/\/www.restek.com\/p\/27426\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27426<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Chemker 300 PTFE Vakuumpumpe: 18 L\/min, AC220 V, 50 Hz (<a href=\"https:\/\/www.restek.com\/p\/27427\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27427<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HINWEIS:<\/strong> Einige der oben gezeigten Produkte entsprechen m\u00f6glicherweise nicht genau der Produktbeschreibung in den Methoden.&nbsp;<br><strong>*<\/strong> Diese CDC-Methode basiert auf automatisierter Online-SPE unter Verwendung von C8- oder C18-SPE-Materialien. Das hier gezeigte Produkt wird f\u00fcr die Offline-SPE empfohlen<br><sup>\u2020<\/sup> Diese Methode der US-amerikanischen FDA verwendet Nano-Filter-Vials ohne Kappen, aber Polyethylenkappen (Art.-Nr <a href=\"https:\/\/www.restek.com\/p\/23244\" target=\"_blank\" rel=\"noreferrer noopener\">23244<\/a> und Art.-Nr <a href=\"https:\/\/www.restek.com\/p\/23247\" target=\"_blank\" rel=\"noreferrer noopener\">23247<\/a>) k\u00f6nnen separat bestellt werden.<br><strong>X<\/strong> In der Methode wird ein regenerierter Zellulosefilter erw\u00e4hnt. Nylon und Polypropylen sind jedoch allgemein anerkannte Filtermembranmaterialien f\u00fcr die PFAS-Analyse.<br><strong>X<\/strong> In der Methode wird ein Glasfaserfilter erw\u00e4hnt. Nylon und Polypropylen sind jedoch allgemein anerkannte Filtermembranmaterialien f\u00fcr die PFAS-Analyse.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">ALLGEMEINE LABORMATERIALIEN<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-537-1-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-533-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-1633-for-aqueous-solid-biosolids-and-tissue\" target=\"_blank\" rel=\"noopener\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-otm-45-for-emissions\" target=\"_blank\" rel=\"noopener\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-epa-method-8327-for-surface-water-groundwater-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-usda-clg-pfas-2-04-for-bovine-porcine-poultry-and-siluriformes-muscle-and-bovine-plasma\" target=\"_blank\" rel=\"noopener\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-cdc-6304-09-for-serum\" target=\"_blank\" rel=\"noopener\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-us-fda-c-010-03-for-food-and-feed\" target=\"_blank\" rel=\"noopener\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-en-17892-for-drinking-water\" target=\"_blank\" rel=\"noopener\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge\" target=\"_blank\" rel=\"noopener\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-21675-2019-for-water\" target=\"_blank\" rel=\"noopener\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-iso-23702-1-2023-for-leather\" target=\"_blank\" rel=\"noopener\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7968-23-for-soil\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/www.restek.com\/articles\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater\" target=\"_blank\" rel=\"noopener\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td>Polypropylen-Vials: 100er Pack. (<a href=\"https:\/\/www.restek.com\/p\/23243\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23243<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Polypropylen-Vials: 1000er Pack. (<a href=\"https:\/\/www.restek.com\/p\/23246\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23246<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Polypropylen-Vial-Kappen: 100er Pack. (<a href=\"https:\/\/www.restek.com\/p\/23244\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23244<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Polypropylen-Vial-Kappen: 1000er Pack. (<a href=\"https:\/\/www.restek.com\/p\/23247\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 23247<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Zentrifugenr\u00f6hrchen: 50 mL, 50er Pack. (<a href=\"https:\/\/www.restek.com\/p\/25846\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 25846<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Zentrifugenr\u00f6hrchen: 50 mL, 500er Pack. (<a href=\"https:\/\/www.restek.com\/p\/28290\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 28290<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Norm-Ject-Plastikspritze: 10 mL Luer-Lock-Spitze (<a href=\"https:\/\/www.restek.com\/p\/22775\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 22775<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><tr><td>Norm-Ject-Plastikspritze: 5 mL Luer-Lock-Spitze (<a href=\"https:\/\/www.restek.com\/p\/22774\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 22774<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>HINWEIS:<\/strong> Einige der oben gezeigten Produkte entsprechen m\u00f6glicherweise nicht genau der Produktbeschreibung in den Methoden.