{"id":86246,"date":"2026-01-19T19:42:04","date_gmt":"2026-01-19T19:42:04","guid":{"rendered":"https:\/\/discover.restek.com\/?p=86246"},"modified":"2026-05-27T17:45:08","modified_gmt":"2026-05-27T17:45:08","slug":"neue-wege-zur-effizienten-spurenanalyse-halbfluechtiger-verbindungen","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/evfa5253-de\/neue-wege-zur-effizienten-spurenanalyse-halbfluechtiger-verbindungen","title":{"rendered":"Neue Wege zur effizienten Spurenanalyse halbfl\u00fcchtiger Verbindungen"},"content":{"rendered":"\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Eine neue Dimension der Inertheit: Die innovative TriMax-Deaktivierung schafft einen bislang unerreichten, hochinerten Probenflussweg f\u00fcr eine Methode mit 150 Verbindungen \u2013 einschlie\u00dflich S\u00e4uren, Basen und neutraler Analyten.<\/li>\n\n\n\n<li>Methodenkonsolidierung ohne Kompromisse bei der Empfindlichkeit: Maximale Inertheit sorgt f\u00fcr exzellente Peakformen bei 150 halbfl\u00fcchtige Verbindungen und erm\u00f6glicht pg-Nachweisgrenzen in einer einzigen, konsolidierten Methode.<\/li>\n\n\n\n<li>150-Komponenten-Methode sofort nutzbar \u2013 oder in Sekunden angepasst: Nutzen Sie unseren kostenlosen virtuellen EZGC-Chromatogram-Modeler \u2013 ohne zeitintensive Laborarbeit.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-de\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE.png\" alt=\"\" class=\"wp-image-84593\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-de\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE.png\" alt=\"\" class=\"wp-image-84599\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Die Analyse halbfl\u00fcchtiger Verbindungen ist weltweit eine grundlegende Applikation in Umweltpr\u00fcflabors. Da sich halbfl\u00fcchtige Verbindungen in Zusammensetzung und Reaktivit\u00e4t stark unterscheiden, werden sie h\u00e4ufig auf unterschiedlichen S\u00e4ulen analysiert. K\u00f6nnte man diese Anwendungen auf einer einzigen S\u00e4ule zusammenf\u00fchren, lie\u00dfe sich der Analyseaufwand deutlich reduzieren. Ob das gelingt, entscheidet die Wirksamkeit der GC-S\u00e4ulendeaktivierung. Herk\u00f6mmliche Deaktivierungsverfahren sind meist auf bestimmte Verbindungsklassen optimiert und sto\u00dfen bei chemisch unterschiedlichen Analyten schnell an ihre Grenzen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mit der TriMax-Deaktivierungstechnologie hat Restek eine universell wirksame L\u00f6sung der n\u00e4chsten Generation entwickelt, die selbst bei Methoden mit bis zu 150 S\u00e4uren, Basen und neutralen Verbindungen eine unerreichte Systeminertheit bietet \u2013 nachweislich leistungsf\u00e4higer als Premium-S\u00e4ulen f\u00fchrender Mitbewerber [1]. Diese Technologie bildet die Grundlage aller RMX-S\u00e4ulen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eine k\u00fcrzlich ver\u00f6ffentlichte Studie zeigte, dass RMX-5Sil-MS-S\u00e4ulen \u00fcber ein breites Spektrum halbfl\u00fcchtiger Verbindungsklassen hinweg symmetrischere Peakformen liefern, sodass mehr Verbindungen die Datenanforderungen an Linearit\u00e4t und Wiederfindung erf\u00fcllen [2]. Die vorliegende Anwendung greift diese Ergebnisse auf und entwickelt sie weiter: Durch optimierte Analysebedingungen wurde die Methode auf 150 h\u00e4ufig untersuchte halbfl\u00fcchtige Verbindungen ausgeweitet, einschlie\u00dflich interner Standards und Surrogate (Abbildung 1).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Wie Abbildung 2 zeigt, liefern die RMX-5Sil-MS-S\u00e4ulen auch im Spurenbereich (0,1\u201310 pg on column) \u00fcber alle Verbindungsklassen hinweg \u00fcberzeugende chromatografische Ergebnisse. Das gilt f\u00fcr reaktive saure Verbindungen wie Pentachlorphenol und 2,4-Dinitrophenol ebenso wie f\u00fcr basische Analyten wie Pyridin und Benzidin. Gerade bei diesen Verbindungen ist die Einhaltung von Systemtauglichkeitskriterien oft kritisch. Zudem lassen sich mit der RMX-5Sil-MS-S\u00e4ule auch neutrale polyzyklische aromatische Kohlenwasserstoffe trennen, die sonst nur schwer aufzul\u00f6sen sind, wie etwa Benzo[b]- und Benzo[k]fluoranthen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Die konsolidierte Methode zur Spurenanalyse halbfl\u00fcchtiger Verbindungen basiert auf einer Analyten-Liste von 150 praxisrelevanten Verbindungen (Kat.-Nr. 31907) und zeigt wie effektiv die RMX-5Sil MS \u00fcber den gesamten Bereich ist. Mit dem kostenlosen EZGC Chromatogram Modeler von Restek entwickeln Sie daraus in wenigen Schritten eine Methode, die exakt auf Ihre Analytliste und Ihre bevorzugten S\u00e4ulendimensionen abgestimmt ist.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image86246_0f29cf-65 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image86246_0f29cf-65\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.restek.com\/c\/1484\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-1024x177.png\" alt=\"\" class=\"kb-img wp-image-91767\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-1024x177.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-300x52.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-768x133.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 1: <\/strong>Erweiterte Methode f\u00fcr die Analyse halbfl\u00fcchtiger Verbindungen im Spurenbereich, gezeigt f\u00fcr 150 halbfl\u00fcchtige Verbindungen, Surrogate und interne Standards bei 100 ppb (10 pg on-column)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.png\" alt=\"Semivolatiles on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1527<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Mass 1<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Collision energy 1<\/th><th style=\"text-align: center;width: 75px\">Mass 2<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><th style=\"text-align: center;width: 75px\">Collision energy 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dioxane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/123-91-1\/1,4-Dioxane\" target=\"_blank\" rel=\"noopener\">1,4-Dioxane<\/a><\/td><td class=\"oth\">2.71<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">28<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">28<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodimethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-75-9\/N-Nitrosodimethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodimethylamine<\/a><\/td><td class=\"oth\">3.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">74<\/td><td class=\"oth\">44<\/td><td class=\"oth\">6<\/td><td class=\"oth\">74<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/110-86-1\/Pyridine\" target=\"_blank\" rel=\"noopener\">Pyridine<\/a><\/td><td class=\"oth\">3.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">79<\/td><td class=\"oth\">52<\/td><td class=\"oth\">12<\/td><td class=\"oth\">52<\/td><td class=\"oth\">26<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methacrylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/97-63-2\/Ethyl methacrylate\" target=\"_blank\" rel=\"noopener\">Ethyl methacrylate<\/a><\/td><td class=\"oth\">3.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">69<\/td><td class=\"oth\">41<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">43<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Picoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/109-06-8\/2-Picoline\" target=\"_blank\" rel=\"noopener\">2-Picoline<\/a><\/td><td class=\"oth\">3.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomethylethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10595-95-6\/N-Nitrosomethylethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomethylethylamine<\/a><\/td><td class=\"oth\">4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">71<\/td><td class=\"oth\">6<\/td><td class=\"oth\">88<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66-27-3\/Methyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Methyl methanesulfonate<\/a><\/td><td class=\"oth\">4.