{"id":90065,"date":"2026-01-26T12:37:22","date_gmt":"2026-01-26T12:37:22","guid":{"rendered":"https:\/\/discover.restek.com\/?p=90065"},"modified":"2026-03-31T12:20:32","modified_gmt":"2026-03-31T12:20:32","slug":"maximieren-sie-ihr-vertrauen-in-ihre-forensische-drogenanalytik-durch-gc-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/de\/artikel\/cffa4918-de\/maximieren-sie-ihr-vertrauen-in-ihre-forensische-drogenanalytik-durch-gc-ms","title":{"rendered":"Maximieren Sie Ihr Vertrauen in Ihre forensische Drogenanalytik durch GC-MS"},"content":{"rendered":"\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Die Next-Gen TriMax-Deaktivierung der S\u00e4ule schafft eine robuste neutrale Oberfl\u00e4che und einen au\u00dfergew\u00f6hnlich inerten Probenflussweg.<\/li>\n\n\n\n<li>Maximale Inertheit verbessert die Peak-Symmetrie f\u00fcr eine Vielzahl von schwer zu analysierenden Wirkstoff-Klassen.<\/li>\n\n\n\n<li>Stabile, symmetrische Peaks erm\u00f6glichen eine zuverl\u00e4ssigere Identifizierung selbst analytisch anspruchsvoller Arzneistoffe.<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-de\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE.png\" alt=\"\" class=\"wp-image-84593\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE_DE-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-de\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"127\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE.png\" alt=\"\" class=\"wp-image-84599\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES_DE-300x50.png 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">In der forensischen Drogenanalytik werden unbekannte Substanzen h\u00e4ufig mittels GC-MS analysiert, um ihre rechtliche Einstufung als illegale Droge zu bestimmen, wobei die Wahl der GC-S\u00e4ule ma\u00dfgeblich die Datenqualit\u00e4t und die Robustheit der Methode beeinflusst. Da eine Vielzahl von chemischen Verbindungen identifiziert werden m\u00fcssen, sind S\u00e4ulen mit mittlerer Polarit\u00e4t, wie z. B. S\u00e4ulen vom Typ \u201e5\u201c, eine h\u00e4ufige Wahl f\u00fcr die   Arzneimittelanalyse. Silarylenpolymere sind strukturell modifizierte 5er-Phasen, die eine verbesserte thermische Stabilit\u00e4t bieten, was eine &#8220;5-Sil&#8221;-S\u00e4ule zur perfekten Wahl f\u00fcr eine l\u00e4ngere Lebensdauer und eine konstante Leistung mit einem Massenspektrometer macht. Bei der Analyse solch eines breiten Spektrums an Bet\u00e4ubungsmitteln zeigen einige Wirkstoffklassen ungew\u00fcnschte Effekte, wie Peaktailing oder schwankende Retentionszeiten. Dies kann die Identifizierung erschweren. Saure Verbindungen (z. B. Barbiturate) neigen zu einer ungleichm\u00e4\u00dfigen Verteilung zwischen mobiler und station\u00e4rer Phase in der GC-S\u00e4ule. Grund daf\u00fcr sind starke Wechselwirkungen zwischen den schwach sauren N\u2013H-Gruppen der Barbituratmolek\u00fcle und den Silanolgruppen (\u2013Si\u2013OH) auf der Oberfl\u00e4che der kapillaren S\u00e4ule. Andere Arzneimittel weisen basische Funktionalit\u00e4ten auf (z. B. Amine). Auch hier k\u00f6nnen sich Wasserstoffbr\u00fcckenbindungen mit der Oberfl\u00e4che bilden, die die Verteilung zwischen station\u00e4rer und mobiler Phase verz\u00f6gern oder dazu f\u00fchren, dass manche Analyten vollst\u00e4ndig adsorbiert werden. Werden die Oberfl\u00e4chen-Silanol-Wechselwirkungen unterbunden, k\u00f6nnen forensische Labore bessere Ergebnisse f\u00fcr problematische Verbindungen mit vielen Funktionalit\u00e4ten erzielen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Um die Auswirkungen von Silanolen zu minimieren, hat Restek eine Next-Gen-TriMax-Deaktivierung entwickelt, die in allen RMX-S\u00e4ulen verwendet wird. Diese revolution\u00e4re Oberfl\u00e4chenbehandlung schafft eine robuste, hochgradig inerte Oberfl\u00e4che, die die Peak-Form f\u00fcr eine Vielzahl von Wirkstoffklassen verbessert. Dar\u00fcber hinaus k\u00f6nnen Sie darauf vertrauen, das jede S\u00e4ule einzeln mit sauren, basischen und neutralen Verbindungen QC-getestet wird, um die Wirksamkeit der Deaktivierung und die Prozesskontrolle zu gew\u00e4hrleisten. Dies macht RMX-5Sil MS-S\u00e4ulen &#8211; die eine 5Sil-Polarit\u00e4t mit hoher thermischer Stabilit\u00e4t und maximaler Oberfl\u00e4chen-Inertheit kombinieren &#8211; ideal f\u00fcr die<br>Verbesserung Ihrer forensischen Drogenanalytik (Abbildung 1). Wie in Abbildung 2 gezeigt, \u00fcbertrifft die RMX-5Sil MS-S\u00e4ule die Premium-S\u00e4ulen der Konkurrenz, wenn die Peakformen mehrerer schwieriger basischer Analyten (Doxylamin, Cyclobenzaprin, Codein) sowie eines schwach sauren Analyten (Alprazolam) verglichen wird. Unter den gleichen Instrumentenbedingungen sehen wir eine bessere Peakform, die nur auf die maximale Inertheit der RMX-5Sil MS-S\u00e4ulenoberfl\u00e4che zur\u00fcckzuf\u00fchren ist. Es gibt keine sekund\u00e4ren Wechselwirkungen zwischen Analyt und Silanolen, die ansonsten zu Peak-Tailing und schlechter Symmetrie f\u00fchren w\u00fcrden.