{"id":42446,"date":"2020-10-13T18:30:00","date_gmt":"2020-10-13T18:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-particle-traps\/"},"modified":"2026-08-11T17:52:56","modified_gmt":"2026-08-11T17:52:56","slug":"gc-particle-traps","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/videos\/gnav3592\/gc-particle-traps","title":{"rendered":"GC Particle Traps"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"GC Particle Traps\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Yt6Nciq1lEE?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Description<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern PLOT columns offer incredible stability that minimizes particle release, but during transportation, gas flow changes,&nbsp;or valve switching, some particles may dislodge and release from the column.\u202f&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Particle traps are PDMS-coated columns designed to catch any particles that are released from a PLOT column.&nbsp;And in this Restek Tip, we\u2019re going to show you how to connect a particle trap to a PLOT column using a Press-Tight connector.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1179\" target=\"_blank\" rel=\"noreferrer noopener\">Restek&#8217;s PLOT Column Particle Trap<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/articles\/PCSS1163\/resteks-plot-column-family\/\">Restek&#8217;s PLOT Column Family<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1571\" target=\"_blank\" rel=\"noreferrer noopener\">Universal Press-Tight Connectors<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/p\/20445\" target=\"_blank\" rel=\"noopener\">Polyimide Resin<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Modern&nbsp;porous&nbsp;layer&nbsp;open&nbsp;tubular&nbsp;columns\u2014or&nbsp;PLOT columns\u2014offer&nbsp;incredible stability that minimizes particle release.&nbsp;Nevertheless, during transportation, gas flow changes, or valve switching, some particles may dislodge and release from the column.&nbsp;These particles can then cause spikes in the chromatogram or damage switching valves leading to time-consuming and costly side&nbsp;effects.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In this Restek Tip, we\u2019re going to look at connecting a GC PLOT column to a particle trap using a Press-Tight connector. Let\u2019s begin by exploring what a particle trap is and how it works.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Particle traps are PDMS-coated columns designed to catch any particles that are released from a PLOT column.&nbsp;For atmospheric pressure outlets such as valves, flow switching devices, or even FID and TCD detectors, half a meter to two meters of a particle trap column with the same ID as the PLOT column is sufficient.&nbsp;Whereas for mass spec detectors, a column length of five meters with a&nbsp;0.18 or&nbsp;0.25 millimeter ID is recommended. Not only will this aid in particle trapping, but it will also help manage the flow into the MS.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Prior to installing the particle trap, condition the PLOT column out of the detector using&nbsp;three&nbsp;times higher the column flow than your application suggests.&nbsp;We recommend programming the GC oven to heat up at 5\u00b0C&nbsp;per minute up to the column\u2019s maximum temperature. Once reached, hold this temperature for at least an hour\u2014this should allow any loose particles to elute from the column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now that conditioning is complete, it\u2019s time to cut the end of the PLOT column and the particle trap column. A scoring wafer should be used to achieve a straight, square cut, which is essential to correctly connect the Press-Tight connector.&nbsp;Next we\u2019ll prepare the PLOT column by lightly tapping, or flicking the end of the column with your fingers to remove any loose particles.&nbsp;Clean the ends of the PLOT column and the particle trap with a lint-free wipe moistened with methanol or isopropanol to remove&nbsp;any&nbsp;finger oils and&nbsp;any&nbsp;other impurities.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Now we\u2019ll connect the columns together using the Press-Tight connector.&nbsp;While holding the connector in one hand, gently insert the PLOT column end into the connector until it is gripped firmly.&nbsp;Be careful not to press too hard or the column end will crush.&nbsp;And now we\u2019ll simply repeat the process with the particle trap, gently inserting it into the other end of the connector.&nbsp;A&nbsp;continuous brown ring where the column end compresses inside the connector indicates a proper connection.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Visually inspect both seals and leak check the connections using an electronic leak detector. If you notice a leak, cut a small portion of the column in question and reconnect.&nbsp;And that\u2019s it\u2014you\u2019re ready to go. Decrease the column flow and you\u2019re set to start your analysis.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Please like and subscribe for more helpful content and thank you for joining us for this Restek Tip.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>What does a particle trap do? When would you use one? Check out our latest Restek Tip to see it in action!<\/p>\n","protected":false},"author":11,"featured_media":41046,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-42446","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3592-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":8,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=42446"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42446\/revisions"}],"predecessor-version":[{"id":78748,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42446\/revisions\/78748"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/41046"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=42446"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=42446"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=42446"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=42446"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=42446"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=42446"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=42446"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=42446"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=42446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}