{"id":43609,"date":"2021-03-22T00:00:00","date_gmt":"2021-03-22T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/speed-up-multiresidue-pesticides-analysis-in-food-with-low-pressure-gc-ms\/"},"modified":"2026-10-01T20:16:28","modified_gmt":"2026-10-01T20:16:28","slug":"speed-up-multiresidue-pesticides-analysis-in-food-with-low-pressure-gc-ms","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articles-zh\/fsfa3504\/speed-up-multiresidue-pesticides-analysis-in-food-with-low-pressure-gc-ms","title":{"rendered":"Speed Up Multiresidue Pesticides Analysis in Food with an LPGC Rtx-5ms Column Kit for Low-Pressure GC-MS"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Up to 3.3x faster with up to 76% less helium consumption compared to conventional methods.<\/li>\n\n\n\n<li>Get the speed advantage of LPGC-MS with a simple column change.<\/li>\n\n\n\n<li>Robust, factory-coupled column kit ensures leak-free performance.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Multiresidue pesticides analysis is a cornerstone of food safety testing, and labs are generally under pressure to manage both a high volume of samples and rapid turnaround time requirements. This creates demand for faster GC-MS and GC-MS\/MS methods, but typical approaches involve expensive instrumentation or \u201cfast GC\u201d techniques that have capacity issues (narrow-bore columns) or MS-compatibility concerns (hydrogen carrier gas). Low-pressure GC-MS (LPGC-MS) is option that can provide significant speed gains without these drawbacks, but, historically, the challenging setup has been a barrier to implementation. This LPGC-MS pesticides analysis utilizes a unique LPGC Rtx-5ms column kit (cat.# 11800 or 11802) that is comprised of a narrow restrictor column that is factory coupled to a wider Rtx-5ms analytical column . Using either of these pre-connected kits allows the speed gains and helium savings of LPGC-MS to be obtained by making a simple column change and updating the instrument method with the new column dimensions, oven ramp, and flow rates. Either Rtx-5ms kit will perform the analysis 3x faster. Choose the kit based on your needs: cat.# 11800 has an integrated transfer line that can make background stabilization faster and can handle higher flow rates. Choose cat.# 11802 if less helium usage and lower flow rates are preferred.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As shown in the LPGC-MS pesticides analysis of 209 compounds in strawberries (Figure 1), all analytes elute quickly, with deltamethrin eluting last at 8.33 minutes. This time is three-fold faster than our analysis of the same extract on a conventional 30 m, 0.25 mm ID, 0.25 \u00b5m 5-type column where deltamethrin was again the final compound and eluted at 26.34 minutes. In addition to the speed improvement, LPGC kit (cat.# 11800) used 54% less helium than the conventional method. LPGC kit cat.# 11802 used 76% less helium while remaining 3x faster (see Figure 2).&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For busy food labs needing faster methods, the speed gains of LPGC-MS pesticides analysis are an effective way to increase sample throughput. This once-challenging setup is now much simpler to implement using a low-pressure GC column kit from Restek. Visit www.restek.com\/lpgc to learn more about this powerful technique.&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:\u00a0<\/strong>Fast Analysis of Pesticides in Strawberries on LPGC Rtx-5ms (15 m x 0.53 mm ID, cat.# 11800)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0572.png\" alt=\"200+ Pesticides in Strawberry on Low-Pressure GC Column Kit\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0572<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><th style=\"text-align: center;width: 75px\">Collision Energy<\/th><th style=\"text-align: center;width: 75px\">Confirmation Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Confirmation Product Ion<\/th><th style=\"text-align: center;width: 75px\">Collision Energy<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Allidochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/93-71-0\/Allidochlor\" target=\"_blank\" rel=\"noopener\">Allidochlor<\/a><\/td><td class=\"oth\">3.37<\/td><td class=\"oth\">138<\/td><td class=\"oth\">81<\/td><td class=\"oth\">8<\/td><td class=\"oth\">132<\/td><td class=\"oth\">56<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlobenil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1194-65-6\/Dichlobenil\" target=\"_blank\" rel=\"noopener\">Dichlobenil<\/a><\/td><td class=\"oth\">3.63<\/td><td class=\"oth\">171<\/td><td class=\"oth\">100<\/td><td class=\"oth\">25<\/td><td class=\"oth\">136<\/td><td class=\"oth\">100.