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">80<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">80<\/td><td class=\"oth\">48<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">Acrylamine<\/td><td class=\"oth\">4.44<\/td><td class=\"oth\">10<\/td><td class=\"oth\">71<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">44<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/367-12-4\/2-Fluorophenol\" target=\"_blank\" rel=\"noopener\">2-Fluorophenol<\/a><\/td><td class=\"oth\">4.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">112<\/td><td class=\"oth\">92<\/td><td class=\"oth\">6<\/td><td class=\"oth\">92<\/td><td class=\"oth\">63<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodiethylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-18-5\/N-Nitrosodiethylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodiethylamine<\/a><\/td><td class=\"oth\">4.94<\/td><td class=\"oth\">10<\/td><td class=\"oth\">102<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">102<\/td><td class=\"oth\">44<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl methanesulfonate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-50-0\/Ethyl methanesulfonate\" target=\"_blank\" rel=\"noopener\">Ethyl methanesulfonate<\/a><\/td><td class=\"oth\">5.38<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzaldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-52-7\/Benzaldehyde\" target=\"_blank\" rel=\"noopener\">Benzaldehyde<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol-d6\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13127-88-3\/Phenol-d6\" target=\"_blank\" rel=\"noopener\">Phenol-d6<\/a><\/td><td class=\"oth\">6.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">99<\/td><td class=\"oth\">71<\/td><td class=\"oth\">8<\/td><td class=\"oth\">71<\/td><td class=\"oth\">42<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-95-2\/Phenol\" target=\"_blank\" rel=\"noopener\">Phenol<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">94<\/td><td class=\"oth\">39<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-53-3\/Aniline\" target=\"_blank\" rel=\"noopener\">Aniline<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-01-7\/Pentachloroethane\" target=\"_blank\" rel=\"noopener\">Pentachloroethane<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">132<\/td><td class=\"oth\">14<\/td><td class=\"oth\">167<\/td><td class=\"oth\">95<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for bis-(2-Chloroethyl)ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-44-4\/bis-(2-Chloroethyl)ether\" target=\"_blank\" rel=\"noopener\">bis-(2-Chloroethyl)ether<\/a><\/td><td class=\"oth\">6.18<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-57-8\/2-Chlorophenol\" target=\"_blank\" rel=\"noopener\">2-Chlorophenol<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">64<\/td><td class=\"oth\">14<\/td><td class=\"oth\">128<\/td><td class=\"oth\">63<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Decane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/124-18-5\/Decane\" target=\"_blank\" rel=\"noopener\">Decane<\/a><\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">71<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/541-73-1\/1,3-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene-d4\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3855-82-1\/1,4-Dichlorobenzene-d4\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene-d4<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">150<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><td class=\"oth\">150<\/td><td class=\"oth\">76<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-46-7\/1,4-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.63<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><td class=\"oth\">146<\/td><td class=\"oth\">75<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl alcohol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-51-6\/Benzyl alcohol\" target=\"_blank\" rel=\"noopener\">Benzyl alcohol<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">79<\/td><td class=\"oth\">12<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-50-1\/1,2-Dichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dichlorobenzene<\/a><\/td><td class=\"oth\">6.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">111<\/td><td class=\"oth\">12<\/td><td class=\"oth\">111<\/td><td class=\"oth\">50<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-13-6\/Indene\" target=\"_blank\" rel=\"noopener\">Indene<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">115<\/td><td class=\"oth\">89<\/td><td class=\"oth\">16<\/td><td class=\"oth\">116<\/td><td class=\"oth\">89<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-48-7\/2-Methylphenol\" target=\"_blank\" rel=\"noopener\">2-Methylphenol<\/a><\/td><td class=\"oth\">7.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">8<\/td><td class=\"oth\">108<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,2&amp;apos;-oxybis(1-chloropropane)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/108-60-1\/2,2&amp;apos;-oxybis(1-chloropropane)\" target=\"_blank\" rel=\"noopener\">2,2&#8242;-oxybis(1-chloropropane)<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">45<\/td><td class=\"oth\">6<\/td><td class=\"oth\">77<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopyrrolidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/930-55-2\/N-Nitrosopyrrolidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopyrrolidine<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">10<\/td><td class=\"oth\">100<\/td><td class=\"oth\">43<\/td><td class=\"oth\">8<\/td><td class=\"oth\">100<\/td><td class=\"oth\">55<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetophenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-86-2\/Acetophenone\" target=\"_blank\" rel=\"noopener\">Acetophenone<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><td class=\"oth\">105<\/td><td class=\"oth\">51<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\">3- and 4-Methylphenol<\/td><td class=\"oth\">7.33<\/td><td class=\"oth\">10<\/td><td class=\"oth\">70<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosomorpholine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-89-2\/N-Nitrosomorpholine\" target=\"_blank\" rel=\"noopener\">N-Nitrosomorpholine<\/a><\/td><td class=\"oth\">7.331<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">86<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-53-4\/o-Toluidine\" target=\"_blank\" rel=\"noopener\">o-Toluidine<\/a><\/td><td class=\"oth\">7.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">106<\/td><td class=\"oth\">79<\/td><td class=\"oth\">8<\/td><td class=\"oth\">107<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloroethane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67-72-1\/Hexachloroethane\" target=\"_blank\" rel=\"noopener\">Hexachloroethane<\/a><\/td><td class=\"oth\">7.49<\/td><td class=\"oth\">10<\/td><td class=\"oth\">201<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">201<\/td><td class=\"oth\">131<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene-d5\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4165-60-0\/Nitrobenzene-d5\" target=\"_blank\" rel=\"noopener\">Nitrobenzene-d5<\/a><\/td><td class=\"oth\">7.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">82<\/td><td class=\"oth\">12<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-95-3\/Nitrobenzene\" target=\"_blank\" rel=\"noopener\">Nitrobenzene<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123<\/td><td class=\"oth\">51<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosopiperidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-75-4\/N-Nitrosopiperidine\" target=\"_blank\" rel=\"noopener\">N-Nitrosopiperidine<\/a><\/td><td class=\"oth\">7.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">114<\/td><td class=\"oth\">84<\/td><td class=\"oth\">6<\/td><td class=\"oth\">114<\/td><td class=\"oth\">97<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isophorone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/78-59-1\/Isophorone\" target=\"_blank\" rel=\"noopener\">Isophorone<\/a><\/td><td class=\"oth\">8.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">82<\/td><td class=\"oth\">8<\/td><td class=\"oth\">82<\/td><td class=\"oth\">54<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-75-5\/2-Nitrophenol\" target=\"_blank\" rel=\"noopener\">2-Nitrophenol<\/a><\/td><td class=\"oth\">8.19<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzoic acid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/65-85-0\/Benzoic acid\" target=\"_blank\" rel=\"noopener\">Benzoic acid<\/a><\/td><td class=\"oth\">8.