{"id":42414,"date":"2019-12-23T05:00:00","date_gmt":"2019-12-23T05:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/what-is-quechers-video-article\/"},"modified":"2026-08-11T18:24:44","modified_gmt":"2026-08-11T18:24:44","slug":"what-is-quechers-video-article","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/videos-zh\/ffav3667\/what-is-quechers-video-article","title":{"rendered":"What is QuEChERS?"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"What is QuEChERS?\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/2lJxT-tAgpk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/c\/1134\" target=\"_blank\" rel=\"noopener\">QuEChERS<\/a> is a sample preparation technique that vastly simplifies the analysis of pesticide residues. It&#8217;s quick, easy, cheap, effective, rugged, and safe. In this video, we&#8217;ll show you the two primary steps of the QuEChERS\u00a0method:\u00a0the\u00a0extraction of\u00a0your analytes of interest\u00a0using extraction salts,\u00a0followed by\u00a0the cleanup\u00a0of\u00a0your supernatant\u00a0using\u00a0dSPE. Let\u2019s get started!<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/articles\/quechers-made-even-easier\" target=\"_blank\" rel=\"noopener\">Restek QuEChERS<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/chromablography\/how-can-you-make-food-homogenization-less-of-a-grind\" target=\"_blank\" rel=\"noopener\">How Can You Make Food Homogenization Less of a Grind?<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/fdc.nal.usda.gov\/\" target=\"_blank\" rel=\"noreferrer noopener\">USDA Nutrient Database<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1344\" target=\"_blank\" rel=\"noopener\">Restek Q-sep Extraction Salts<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1343\" target=\"_blank\" rel=\"noopener\">Restek Q-sep dSPE<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1626\" target=\"_blank\" rel=\"noopener\">Restek Empty Centrifuge Tubes, Polypropylene<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">What is QuEChERS?&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">From fruits and vegetables to grains, pesticide residue analysis covers a wide variety of commodities. It can be an expensive and time-consuming task,&nbsp;requiring a high level of consistency to deliver reliable results.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">QuEChERS is a sample preparation technique that vastly simplifies the analysis of pesticide residues.&nbsp;It\u2019s quick, easy, cheap, effective, rugged, and safe. And it can even be modified to work with other commodities,&nbsp;from analyzing mycotoxins in beer to monitoring pharmaceuticals in fish.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">QuEChERS can primarily be thought of as a two-step process:&nbsp;The first step is Extraction, where analytes of interest are extracted from your sample.&nbsp;And the second step is Cleanup, where&nbsp;many potential interferences are removed from the&nbsp;extract.&nbsp;A variety of QuEChERS methods exist to help ensure the efficient extraction of different types of compounds. While these methods vary in specific procedure, the general QuEChERS process follows the same path.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">We\u2019ll begin our extraction step by homogenizing the food matrix. This generates a uniform sample that represents the whole product, and improves the extraction efficiency of the desired analytes.&nbsp;Once homogenized, add your sample to a centrifuge tube; then,&nbsp;add the solvent\u2014usually acetonitrile\u2014and shake vigorously.&nbsp;Next add the extraction salts.&nbsp;Shake the tube vigorously again,&nbsp;and now it\u2019s ready to be centrifuged.&nbsp;After the sample has spun down, take a look at your sample.&nbsp;You should see four distinct layers. From the top down, there\u2019s:&nbsp;The Supernatant,&nbsp;The Sample Solids,&nbsp;Water,&nbsp;and Excess Extraction Salt.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">During the extraction of your commodity in stage one, other potential interferences,&nbsp;such as sugars, fatty acids, organic acids, pigments, and lipids may still be present.&nbsp;So&nbsp;for stage two, it\u2019s time to use dispersive solid phase extraction media, or&nbsp;dSPE, to clean up your sample.&nbsp;Add your supernatant to the&nbsp;dSPE&nbsp;tube,&nbsp;shake vigorously,&nbsp;and then place it into a centrifuge.&nbsp;Once centrifugation is complete, transfer the supernatant into an autosampler vial and make any final adjustments required for your sample.&nbsp;And that\u2019s it\u2014you\u2019re done! Your sample is now ready to be analyzed.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">That\u2019s the power of QuEChERS\u2014a quick, easy, cheap, effective, rugged, and safe sample preparation technique perfectly suited to pesticide analysis.&nbsp;For more information about the QuEChERS approach, visit our website at&nbsp;<a href=\"https:\/\/www.restek.com\/articles\/quechers-made-even-easier\" target=\"_blank\" rel=\"noopener\">restek.com\/QuEChERS<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Have you heard of QuEChERS? It&#8217;s a quick, easy, cheap, effective, rugged, and safe sample preparation technique that vastly simplifies pesticide analysis. See the power and speed of QuEChERS in our latest video!<\/p>\n","protected":false},"author":11,"featured_media":40980,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[775],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42414","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-zh"],"acf":[],"taxonomy_info":{"category":[{"value":775,"label":"\u89c6\u9891"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAV3667-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":775,"name":"\u89c6\u9891","slug":"videos-zh","term_group":0,"term_taxonomy_id":775,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":775,"category_count":138,"category_description":"","cat_name":"\u89c6\u9891","category_nicename":"videos-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42414","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=42414"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42414\/revisions"}],"predecessor-version":[{"id":95576,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42414\/revisions\/95576"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/40980"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=42414"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=42414"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=42414"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=42414"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=42414"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=42414"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=42414"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=42414"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=42414"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}