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Biphenyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/92-52-4\/Biphenyl\" target=\"_blank\" rel=\"noopener\">Biphenyl<\/a><\/td><td class=\"oth\">3.75<\/td><td class=\"oth\">154.1<\/td><td class=\"oth\">115<\/td><td class=\"oth\">25<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos\" target=\"_blank\" rel=\"noopener\">Mevinphos<\/a><\/td><td class=\"oth\">3.88<\/td><td class=\"oth\">192<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">95<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 3,4-Dichloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95-76-1\/3,4-Dichloroaniline\" target=\"_blank\" rel=\"noopener\">3,4-Dichloroaniline<\/a><\/td><td class=\"oth\">3.92<\/td><td class=\"oth\">163<\/td><td class=\"oth\">90<\/td><td class=\"oth\">16<\/td><td class=\"oth\">161<\/td><td class=\"oth\">126.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pebulate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1114-71-2\/Pebulate\" target=\"_blank\" rel=\"noopener\">Pebulate<\/a><\/td><td class=\"oth\">4.01<\/td><td class=\"oth\">203<\/td><td class=\"oth\">128<\/td><td class=\"oth\">8<\/td><td class=\"oth\">128<\/td><td class=\"oth\">57<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etridiazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2593-15-9\/Etridiazole\" target=\"_blank\" rel=\"noopener\">Etridiazole<\/a><\/td><td class=\"oth\">4.02<\/td><td class=\"oth\">211<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">22<\/td><td class=\"oth\">182.8<\/td><td class=\"oth\">139.9<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>N<\/i>-(2,4-Dimethylphenyl) formamide&#8221; title=&#8221;View compound information for <i>N<\/i>-(2,4-Dimethylphenyl) formamide&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/60397-77-5\/<i>N-(2,4-Dimethylphenyl) formamide&#8221;&gt;<i>N<\/i>-(2,4-Dimethylphenyl) formamide<\/a><\/td><td class=\"oth\">4.10<\/td><td class=\"oth\">121<\/td><td class=\"oth\">106<\/td><td class=\"oth\">8<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetrahydrophthalimide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1469-48-3\/Tetrahydrophthalimide\" target=\"_blank\" rel=\"noopener\">Tetrahydrophthalimide<\/a><\/td><td class=\"oth\">4.10<\/td><td class=\"oth\">151.1<\/td><td class=\"oth\">80.1<\/td><td class=\"oth\">6<\/td><td class=\"oth\">151.1<\/td><td class=\"oth\">122<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methacrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62610-77-9\/Methacrifos\" target=\"_blank\" rel=\"noopener\">Methacrifos<\/a><\/td><td class=\"oth\">4.19<\/td><td class=\"oth\">240<\/td><td class=\"oth\">180<\/td><td class=\"oth\">10<\/td><td class=\"oth\">125<\/td><td class=\"oth\">79<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chloroneb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2675-77-6\/Chloroneb\" target=\"_blank\" rel=\"noopener\">Chloroneb<\/a><\/td><td class=\"oth\">4.24<\/td><td class=\"oth\">206<\/td><td class=\"oth\">191<\/td><td class=\"oth\">10<\/td><td class=\"oth\">191<\/td><td class=\"oth\">113<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2-Phenylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-43-7\/2-Phenylphenol\" target=\"_blank\" rel=\"noopener\">2-Phenylphenol<\/a><\/td><td class=\"oth\">4.31<\/td><td class=\"oth\">170.2<\/td><td class=\"oth\">141.2<\/td><td class=\"oth\">22<\/td><td class=\"oth\">141<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/608-93-5\/Pentachlorobenzene\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzene<\/a><\/td><td class=\"oth\">4.33<\/td><td class=\"oth\">250<\/td><td class=\"oth\">142<\/td><td class=\"oth\">30<\/td><td class=\"oth\">250<\/td><td class=\"oth\">179<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1918-16-7\/Propachlor\" target=\"_blank\" rel=\"noopener\">Propachlor<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">176<\/td><td class=\"oth\">57<\/td><td class=\"oth\">8<\/td><td class=\"oth\">120<\/td><td class=\"oth\">77<\/td><td class=\"oth\">19<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tecnazene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/117-18-0\/Tecnazene\" target=\"_blank\" rel=\"noopener\">Tecnazene<\/a><\/td><td class=\"oth\">4.60<\/td><td class=\"oth\">260.9<\/td><td class=\"oth\">202.9<\/td><td class=\"oth\">13<\/td><td class=\"oth\">214.9<\/td><td class=\"oth\">178.9<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenylamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-39-4\/Diphenylamine\" target=\"_blank\" rel=\"noopener\">Diphenylamine<\/a><\/td><td class=\"oth\">4.63<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">25<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cycloate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1134-23-2\/Cycloate\" target=\"_blank\" rel=\"noopener\">Cycloate<\/a><\/td><td class=\"oth\">4.67<\/td><td class=\"oth\">215<\/td><td