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><td class=\"oth\">105<\/td><td class=\"oth\">77<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dimethylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-67-9\/2,4-Dimethylphenol\" target=\"_blank\" rel=\"noopener\">2,4-Dimethylphenol<\/a><\/td><td class=\"oth\">8.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">122<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for O,O,O-Triethyl phosphorothioate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126-68-1\/O,O,O-Triethyl phosphorothioate\" target=\"_blank\" rel=\"noopener\">O,O,O-Triethyl phosphorothioate<\/a><\/td><td class=\"oth\">8.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">114<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-chloroethoxy)methane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/111-91-1\/Bis(2-chloroethoxy)methane\" target=\"_blank\" rel=\"noopener\">Bis(2-chloroethoxy)methane<\/a><\/td><td class=\"oth\">8.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">63<\/td><td class=\"oth\">27<\/td><td class=\"oth\">12<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-83-2\/2,4-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dichlorophenol<\/a><\/td><td class=\"oth\">8.64<\/td><td class=\"oth\">10<\/td><td class=\"oth\">98<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">98<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phentermine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-09-8\/Phentermine\" target=\"_blank\" rel=\"noopener\">Phentermine<\/a><\/td><td class=\"oth\">8.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">58<\/td><td class=\"oth\">42<\/td><td class=\"oth\">22<\/td><td class=\"oth\">134<\/td><td class=\"oth\">91<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4-Trichlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-82-1\/1,2,4-Trichlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4-Trichlorobenzene<\/a><\/td><td class=\"oth\">8.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">180<\/td><td class=\"oth\">145<\/td><td class=\"oth\">12<\/td><td class=\"oth\">180<\/td><td class=\"oth\">109<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene-d8\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1146-65-2\/Naphthalene-d8\" target=\"_blank\" rel=\"noopener\">Naphthalene-d8<\/a><\/td><td class=\"oth\">8.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">134<\/td><td class=\"oth\">14<\/td><td class=\"oth\">136<\/td><td class=\"oth\">84<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Naphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-20-3\/Naphthalene\" target=\"_blank\" rel=\"noopener\">Naphthalene<\/a><\/td><td class=\"oth\">8.92<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">103<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-Terpineol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/98-55-5\/\u03b1-Terpineol\" target=\"_blank\" rel=\"noopener\">\u03b1-Terpineol<\/a><\/td><td class=\"oth\">9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">136<\/td><td class=\"oth\">121<\/td><td class=\"oth\">8<\/td><td class=\"oth\">136<\/td><td class=\"oth\">93<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-47-8\/4-Chloroaniline\" target=\"_blank\" rel=\"noopener\">4-Chloroaniline<\/a><\/td><td class=\"oth\">9.06<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">100<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,6-Dichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-65-0\/2,6-Dichlorophenol\" target=\"_blank\" rel=\"noopener\">2,6-Dichlorophenol<\/a><\/td><td class=\"oth\">9.07<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">164<\/td><td class=\"oth\">63<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachloropropene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1888-71-7\/Hexachloropropene\" target=\"_blank\" rel=\"noopener\">Hexachloropropene<\/a><\/td><td class=\"oth\">9.12<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><td class=\"oth\">215<\/td><td class=\"oth\">119<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobutadiene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-68-3\/Hexachlorobutadiene\" target=\"_blank\" rel=\"noopener\">Hexachlorobutadiene<\/a><\/td><td class=\"oth\">9.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">190<\/td><td class=\"oth\">14<\/td><td class=\"oth\">260<\/td><td class=\"oth\">190<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quinoline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-22-5\/Quinoline\" target=\"_blank\" rel=\"noopener\">Quinoline<\/a><\/td><td class=\"oth\">9.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">102<\/td><td class=\"oth\">16<\/td><td class=\"oth\">129<\/td><td class=\"oth\">76<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Caprolactam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/105-60-2\/Caprolactam\" target=\"_blank\" rel=\"noopener\">Caprolactam<\/a><\/td><td class=\"oth\">9.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">113<\/td><td class=\"oth\">85<\/td><td class=\"oth\">6<\/td><td class=\"oth\">113<\/td><td class=\"oth\">56<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Phenylenediamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/106-50-3\/1,4-Phenylenediamine\" target=\"_blank\" rel=\"noopener\">1,4-Phenylenediamine<\/a><\/td><td class=\"oth\">9.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">108<\/td><td class=\"oth\">80<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for N-Nitrosodibutylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/924-16-3\/N-Nitrosodibutylamine\" target=\"_blank\" rel=\"noopener\">N-Nitrosodibutylamine<\/a><\/td><td class=\"oth\">9.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">116<\/td><td class=\"oth\">99<\/td><td class=\"oth\">6<\/td><td class=\"oth\">116<\/td><td class=\"oth\">74<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chloro-3-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-50-7\/4-Chloro-3-methylphenol\" target=\"_blank\" rel=\"noopener\">4-Chloro-3-methylphenol<\/a><\/td><td class=\"oth\">10.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">142<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><td class=\"oth\">142<\/td><td class=\"oth\">77<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\">Isosafrole I<\/td><td class=\"oth\">10.14<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-57-6\/2-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">2-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Methylnaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-12-0\/1-Methylnaphthalene\" target=\"_blank\" rel=\"noopener\">1-Methylnaphthalene<\/a><\/td><td class=\"oth\">10.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">16<\/td><td class=\"oth\">141<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2,4,5-Tetrachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-94-3\/1,2,4,5-Tetrachlorobenzene\" target=\"_blank\" rel=\"noopener\">1,2,4,5-Tetrachlorobenzene<\/a><\/td><td class=\"oth\">10.61<\/td><td class=\"oth\">10<\/td><td class=\"oth\">216<\/td><td class=\"oth\">181<\/td><td class=\"oth\">14<\/td><td class=\"oth\">216<\/td><td class=\"oth\">108<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\">Hexachloropentadiene<\/td><td class=\"oth\">10.62<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3-Dichloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-27-5\/2,3-Dichloroaniline\" target=\"_blank\" rel=\"noopener\">2,3-Dichloroaniline<\/a><\/td><td class=\"oth\">10.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">161<\/td><td class=\"oth\">90<\/td><td class=\"oth\">16<\/td><td class=\"oth\">163<\/td><td class=\"oth\">90<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-06-2\/2,4,6-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Trichlorophenol<\/a><\/td><td class=\"oth\">10.85<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,5-Trichlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-95-4\/2,4,5-Trichlorophenol\" target=\"_blank\" rel=\"noopener\">2,4,5-Trichlorophenol<\/a><\/td><td class=\"oth\">10.