{"id":75639,"date":"2024-03-29T17:46:00","date_gmt":"2024-03-29T17:46:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=75639"},"modified":"2026-01-08T14:25:38","modified_gmt":"2026-01-08T14:25:38","slug":"no-pressure-low-pressure-gas-chromatography-analysis-of-cannabis-terpenes","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/blogs\/no-pressure-low-pressure-gas-chromatography-analysis-of-cannabis-terpenes\/","title":{"rendered":"No pressure! Low-Pressure Gas Chromatography Analysis of Cannabis Terpenes"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Terpenes are responsible for the characteristic aromas and flavors of different natural and consumer products. They produce a wide range of scents, from citrusy and fruity to earthy and piney. Terpenes can be extracted from plant materials and used in various products, including essential oils, aromatherapy, and even as flavor additives in food and beverages. They are also an important part of cannabis&#8217; aroma and flavor.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The specific terpene profile of a cannabis strain is influenced by its genetics and growing conditions. Different strains can have vastly different terpene profiles. In the cannabis industry, terpene testing is often conducted alongside cannabinoid testing to provide consumers with information about a strain&#8217;s terpene content.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In the analysis of cannabis terpenes, utilizing a conventional GC-MS approach is a commonplace technique. However, analysts can harness a powerful technique to reduce run times, increase sample throughput, and reduce lab costs: low-pressure gas chromatography (LPGC). LPGC is a technique that employs sub-ambient pressure conditions to create a vacuum system, while using a short, narrow restrictor column at the injection port, connected by a union to the actual analytical column. Generally, the analytical column will be 0.32 mm or wider. In this case, the analytical column of choice was the Rxi-624Sil MS column. This column is a great phase choice for this analysis because it is low-bleed, selective, and efficient.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The speed of analysis and increased sample volume are the major benefits of LPGC. Peak shapes are comparable to conventional GC-MS, with LPGC peak heights often being higher. The principal drawback of using LPGC is decreased separation efficiency. This can be problematic in the case of closely eluting isobars (compounds that cannot be resolved using MS spectra).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1236.png\" alt=\"Cannabis Terpenes Standard #1 and #2 on LPGC Rxi-624Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1236<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12 peak-50\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Pinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-56-8\/\u03b1-Pinene\" target=\"_blank\" rel=\"noopener\">\u03b1-Pinene<\/a><\/td><td class=\"oth\">3.309<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Camphene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79-92-5\/Camphene\" target=\"_blank\" rel=\"noopener\">Camphene<\/a><\/td><td class=\"oth\">3.438<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Myrcene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-35-3\/\u03b2-Myrcene\" target=\"_blank\" rel=\"noopener\">\u03b2-Myrcene<\/a><\/td><td class=\"oth\">3.627<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Pinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/127-91-3\/\u03b2-Pinene\" target=\"_blank\" rel=\"noopener\">\u03b2-Pinene<\/a><\/td><td class=\"oth\">3.639<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b4-3-Carene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13466-78-9\/\u03b4-3-Carene\" target=\"_blank\" rel=\"noopener\">\u03b4-3-Carene<\/a><\/td><td class=\"oth\">3.810<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Terpinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-86-5\/\u03b1-Terpinene\" target=\"_blank\" rel=\"noopener\">\u03b1-Terpinene<\/a><\/td><td class=\"oth\">3.885<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Ocimene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1002-35-3\/\u03b1-Ocimene\" target=\"_blank\" rel=\"noopener\">\u03b1-Ocimene<\/a><\/td><td class=\"oth\">3.969<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for D-Limonene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5989-27-5\/D-Limonene\" target=\"_blank\" rel=\"noopener\">D-Limonene<\/a><\/td><td class=\"oth\">3.969<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Cymene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-87-6\/p-Cymene\" target=\"_blank\" rel=\"noopener\">p-Cymene<\/a><\/td><td class=\"oth\">3.996<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Ocimene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13877-91-3\/\u03b2-Ocimene\" target=\"_blank\" rel=\"noopener\">\u03b2-Ocimene<\/a><\/td><td class=\"oth\">4.074<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Eucalyptol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-82-6\/Eucalyptol\" target=\"_blank\" rel=\"noopener\">Eucalyptol<\/a><\/td><td class=\"oth\">4.074<\/td><td class=\"oth\">5<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-6 