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image90065_0a203e-ae .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image90065_0a203e-ae\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.restek.com\/c\/1484\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-1024x177.png\" alt=\"\" class=\"kb-img wp-image-91767\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-1024x177.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-300x52.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE-768x133.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-HTML-Block-with-Topaz-Liners_DE.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung 1: <\/strong>RMX-5Sil MS-S\u00e4ulen liefern hervorragende chromatographische Ergebnisse f\u00fcr 34 Bet\u00e4ubungsmittel, die in weniger als 21 Minuten mittels GC-MS analysiert werden.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1185.png\" alt=\"Acid, Base, and Neutral Drugs and Metabolites on RMX-5Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CF1185<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propofol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2078-54-8\/Propofol\" target=\"_blank\" rel=\"noopener\">Propofol<\/a><\/td><td class=\"oth\">2.53<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benzocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-09-7\/Benzocaine\" target=\"_blank\" rel=\"noopener\">Benzocaine<\/a><\/td><td class=\"oth\">4.73<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butabarbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-40-6\/Butabarbital\" target=\"_blank\" rel=\"noopener\">Butabarbital<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Butalbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-26-9\/Butalbital\" target=\"_blank\" rel=\"noopener\">Butalbital<\/a><\/td><td class=\"oth\">6.33<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenacetin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-44-2\/Phenacetin\" target=\"_blank\" rel=\"noopener\">Phenacetin<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cotinine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/486-56-6\/Cotinine\" target=\"_blank\" rel=\"noopener\">Cotinine<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amobarbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57-43-2\/Amobarbital\" target=\"_blank\" rel=\"noopener\">Amobarbital<\/a><\/td><td class=\"oth\">7.17<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentobarbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-74-4\/Pentobarbital\" target=\"_blank\" rel=\"noopener\">Pentobarbital<\/a><\/td><td class=\"oth\">7.6<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Secobarbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-73-3\/Secobarbital\" target=\"_blank\" rel=\"noopener\">Secobarbital<\/a><\/td><td class=\"oth\">8.54<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79499-59-5\/Norketamine\" target=\"_blank\" rel=\"noopener\">Norketamine<\/a><\/td><td class=\"oth\">9.06<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prilocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/721-50-6\/Prilocaine\" target=\"_blank\" rel=\"noopener\">Prilocaine<\/a><\/td><td class=\"oth\">9.33<\/td><td class=\"oth\">25<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ketamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/6740-88-1\/Ketamine\" target=\"_blank\" rel=\"noopener\">Ketamine<\/a><\/td><td class=\"oth\">9.71<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenhydramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-73-1\/Diphenhydramine\" target=\"_blank\" rel=\"noopener\">Diphenhydramine<\/a><\/td><td class=\"oth\">10.02<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phencyclidine (PCP)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77-10-1\/Phencyclidine\" target=\"_blank\" rel=\"noopener\">Phencyclidine (PCP)<\/a><\/td><td class=\"oth\">10.54<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Doxylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469-21-6\/Doxylamine\" target=\"_blank\" rel=\"noopener\">Doxylamine<\/a><\/td><td class=\"oth\">10.97<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tramadol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27203-92-5\/Tramadol\" target=\"_blank\" rel=\"noopener\">Tramadol<\/a><\/td><td class=\"oth\">11.7<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenobarbital\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-06-6\/Phenobarbital\" target=\"_blank\" rel=\"noopener\">Phenobarbital<\/a><\/td><td