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">132<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><td class=\"oth\">196<\/td><td class=\"oth\">97<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Fluorobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/321-60-8\/2-Fluorobiphenyl\" target=\"_blank\" rel=\"noopener\">2-Fluorobiphenyl<\/a><\/td><td class=\"oth\">11.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">172<\/td><td class=\"oth\">171<\/td><td class=\"oth\">12<\/td><td class=\"oth\">172<\/td><td class=\"oth\">170<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-58-7\/2-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">2-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.15<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">162<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\">Isosafrole II<\/td><td class=\"oth\">11.17<\/td><td class=\"oth\">10<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">104<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Safrole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-59-7\/Safrole\" target=\"_blank\" rel=\"noopener\">Safrole<\/a><\/td><td class=\"oth\">11.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">131<\/td><td class=\"oth\">103<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">11.21<\/td><td class=\"oth\">10<\/td><td class=\"oth\">154<\/td><td class=\"oth\">152<\/td><td class=\"oth\">22<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Chloronaphthalene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-13-1\/1-Chloronaphthalene\" target=\"_blank\" rel=\"noopener\">1-Chloronaphthalene<\/a><\/td><td class=\"oth\">11.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">127<\/td><td class=\"oth\">16<\/td><td class=\"oth\">127<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-74-4\/o-Nitroaniline\" target=\"_blank\" rel=\"noopener\">o-Nitroaniline<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">92<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-84-8\/Diphenyl ether\" target=\"_blank\" rel=\"noopener\">Diphenyl ether<\/a><\/td><td class=\"oth\">11.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">170<\/td><td class=\"oth\">142<\/td><td class=\"oth\">10<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Naphthoquinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/130-15-4\/1,4-Naphthoquinone\" target=\"_blank\" rel=\"noopener\">1,4-Naphthoquinone<\/a><\/td><td class=\"oth\">11.57<\/td><td class=\"oth\">10<\/td><td class=\"oth\">158<\/td><td class=\"oth\">130<\/td><td class=\"oth\">8<\/td><td class=\"oth\">158<\/td><td class=\"oth\">102<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,2-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/528-29-0\/1,2-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,2-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.86<\/td><td class=\"oth\">10<\/td><td class=\"oth\">122<\/td><td class=\"oth\">75<\/td><td class=\"oth\">12<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-65-0\/1,3-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3-Dinitrobenzene<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">75<\/td><td class=\"oth\">20<\/td><td class=\"oth\">76<\/td><td class=\"oth\">50<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-62-8\/Diphenyl phthalate\" target=\"_blank\" rel=\"noopener\">Diphenyl phthalate<\/a><\/td><td class=\"oth\">11.87<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">133<\/td><td class=\"oth\">8<\/td><td class=\"oth\">163<\/td><td class=\"oth\">77<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\">1,6-Dinitrotoluene<\/td><td class=\"oth\">11.95<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">148<\/td><td class=\"oth\">8<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,4-Dinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-25-4\/1,4-Dinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,4-Dinitrobenzene<\/a><\/td><td class=\"oth\">12.01<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">51<\/td><td class=\"oth\">14<\/td><td class=\"oth\">76<\/td><td class=\"oth\">63<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/208-96-8\/Acenaphthylene\" target=\"_blank\" rel=\"noopener\">Acenaphthylene<\/a><\/td><td class=\"oth\">12.02<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">126<\/td><td class=\"oth\">24<\/td><td class=\"oth\">152<\/td><td class=\"oth\">76<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-09-2\/3-Nitroaniline\" target=\"_blank\" rel=\"noopener\">3-Nitroaniline<\/a><\/td><td class=\"oth\">12.25<\/td><td class=\"oth\">10<\/td><td class=\"oth\">92<\/td><td class=\"oth\">65<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15067-26-2\/Acenaphthene-d10\" target=\"_blank\" rel=\"noopener\">Acenaphthene-d10<\/a><\/td><td class=\"oth\">12.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">164<\/td><td class=\"oth\">162<\/td><td class=\"oth\">14<\/td><td class=\"oth\">164<\/td><td class=\"oth\">160<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acenaphthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/83-32-9\/Acenaphthene\" target=\"_blank\" rel=\"noopener\">Acenaphthene<\/a><\/td><td class=\"oth\">12.37<\/td><td class=\"oth\">10<\/td><td class=\"oth\">153<\/td><td class=\"oth\">126<\/td><td class=\"oth\">36<\/td><td class=\"oth\">153<\/td><td class=\"oth\">77<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-28-5\/2,4-Dinitrophenol\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrophenol<\/a><\/td><td class=\"oth\">12.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">6<\/td><td class=\"oth\">184<\/td><td class=\"oth\">107<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitrophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-02-7\/4-Nitrophenol\" target=\"_blank\" rel=\"noopener\">4-Nitrophenol<\/a><\/td><td class=\"oth\">12.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">109<\/td><td class=\"oth\">6<\/td><td class=\"oth\">139<\/td><td class=\"oth\">81<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-93-5\/Pentachlorobenzene\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzene<\/a><\/td><td class=\"oth\">12.66<\/td><td class=\"oth\">10<\/td><td class=\"oth\">250<\/td><td class=\"oth\">215<\/td><td class=\"oth\">16<\/td><td class=\"oth\">250<\/td><td class=\"oth\">142<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenzofuran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-64-9\/Dibenzofuran\" target=\"_blank\" rel=\"noopener\">Dibenzofuran<\/a><\/td><td class=\"oth\">12.73<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">139<\/td><td class=\"oth\">22<\/td><td class=\"oth\">139<\/td><td class=\"oth\">63<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4-Dinitrotoluene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-14-2\/2,4-Dinitrotoluene\" target=\"_blank\" rel=\"noopener\">2,4-Dinitrotoluene<\/a><\/td><td class=\"oth\">12.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">119<\/td><td class=\"oth\">6<\/td><td class=\"oth\">165<\/td><td class=\"oth\">63<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/134-32-7\/1-Naphthylamine\" target=\"_blank\" rel=\"noopener\">1-Naphthylamine<\/a><\/td><td class=\"oth\">12.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/935-95-5\/2,3,5,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">12.91<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">133<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,4,6-Tetrachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-90-2\/2,3,4,6-Tetrachlorophenol\" target=\"_blank\" rel=\"noopener\">2,3,4,6-Tetrachlorophenol<\/a><\/td><td class=\"oth\">13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">232<\/td><td class=\"oth\">168<\/td><td class=\"oth\">12<\/td><td class=\"oth\">234<\/td><td class=\"oth\">131<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Naphthylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-59-8\/2-Naphthylamine\" target=\"_blank\" rel=\"noopener\">2-Naphthylamine<\/a><\/td><td class=\"oth\">13.03<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">116<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">115<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diethyl Phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-66-2\/Diethyl Phthalate\" target=\"_blank\" rel=\"noopener\">Diethyl Phthalate<\/a><\/td><td class=\"oth\">13.3<\/td><td class=\"oth\">10<\/td><td class=\"oth\">177<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/544-76-3\/Hexadecane\" target=\"_blank\" rel=\"noopener\">Hexadecane<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-73-7\/Fluorene\" target=\"_blank\" rel=\"noopener\">Fluorene<\/a><\/td><td class=\"oth\">13.