class=\"oth\">154<\/td><td class=\"oth\">6<\/td><td class=\"oth\">154<\/td><td class=\"oth\">83<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,3,5,6-Tetrachloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3481-20-7\/2,3,5,6-Tetrachloroaniline\" target=\"_blank\" rel=\"noopener\">2,3,5,6-Tetrachloroaniline<\/a><\/td><td class=\"oth\">4.69<\/td><td class=\"oth\">231<\/td><td class=\"oth\">122<\/td><td class=\"oth\">30<\/td><td class=\"oth\">231<\/td><td class=\"oth\">160<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpropham\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101-21-3\/Chlorpropham\" target=\"_blank\" rel=\"noopener\">Chlorpropham<\/a><\/td><td class=\"oth\">4.70<\/td><td class=\"oth\">213.1<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">171<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethalfluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55283-68-6\/Ethalfluralin\" target=\"_blank\" rel=\"noopener\">Ethalfluralin<\/a><\/td><td class=\"oth\">4.75<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">276.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">276.1<\/td><td class=\"oth\">202.1<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Trifluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1582-09-8\/Trifluralin\" target=\"_blank\" rel=\"noopener\">Trifluralin<\/a><\/td><td class=\"oth\">4.78<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">206.2<\/td><td class=\"oth\">12<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Benfluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1861-40-1\/Benfluralin\" target=\"_blank\" rel=\"noopener\">Benfluralin<\/a><\/td><td class=\"oth\">4.80<\/td><td class=\"oth\">292<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">20<\/td><td class=\"oth\">292<\/td><td class=\"oth\">264.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulfotepp\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3689-24-5\/Sulfotepp\" target=\"_blank\" rel=\"noopener\">Sulfotepp<\/a><\/td><td class=\"oth\">4.85<\/td><td class=\"oth\">322<\/td><td class=\"oth\">146<\/td><td class=\"oth\">23<\/td><td class=\"oth\">202<\/td><td class=\"oth\">146<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diallate 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-16-4\/Diallate 1\" target=\"_blank\" rel=\"noopener\">Diallate 1<\/a><\/td><td class=\"oth\">4.89<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">150<\/td><td class=\"oth\">18<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">192.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phorate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-02-2\/Phorate\" target=\"_blank\" rel=\"noopener\">Phorate<\/a><\/td><td class=\"oth\">4.90<\/td><td class=\"oth\">260.1<\/td><td class=\"oth\">75<\/td><td class=\"oth\">8<\/td><td class=\"oth\">121.1<\/td><td class=\"oth\">65<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diallate 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-16-4\/Diallate 2\" target=\"_blank\" rel=\"noopener\">Diallate 2<\/a><\/td><td class=\"oth\">4.95<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">150<\/td><td class=\"oth\">18<\/td><td class=\"oth\">234.1<\/td><td class=\"oth\">192.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b1-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-84-6\/\u03b1-BHC\" target=\"_blank\" rel=\"noopener\">\u03b1-BHC<\/a><\/td><td class=\"oth\">5.00<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexachlorobenzene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118-74-1\/Hexachlorobenzene\" target=\"_blank\" rel=\"noopener\">Hexachlorobenzene<\/a><\/td><td class=\"oth\">5.02<\/td><td class=\"oth\">283.8<\/td><td class=\"oth\">213.9<\/td><td class=\"oth\">30<\/td><td class=\"oth\">248.9<\/td><td class=\"oth\">213.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicloran\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/99-30-9\/Dicloran\" target=\"_blank\" rel=\"noopener\">Dicloran<\/a><\/td><td class=\"oth\">5.03<\/td><td class=\"oth\">206<\/td><td class=\"oth\">147.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">176<\/td><td class=\"oth\">148<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroanisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1825-21-4\/Pentachloroanisole\" target=\"_blank\" rel=\"noopener\">Pentachloroanisole<\/a><\/td><td class=\"oth\">5.04<\/td><td class=\"oth\">279.9<\/td><td class=\"oth\">236.9<\/td><td class=\"oth\">23<\/td><td class=\"oth\">266.9<\/td><td class=\"oth\">238.9<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Atrazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1912-24-9\/Atrazine\" target=\"_blank\" rel=\"noopener\">Atrazine<\/a><\/td><td class=\"oth\">5.05<\/td><td class=\"oth\">215<\/td><td class=\"oth\">173.