<br><strong>X<\/strong> ASTM-Methoden erw\u00e4hnen die Verwendung einer Glasspritze. Norm-Ject-Plastikspritzen werden aus Polypropylen\/Polyethylen gefertigt und k\u00f6nnen als Alternative verwendet werden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Empfohlene Produkte f\u00fcr die Analyse fl\u00fcchtiger fluorierter Verbindungen (VFCs) gem\u00e4\u00df U.S. EPA OTM-50 (GC-MS)<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/www.restek.com\/articles\/vfc-analysis-by-us-epa-method-otm-50-for-emissions\" target=\"_blank\" rel=\"noopener\"><strong>EPA OTM-50<\/strong><\/a><\/td><\/tr><tr><td colspan=\"2\"><strong>SPROBENAHME\/TRANSPORT<\/strong><\/td><\/tr><tr><td>SilcoCan-Luftprobenahmebeh\u00e4lter, 6 L, mit Siltek-beschichtetem 3-Wege-RAVE+-Ventil mit Manometer (<a href=\"https:\/\/www.restek.com\/p\/27309\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27309<\/a>)<\/td><td>X<\/td><\/tr><tr><td>SilcoCan-Luftprobenahmebeh\u00e4lter, 6 L, mit Siltek-beschichtetem 2-Wege-RAVE+-Ventil (<a href=\"https:\/\/www.restek.com\/p\/27307\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27307<\/a>)<\/td><td>X<\/td><\/tr><tr><td>SilcoCan-Luftprobenahmebeh\u00e4lter, 6 L, ohne Ventil (<a href=\"https:\/\/www.restek.com\/p\/22092\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 22092<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Luftprobenahmebeh\u00e4lter, 6 L, mit 3-Wege-RAVE+-Ventil mit Manometer (<a href=\"https:\/\/www.restek.com\/p\/27319\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27319<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Luftprobenahmebeh\u00e4lter, 6 L, mit 2-Wege-RAVE+-Ventil (<a href=\"https:\/\/www.restek.com\/p\/27318\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 27318<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Luftprobenahmebeh\u00e4lter, 6 L, ohne Ventil (<a href=\"https:\/\/www.restek.com\/p\/22096\" target=\"_blank\" rel=\"noreferrer noopener\">Art.-Nr 22096<\/a>)<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Literaturhinweise<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Restek Corporation, Guide to PFAS testing methods, a global survey of PFAS testing methods and guidelines, Technical article, &nbsp;EVAR3552C-UNV, 2024. <a href=\"https:\/\/www.restek.com\/articles\/guide-to-pfas-testing-methods\" target=\"_blank\" rel=\"noopener\">https:\/\/www.restek.com\/articles\/guide-to-pfas-testing-methods<\/a><\/li>\n\n\n\n<li>S.H., Liang, J. A. Steimling, ,M. Chang Analysis of ultrashort-chain and short-chain (C1 to C4) per- and polyfluorinated substances in potable and non-potable waters. J. Chromatogr. Open 4 (100098) (2023) <a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 537.1, Determination of selected per- and polyfluorinated alkyl substances in drinking water by solid phase extraction and liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), November 2018. <a href=\"https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 533, Determination of per- and polyfluoroalkyl substances in drinking water by isotope dilution anion exchange solid phase extraction and liquid chromatography\/tandem mass spectrometry, November 2019. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 1633A, Analysis of per- and polyfluoroalkyl substances (pfas) in aqueous, solid, biosolids, and tissue samples by LC-MS\/MS, December 2024. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf\" target=\"_blank\" rel=\"noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-45 (OTM-45), Measurement of selected per- and polyfluorinated alkyl substances from stationary sources, January 13, 2021. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 8327, Per- and polyfluoroalkyl substances (PFAS) by liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), July 2021. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Department of Agriculture, Food Safety and Inspection Service, Chemistry Laboratory Guidebook, CLG-PFAS 2.04, Screening, determination, and confirmation of PFAS by UHPLC-MS-MS, February 28, 2023. <a href=\"https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Centers for Disease Control and Prevention,<br>&nbsp;CDC 6304.09, Perfluoroalkyl and polyfluoroalkyl substances, February 2019. <a href=\"https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf<\/a><\/li>\n\n\n\n<li>U.S. Food and Drug Administration, FDA C-010.02, Determination of 30 per and polyfluoroalkyl substances (PFAS) in food and feed using liquid chromatography-tandem mass spectrometry (LC-MS\/MS), April 12, 2024. <a href=\"https:\/\/www.fda.gov\/media\/131510\/download\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fda.gov\/media\/131510\/download<\/a> &nbsp;&nbsp;<\/li>\n\n\n\n<li>DIN EN 17892, Water quality-Determination of the sum of perfluorinated substances (Sum of PFAS) in drinking water &#8211; Method using liquid chromatography\/mass spectrometry (LC\/MS), September 2021.