class=\"oth\">12.12<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpheniramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/132-22-9\/Chlorpheniramine\" target=\"_blank\" rel=\"noopener\">Chlorpheniramine<\/a><\/td><td class=\"oth\">12.92<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Procaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59-46-1\/Procaine\" target=\"_blank\" rel=\"noopener\">Procaine<\/a><\/td><td class=\"oth\">13.39<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Venlafaxine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93413-69-5\/Venlafaxine\" target=\"_blank\" rel=\"noopener\">Venlafaxine<\/a><\/td><td class=\"oth\">14.65<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Brompheniramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-22-6\/Brompheniramine\" target=\"_blank\" rel=\"noopener\">Brompheniramine<\/a><\/td><td class=\"oth\">15.02<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methadone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-99-3\/Methadone\" target=\"_blank\" rel=\"noopener\">Methadone<\/a><\/td><td class=\"oth\">15.64<\/td><td class=\"oth\">25<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dextromethorphan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/125-71-3\/Dextromethorphan\" target=\"_blank\" rel=\"noopener\">Dextromethorphan<\/a><\/td><td class=\"oth\">15.69<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Amitriptyline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-48-6\/Amitriptyline\" target=\"_blank\" rel=\"noopener\">Amitriptyline<\/a><\/td><td class=\"oth\">16.70<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cocaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-36-2\/Cocaine\" target=\"_blank\" rel=\"noopener\">Cocaine<\/a><\/td><td class=\"oth\">16.82<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imipramine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-49-7\/Imipramine\" target=\"_blank\" rel=\"noopener\">Imipramine<\/a><\/td><td class=\"oth\">17.03<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetracaine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/94-24-6\/Tetracaine\" target=\"_blank\" rel=\"noopener\">Tetracaine<\/a><\/td><td class=\"oth\">17.17<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclobenzaprine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-53-7\/Cyclobenzaprine\" target=\"_blank\" rel=\"noopener\">Cyclobenzaprine<\/a><\/td><td class=\"oth\">17.24<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sertraline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79617-96-2\/Sertraline\" target=\"_blank\" rel=\"noopener\">Sertraline<\/a><\/td><td class=\"oth\">18.16<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine<\/a><\/td><td class=\"oth\">18.29<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 6-Acetylmorphine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2784-73-8\/6-Acetylmorphine\" target=\"_blank\" rel=\"noopener\">6-Acetylmorphine<\/a><\/td><td class=\"oth\">18.96<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heroin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/561-27-3\/Heroin\" target=\"_blank\" rel=\"noopener\">Heroin<\/a><\/td><td class=\"oth\">19.38<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Zolpidem\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82626-48-0\/Zolpidem\" target=\"_blank\" rel=\"noopener\">Zolpidem<\/a><\/td><td class=\"oth\">19.97<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28981-97-7\/Alprazolam\" target=\"_blank\" rel=\"noopener\">Alprazolam<\/a><\/td><td class=\"oth\">20.53<\/td><td class=\"oth\">25<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>RMX-5Sil MS, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Ethyl acetate<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>25 ppm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4 mm single taper inlet liner with wool  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>25 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>150 &#176;C (hold 1.0 min) to 210 &#176;C at 4 &#176;C\/min to 320 &#176;C at 30 &#176;C\/min (hold 2.0 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.0 mL\/min<tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>54 cm\/sec @ 150 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>1.0<\/td><td>40-500<\/td><td>1562<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Individual standards (100 ppm) were combined into a final 25 ppm solution in ethyl acetate.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>17323<\/li><li>23303<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>forensic<\/li><li>seized drugs<\/li><li>toxicology<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1185.