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">200.1<\/td><td class=\"oth\">122.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Clomazone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/81777-89-1\/Clomazone\" target=\"_blank\" rel=\"noopener\">Clomazone<\/a><\/td><td class=\"oth\">5.10<\/td><td class=\"oth\">204<\/td><td class=\"oth\">107<\/td><td class=\"oth\">18<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b2-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-85-7\/\u03b2-BHC\" target=\"_blank\" rel=\"noopener\">\u03b2-BHC<\/a><\/td><td class=\"oth\">5.12<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Profluralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26399-36-0\/Profluralin\" target=\"_blank\" rel=\"noopener\">Profluralin<\/a><\/td><td class=\"oth\">5.14<\/td><td class=\"oth\">330.1<\/td><td class=\"oth\">69<\/td><td class=\"oth\">25<\/td><td class=\"oth\">318.1<\/td><td class=\"oth\">199<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbuthylazine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5915-41-3\/Terbuthylazine\" target=\"_blank\" rel=\"noopener\">Terbuthylazine<\/a><\/td><td class=\"oth\">5.16<\/td><td class=\"oth\">229.1<\/td><td class=\"oth\">173.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">172.8<\/td><td class=\"oth\">137.9<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbufos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13071-79-9\/Terbufos\" target=\"_blank\" rel=\"noopener\">Terbufos<\/a><\/td><td class=\"oth\">5.17<\/td><td class=\"oth\">231<\/td><td class=\"oth\">129<\/td><td class=\"oth\">23<\/td><td class=\"oth\">231<\/td><td class=\"oth\">175<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b3-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-89-9\/\u03b3-BHC\" target=\"_blank\" rel=\"noopener\">\u03b3-BHC<\/a><\/td><td class=\"oth\">5.16<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propyzamide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23950-58-5\/Propyzamide\" target=\"_blank\" rel=\"noopener\">Propyzamide<\/a><\/td><td class=\"oth\">5.18<\/td><td class=\"oth\">173<\/td><td class=\"oth\">109<\/td><td class=\"oth\">27<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazinon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/333-41-5\/Diazinon\" target=\"_blank\" rel=\"noopener\">Diazinon<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">304<\/td><td class=\"oth\">179.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">84.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fonofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/944-22-9\/Fonofos\" target=\"_blank\" rel=\"noopener\">Fonofos<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">246.1<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">109<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">41.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quintozene\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82-68-8\/Quintozene\" target=\"_blank\" rel=\"noopener\">Quintozene<\/a><\/td><td class=\"oth\">5.19<\/td><td class=\"oth\">294.8<\/td><td class=\"oth\">237<\/td><td class=\"oth\">15<\/td><td class=\"oth\">236.8<\/td><td class=\"oth\">119<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">42.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluchloralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33245-39-5\/Fluchloralin\" target=\"_blank\" rel=\"noopener\">Fluchloralin<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">159.7<\/td><td class=\"oth\">20<\/td><td class=\"oth\">306.1<\/td><td class=\"oth\">264<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">43.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorobenzonitrile\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/20925-85-3\/Pentachlorobenzonitrile\" target=\"_blank\" rel=\"noopener\">Pentachlorobenzonitrile<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">275<\/td><td class=\"oth\">205<\/td><td class=\"oth\">30<\/td><td class=\"oth\">273<\/td><td class=\"oth\">238<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">44.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrimethanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53112-28-0\/Pyrimethanil\" target=\"_blank\" rel=\"noopener\">Pyrimethanil<\/a><\/td><td class=\"oth\">5.21<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">32<\/td><td class=\"oth\">198.1<\/td><td class=\"oth\">183<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">45.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tefluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79538-32-2\/Tefluthrin\" target=\"_blank\" rel=\"noopener\">Tefluthrin<\/a><\/td><td class=\"oth\">5.24<\/td><td class=\"oth\">177<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">15<\/td><td class=\"oth\">177<\/td><td class=\"oth\">137.1<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">46.