<\/li>\n\n\n\n<li>DIN 38407-42, German standard methods for the examination of water, waste water and sludge-Jointly determinable substances (group F)-Part 42: determination of selected polyfluorinated compounds (PFC) in water-Method using high performance liquid chromatography and mass spectrometric detection (HPLC\/MS-MS)after solid-liquid extraction (F 42), March 2011.<\/li>\n\n\n\n<li>ISO 21675:2019, Water quality\u2014Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water\u2014Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS\/MS), 2019. <a href=\"https:\/\/www.iso.org\/standard\/71338.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.iso.org\/standard\/71338.html<\/a><\/li>\n\n\n\n<li>ASTM D7968-23, Standard test method for determination of polyfluorinated compounds in soil by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), November 6, 2023.<br>&nbsp;<a href=\"https:\/\/www.astm.org\/d7968-23.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7968-23.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D7979-20, Standard test method for determination of per- and polyfluoroalkyl substances in water, sludge, influent, effluent, and wastewater by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), September 3, 2020. <a href=\"https:\/\/www.astm.org\/d7979-20.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7979-20.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D8421-22, Standard test method for determination of per- and polyfluoroalkyl substances (PFAS) in aqueous matrices by co-solvation followed by liquid chromatography tandem mass spectrometry (LC\/MS\/MS) <a href=\"https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/discover.restek.com\/articles\/evar4305\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-50, OTM-50, Sampling and analysis of volatile fluorinated compounds from stationary sources using passivated stainless-steel canisters, January 2025. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf<\/a><\/li>\n<\/ol>\n\n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col,.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col{flex-direction:column;}.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column104563_7cbb5d-28{position:relative;}@media all and (max-width: 1024px){.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column104563_7cbb5d-28 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column104563_7cbb5d-28 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id104563_db1bb5-cf > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id104563_db1bb5-cf > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id104563_db1bb5-cf > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id104563_db1bb5-cf{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id104563_db1bb5-cf > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id104563_db1bb5-cf > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id104563_db1bb5-cf > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id104563_db1bb5-cf > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id104563_db1bb5-cf alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column104563_daea0c-e0 > .kt-inside-inner-col,.kadence-column104563_daea0c-e0 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column104563_daea0c-e0 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column104563_daea0c-e0 > .kt-inside-inner-col{flex-direction:column;}.kadence-column104563_daea0c-e0 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column104563_daea0c-e0 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column104563_daea0c-e0{position:relative;}@media all and (max-width: 1024px){.kadence-column104563_daea0c-e0 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column104563_daea0c-e0 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column104563_daea0c-e0\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03, .wp-block-kadence-advancedheading.kt-adv-heading104563_b99cf5-03[data-kb-block=\"kb-adv-heading104563_b99cf5-03\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading104563_b99cf5-03 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading104563_b99cf5-03\"><span class=\"kb-adv-text-inner\">Fragen zu Ihrer PFAS-Analyse?<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-c03aeb54e1bad990e850ee15e8b3a4f9 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">Von der Methodenauswahl bis zur Produktempfehlung \u2013 unsere PFAS-Experten unterst\u00fctzen Sie dabei, komplexe Workflows sicher zu meistern und pr\u00e4zise, zuverl\u00e4ssige Ergebnisse zu erzielen.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns104563_5e8c2f-95{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns104563_5e8c2f-95 .kt-button{font-weight:normal;font-style:normal;}.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns104563_5e8c2f-95 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns104563_5e8c2f-95\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn104563_d01e35-ca.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn104563_d01e35-ca.kb-button:hover .kb-svg-icon-wrap, .kb-btn104563_d01e35-ca.