col-12 peak-50\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b3-Terpinene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-85-4\/\u03b3-Terpinene\" target=\"_blank\" rel=\"noopener\">\u03b3-Terpinene<\/a><\/td><td class=\"oth\">4.197<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terpinolene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/586-62-9\/Terpinolene\" target=\"_blank\" rel=\"noopener\">Terpinolene<\/a><\/td><td class=\"oth\">4.468<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linalool\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-70-6\/Linalool\" target=\"_blank\" rel=\"noopener\">Linalool<\/a><\/td><td class=\"oth\">4.882<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopulegol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/89-79-2\/Isopulegol\" target=\"_blank\" rel=\"noopener\">Isopulegol<\/a><\/td><td class=\"oth\">5.632<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Geraniol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-24-1\/Geraniol\" target=\"_blank\" rel=\"noopener\">Geraniol<\/a><\/td><td class=\"oth\">7.139<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-Caryophyllene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-44-5\/\u03b2-Caryophyllene\" target=\"_blank\" rel=\"noopener\">\u03b2-Caryophyllene<\/a><\/td><td class=\"oth\">7.989<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Humulene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6753-98-6\/\u03b1-Humulene\" target=\"_blank\" rel=\"noopener\">\u03b1-Humulene<\/a><\/td><td class=\"oth\">8.127<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\">Nerolidol 1<\/td><td class=\"oth\">8.373<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\">Nerolidol 2<\/td><td class=\"oth\">8.460<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Guaiol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/489-86-1\/Guaiol\" target=\"_blank\" rel=\"noopener\">Guaiol<\/a><\/td><td class=\"oth\">8.634<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Caryophyllene oxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1139-30-6\/Caryophyllene oxide\" target=\"_blank\" rel=\"noopener\">Caryophyllene oxide<\/a><\/td><td class=\"oth\">8.658<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Bisabolol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/515-69-5\/\u03b1-Bisabolol\" target=\"_blank\" rel=\"noopener\">\u03b1-Bisabolol<\/a><\/td><td class=\"oth\">8.826<\/td><td class=\"oth\">5<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">\u03b1-Ocimene and \u03b2-Ocimene have coeluted with D-Limonene and Eucalyptol, respectively.<\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>LPGC Rxi-624Sil MS (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/11804\" rel=\"noopener\">cat.# 11804<\/a>), includes Rxi-624Sil MS, 10 m, 0.32 mm ID, 1.8 \u03bcm w\/5 m, 0.15 mm ID Rxi restrictor connected via SilTite connector<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>Cannabis terpenes standard #1 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34095\" rel=\"noopener\">cat.# 34095<\/a>)<\/td><\/tr><tr><td><\/td><td>Cannabis terpenes standard #2 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34096\" rel=\"noopener\">cat.# 34096<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Isopropanol<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>25 \u00b5g\/mL (5 \u00b5g\/mL on column)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 5:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz, splitless, single taper inlet liner, 4.0 mm x 6.5 x 78.5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>55 &#176;C (hold 1 min) to 130 &#176;C at 30 &#176;C\/min (hold 3 min) to 280 &#176;C at 60 &#176;C\/min (hold 2 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>0.9 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Agilent 5975C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>1.50<\/td><td>35 &#8211; 280<\/td><td><\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>310 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>180 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>1.50  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The sample was in a 2 mL short-cap, screw-thread vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) and capped with a short-cap, screw-vial closure (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24495\" rel=\"noopener\">cat.# 24495<\/a>).<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34095<\/li><li>34096<\/li><li>23303<\/li><li>11804<\/li><li>21143<\/li><li>24495<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1236.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">The conventional GC-MS run takes about 16 minutes with the latest compound eluting around 15 minutes. With LPGC, analysis time drops to 11 minutes. An analyst can note by using this method, there is an opportunity for great time and helium savings (as the method is shorter and operating under lower flow conditions.)