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Disulfoton\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-04-4\/Disulfoton\" target=\"_blank\" rel=\"noopener\">Disulfoton<\/a><\/td><td class=\"oth\">5.25<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">97<\/td><td class=\"oth\">12<\/td><td class=\"oth\">88.1<\/td><td class=\"oth\">59.9<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">47.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Terbacil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5902-51-2\/Terbacil\" target=\"_blank\" rel=\"noopener\">Terbacil<\/a><\/td><td class=\"oth\">5.26<\/td><td class=\"oth\">161<\/td><td class=\"oth\">144<\/td><td class=\"oth\">14<\/td><td class=\"oth\">160<\/td><td class=\"oth\">117<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">48.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42509-80-8\/Isazophos\" target=\"_blank\" rel=\"noopener\">Isazophos<\/a><\/td><td class=\"oth\">5.29<\/td><td class=\"oth\">172.1<\/td><td class=\"oth\">130<\/td><td class=\"oth\">10<\/td><td class=\"oth\">161.1<\/td><td class=\"oth\">119<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">49.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03b4-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/319-86-8\/\u03b4-BHC\" target=\"_blank\" rel=\"noopener\">\u03b4-BHC<\/a><\/td><td class=\"oth\">5.31<\/td><td class=\"oth\">219<\/td><td class=\"oth\">183<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">145<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">50.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triallate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2303-17-5\/Triallate\" target=\"_blank\" rel=\"noopener\">Triallate<\/a><\/td><td class=\"oth\">5.32<\/td><td class=\"oth\">270<\/td><td class=\"oth\">186<\/td><td class=\"oth\">18<\/td><td class=\"oth\">268<\/td><td class=\"oth\">184<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">51.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorothalonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1897-45-6\/Chlorothalonil\" target=\"_blank\" rel=\"noopener\">Chlorothalonil<\/a><\/td><td class=\"oth\">5.34<\/td><td class=\"oth\">266<\/td><td class=\"oth\">170<\/td><td class=\"oth\">23<\/td><td class=\"oth\">264<\/td><td class=\"oth\">168<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">52.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthracene (IS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120-12-7\/Anthracene\" target=\"_blank\" rel=\"noopener\">Anthracene (IS)<\/a><\/td><td class=\"oth\">5.35<\/td><td class=\"oth\">178<\/td><td class=\"oth\">152<\/td><td class=\"oth\">20<\/td><td class=\"oth\"><\/td><td class=\"oth\"><\/td><td class=\"oth\"><\/td><\/tr>\n<tr><td class=\"num\">53.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan ether\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3369-52-6\/Endosulfan ether\" target=\"_blank\" rel=\"noopener\">Endosulfan ether<\/a><\/td><td class=\"oth\">5.42<\/td><td class=\"oth\">240.9<\/td><td class=\"oth\">206<\/td><td class=\"oth\">13<\/td><td class=\"oth\">238.9<\/td><td class=\"oth\">204<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">54.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/709-98-8\/Propanil\" target=\"_blank\" rel=\"noopener\">Propanil<\/a><\/td><td class=\"oth\">5.44<\/td><td class=\"oth\">219<\/td><td class=\"oth\">163<\/td><td class=\"oth\">8<\/td><td class=\"oth\">217<\/td><td class=\"oth\">161<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">55.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachloroaniline\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/527-20-8\/Pentachloroaniline\" target=\"_blank\" rel=\"noopener\">Pentachloroaniline<\/a><\/td><td class=\"oth\">5.45<\/td><td class=\"oth\">265<\/td><td class=\"oth\">194<\/td><td class=\"oth\">22<\/td><td class=\"oth\">263<\/td><td class=\"oth\">192<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">56.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50563-36-5\/Dimethachlor\" target=\"_blank\" rel=\"noopener\">Dimethachlor<\/a><\/td><td class=\"oth\">5.46<\/td><td class=\"oth\">197<\/td><td class=\"oth\">148<\/td><td class=\"oth\">8<\/td><td class=\"oth\">134<\/td><td class=\"oth\">105<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">57.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acetochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34256-82-1\/Acetochlor\" target=\"_blank\" rel=\"noopener\">Acetochlor<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">223<\/td><td class=\"oth\">132<\/td><td class=\"oth\">20<\/td><td class=\"oth\">174<\/td><td class=\"oth\">146<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">58.