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Abbildung<\/strong> <strong>2: <\/strong>Hochinerte RMX-5Sil MS-S\u00e4ulen verbessern die Peakform f\u00fcr anspruchsvolle saure und basische Bet\u00e4ubungsmittel und vereinfachen die Identifizierung.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1186.png\" alt=\"Comparison of Seized Drugs on RMX-5Sil MS and a Premium Competitor Column (Zooms)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CF1186<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(\u00b5g\/mL)<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min) for RMX-5Sil MS<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min) for Premium Competitor Column<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Doxylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/469-21-6\/Doxylamine\" target=\"_blank\" rel=\"noopener\">Doxylamine<\/a><\/td><td class=\"oth\">25<\/td><td class=\"oth\">10.97<\/td><td class=\"oth\">11.54<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyclobenzaprine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/303-53-7\/Cyclobenzaprine\" target=\"_blank\" rel=\"noopener\">Cyclobenzaprine<\/a><\/td><td class=\"oth\">25<\/td><td class=\"oth\">17.24<\/td><td class=\"oth\">17.54<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Codeine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-57-3\/Codeine\" target=\"_blank\" rel=\"noopener\">Codeine<\/a><\/td><td class=\"oth\">25<\/td><td class=\"oth\">18.29<\/td><td class=\"oth\">18.53<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alprazolam\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28981-97-7\/Alprazolam\" target=\"_blank\" rel=\"noopener\">Alprazolam<\/a><\/td><td class=\"oth\">25<\/td><td class=\"oth\">20.53<\/td><td class=\"oth\">20.83<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes for names, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Ethyl acetate<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>25 ppm<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L split (split ratio 10:1)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4 mm single taper inlet liner with wool  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Split Vent Flow Rate:<\/th><td>25 mL\/min<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>150 &#176;C (hold 1.0 min) to 210 &#176;C at 4 &#176;C\/min to 320 &#176;C at 30 &#176;C\/min (hold 2.0 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2.0 mL\/min<tr><th class=\"sub conditions_header\" scope=\"row\">Linear Velocity:<\/th><td>54 cm\/sec @ 150 \u00b0C<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Scan Program:<\/th><td><\/td><\/tr><tr><td style=\"text-align:left\" colspan=\"2\"><table class=\"conditions_sim\"><thead><tr><th style=\"padding: 0 5px\">Group<\/th><th style=\"padding: 0 5px\">Start Time<br \/>(min)<\/th><th style=\"padding: 0 5px\">Scan Range<br \/>(amu)<\/th><th style=\"padding: 0 5px\">Scan Rate<br \/>(scans\/sec)<\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>1.0<\/td><td>40-500<\/td><td>1562<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Individual standards (100 ppm) were combined into a final 25 ppm in ethyl acetate.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>Columns tested: RMX-5Sil MS (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/17323\" rel=\"noopener\">cat.# 17323<\/a>) and a premium competitor column<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>23303<\/li><li>17323<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>forensic<\/li><li>seized drugs<\/li><li>toxicology<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1186.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/articles\/gnot3445\/ezgc-online-tools\" target=\"_blank\" rel=\" noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE.png\" alt=\"\" class=\"wp-image-84606\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block_DE-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2040\" height=\"1976\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE.png\" alt=\"\" class=\"wp-image-84612\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE.png 2040w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-300x291.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-1024x992.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-768x744.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-What-Makes-RMX-Better-HTML-1-DE-1536x1488.png 1536w\" sizes=\"auto, (max-width: 2040px) 100vw, 2040px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Empfohlene Produkte<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/17323\">                                Art.-Nr. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC Kapillars\u00e4ule, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/17323\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23303\">                                Art.-Nr. