- Less retention of nonpolar analytes for faster analysis times.
- Proprietary column packing of superficially porous particles (SPP) and premium hardware.
- Superior performance in cannabis, food, clinical, and environmental testing.
Restek’s Raptor C8 columns boast the dependability of our Raptor line with the capability of achieving even faster analysis times compared to C18 columns. Defined by superior ruggedness and reproducibility, Raptor columns are the go-to choice for even the most challenging workflows.
Featuring SPP core-shell” technology and a highly-selective monomeric octylsilane phase, our Raptor C8 column is a high-performing, general-purpose column for cannabis, food, clinical, and environmental testing. With a shorter alkyl chain than a traditional C18 column, this Raptor C8 boasts increased analysis speeds and improved peak shape. Like all of our Raptor columns, this Raptor C8 is exceptionally durable with long column lifetimes and dependable reproducibility.
Learn more about our Raptor column line.

Stationary Phase Category:
C8, octylsilane (L7)
Ligand Type:
C8
Particle:
2.7 µm superficially porous particle
Pore Size:
90 Å
Surface Area:
130 m2/g
Recommended Usage:
pH Range: 2.0–8.0
Maximum Temperature: 80 °C
Maximum Pressure: 600 bar/8700 ps
Properties:
- Similar selectivity to C18 with less retention of nonpolar analytes for faster analysis times.
- Part of Restek’s Raptor LC column line featuring 2.7 µm SPP core-shell silica.
When to switch to C8:
- You want to achieve faster analysis times.
- Want less retention of non-polar analytes.
Column Interaction Profile:

Defining Solute Interactions:
- Dispersion
Solute Retention Profile:

Target Analyte Structures:
- Hydrocarbons
Target Analyte Functionalities:
- Hydrophobic compounds
PEth Homologues in Whole Blood on Raptor C8: Excellent Column Lifetimes and Lot-to-Lot Reproducibility with No Carryover
Using the Raptor C8 column, a robust and accurate analysis of the two most predominant phosphatidylethanol (PEth) homologues in whole blood was developed using a simple protein precipitation. PEth compounds are prone to carryover, but when utilizing the Raptor C8 column, no carryover was detected (Figure 1). Additionally, the Raptor C8 column demonstrated long column lifetimes and exceptional reproducibility from lot-to-lot (Figures 2 and 3).
View the full PEth application here.

LC_CF0823
Peaks
| Peaks | tR (min) | Precursor Ion | Product Ion 1 | Product Ion 2 | |
|---|---|---|---|---|---|
| 1. | Phosphatidylethanol 16:0/18:2 | 2.37 | 699.50 | 279.25 | 255.15 |
| 2. | Phosphatidylethanol 16:0/18:2-d5 | 2.37 | 704.50 | 279.35 | – |
| 3. | Phosphatidylethanol 16:0/18:1 | 2.63 | 701.00 | 281.25 | 255.20 |
| 4. | Phosphatidylethanol 16:0/18:1-d5 | 2.63 | 706.50 | 281.15 | – |
Conditions
| Column | Raptor C8 (cat.# 9303A52) | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions: | 50 mm x 2.1 mm ID | ||||||||||||||||||||||||||||||||
| Particle Size: | 2.7 µm | ||||||||||||||||||||||||||||||||
| Pore Size: | 90 Å | ||||||||||||||||||||||||||||||||
| Guard Column: | Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9303A0252) | ||||||||||||||||||||||||||||||||
| Temp.: | 30 °C | ||||||||||||||||||||||||||||||||
| Standard/Sample | |||||||||||||||||||||||||||||||||
| Diluent: | 4:1 2-propanol:tetrahydrofuran | ||||||||||||||||||||||||||||||||
| Conc.: | 1000 ng/mL in whole blood | ||||||||||||||||||||||||||||||||
| Inj. Vol.: | 5 µL | ||||||||||||||||||||||||||||||||
| Mobile Phase | |||||||||||||||||||||||||||||||||
| A: | 5 mM Ammonium acetate, water | ||||||||||||||||||||||||||||||||
| B: | 90:10 Acetonitrile:2-propanol | ||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||
| Max Pressure: | 210 bar |
| Detector | Shimadzu 8060 MS/MS |
|---|---|
| Ion Source: | Electrospray |
| Ion Mode: | ESI- |
| Mode: | MRM |
| Instrument | Shimadzu Nexera X2 |
| Sample Preparation | Procedure provided by RedHot Diagnostics: The fortified blood sample (50 µL) was mixed with 50 µL of internal standard and 150 µL of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (cat.# 21143) with a glass insert (cat.# 21776) and capped with short-cap, screw-vial closure (cat.# 24498). Five microliters was injected for analysis. |