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LPGC provided excellent peaks for those compounds that were fully resolved. Peaks were taller than those on the conventional chromatogram comparison. Of the compounds in the standard, beta-pinene, beta-myrcene, D-limonene, p-cymene, guaiol, and caryophyllene oxide were the compounds which suffered the most from the lack of separation efficiency. Beta-pinene and beta-myrcene coelution is the most concerning due to being isobars and very abundant in cannabis samples. Ocimene 1 and 2 were not detected in the initial run, however an analyst may identify their presence through mass spectrometry confirmation. Ocimene 1 and 2 seem to coelute with D-limonene and eucalyptol, respectively.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Because of the nature of terpenes in cannabis analysis, a higher chromatographic efficiency is paramount to high-quality results. As part of the same class of compounds, the spectra of terpenes can mimic each other very closely. An analyst could be faced with issues differentiating and quantitating compounds even after extracting chromatogram ions. LPGC is great for fast analysis. Analysts may find that LPGC is a great screening tool for cannabis samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Below is a comparison of conventional GC-MS analysis conditions of our cannabis terpenes standards with the LPGC analysis conditions.<\/p>\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr style=\"text-align: center; background-color: #002060; color: #ffffff;\">\n<td colspan=\"2\"><strong>LPGC Method \u2013 11 min<\/strong><\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Agilent 7890A GC<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Oven<\/td>\n<td>\n<table style=\"border-style: none;\">\n<tbody>\n<tr>\n<td style=\"text-align: left;\">\u00b0C\/min<\/td>\n<td>Hold (\u00b0C)<\/td>\n<td>Hold (min)<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td style=\"text-align: left;\">\u00a055<\/td>\n<td>1<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td>130<\/td>\n<td>3<\/td>\n<\/tr>\n<tr>\n<td>60<\/td>\n<td>280<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Inlet (Split\/Splitless)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Liner<\/td>\n<td>Topaz, Single Taper, 4.0 mm x 6.5 x 78.5 (Catalog #: 23303)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Temperature<\/td>\n<td>280\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mode<\/td>\n<td>Split<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Split Ratio<\/td>\n<td>5:1<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Analytical Column<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Column<\/td>\n<td>LPGC Rxi-624Sil MS (Catalog #: 11804), includes Rxi-624Sil MS, 10 m, 0.32 mm ID, 1.8 \u03bcm w\/5 m, 0.15 mm ID Rxi restrictor connected via SilTite connector<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mode<\/td>\n<td>Constant Flow<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Flow<\/td>\n<td>0.9 mL\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Transfer Line Temperature<\/td>\n<td>310\u00b0C<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Agilent 5975C MSD<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Acquisition Mode<\/td>\n<td>Scan<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Gain Factor<\/td>\n<td>1<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Scan Parameters<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Source Temperature<\/td>\n<td>330<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Quad Temperature<\/td>\n<td>180<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Solvent Delay<\/td>\n<td>1.50 min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mass Range<\/td>\n<td>35-280 amu<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Scan Speed<\/td>\n<td>1,562 [N=2]<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Chemicals and Reagents<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\" rowspan=\"2\">Analyte<\/td>\n<td>Cannabis Terpenes Standard #1 (Catalog #: 34095)<\/td>\n<\/tr>\n<tr>\n<td>Cannabis Terpenes Standard #2 (Catalog #: 34096)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Source<\/td>\n<td>Restek<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Solvent (Standard Preparation)<\/td>\n<td>Isopropanol<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Sample Concentration<\/td>\n<td>25 \u00b5g\/mL (5 \u00b5g\/mL on column)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody>\n<tr style=\"text-align: center; background-color: #ffc000;\">\n<td colspan=\"2\"><strong>Conventional GCMS Method \u2013 16 min<\/strong><\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Agilent 7890A GC<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Oven<\/td>\n<td>\n<table style=\"border-style: none;\">\n<tbody>\n<tr>\n<td style=\"text-align: left;\">\u00b0C\/min<\/td>\n<td>Hold (\u00b0C)<\/td>\n<td>Hold (min)<\/td>\n<\/tr>\n<tr>\n<td>\u00a0<\/td>\n<td style=\"text-align: left;\">\u00a055<\/td>\n<td>0<\/td>\n<\/tr>\n<tr>\n<td>25<\/td>\n<td>130<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>30<\/td>\n<td>280<\/td>\n<td>2<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Inlet (Split\/Splitless)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Liner<\/td>\n<td>Topaz, Single Taper, 4.0 mm x 6.5 x 78.5 (Catalog #: 23303)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Temperature<\/td>\n<td>280\u00b0C<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mode<\/td>\n<td>Split<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Split