{"id":43546,"date":"2020-10-21T00:00:00","date_gmt":"2020-10-21T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/improve-acrylamide-analysis-in-food-with-a-long-lasting-lc-column-and-a-cost-effective-internal-standard\/"},"modified":"2026-01-28T16:52:16","modified_gmt":"2026-01-28T16:52:16","slug":"improve-acrylamide-analysis-in-food-with-a-long-lasting-lc-column-and-a-cost-effective-internal-standard","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/artikel\/ffar3126\/improve-acrylamide-analysis-in-food-with-a-long-lasting-lc-column-and-a-cost-effective-internal-standard","title":{"rendered":"Improve Acrylamide Analysis in Food with a Long-Lasting LC Column and a Cost-Effective Internal Standard"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Acrylamide can form in food when sugars and the amino acid asparagine react during high-heat cooking processes like frying, roasting, grilling, or baking. Foods like potato chips\/crisps, grain-based baked goods, and coffee are examples of commodities that have been focal areas for characterizing acrylamide presence and concentration. The detection of acrylamide in food was first reported in 2002 by the Swedish National Food Administration, and since then global efforts have been growing to better understand its origin in food and feed, the magnitude of contamination in various foodstuffs, and the potential health effects related to dietary exposure. Acrylamide is classified as a very hazardous chemical, and large quantities of it have been shown to cause cancer in laboratory animals (although no direct link between dietary exposure and increased incidence of cancer in humans has been proven to date). To safeguard public health, scientists need more efficient acrylamide methods that allow them to accurately determine concentrations in foods and beverages. Here, we compare typical approaches to acrylamide analysis in food to an improved process using an Allure Acrylamide column and deuterated internal standard. Benefits include faster analysis times and longer periods of sample throughput without system suitability failures.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Current Analytical Approach<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">LC-MS\/MS is the Technique of Choice<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Accurate acrylamide analysis in food matrices has presented technical challenges. Initially, GC separations with mass spectrometric detection techniques were pursued because acrylamide is a small and relatively volatile compound. However, those techniques relied on the conversion of acrylamide into a brominated derivative, which was an undesirable step [1]. LC-MS\/MS techniques were explored and now are the most common analytical tool used in routine acrylamide analysis of food samples. LC-MS\/MS methods still face analytical hurdles, most notably with the selective retention of acrylamide and its separation from compounds that are coextracted from the complex matrices typically being studied.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Use of Porous Graphitized Carbon (PGC) LC Columns<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Europe has formalized a method for acrylamide analysis in food\u2014EN 16618:2015\u2014and it calls for the use of LC guard and analytical columns that contain porous graphitized carbon (PGC), in part because of the difficulty of analyzing acrylamide using more traditional reversed-phase (RP) retention mechanisms. PGC columns are now commonly used in the industry because they can retain acrylamide sufficiently to separate it from matrix components that may have been coextracted, even after the relatively rigorous EN method sample preparation procedure. The PGC column is also able to operate in 100% aqueous mobile phase, a condition under which many RP columns would undergo a phenomenon known as \u201cdewetting,\u201d which results in retention time loss and requires that the column be regenerated by a time-consuming flush with 100% organic mobile phase.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Use of Deuterated Internal Standards<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Accurate quantitation is imperative, but the extraction process can introduce considerable variation, so the use of internal standards that are added to the sample along with the extraction solvent is recommended by the EN method. The EN method includes the use of deuterated internal standards instead of the carbon-labeled internal standards that have also been commonly used for acrylamide analysis. Significantly less expensive than carbon-labeled acrylamide, acrylamide-d3 is an excellent and cost-effective choice for internal standard.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Method Requirements<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The time required for acrylamide analysis in food following method EN 16618:2015 is 8 minutes. To meet system suitability requirements, acrylamide must elute no earlier than 1.7 minutes, but the additional time spent after acrylamide elution is necessary to flush the column of matrix components that remained in the sample extract even after the two-step SPE sample preparation process outlined in the EN method. Matrix components are strongly retained on PGC columns, and if not sufficiently purged between analyses, can degrade performance to the point of failure to meet the 1.7-minute retention time system suitability requirement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">A Return to Reversed-Phase Retention Can Increase Sample Throughput<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As labs approach the system suitability threshold when using PGC columns, they are faced with the choice to either conduct the lengthy column regeneration procedure in the hope that they regain the ability to meet system suitability criteria, or they have to replace the current guard, and possibly the analytical column. Both are time-consuming and costly propositions that halt sample throughput. Switching to an Allure Acrylamide