{"id":76461,"date":"2022-08-29T00:00:00","date_gmt":"2022-08-29T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=76461"},"modified":"2026-01-28T17:38:37","modified_gmt":"2026-01-28T17:38:37","slug":"speed-up-semivolatiles-analysis-without-sacrificing-critical-separations-using-the-ezgc-method-translator-and-a-narrow-bore-rxi-svocms-column","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/blogs\/gnbl5538\/speed-up-semivolatiles-analysis-without-sacrificing-critical-separations-using-the-ezgc-method-translator-and-a-narrow-bore-rxi-svocms-column","title":{"rendered":"Speed Up Semivolatiles Analysis Without Sacrificing Critical Separations Using the EZGC Method Translator and a Narrow Bore Rxi-SVOCms Column"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">My last blog highlighted the importance of the\u00a0<a href=\"https:\/\/discover.restek.com\/blogs\/gnbl5506\/improved-indeno123-cdpyrene-dibenzahanthracene-separation-on-the-new-rxi-svocms-column\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/blogs\/gnbl5506\/improved-indeno123-cdpyrene-dibenzahanthracene-separation-on-the-new-rxi-svocms-column\">indeno[123-cd]pyrene-dibenz[ah]anthracene<\/a> separation with a promise to improve runtimes without sacrificing critical separations. More importantly, we maintain the same elution profile of the original 16-minute run. The EZGC method translator conveniently translates the acquisition parameters for one column format to another while preserving the analyte elution temperatures and relative retention times.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Using the parameters from <a href=\"https:\/\/www.restek.com\/chromatogram-detail\/GC_EV1604\" target=\"_blank\" rel=\"noopener\">GC_EV1604<\/a>, the 8270 MegaMix chromatogram on a 30 m x 0.25 mm x 0.25 \u00b5m Rxi-SVOCms column (cat #16623), we can use the EZGC method translator to generate acquisition parameters for a 20 m x 0.15 mm x 0.15 \u00b5m Rxi-SVOCms column (cat #46616). The <a href=\"https:\/\/ez.restek.com\/\" target=\"_blank\" rel=\"noopener\"><em>EZ<\/em>GC Method Translator<\/a> interface is shown in Figure 1. It is important to select \u2018Translate\u2019 in the <strong>Results<\/strong> section; this insures an accurate flow translation.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1<\/strong> &#8211; Translation from a 30 m x 0.25 mm x 0.25 \u00b5m column to a 20 m x 0.15 mm<em> x 0.15 \u00b5m column using the EZGC Method Translator<\/em><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_1f02ec-fb .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_1f02ec-fb size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"466\" height=\"682\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01.png\" alt=\"\" class=\"kb-img wp-image-78649\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01.png 466w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-01-205x300.png 205w\" sizes=\"auto, (max-width: 466px) 100vw, 466px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Completing the analysis in 70% of the time while maintaining the elution profile sounds too good to be true, but it\u2019s possible because the 30 m x 0.25 mm x 0.25 \u00b5m and 20 m x 0.15 mm x 0.15 \u00b5m columns used have very similar efficiencies. Both columns have more than 130,000 plates (at least theoretically). Let\u2019s see how theory holds up under real testing conditions. Figures 2 and 3 are 8270 MegaMix chromatograms collected on the 30 m cat# 16623 and 20 m cat# 46616 Rxi-SVOCms columns respectively.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2<\/strong> &#8211; 8270 MegaMix on the 30 m x 0.25 mm x 0.25 \u00b5m Rxi-SVOCms column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_97e611-a8:not(.kb-image-is-ratio-size) .kb-img, .kb-image76461_97e611-a8.kb-image-is-ratio-size{padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image76461_97e611-a8 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_97e611-a8 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1265\" height=\"720\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03.png\" alt=\"\" class=\"kb-img wp-image-78643\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03.png 1265w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-300x171.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-1024x583.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-03-768x437.png 768w\" sizes=\"auto, (max-width: 1265px) 100vw, 1265px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3<\/strong> &#8211; 8270 MegaMix on the 20 m x 0.15 mm x 0.15 \u00b5m Rxi-SVOCms column<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_5bc94a-31:not(.kb-image-is-ratio-size) .kb-img, .kb-image76461_5bc94a-31.kb-image-is-ratio-size{padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image76461_5bc94a-31 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_5bc94a-31 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1259\" height=\"726\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a.png\" alt=\"\" class=\"kb-img wp-image-78637\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a.png 1259w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-300x173.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-1024x590.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-04a-768x443.png 768w\" sizes=\"auto, (max-width: 1259px) 100vw, 1259px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Even more impressive, the elution profile and critical separations shown in Figure 3 are very close to those predicted by the Pro <em>EZ<\/em>GC chromatogram modeler (Figure 4). Take note of the oven program required for this analysis (35.6\u1d52C\/min to 285\u1d52C and 28.5\u1d52C\/min to 330\u1d52C); 110v Agilent GCs may require the GC Accelerator oven insert kit (cat# 23849) to reach these rates consistently. We recommend using a 20:1 split with column IDs \u2264 0.18 mm ID. This yields equivalent performance to a 10:1 split on a 0.25 mm ID column using the same inlet liner and calibration standards.&nbsp; <span style=\"color: #ff0000;\">The 2 times higher split ratio will also give you 2 times less column contamination which may extend lifetime when comparing columns when the same number of samples are analyzed.<\/span><\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4<\/strong> &#8211; 8270 Appendix IX calibration kit modeled on Rxi-SVOCms column cat# 46616 using the Pro EZGC Chromatogram Modeler.