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn104563_d01e35-ca.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn104563_d01e35-ca kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/explore.restek.com\/PFAS-DE\" target=\"_blank\" rel=\"noopener\"><span class=\"kt-btn-inner-text\"><strong>PFAS-Experten kontaktieren<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{display:flex;}.kadence-column60360_76cebe-c5{max-width:650px;margin-left:auto;margin-right:auto;}.wp-block-kadence-column.kb-section-dir-horizontal:not(.kb-section-md-dir-vertical)>.kt-inside-inner-col>.kadence-column60360_76cebe-c5{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{padding-top:var(--global-kb-spacing-md, 2rem);padding-right:var(--global-kb-spacing-md, 2rem);padding-bottom:var(--global-kb-spacing-md, 2rem);padding-left:var(--global-kb-spacing-md, 2rem);}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col,.kadence-column60360_76cebe-c5 > .kt-inside-inner-col:before{border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > *, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{background-image:url('https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-background-texture.jpg');background-size:cover;background-position:center center;background-attachment:scroll;background-repeat:no-repeat;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60360_76cebe-c5{position:relative;}@media all and (min-width: 1025px){.wp-block-kadence-column.kb-section-dir-horizontal>.kt-inside-inner-col>.kadence-column60360_76cebe-c5{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}}@media all and (max-width: 1024px){.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}}@media all and (min-width: 768px) and (max-width: 1024px){.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > *, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}@media all and (max-width: 767px){.wp-block-kadence-column.kb-section-sm-dir-vertical:not(.kb-section-sm-dir-horizontal):not(.kb-section-sm-dir-specificity)>.kt-inside-inner-col>.kadence-column60360_76cebe-c5{max-width:650px;-webkit-flex:1;flex:1;margin-left:auto;margin-right:auto;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;justify-content:flex-start;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > *, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60360_76cebe-c5 > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60360_76cebe-c5 > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60360_76cebe-c5 kb-section-dir-horizontal\"><div class=\"kt-inside-inner-col\"><style>.kadence-column60360_b33a29-84 > .kt-inside-inner-col{display:flex;}.kadence-column60360_b33a29-84 > .kt-inside-inner-col,.kadence-column60360_b33a29-84 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column60360_b33a29-84 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_b33a29-84 > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column60360_b33a29-84{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_b33a29-84 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60360_b33a29-84{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column60360_b33a29-84{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column60360_b33a29-84{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_b33a29-84 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60360_b33a29-84\"><div class=\"kt-inside-inner-col\">\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-00265d7f2ebf110a1a5626166e5b66da wp-block-paragraph\" style=\"margin-top:0px;margin-bottom:0px;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;font-size:23px\"><strong>PFAS-Analyse leicht gemacht<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-21938156f08c1570d025043b86237d39 wp-block-paragraph\">Von der Produktauswahl bis zu Expertenleitf\u00e4den \u2013 alles, was Ihr Workflow braucht, an einem Ort.<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns60360_b500e8-76{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns60360_b500e8-76 .kt-button{font-weight:normal;font-style:normal;}.kt-btns60360_b500e8-76 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60360_b500e8-76 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns60360_b500e8-76\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top-color:#61b522;border-top-style:solid;border-right-color:#61b522;border-right-style:solid;border-bottom-color:#61b522;border-bottom-style:solid;border-left-color:#61b522;border-left-style:solid;margin-right:var(--global-kb-spacing-xs, 1rem);}.wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button:not(.specificity):not(.extra-specificity){text-decoration:none;}.kb-btn60360_1e6239-38.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn60360_1e6239-38.kb-button:hover .kb-svg-icon-wrap, .kb-btn60360_1e6239-38.