LC_CF0824
Peaks
| Peaks | Precursor Ion | Product Ion 1 | Product Ion 2 | |
|---|---|---|---|---|
| 1. | Phosphatidylethanol 16:0/18:2 | 699.50 | 279.25 | 255.15 |
Conditions
| Column | Raptor C8 (cat.# 9303A52) | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions: | 50 mm x 2.1 mm ID | ||||||||||||||||||||||||||||||||
| Particle Size: | 2.7 µm | ||||||||||||||||||||||||||||||||
| Pore Size: | 90 Å | ||||||||||||||||||||||||||||||||
| Guard Column: | Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9303A0252) | ||||||||||||||||||||||||||||||||
| Temp.: | 30 °C | ||||||||||||||||||||||||||||||||
| Standard/Sample | |||||||||||||||||||||||||||||||||
| Diluent: | 4:1 2-propanol:tetrahydrofuran | ||||||||||||||||||||||||||||||||
| Conc.: | 100 ng/mL in whole blood | ||||||||||||||||||||||||||||||||
| Inj. Vol.: | 5 µL | ||||||||||||||||||||||||||||||||
| Mobile Phase | |||||||||||||||||||||||||||||||||
| A: | 5 mM Ammonium acetate, water | ||||||||||||||||||||||||||||||||
| B: | 90:10 Acetonitrile:2-propanol | ||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||
| Max Pressure: | 210 bar |
| Detector | Shimadzu 8060 MS/MS |
|---|---|
| Ion Source: | Electrospray |
| Ion Mode: | ESI- |
| Mode: | MRM |
| Instrument | Shimadzu Nexera X2 |
| Sample Preparation | Procedure provided by RedHot Diagnostics: The fortified blood sample (50 µL) was mixed with 50 µL of internal standard and 150 µL of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (cat.# 21143) with a glass insert (cat.# 21776) and capped with a short-cap, screw-vial closure (cat.# 24498). Five microliters was injected for analysis. |

LC_CF0825
Peaks
| Peaks | Precursor Ion | Product Ion 1 | Product Ion 2 | |
|---|---|---|---|---|
| 1. | Phosphatidylethanol 16:0/18:2 | 699.50 | 279.25 | 255.15 |
Conditions
| Column | Raptor C8 (cat.# 9303A52) | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dimensions: | 50 mm x 2.1 mm ID | ||||||||||||||||||||||||||||||||
| Particle Size: | 2.7 µm | ||||||||||||||||||||||||||||||||
| Pore Size: | 90 Å | ||||||||||||||||||||||||||||||||
| Guard Column: | Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 µm (cat.# 9303A0252) | ||||||||||||||||||||||||||||||||
| Temp.: | 30 °C | ||||||||||||||||||||||||||||||||
| Standard/Sample | |||||||||||||||||||||||||||||||||
| Diluent: | 4:1 2-propanol:tetrahydrofuran | ||||||||||||||||||||||||||||||||
| Conc.: | 100 ng/mL in whole blood | ||||||||||||||||||||||||||||||||
| Inj. Vol.: | 5 µL | ||||||||||||||||||||||||||||||||
| Mobile Phase | |||||||||||||||||||||||||||||||||
| A: | 5 mM Ammonium acetate, water | ||||||||||||||||||||||||||||||||
| B: | 90:10 Acetonitrile:2-propanol | ||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||
| Max Pressure: | 210 bar |
| Detector | Shimadzu 8060 MS/MS |
|---|---|
| Ion Source: | Electrospray |
| Ion Mode: | ESI- |
| Mode: | MRM |
| Instrument | Shimadzu Nexera X2 |
| Sample Preparation | Procedure provided by RedHot Diagnostics: The fortified blood sample (50 µL) was mixed with 50 µL of internal standard and 150 µL of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (cat.# 21143) with a glass insert (cat.# 21776) and capped with a short-cap, screw-vial closure (cat.# 24498). Five microliters was injected for analysis. |