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165<\/td><td class=\"oth\">139<\/td><td class=\"oth\">26<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zinophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/297-97-2\/Zinophos\" target=\"_blank\" rel=\"noopener\">Zinophos<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">143<\/td><td class=\"oth\">79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">107<\/td><td class=\"oth\">52<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 5-Nitro-o-toluidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-55-8\/5-Nitro-o-toluidine\" target=\"_blank\" rel=\"noopener\">5-Nitro-o-toluidine<\/a><\/td><td class=\"oth\">13.45<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">106<\/td><td class=\"oth\">10<\/td><td class=\"oth\">152<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/100-01-6\/4-Nitroaniline\" target=\"_blank\" rel=\"noopener\">4-Nitroaniline<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">108<\/td><td class=\"oth\">8<\/td><td class=\"oth\">138<\/td><td class=\"oth\">80<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Chlorophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7005-72-3\/4-Chlorophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Chlorophenyl phenyl ether<\/a><\/td><td class=\"oth\">13.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">204<\/td><td class=\"oth\">77<\/td><td class=\"oth\">22<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,6-Dinitro-2-methylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/534-52-1\/4,6-Dinitro-2-methylphenol\" target=\"_blank\" rel=\"noopener\">4,6-Dinitro-2-methylphenol<\/a><\/td><td class=\"oth\">13.54<\/td><td class=\"oth\">10<\/td><td class=\"oth\">198<\/td><td class=\"oth\">168<\/td><td class=\"oth\">6<\/td><td class=\"oth\">198<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-39-4\/Diphenylamine\" target=\"_blank\" rel=\"noopener\">Diphenylamine<\/a><\/td><td class=\"oth\">13.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">169<\/td><td class=\"oth\">66<\/td><td class=\"oth\">22<\/td><td class=\"oth\">169<\/td><td class=\"oth\">77<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-33-3\/Azobenzene\" target=\"_blank\" rel=\"noopener\">Azobenzene<\/a><\/td><td class=\"oth\">13.76<\/td><td class=\"oth\">10<\/td><td class=\"oth\">182<\/td><td class=\"oth\">105<\/td><td class=\"oth\">6<\/td><td class=\"oth\">182<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4,6-Tribromophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-79-6\/2,4,6-Tribromophenol\" target=\"_blank\" rel=\"noopener\">2,4,6-Tribromophenol<\/a><\/td><td class=\"oth\">13.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">330<\/td><td class=\"oth\">222<\/td><td class=\"oth\">20<\/td><td class=\"oth\">332<\/td><td class=\"oth\">143<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulfotepp\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3689-24-5\/Sulfotepp\" target=\"_blank\" rel=\"noopener\">Sulfotepp<\/a><\/td><td class=\"oth\">14.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">146<\/td><td class=\"oth\">10<\/td><td class=\"oth\">322<\/td><td class=\"oth\">146<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 1,3,5-Trinitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-35-4\/1,3,5-Trinitrobenzene\" target=\"_blank\" rel=\"noopener\">1,3,5-Trinitrobenzene<\/a><\/td><td class=\"oth\">14.23<\/td><td class=\"oth\">10<\/td><td class=\"oth\">213<\/td><td class=\"oth\">167<\/td><td class=\"oth\">8<\/td><td class=\"oth\">213<\/td><td class=\"oth\">74<\/td><td class=\"oth\">38<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\">Diallate 1<\/td><td class=\"oth\">14.31<\/td><td class=\"oth\">10<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phorate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-02-2\/Phorate\" target=\"_blank\" rel=\"noopener\">Phorate<\/a><\/td><td class=\"oth\">14.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">75<\/td><td class=\"oth\">47<\/td><td class=\"oth\">8<\/td><td class=\"oth\">121<\/td><td class=\"oth\">47<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenacetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-44-2\/Phenacetin\" target=\"_blank\" rel=\"noopener\">Phenacetin<\/a><\/td><td class=\"oth\">14.35<\/td><td class=\"oth\">10<\/td><td class=\"oth\">179<\/td><td class=\"oth\">137<\/td><td class=\"oth\">8<\/td><td class=\"oth\">179<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Bromophenyl phenyl ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-55-3\/4-Bromophenyl phenyl ether\" target=\"_blank\" rel=\"noopener\">4-Bromophenyl phenyl ether<\/a><\/td><td class=\"oth\">14.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">248<\/td><td class=\"oth\">141<\/td><td class=\"oth\">14<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\">Diallate 2<\/td><td class=\"oth\">14.48<\/td><td class=\"oth\">10<\/td><td class=\"oth\">234<\/td><td class=\"oth\">150<\/td><td class=\"oth\">16<\/td><td class=\"oth\">86<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">14.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">284<\/td><td class=\"oth\">249<\/td><td class=\"oth\">14<\/td><td class=\"oth\">288<\/td><td class=\"oth\">216<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">14.6<\/td><td class=\"oth\">10<\/td><td class=\"oth\">93<\/td><td class=\"oth\">63<\/td><td class=\"oth\">8<\/td><td class=\"oth\">125<\/td><td class=\"oth\">47<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1912-24-9\/Atrazine\" target=\"_blank\" rel=\"noopener\">Atrazine<\/a><\/td><td class=\"oth\">14.82<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">122<\/td><td class=\"oth\">8<\/td><td class=\"oth\">215<\/td><td class=\"oth\">200<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorophenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/87-86-5\/Pentachlorophenol\" target=\"_blank\" rel=\"noopener\">Pentachlorophenol<\/a><\/td><td class=\"oth\">14.9<\/td><td class=\"oth\">10<\/td><td class=\"oth\">266<\/td><td class=\"oth\">167<\/td><td class=\"oth\">22<\/td><td class=\"oth\">270<\/td><td class=\"oth\">169<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Aminobiphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-67-1\/4-Aminobiphenyl\" target=\"_blank\" rel=\"noopener\">4-Aminobiphenyl<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">168<\/td><td class=\"oth\">141<\/td><td class=\"oth\">8<\/td><td class=\"oth\">168<\/td><td class=\"oth\">167<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloronitrobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Pentachloronitrobenzene\" target=\"_blank\" rel=\"noopener\">Pentachloronitrobenzene<\/a><\/td><td class=\"oth\">14.