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button:focus{color:#61b522;background:#0d507d;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button{border-top-color:#61b522;border-top-style:solid;border-right-color:#61b522;border-right-style:solid;border-bottom-color:#61b522;border-bottom-style:solid;border-left-color:#61b522;border-left-style:solid;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn60360_1e6239-38.kb-button{border-top-color:#61b522;border-top-style:solid;border-right-color:#61b522;border-right-style:solid;border-bottom-color:#61b522;border-bottom-style:solid;border-left-color:#61b522;border-left-style:solid;}}<\/style><a class=\"kb-button kt-button button kb-btn60360_1e6239-38 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn\" href=\"https:\/\/discover.restek.com\/pfas-analysis\/\"><span class=\"kt-btn-inner-text\"><strong>PFAS Portal entdecken<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{display:flex;}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col,.kadence-column60360_4ad42e-fc > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column60360_4ad42e-fc{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60360_4ad42e-fc{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column60360_4ad42e-fc{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column60360_4ad42e-fc{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60360_4ad42e-fc > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60360_4ad42e-fc\"><div class=\"kt-inside-inner-col\">\n<figure class=\"wp-block-image size-large has-custom-border\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg\" alt=\"\" class=\"wp-image-95824\" style=\"border-style:none;border-width:0px;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-300x200.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-768x512.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1536x1025.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-2048x1366.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Dieser methodenbasierte Leitfaden erleichtert die Suche nach geeignetem Laborbedarf f\u00fcr die PFAS-Analyse, sodass Sie genaue Daten generieren und die Methodenanforderungen erf\u00fcllen k\u00f6nnen. <\/p>\n","protected":false},"author":11,"featured_media":6610,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[2782],"industries-application":[2223,2226,2236,2238,2231,2234,2235,2232,2230],"post-badge":[],"resource-type":[],"product-library":[2507,2482],"resource-technique":[],"ppma_author":[414],"class_list":["post-60360","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","tag-pfas","industries-application-klinisch","industries-application-klinische-toxikologie","industries-application-lebensmittel-getranke","industries-application-lebensmittelsicherheit","industries-application-luftprufung","industries-application-pfas-analyse","industries-application-testung-von-boden-sediment-organismen","industries-application-trinkwasser-abwasseruntersuchungen","industries-application-umweltbereich","product-library-flussige-referenzstandards","product-library-referenzstandards"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"post_tag":[{"value":2782,"label":"PFAS"}],"industries-application":[{"value":2223,"label":"Klinisch"},{"value":2226,"label":"Klinische Toxikologie"},{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"},{"value":2238,"label":"Lebensmittelsicherheit"},{"value":2231,"label":"Luftpr\u00fcfung"},{"value":2234,"label":"PFAS Analyse"},{"value":2235,"label":"Testung von Boden, Sediment, Organismen"},{"value":2232,"label":"Trinkwasser- und Abwasseruntersuchungen"},{"value":2230,"label":"Umweltbereich"}],"product-library":[{"value":2507,"label":"Fl\u00fcssige Referenzstandards"},{"value":2482,"label":"Referenzstandards"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAR3498-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":787,"category_count":511,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":[{"term_id":2782,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2782,"taxonomy":"post_tag","description":"","parent":0,"count":124,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60360","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=60360"}],"version-history":[{"count":33,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60360\/revisions"}],"predecessor-version":[{"id":102555,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/60360\/revisions\/102555"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/6610"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=60360"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=60360"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=60360"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=60360"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=60360"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=60360"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=60360"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=60360"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=60360"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}