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Transfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/118712-89-3\/Transfluthrin\" target=\"_blank\" rel=\"noopener\">Transfluthrin<\/a><\/td><td class=\"oth\">5.48<\/td><td class=\"oth\">163<\/td><td class=\"oth\">143<\/td><td class=\"oth\">13<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">91.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">59.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vinclozolin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50471-44-8\/Vinclozolin\" target=\"_blank\" rel=\"noopener\">Vinclozolin<\/a><\/td><td class=\"oth\">5.50<\/td><td class=\"oth\">285<\/td><td class=\"oth\">212<\/td><td class=\"oth\">12<\/td><td class=\"oth\">212<\/td><td class=\"oth\">172<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">60.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5598-13-0\/Chlorpyrifos methyl\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos methyl<\/a><\/td><td class=\"oth\">5.52<\/td><td class=\"oth\">286<\/td><td class=\"oth\">93<\/td><td class=\"oth\">22<\/td><td class=\"oth\">286<\/td><td class=\"oth\">207.9<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">61.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methyl parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/298-00-0\/Methyl parathion\" target=\"_blank\" rel=\"noopener\">Methyl parathion<\/a><\/td><td class=\"oth\">5.52<\/td><td class=\"oth\">263<\/td><td class=\"oth\">109<\/td><td class=\"oth\">10<\/td><td class=\"oth\">263<\/td><td class=\"oth\">136.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">62.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolclofos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57018-04-9\/Tolclofos-methyl\" target=\"_blank\" rel=\"noopener\">Tolclofos-methyl<\/a><\/td><td class=\"oth\">5.54<\/td><td class=\"oth\">267<\/td><td class=\"oth\">252<\/td><td class=\"oth\">10<\/td><td class=\"oth\">265<\/td><td class=\"oth\">250<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">63.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Alachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/15972-60-8\/Alachlor\" target=\"_blank\" rel=\"noopener\">Alachlor<\/a><\/td><td class=\"oth\">5.55<\/td><td class=\"oth\">188<\/td><td class=\"oth\">160<\/td><td class=\"oth\">10<\/td><td class=\"oth\">146<\/td><td class=\"oth\">118<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">64.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metalaxyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57837-19-1\/Metalaxyl\" target=\"_blank\" rel=\"noopener\">Metalaxyl<\/a><\/td><td class=\"oth\">5.56<\/td><td class=\"oth\">220.1<\/td><td class=\"oth\">160.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">160.1<\/td><td class=\"oth\">145.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">65.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propisochlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86763-47-5\/Propisochlor\" target=\"_blank\" rel=\"noopener\">Propisochlor<\/a><\/td><td class=\"oth\">5.56<\/td><td class=\"oth\">223<\/td><td class=\"oth\">132<\/td><td class=\"oth\">18<\/td><td class=\"oth\">162<\/td><td class=\"oth\">120<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">66.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenchlorphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/299-84-3\/Fenchlorphos\" target=\"_blank\" rel=\"noopener\">Fenchlorphos<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">287<\/td><td class=\"oth\">272<\/td><td class=\"oth\">11<\/td><td class=\"oth\">285<\/td><td class=\"oth\">240<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">67.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heptachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76-44-8\/Heptachlor\" target=\"_blank\" rel=\"noopener\">Heptachlor<\/a><\/td><td class=\"oth\">5.59<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">13<\/td><td class=\"oth\">100<\/td><td class=\"oth\">65<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">68.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prodiamine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29091-21-2\/Prodiamine\" target=\"_blank\" rel=\"noopener\">Prodiamine<\/a><\/td><td class=\"oth\">5.63<\/td><td class=\"oth\">321<\/td><td class=\"oth\">279<\/td><td class=\"oth\">6<\/td><td class=\"oth\">279<\/td><td class=\"oth\">203<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">69.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pirimiphos methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29232-93-7\/Pirimiphos methyl\" target=\"_blank\" rel=\"noopener\">Pirimiphos methyl<\/a><\/td><td class=\"oth\">5.65<\/td><td class=\"oth\">305.1<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">290.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">70.