{"id":42586,"date":"2018-05-16T04:00:00","date_gmt":"2018-05-16T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/choosing-the-right-quechers-extraction-salt\/"},"modified":"2025-11-17T15:56:54","modified_gmt":"2025-11-17T15:56:54","slug":"choosing-the-right-quechers-extraction-salt","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/videos\/gnav4890\/choosing-the-right-quechers-extraction-salt","title":{"rendered":"Choosing the Right QuEChERS Extraction Salt"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Choosing the Right QuEChERS Extraction Salt\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/_3tLlxnjMKk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Description&nbsp;<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QuEChERS (Quick, Easy, Cheap, Effective, Rugged,&nbsp;Safe) sample preparation has grown&nbsp;rapidly&nbsp;in popularity. Originally used for pesticide residue analysis in food commodities, this&nbsp;technique has expanded in to many other matrices. But,&nbsp;that can lead to tough questions, such as how to select the right salt mixture for an extraction. Here we share some information on how to make the best choice.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Additional Resources<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/articles\/quechers-made-even-easier\" target=\"_blank\" rel=\"noopener\">Restek QuEChERS Solutions<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek Recommended Tools &amp; Parts<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1344\" target=\"_blank\" rel=\"noopener\">Q-sep QuEChERS Extraction Salts<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1343\" target=\"_blank\" rel=\"noopener\">Q-Sep QuEChERS dSPE Tubes<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Transcript<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Hi, and welcome to this Restek&nbsp;Tip, where we\u2019ll be talking about QuEChERS&nbsp;extraction salt selection. So, you\u2019ve decided to try QuEChERS, awesome. You go, and you look for the products that you\u2019re going to need, and you\u2019re going to find that the extraction salts come in three basic varieties. There is the original method. And then there are two methods which represent revisions on the original method, named, the EN method and the AOAC. And they\u2019re just named after the bodies that published the specific methods.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, which one are you going to pick? To understand which of these two options, the revised methods or the original methods, you need to understand the distinction between the two. The original method is also sometimes referred to as the&nbsp;unbuffered&nbsp;method. So, what does that mean? Being&nbsp;unbuffered, it means that the final sample pH is going to be determined pretty much solely by the commodity. It will be what it will be.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In contrast to that, the two revisions, the EN and the AOAC, are both buffered methods, which means they have salts that are intended to specifically land at a range of pH that is going to be very stable for most pesticides. And that is a little bit below 5 for the AOAC method or around 5-5\u00bd pH for the EN method.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, which one still do you pick? If you have pesticides that are rock solid and will be stable regardless of the final sample pH, the original method will work great for you. And that\u2019s a lot of pesticides and a lot of matrices. However, if you have concerns about the stability of your sample due to the pH of the actual sample, then one of the buffered methods, and either will be a great place to start for your application, would be what you\u2019d want to choose.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So, good luck with your next QuEChERS&nbsp;extraction, and thanks for joining us for this Restek Tip.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>In this Restek Tip we\u2019re going to talk about #QuEChERS. With multiple options, how do you pick the right salt mixture for your extraction?<\/p>\n","protected":false},"author":11,"featured_media":41448,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[8],"tags":[],"industries-application":[2236,2238],"post-badge":[],"resource-type":[],"product-library":[2508,2483],"resource-technique":[2368],"ppma_author":[414],"class_list":["post-42586","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos","industries-application-lebensmittel-getranke","industries-application-lebensmittelsicherheit","product-library-quechers-produkte","product-library-produkte-zur-probenvorbereitung","resource-technique-quechers-de"],"acf":[],"taxonomy_info":{"category":[{"value":8,"label":"Videos"}],"industries-application":[{"value":2236,"label":"Lebensmittel &amp; Getr\u00e4nke"},{"value":2238,"label":"Lebensmittelsicherheit"}],"product-library":[{"value":2508,"label":"QuEChERS Produkte"},{"value":2483,"label":"Produkte zur Probenvorbereitung"}],"resource-technique":[{"value":2368,"label":"QuEChERS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4890-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":8,"name":"Videos","slug":"videos","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":138,"filter":"raw","cat_ID":8,"category_count":138,"category_description":"","cat_name":"Videos","category_nicename":"videos","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=42586"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42586\/revisions"}],"predecessor-version":[{"id":64932,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/42586\/revisions\/64932"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/41448"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=42586"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=42586"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=42586"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=42586"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=42586"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=42586"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=42586"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=42586"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=42586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}