column is a better alternative: the proprietary reversed-phase chemistry incorporates a unique polar ligand that retains acrylamide, is compatible with 100% aqueous conditions, and offers faster run times and longer column lifetimes than PGC columns. Using an Allure Acrylamide guard column and analytical column provides the best balance between retaining acrylamide long enough to meet the EN system suitability requirement, while not retaining coextracted matrix compounds so strongly that they cannot be flushed from the column quickly between analyses. As a result, labs using Allure Acrylamide columns can analyze more samples using fewer columns\u2014a powerful savings combination for any food safety lab. The following examples illustrate the benefits of using an Allure Acrylamide column and guard, along with a deuterated internal standard, for high-throughput food safety labs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Shorter Analysis Times<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Because matrix compounds elute quickly from the Allure Acrylamide column, it is able to equilibrate and be ready for the next injection faster than even a PGC column run under optimized conditions. Figure 1 shows an example of two different methods for acrylamide analysis in food (potato chips in this case), one with an Allure Acrylamide column and one with a representative PGC column. The PGC column method was further optimized from the EN method, shortening the analysis time from 8 to 7 minutes, while still providing the optimal column flushing and equilibration time. Any further flushing provided no significant benefit to column lifetime. The acrylamide analysis on the Allure Acrylamide column met the method requirement of 1.7-minute retention with good separation from matrix components, but with much shorter equilibration times. A per analysis savings of 2.5 minutes compared to EN 16618:2015 and 1.5 minutes compared to the optimized PGC column method, allows more samples to be analyzed per shift, increasing lab output.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1<\/strong>: Labs can increase sample throughput using an Allure Acrylamide column because much less equilibration time is needed compared to an PGC column, even with a complex matrix like potato chips.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0532.png\" alt=\"Comparison: Acrylamide Extracted from Potato Chips on an Allure Acrylamide Column vs. a Porous Graphitized Carbon Column\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0532<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Acrylamide-d3 (IS)<\/td><td class=\"oth\">200<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrylamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79-06-1\/Acrylamide\" target=\"_blank\" rel=\"noopener\">Acrylamide<\/a><\/td><td class=\"oth\">Endogenous<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">55.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>22 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Acrylamide-d3<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td>A. 0.001% Formic acid in water, B. 0.001% formic acid in acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow:<\/th><td>0.4 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Extracted per EN 16618:2015<br \/><br \/>Weighed 2.0 g of homogenized potato chips into a 50 mL centrifuge tube. Added 40 mL water followed by the addition of internal standard. Shook by hand for 30 sec, by vortexer for 15 sec, and then on a mechanical shaker for 60 min set to maximum sample extraction agitation. Centrifuged in a refrigerated centrifuge at 10 \u00b0C, 3600 x g for 20 min. Removed the aqueous layer after centrifugation, taking care to avoid the top, fatty layer, or the solids at the bottom of the tube. Placed the aqueous extract in an appropriate container.<br \/><br \/>For cleanup, the first SPE cartridge (multimode SPE column with nonpolar, SAX, and SCX properties, 1000 mg\/6 mL) was conditioned with 3 mL methanol and x2, 6 mL aliquots of water. Passed 10 mL of the aqueous extract through the column and collected eluate. For the next cleanup step, the second SPE cartridge (crosslinked polystyrene\/poly-DVB SPE column, 500 mg\/6 mL) was conditioned with 5 mL methanol and 5 mL water. Passed the eluate from the previous step entirely through the column. Rinsed the loaded cartridge once with 4 mL water and discarded the rinsing solvent. Eluted the acrylamide with 2 mL of 60% methanol in water. Collected the sample and transferred into an evaporation tube. Placed the tube in an evaporator at a temperature no higher than 40 \u00b0C to remove the methanol. Evaporated until the final volume was 0.5\u20130.8 mL using a gentle flow of nitrogen. Transferred the final sample into an autosampler vial and analyzed by LC-MS\/MS.<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><b>Column Details<\/b><br \/>A. <i>Allure Acrylamide column<\/i>: 5 \u03bcm, 50 mm x 2.1 mm ID analytical column (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9167552\" rel=\"noopener\">cat.# 9167552<\/a>) with 5 \u03bcm, 10 mm x 2.1 mm ID guard cartridge (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/916750212\" rel=\"noopener\">cat.# 916750212<\/a>).<br \/>B. <i>Porous graphitized carbon column<\/i>: 5 \u03bcm, 50 mm x 2.1 mm ID analytical column with 5 \u03bcm, 10 mm x 2.1 mm ID guard cartridge.<br \/><br \/><b>Mobile Phase Gradients (%B)<\/b><br \/>A. <i>Allure Acrylamide column<\/i>: 0.00 min (0%), 1.00 min (0%), 2.00 min (90%), 2.01 min (0%), 5.50 min (0%), flow = 0.4 mL\/min.<br \/>B. <i>Porous graphitized carbon column<\/i>: 0.00 min (0%), 1.70 min (0%), 2.70 min (90%), 2.71 min (0%), 7.00 min (0%), flow = 0.4 mL\/min.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9167552<\/li><li>916750212<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Acrylamide<\/li><li>Chips<\/li><li>Potato<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0532.