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">295<\/td><td class=\"oth\">265<\/td><td class=\"oth\">8<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propyzamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23950-58-5\/Propyzamide\" target=\"_blank\" rel=\"noopener\">Propyzamide<\/a><\/td><td class=\"oth\">15.13<\/td><td class=\"oth\">10<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">14<\/td><td class=\"oth\">254<\/td><td class=\"oth\">191<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene-d10\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1517-22-2\/Phenanthrene-d10\" target=\"_blank\" rel=\"noopener\">Phenanthrene-d10<\/a><\/td><td class=\"oth\">15.24<\/td><td class=\"oth\">10<\/td><td class=\"oth\">188<\/td><td class=\"oth\">160<\/td><td class=\"oth\">20<\/td><td class=\"oth\">184<\/td><td class=\"oth\">154<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Octadecane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/593-45-3\/Octadecane\" target=\"_blank\" rel=\"noopener\">Octadecane<\/a><\/td><td class=\"oth\">15.27<\/td><td class=\"oth\">10<\/td><td class=\"oth\">85<\/td><td class=\"oth\">43<\/td><td class=\"oth\">6<\/td><td class=\"oth\">99<\/td><td class=\"oth\">41<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-01-8\/Phenanthrene\" target=\"_blank\" rel=\"noopener\">Phenanthrene<\/a><\/td><td class=\"oth\">15.29<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dinoseb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88-85-7\/Dinoseb\" target=\"_blank\" rel=\"noopener\">Dinoseb<\/a><\/td><td class=\"oth\">15.34<\/td><td class=\"oth\">10<\/td><td class=\"oth\">163<\/td><td class=\"oth\">116<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">117<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Disulfoton\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-04-4\/Disulfoton\" target=\"_blank\" rel=\"noopener\">Disulfoton<\/a><\/td><td class=\"oth\">15.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">88<\/td><td class=\"oth\">60<\/td><td class=\"oth\">6<\/td><td class=\"oth\">97<\/td><td class=\"oth\">65<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene<\/a><\/td><td class=\"oth\">15.39<\/td><td class=\"oth\">10<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">18<\/td><td class=\"oth\">178<\/td><td class=\"oth\">151<\/td><td class=\"oth\">32<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-74-8\/Carbazole\" target=\"_blank\" rel=\"noopener\">Carbazole<\/a><\/td><td class=\"oth\">15.741<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">166<\/td><td class=\"oth\">12<\/td><td class=\"oth\">167<\/td><td class=\"oth\">139<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl Parathion\" target=\"_blank\" rel=\"noopener\">Methyl Parathion<\/a><\/td><td class=\"oth\">16.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">109<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">79<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for di-n-Butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-74-2\/di-n-Butyl phthalate\" target=\"_blank\" rel=\"noopener\">di-n-Butyl phthalate<\/a><\/td><td class=\"oth\">16.58<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">65<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4-Nitroquinoline-N-oxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-57-5\/4-Nitroquinoline-N-oxide\" target=\"_blank\" rel=\"noopener\">4-Nitroquinoline-N-oxide<\/a><\/td><td class=\"oth\">16.83<\/td><td class=\"oth\">10<\/td><td class=\"oth\">190<\/td><td class=\"oth\">160<\/td><td class=\"oth\">8<\/td><td class=\"oth\">101<\/td><td class=\"oth\">75<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethyl Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-38-2\/Ethyl Parathion\" target=\"_blank\" rel=\"noopener\">Ethyl Parathion<\/a><\/td><td class=\"oth\">16.89<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">291<\/td><td class=\"oth\">81<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methapyrilene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-80-5\/Methapyrilene\" target=\"_blank\" rel=\"noopener\">Methapyrilene<\/a><\/td><td class=\"oth\">17.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">97<\/td><td class=\"oth\">53<\/td><td class=\"oth\">16<\/td><td class=\"oth\">190<\/td><td class=\"oth\">97<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isodrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-73-6\/Isodrin\" target=\"_blank\" rel=\"noopener\">Isodrin<\/a><\/td><td class=\"oth\">17.36<\/td><td class=\"oth\">10<\/td><td class=\"oth\">261<\/td><td class=\"oth\">226<\/td><td class=\"oth\">16<\/td><td class=\"oth\">261<\/td><td class=\"oth\">191<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">176<\/td><td class=\"oth\">26<\/td><td class=\"oth\">184<\/td><td class=\"oth\">156<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/206-44-0\/Fluoranthene\" target=\"_blank\" rel=\"noopener\">Fluoranthene<\/a><\/td><td class=\"oth\">17.65<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">152<\/td><td class=\"oth\">30<\/td><td class=\"oth\">200<\/td><td class=\"oth\">174<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-87-5\/Benzidine\" target=\"_blank\" rel=\"noopener\">Benzidine<\/a><\/td><td class=\"oth\">17.99<\/td><td class=\"oth\">10<\/td><td class=\"oth\">184<\/td><td class=\"oth\">166<\/td><td class=\"oth\">16<\/td><td class=\"oth\">200<\/td><td class=\"oth\">149<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/129-00-0\/Pyrene\" target=\"_blank\" rel=\"noopener\">Pyrene<\/a><\/td><td class=\"oth\">18.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">200<\/td><td class=\"oth\">150<\/td><td class=\"oth\">26<\/td><td class=\"oth\">212<\/td><td class=\"oth\">208<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Terphenyl-d14\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1718-51-0\/p-Terphenyl-d14\" target=\"_blank\" rel=\"noopener\">p-Terphenyl-d14<\/a><\/td><td class=\"oth\">18.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">244<\/td><td class=\"oth\">242<\/td><td class=\"oth\">14<\/td><td class=\"oth\">244<\/td><td class=\"oth\">240<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 1\" target=\"_blank\" rel=\"noopener\">Aramite 1<\/a><\/td><td class=\"oth\">18.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><td class=\"oth\">175<\/td><td class=\"oth\">107<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aramite 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/140-57-8\/Aramite 2\" target=\"_blank\" rel=\"noopener\">Aramite 2<\/a><\/td><td class=\"oth\">18.7<\/td><td class=\"oth\">10<\/td><td class=\"oth\">185<\/td><td class=\"oth\">63<\/td><td class=\"oth\">12<\/td><td class=\"oth\">319<\/td><td class=\"oth\">185<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for p-Dimethylaminoazobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-11-7\/p-Dimethylaminoazobenzene\" target=\"_blank\" rel=\"noopener\">p-Dimethylaminoazobenzene<\/a><\/td><td class=\"oth\">18.79<\/td><td class=\"oth\">10<\/td><td class=\"oth\">225<\/td><td class=\"oth\">148<\/td><td class=\"oth\">6<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzilate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/510-15-6\/Chlorobenzilate\" target=\"_blank\" rel=\"noopener\">Chlorobenzilate<\/a><\/td><td class=\"oth\">18.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">251<\/td><td class=\"oth\">139<\/td><td class=\"oth\">12<\/td><td class=\"oth\">251<\/td><td class=\"oth\">111<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Famphur\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52-85-7\/Famphur\" target=\"_blank\" rel=\"noopener\">Famphur<\/a><\/td><td class=\"oth\">19.4<\/td><td class=\"oth\">10<\/td><td class=\"oth\">218<\/td><td class=\"oth\">109<\/td><td class=\"oth\">14<\/td><td class=\"oth\">125<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dimethylbenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-93-7\/3,3&amp;apos;-Dimethylbenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dimethylbenzidine<\/a><\/td><td class=\"oth\">19.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">211<\/td><td class=\"oth\">196<\/td><td class=\"oth\">8<\/td><td class=\"oth\">211<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Kepone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/143-50-0\/Kepone\" target=\"_blank\" rel=\"noopener\">Kepone<\/a><\/td><td class=\"oth\">19.47<\/td><td class=\"oth\">10<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><td class=\"oth\">237<\/td><td class=\"oth\">143<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzyl butyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85-68-7\/Benzyl butyl phthalate\" target=\"_blank\" rel=\"noopener\">Benzyl butyl phthalate<\/a><\/td><td class=\"oth\">19.