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_3df10c-18:not(.kb-image-is-ratio-size) .kb-img, .kb-image76461_3df10c-18.kb-image-is-ratio-size{padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image76461_3df10c-18 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_3df10c-18 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1142\" height=\"508\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05.png\" alt=\"\" class=\"kb-img wp-image-78631\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05.png 1142w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-300x133.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-1024x456.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-05-768x342.png 768w\" sizes=\"auto, (max-width: 1142px) 100vw, 1142px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Sacrificing a little efficiency (about 15,000 plates), we can translate to the 20m x 0.18 mm x 0.18 \u00b5m Rxi-SVOCms column (cat# 46602) using the EZGC method translator (Figure 5). This results in a benzo[ghi]perylene elution time that is 5.6 minutes earlier than what we see on the 30m Rxi-SVOCms column (Figure 6). The GC accelerator kit is almost certainly required for 110v Agilent GCs at these higher ramp rates.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5<\/strong> &#8211; Translation from a 30 m x 0.25 mm x 0.25 \u00b5m column format to 20 m x 0.18 mm x 0.18 mm using the EZGC Method Translator.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_5a6357-0a:not(.kb-image-is-ratio-size) .kb-img, .kb-image76461_5a6357-0a.kb-image-is-ratio-size{padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image76461_5a6357-0a .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_5a6357-0a size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"470\" height=\"686\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-02.png\" alt=\"\" class=\"kb-img wp-image-78625\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-02.png 470w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-02-206x300.png 206w\" sizes=\"auto, (max-width: 470px) 100vw, 470px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6<\/strong> &#8211; 8270 MegaMix chromatogram acquired on a 20 m x 0.18 mm x 0.18 \u00b5m Rxi-SVOCms column (cat# 46602)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image76461_18fd12-71:not(.kb-image-is-ratio-size) .kb-img, .kb-image76461_18fd12-71.kb-image-is-ratio-size{padding-bottom:var(--global-kb-spacing-xs, 1rem);}.kb-image76461_18fd12-71 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image76461_18fd12-71 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1282\" height=\"644\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06.png\" alt=\"\" class=\"kb-img wp-image-78619\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06.png 1282w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-300x151.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-1024x514.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-speed-up-your-semivolatiles-analysis-without-sacrificing-critical-separations-06-768x386.png 768w\" sizes=\"auto, (max-width: 1282px) 100vw, 1282px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Combining the GC Accelerator with a 208v (or higher) fast ramping oven allows you to use speed optimized flow translations for semivolatiles analysis that takes less than 10 minutes, but that topic deserves its own article.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Erw\u00e4hnte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/16623\">                                Art.-Nr. 16623                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Kapillars\u00e4ule, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/16623\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23849\">                                Art.-Nr. 23849                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC Accelerator-Ofeneinsatz-Kit, f\u00fcr Agilent 5890, 6890, 7890 und 8890 GCs<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23849\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/46616\">                                Art.-Nr. 46616                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Kapillars\u00e4ule, 20 m, 0.15 mm ID, 0.15 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/46616\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/46602\">                                Art.-Nr. 46602                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rxi-SVOCms GC Kapillars\u00e4ule, 20 m, 0.18 mm ID, 0.18 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/46602\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Last time, I ended my explanation of the importance of the indeno[123-cd]pyrene-dibenz[ah]anthracene with a promise to show you how to cut 5 minutes from the analysis without sacrificing critical separations. More important, we maintain the same elution profile seen in the 16-minute run. The EZGC method translator conveniently translates the acquisition parameters for one column format to another while preserving the analyte elution temperatures and relative retention times.<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[584],"class_list":["post-76461","post","type-post","status-publish","format-standard","hentry","category-blogs"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/de\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":584,"user_id":0,"is_guest":1,"slug":"chris-rattray","display_name":"Chris Rattray","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Chris","last_name":"Rattray","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/76461","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=76461"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/76461\/revisions"}],"predecessor-version":[{"id":85626,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/76461\/revisions\/85626"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=76461"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=76461"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=76461"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=76461"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=76461"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=76461"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=76461"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=76461"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=76461"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}