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Longer Column Lifetimes<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 2 illustrates the extreme stability of acrylamide retention time achieved with the Allure Acrylamide column compared to a representative PGC column, which shows loss of retention almost immediately and ultimately fails the 1.7 minute retention time requirement after 475 injections of a coffee sample, extracted and cleaned up per EN 16618:2015. In contrast, even after 1000 injections, the Allure Acrylamide performance remains steady and ready for the next injection. Figure 3 shows how the chromatography remains unaffected from the first to the thousandth injection on the Allure Acrylamide column. Its ability to elute coextracted matrix compounds rather than strongly retain them is the key to its extremely stable performance over hundreds and hundreds of repeat matrix injections with little to no column maintenance.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2<\/strong>: The Allure Acrylamide column still meets EN 16618:2015 system suitability requirements even after 1000 injections\u2014over twice as many passing injections than a typical PGC column.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<style>.kb-image43546_3b8e3f-91 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43546_3b8e3f-91\"><figure class=\"aligncenter size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"471\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02-768x471.jpg\" alt=\"\" class=\"kb-img wp-image-19870\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02-768x471.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02-300x184.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02-1024x629.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02-1536x943.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-FFAR3126A-UNV-02.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure><\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3<\/strong>: Even after 1000 injections of coffee extract, without any system maintenance or guard column replacement, the Allure Acrylamide column performance remains unchanged.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0533.png\" alt=\"Lifetime Test: EN16618:2015 Coffee Extract on Allure Acrylamide (1000th Injection)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0533<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Acrylamide-d3 (IS)<\/td><td class=\"oth\">200<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrylamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79-06-1\/Acrylamide\" target=\"_blank\" rel=\"noopener\">Acrylamide<\/a><\/td><td class=\"oth\">Endogenous<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">55.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Allure Acrylamide  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9167552\" rel=\"noopener\">cat.# 9167552<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>5 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>60 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Allure Acrylamide 10 mm, 2.1 mm ID, 5 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/916750212\" rel=\"noopener\">cat.# 916750212<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>22 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.001% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.001% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>1.00<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>2.00<\/td><td>0.4<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>2.01<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>5.50<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Extracted per EN 16618:2015<br \/><br \/>Weighed 2.0 g of ground coffee into a 50 mL centrifuge tube. Added 5 mL <i>n<\/i>-hexane and 40 mL water followed by the addition of internal standard. Shook by hand for 30 sec, by vortexer for 15 sec, and then on a mechanical shaker for 60 min set to maximum sample extraction agitation. Centrifuged in a refrigerated centrifuge at 10 \u00b0C, 3600 x g for 20 min. Removed the aqueous layer after centrifugation, taking care to avoid the top, hexane layer, or the solids at the bottom of the tube. Placed the aqueous extract in an appropriate container.<br \/><br \/>For cleanup, the first SPE cartridge (multimode SPE column with nonpolar, SAX and SCX properties, 1000 mg\/6 mL) was conditioned with 3 mL methanol and x2, 6 mL aliquots of water. Passed 10 mL of the aqueous extract through the column and collected eluate. For the next cleanup step, the second SPE cartridge (crosslinked polystyrene\/poly-DVB SPE column, 500 mg\/6 mL) was conditioned with 5 mL methanol and 5 mL water. Passed the eluate from the previous step entirely through the column. Rinsed the loaded cartridge once with 4 mL water and discarded the rinsing solvent. Eluted the acrylamide with 2 mL of 60% methanol in water. Collected the sample and transferred into an evaporation tube. Placed the tube in an evaporator at a temperature no higher than 40 \u00b0C to remove the methanol. Evaporated until the final volume was 0.5\u20130.8 mL using a gentle flow of nitrogen. Transferred the final sample into an autosampler vial and analyzed by LC-MS\/MS.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>916750212<\/li><li>9167552<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>16618<\/li><li>Acrylamide<\/li><li>Coffee<\/li><li>DIN<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0533.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Consistent Column-to-Column Performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Developed to withstand 100% aqueous mobile phases, Restek Allure Acrylamide guard and analytical columns deliver the same robust performance injection to injection, and also column to column. Our stringent manufacturing procedures and rigorous quality testing ensure that when it does come time to replace your Allure Acrylamide column, you\u2019ll get the same acrylamide analysis performance with the new column that you relied on with the old one (Figure 4).<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4<\/strong>: Rugged reversed-phase Allure Acrylamide LC columns deliver reproducible results column to column and lot to lot.