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">206<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) adipate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-23-1\/Bis(2-ethylhexyl) adipate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) adipate<\/a><\/td><td class=\"oth\">19.81<\/td><td class=\"oth\">10<\/td><td class=\"oth\">129<\/td><td class=\"oth\">55<\/td><td class=\"oth\">14<\/td><td class=\"oth\">129<\/td><td class=\"oth\">83<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Acetylaminofluorene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-96-3\/2-Acetylaminofluorene\" target=\"_blank\" rel=\"noopener\">2-Acetylaminofluorene<\/a><\/td><td class=\"oth\">19.93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">223<\/td><td class=\"oth\">181<\/td><td class=\"oth\">10<\/td><td class=\"oth\">181<\/td><td class=\"oth\">152<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-55-3\/Benz[a]anthracene\" target=\"_blank\" rel=\"noopener\">Benz[a]anthracene<\/a><\/td><td class=\"oth\">20.5<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">226<\/td><td class=\"oth\">200<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1719-03-5\/Chrysene-d12\" target=\"_blank\" rel=\"noopener\">Chrysene-d12<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">240<\/td><td class=\"oth\">238<\/td><td class=\"oth\">14<\/td><td class=\"oth\">240<\/td><td class=\"oth\">236<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,3&amp;apos;-Dichlorobenzidine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91-94-1\/3,3&amp;apos;-Dichlorobenzidine\" target=\"_blank\" rel=\"noopener\">3,3&#8242;-Dichlorobenzidine<\/a><\/td><td class=\"oth\">20.51<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">181<\/td><td class=\"oth\">22<\/td><td class=\"oth\">252<\/td><td class=\"oth\">182<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Methylenebis(2-chloroaniline)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-14-4\/4,4&amp;apos;-Methylenebis(2-chloroaniline)\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Methylenebis(2-chloroaniline)<\/a><\/td><td class=\"oth\">20.53<\/td><td class=\"oth\">10<\/td><td class=\"oth\">231<\/td><td class=\"oth\">195<\/td><td class=\"oth\">16<\/td><td class=\"oth\">266<\/td><td class=\"oth\">231<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/218-01-9\/Chrysene\" target=\"_blank\" rel=\"noopener\">Chrysene<\/a><\/td><td class=\"oth\">20.56<\/td><td class=\"oth\">10<\/td><td class=\"oth\">228<\/td><td class=\"oth\">202<\/td><td class=\"oth\">22<\/td><td class=\"oth\">228<\/td><td class=\"oth\">201<\/td><td class=\"oth\">36<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bis(2-ethylhexyl) phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-81-7\/Bis(2-ethylhexyl) phthalate\" target=\"_blank\" rel=\"noopener\">Bis(2-ethylhexyl) phthalate<\/a><\/td><td class=\"oth\">20.78<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167<\/td><td class=\"oth\">149<\/td><td class=\"oth\">8<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Methylchrysene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1705-85-7\/6-Methylchrysene\" target=\"_blank\" rel=\"noopener\">6-Methylchrysene<\/a><\/td><td class=\"oth\">21.46<\/td><td class=\"oth\">10<\/td><td class=\"oth\">242<\/td><td class=\"oth\">226<\/td><td class=\"oth\">28<\/td><td class=\"oth\">239<\/td><td class=\"oth\">213<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Di-n-octyl phthalate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-84-0\/Di-n-octyl phthalate\" target=\"_blank\" rel=\"noopener\">Di-n-octyl phthalate<\/a><\/td><td class=\"oth\">22.08<\/td><td class=\"oth\">10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">121<\/td><td class=\"oth\">12<\/td><td class=\"oth\">149<\/td><td class=\"oth\">93<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[b]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/205-99-2\/Benzo[b]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[b]fluoranthene<\/a><\/td><td class=\"oth\">22.68<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 7,12-Dimethylbenz[a]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-97-6\/7,12-Dimethylbenz[a]anthracene\" target=\"_blank\" rel=\"noopener\">7,12-Dimethylbenz[a]anthracene<\/a><\/td><td class=\"oth\">22.69<\/td><td class=\"oth\">10<\/td><td class=\"oth\">256<\/td><td class=\"oth\">241<\/td><td class=\"oth\">12<\/td><td class=\"oth\">241<\/td><td class=\"oth\">226<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[k]fluoranthene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/207-08-9\/Benzo[k]fluoranthene\" target=\"_blank\" rel=\"noopener\">Benzo[k]fluoranthene<\/a><\/td><td class=\"oth\">22.74<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[a]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-32-8\/Benzo[a]pyrene\" target=\"_blank\" rel=\"noopener\">Benzo[a]pyrene<\/a><\/td><td class=\"oth\">23.41<\/td><td class=\"oth\">10<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><td class=\"oth\">250<\/td><td class=\"oth\">224<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Perylene-d12\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1520-96-3\/Perylene-d12\" target=\"_blank\" rel=\"noopener\">Perylene-d12<\/a><\/td><td class=\"oth\">23.55<\/td><td class=\"oth\">10<\/td><td class=\"oth\">264<\/td><td class=\"oth\">262<\/td><td class=\"oth\">20<\/td><td class=\"oth\">264<\/td><td class=\"oth\">260<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3-Methylcholanthrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-49-5\/3-Methylcholanthrene\" target=\"_blank\" rel=\"noopener\">3-Methylcholanthrene<\/a><\/td><td class=\"oth\">24.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">268<\/td><td class=\"oth\">253<\/td><td class=\"oth\">14<\/td><td class=\"oth\">252<\/td><td class=\"oth\">226<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz(a,h)acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/226-36-8\/Dibenz(a,h)acridine\" target=\"_blank\" rel=\"noopener\">Dibenz(a,h)acridine<\/a><\/td><td class=\"oth\">25.8<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">252<\/td><td class=\"oth\">34<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,j]acridine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/224-42-0\/Dibenz[a,j]acridine\" target=\"_blank\" rel=\"noopener\">Dibenz[a,j]acridine<\/a><\/td><td class=\"oth\">25.88<\/td><td class=\"oth\">10<\/td><td class=\"oth\">279<\/td><td class=\"oth\">277<\/td><td class=\"oth\">30<\/td><td class=\"oth\">278<\/td><td class=\"oth\">250<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Indeno[1,2,3-cd]pyrene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/193-39-5\/Indeno[1,2,3-cd]pyrene\" target=\"_blank\" rel=\"noopener\">Indeno[1,2,3-cd]pyrene<\/a><\/td><td class=\"oth\">26.32<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">276<\/td><td class=\"oth\">250<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dibenz[a,h]anthracene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-70-3\/Dibenz[a,h]anthracene\" target=\"_blank\" rel=\"noopener\">Dibenz[a,h]anthracene<\/a><\/td><td class=\"oth\">26.43<\/td><td class=\"oth\">10<\/td><td class=\"oth\">139<\/td><td class=\"oth\">126<\/td><td class=\"oth\">8<\/td><td class=\"oth\">139<\/td><td class=\"oth\">113<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzo[ghi]perylene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/191-24-2\/Benzo[ghi]perylene\" target=\"_blank\" rel=\"noopener\">Benzo[ghi]perylene<\/a><\/td><td class=\"oth\">27.05<\/td><td class=\"oth\">10<\/td><td class=\"oth\">138<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><td class=\"oth\">138<\/td><td class=\"oth\">124<\/td><td class=\"oth\">28<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Standards were combined and diluted to a concentration of 100 ppb.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270e<\/li><li>RMX-library<\/li><li>environmental<\/li><li>semivolatile<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 2:<\/strong> Auch im Spurenbereich unterst\u00fctzen RMX-5Sil-MS-S\u00e4ulen eine hohe Datenqualit\u00e4t f\u00fcr chemisch anspruchsvolle halbfl\u00fcchtige Verbindungen.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.png\" alt=\"Select Semivolatiles at Low Levels on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1526<\/p><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>SVOC MegaMix 150 kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31907\" rel=\"noopener\">cat.