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, f\u00fcr Agilent GCs, mit Quarzwolle, Premium-Deaktivierung, 5er Pack<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/23303\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/28500\">                                Art.-Nr. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek elektronischer Leckdetektor<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/de.restek.com\/p\/28500\">Produkt anzeigen<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Die Analyse unbekannter Substanzen in der forensischen Drogenanalytik mittels GC-MS kann durch RMX-5Sil MS S\u00e4ulen verbessert werden, da die au\u00dfergew\u00f6hnlich inerte Oberfl\u00e4che das Peak-Tailing reduziert und die Peakform f\u00fcr eine Vielzahl von Arzneistoffen verbessert.<\/p>\n","protected":false},"author":26,"featured_media":61162,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[2746],"industries-application":[2239,2240,2223,2226],"post-badge":[],"resource-type":[],"product-library":[2480,2492],"resource-technique":[2324,2328],"ppma_author":[446,454,2657,452],"class_list":["post-90065","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","tag-rmx-resources","industries-application-forensik","industries-application-forensische-toxikologie","industries-application-klinisch","industries-application-klinische-toxikologie","product-library-gaschromatographie-produkte","product-library-gc-saulen","resource-technique-gaschromatographie-gc","resource-technique-massenspektrometrie-ms"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"post_tag":[{"value":2746,"label":"RMX Ressourcen"}],"industries-application":[{"value":2239,"label":"Forensik"},{"value":2240,"label":"Forensische Toxikologie"},{"value":2223,"label":"Klinisch"},{"value":2226,"label":"Klinische Toxikologie"}],"product-library":[{"value":2480,"label":"Gaschromatographie Produkte"},{"value":2492,"label":"GC S\u00e4ulen"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"},{"value":2328,"label":"Massenspektrometrie (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFFA4918-1024x568.jpg",1024,568,true],"author_info":{"display_name":"Corby Hilliard","author_link":"https:\/\/discover.restek.com\/de\/author\/corby-hilliard\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":787,"category_count":510,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":[{"term_id":2746,"name":"RMX Ressourcen","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2746,"taxonomy":"post_tag","description":"Jetzt RMX Ressourcen entdecken","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":446,"user_id":26,"is_guest":0,"slug":"corby-hilliard","display_name":"Corby Hilliard","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg"},"author_category":"1","first_name":"Corby","last_name":"Hilliard","user_url":"https:\/\/www.linkedin.com\/in\/corby-hilliard-69b1ba275\/","job_title":"Advanced Scientist, GC Applied","description":"Corby Hilliard started his Restek career in the Quality Assurance department where he spent his first seven years as a QA analyst and worked his way up to a senior QA analyst. He then moved on to the Innovations department in 2009 as a GC Solutions Advanced Scientist. His experience is predominately in gas chromatography (GC) using various detectors and mass spectrometry as well as troubleshooting and method development. His primary work for Restek is generating product application data, using new and existing products in food safety, petrochemical, environmental, and the GC accessories line. He also is involved with quality and R&amp;D as well as new product development."},{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/90065","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/comments?post=90065"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/90065\/revisions"}],"predecessor-version":[{"id":91773,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/posts\/90065\/revisions\/91773"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media\/61162"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/media?parent=90065"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/categories?post=90065"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/tags?post=90065"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/industries-application?post=90065"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/post-badge?post=90065"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-type?post=90065"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/product-library?post=90065"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/resource-technique?post=90065"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/de\/wp-json\/wp\/v2\/ppma_author?post=90065"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}