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0534.png\" alt=\"Lot-to-Lot Reproducibility of Allure Acrylamide\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_FS0534<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Acrylamide-d3 (IS)<\/td><td class=\"oth\">200<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">58.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrylamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79-06-1\/Acrylamide\" target=\"_blank\" rel=\"noopener\">Acrylamide<\/a><\/td><td class=\"oth\">200<\/td><td class=\"oth\">72.1<\/td><td class=\"oth\">55.1<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Allure Acrylamide  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9167552\" rel=\"noopener\">cat.# 9167552<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>5 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>60 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Allure Acrylamide 10 mm, 2.1 mm ID, 5 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/916750212\" rel=\"noopener\">cat.# 916750212<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>22 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>Acrylamide (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/30494\" rel=\"noopener\">cat.# 30494<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Water<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>10 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>0.001% Formic acid in water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>0.001% Formic acid in acetonitrile <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>1.00<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>2.00<\/td><td>0.4<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>2.01<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><tr><td>5.50<\/td><td>0.4<\/td><td>100<\/td><td>0<\/td><\/tr><\/tbody><\/table><\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>HPLC<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30494<\/li><li>916750212<\/li><li>9167552<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Acrylamide<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_fs0534.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">A Better Solution for Acrylamide Analysis in Food<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">While the PGC columns used in EN 16618:2015 do sufficiently retain acrylamide, their strong retention of coextracted matrix components requires long equilibration times and shortens column lifetime. Faster overall acrylamide analysis can be achieved using Allure Acrylamide columns because they ensure sufficient retention of acrylamide, while allowing matrix compounds to be flushed out more efficiently and effectively. As a result, method system suitability requirements can be maintained over more injections, allowing more samples to be analyzed before maintenance is needed. Pairing Allure analytical columns and guard cartridges with a deuterated internal standard allows labs to increase productivity and profitability by analyzing more samples, in less time, with fewer columns.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>J.A.G. Roach, D. Andrzejewski, M.L. Gay, D. Nortrup, S.M. Musser, Rugged LC-MS\/MS survey analysis for acrylamide in foods, J. Agric. Food Chem. 51 (2003) 7547\u22127554.&nbsp;<a href=\"https:\/\/pubs.acs.org\/doi\/abs\/10.1021\/jf0346354\" target=\"_blank\" rel=\"noopener\">https:\/\/pubs.acs.org\/doi\/abs\/10.1021\/jf0346354<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This method for acrylamide analysis in food provides faster analysis times and meets EN 16618.2015 system suitability requirements longer compared to porous graphitized carbon column methods.<\/p>\n","protected":false},"author":11,"featured_media":70531,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[787],"tags":[],"industries-application":[2167,2169],"post-badge":[],"resource-type":[],"product-library":[2391,2373,2399,2374],"resource-technique":[2299,2302,2304],"ppma_author":[414],"class_list":["post-43546","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-artikel","industries-application-food-beverage","industries-application-food-safety","product-library-lc-columns","product-library-liquid-chromatography-products","product-library-liquid-reference-standards","product-library-reference-standard-products","resource-technique-liquid-chromatography","resource-technique-ms-ms","resource-technique-solid-phase-extraction-spe"],"acf":[],"taxonomy_info":{"category":[{"value":787,"label":"Artikel"}],"industries-application":[{"value":2167,"label":"Food &amp; Beverage"},{"value":2169,"label":"Food Safety"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"},{"value":2399,"label":"Liquid Reference Standards"},{"value":2374,"label":"Reference Standard Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"},{"value":2304,"label":"Solid-Phase Extraction (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAR3126-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":787,"name":"Artikel","slug":"artikel","term_group":0,"term_taxonomy_id":787,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":787,"category_count":510,"category_description":"","cat_name":"Artikel","category_nicename":"artikel","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43546"}],"version-history":[{"count":10,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43546\/revisions"}],"predecessor-version":[{"id":85566,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43546\/revisions\/85566"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/70531"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43546"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43546"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43546"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43546"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43546"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43546"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}