# 31907<\/a>)<\/td><\/tr><tr><td><\/td><td>Revised SV internal standard mix (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31886\" rel=\"noopener\">cat.# 31886<\/a>)<\/td><\/tr><tr><td><\/td><td>Base neutral surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31024\" rel=\"noopener\">cat.# 31024<\/a>)<\/td><\/tr><tr><td><\/td><td>Acid surrogate mix (4\/89 SOW) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31025\" rel=\"noopener\">cat.# 31025<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Dichloromethane<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1, 10, 100 ppb <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID Precision liner w\/wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23267\" rel=\"noopener\">cat.# 23267<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>12 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>40 &#176;C (hold 1 min) to 280 &#176;C at 12 &#176;C\/min to 310 &#176;C at 3 &#176;C\/min (hold 1 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>1.2 mL\/min @ 40 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>SRM\/MRM<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>330 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Triple Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Collision Gas:<\/th><td>Ar <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Emission Current:<\/th><td>70 \u03bcA<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Literaturhinweise<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Brosch\u00fcre zu RMX GC S\u00e4ulen, GNBR4923-UNV, Restek Corporation, 2026. <a href=\"https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance\">https:\/\/discover.restek.com\/articles\/gnbr4923\/rmx-gc-columns-unleash-your-performance<\/a><\/li>\n\n\n\n<li>E. Pack, J. Hoisington, C. English, R. Dhandapani, and C. Myers, Comprehensive trace-level semivolatiles analysis by GC-MS\/MS (EPA Method 8270E), Application note, EVAN4919-US, Restek Corporation, 2025. <a href=\"https:\/\/discover.restek.com\/application-notes-zh\/evan4919\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-epa-method-8270e\">https:\/\/discover.restek.com\/application-notes\/evan4919\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-epa-method-8270e<\/a><\/li>\n<\/ol>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/articles-zh\/gnot3445\/ezgc-online-tools\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE.png\" alt=\"\" class=\"wp-image-84606\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/de\/rmx\/\"><img loading=\"lazy\" decoding=\"async\" width=\"2040\" height=\"1976\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE.png\" alt=\"\" class=\"wp-image-84612\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE.png 2040w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-300x291.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-1024x992.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-768x744.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-1536x1488.png 1536w\" sizes=\"auto, (max-width: 2040px) 100vw, 2040px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Vorgestellte Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/17323\">                                Art.-Nr. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC Kapillars\u00e4ule, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/17323\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23267\">                                Art.-Nr. 23267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, f\u00fcr Thermo TRACE 1300\/1310. 1600\/1610 GCs mit SSL Inlets, mit Quarzwolle, Premium-Deaktivierung, 5er Pack<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23267\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/28500\">                                Art.-Nr. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek elektronischer Leckdetektor<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/28500\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31615\">                                Art.-Nr. 31615                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC-MS Tuning Mix, 1000 \u03bcg\/mL, Methylenchlorid, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31615\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31025\">                                Art.-Nr. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">S\u00e4ure-Surrogat Mix (4\/89 SOW), 2000 \u03bcg\/mL, Methanol, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31025\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31024\">                                Art.-Nr. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Basenneutraler Surrogat Mix (4\/89 SOW), 1000 \u03bcg\/mL, Methylenchlorid, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31024\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31886\">                                Art.-Nr. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revidierter SV Interner Standard Mix, 4000 \u03bcg\/mL, Methylenchlorid, 1 mL\/Ampulle<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/31886\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die Analyse halbfl\u00fcchtiger Verbindungen ist weltweit eine grundlegende Applikation in Umweltpr\u00fcflabors. Da sich halbfl\u00fcchtige Verbindungen in Zusammensetzung und Reaktivit\u00e4t stark unterscheiden, werden sie h\u00e4ufig auf unterschiedlichen S\u00e4ulen analysiert. K\u00f6nnte man diese Anwendungen auf einer einzigen S\u00e4ule zusammenf\u00fchren, lie\u00dfe sich der Analyseaufwand deutlich reduzieren. Ob das gelingt, entscheidet die Wirksamkeit der GC-S\u00e4ulendeaktivierung. Herk\u00f6mmliche Deaktivierungsverfahren sind meist&#8230;<\/p>\n","protected":false},"author":34,"featured_media":62377,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[2746],"industries-application":[2235,2232,2230],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324,2328,2363],"ppma_author":[454,441,2657,452],"class_list":["post-86246","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","tag-rmx-resources","industries-application-testung-von-boden-sediment-organismen","industries-application-trinkwasser-abwasseruntersuchungen","industries-application-umweltbereich","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc","resource-technique-massenspektrometrie-ms","resource-technique-ms-ms-de"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"post_tag":[{"value":2746,"label":"RMX Ressourcen"}],"industries-application":[{"value":2235,"label":"Testung von Boden, Sediment, Organismen"},{"value":2232,"label":"Trinkwasser- und Abwasseruntersuchungen"},{"value":2230,"label":"Umweltbereich"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"},{"value":2328,"label":"Massenspektrometrie (MS)"},{"value":2363,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA5253-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/de\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":787,"category_count":511,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":[{"term_id":2746,"name":"RMX Ressourcen","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2746,"taxonomy":"post_tag","description":"Jetzt RMX Ressourcen entdecken","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/86246","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=86246"}],"version-history":[{"count":23,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/86246\/revisions"}],"predecessor-version":[{"id":95657,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/86246\/revisions\/95657"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/62377"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=86246"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=86246"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=86246"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=86246"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=86246"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=86246"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=86246"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=86246"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=86246"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}