Ratio<\/td>\n<td>5:1<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Analytical Column<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Column<\/td>\n<td>Rxi-624Sil 30m x 0.25mmID x 1.4\u00b5m (Catalog #: 13868)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mode<\/td>\n<td>Constant Flow<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Flow<\/td>\n<td>1.5 mL\/min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Transfer Line Temperature<\/td>\n<td>310\u00b0C<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Agilent 5975C MSD<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Acquisition Mode<\/td>\n<td>Scan<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Gain Factor<\/td>\n<td>1<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #ecf0f1;\">\n<td colspan=\"2\">Scan Parameters<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Source Temperature<\/td>\n<td>330<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Quad Temperature<\/td>\n<td>180<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Solvent Delay<\/td>\n<td>5.00 min<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Mass Range<\/td>\n<td>35-280 amu<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Scan Speed<\/td>\n<td>1,562 [N=2]<\/td>\n<\/tr>\n<tr style=\"text-align: center; background-color: #00b0f0;\">\n<td colspan=\"2\"><strong>Chemicals and Reagents<\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\" rowspan=\"2\">Analyte<\/td>\n<td>Cannabis Terpenes Standard #1 (Catalog #: 34095)<\/td>\n<\/tr>\n<tr>\n<td>Cannabis Terpenes Standard #2 (Catalog #: 34096)<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Source<\/td>\n<td>Restek<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Solvent (Standard Preparation)<\/td>\n<td>Isopropanol<\/td>\n<\/tr>\n<tr>\n<td style=\"background-color: #ccecff;\">Sample Concentration<\/td>\n<td>25 \u00b5g\/mL (5 \u00b5g\/mL on column)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Erw\u00e4hnte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/11804\">                                Art.-Nr. 11804                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rxi-624Sil MS S\u00e4ulenkit, 0.32 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/11804\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23303\">                                Art.-Nr. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, f\u00fcr Agilent GCs, mit Quarzwolle, Premium-Deaktivierung, 5er Pack<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23303\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13868\">                                Art.-Nr. 13868                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-624Sil MS GC Kapillars\u00e4ule, 30 m, 0.25 mm ID, 1.40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/13868\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34095\">                                Art.-Nr. 34095                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cannabis Terpenes-Standard Nr. 1 2500 \u00b5g\/mL, Isopropanol, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34095\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34096\">                                Art.-Nr. 34096                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Cannabis Terpenes-Standard Nr. 2 2500 \u00b5g\/mL, Isopropanol, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/34096\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/21143\">                                Art.-Nr. 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap-Vial mit graduiertem Markierungsfeld, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (nur Vial), braun, 1000er Pack<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/21143\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Terpenes are responsible for the characteristic aromas and flavors of different natural and consumer products. They produce a wide range of scents, from citrusy and fruity to earthy and piney. Terpenes can be extracted from plant materials and used in various products, including essential oils, aromatherapy, and even as flavor additives in food and beverages&#8230;.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-75639","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/de\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":458,"filter":"raw","cat_ID":9,"category_count":458,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/75639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=75639"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/75639\/revisions"}],"predecessor-version":[{"id":75750,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/75639\/revisions\/75750"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=75639"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=75639"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=75639"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=75639"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=75639"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=75639"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=75639"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=75639"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=75639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}