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenitrothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122-14-5\/Fenitrothion\" target=\"_blank\" rel=\"noopener\">Fenitrothion<\/a><\/td><td class=\"oth\">5.66<\/td><td class=\"oth\">277<\/td><td class=\"oth\">109<\/td><td class=\"oth\">16<\/td><td class=\"oth\">260<\/td><td class=\"oth\">125<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">71.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Linuron\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/330-55-2\/Linuron\" target=\"_blank\" rel=\"noopener\">Linuron<\/a><\/td><td class=\"oth\">5.69<\/td><td class=\"oth\">248<\/td><td class=\"oth\">61<\/td><td class=\"oth\">8<\/td><td class=\"oth\">187<\/td><td class=\"oth\">124<\/td><td class=\"oth\">21<\/td><\/tr>\n<tr><td class=\"num\">72.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Malathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-75-5\/Malathion\" target=\"_blank\" rel=\"noopener\">Malathion<\/a><\/td><td class=\"oth\">5.69<\/td><td class=\"oth\">173<\/td><td class=\"oth\">99<\/td><td class=\"oth\">13<\/td><td class=\"oth\">127<\/td><td class=\"oth\">99<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">73.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlofluanid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1085-98-9\/Dichlofluanid\" target=\"_blank\" rel=\"noopener\">Dichlofluanid<\/a><\/td><td class=\"oth\">5.72<\/td><td class=\"oth\">224<\/td><td class=\"oth\">123<\/td><td class=\"oth\">12<\/td><td class=\"oth\">123<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">74.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pentachlorothioanisole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1825-19-0\/Pentachlorothioanisole\" target=\"_blank\" rel=\"noopener\">Pentachlorothioanisole<\/a><\/td><td class=\"oth\">5.73<\/td><td class=\"oth\">296<\/td><td class=\"oth\">246<\/td><td class=\"oth\">32<\/td><td class=\"oth\">296<\/td><td class=\"oth\">263<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">75.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metolachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51218-45-2\/Metolachlor\" target=\"_blank\" rel=\"noopener\">Metolachlor<\/a><\/td><td class=\"oth\">5.76<\/td><td class=\"oth\">238<\/td><td class=\"oth\">162<\/td><td class=\"oth\">10<\/td><td class=\"oth\">162<\/td><td class=\"oth\">133<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">76.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2921-88-2\/Chlorpyrifos\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">314<\/td><td class=\"oth\">257.9<\/td><td class=\"oth\">12<\/td><td class=\"oth\">196.9<\/td><td class=\"oth\">168.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">77.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenthion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-38-9\/Fenthion\" target=\"_blank\" rel=\"noopener\">Fenthion<\/a><\/td><td class=\"oth\">5.77<\/td><td class=\"oth\">278<\/td><td class=\"oth\">109<\/td><td class=\"oth\">18<\/td><td class=\"oth\">278<\/td><td class=\"oth\">169<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">78.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Parathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-38-2\/Parathion\" target=\"_blank\" rel=\"noopener\">Parathion<\/a><\/td><td class=\"oth\">5.78<\/td><td class=\"oth\">291.2<\/td><td class=\"oth\">109.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">109<\/td><td class=\"oth\">81<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">79.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Anthraquinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84-65-1\/Anthraquinone\" target=\"_blank\" rel=\"noopener\">Anthraquinone<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">180.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">80.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triadimefon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/43121-43-3\/Triadimefon\" target=\"_blank\" rel=\"noopener\">Triadimefon<\/a><\/td><td class=\"oth\">5.79<\/td><td class=\"oth\">208<\/td><td class=\"oth\">110.9<\/td><td class=\"oth\">24<\/td><td class=\"oth\">208<\/td><td class=\"oth\">180.8<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">81.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Aldrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/309-00-2\/Aldrin\" target=\"_blank\" rel=\"noopener\">Aldrin<\/a><\/td><td class=\"oth\">5.80<\/td><td class=\"oth\">298<\/td><td class=\"oth\">263<\/td><td class=\"oth\">8<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">31<\/td><\/tr>\n<tr><td class=\"num\">82.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthal-dimethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1861-32-1\/Chlorthal-dimethyl\" target=\"_blank\" rel=\"noopener\">Chlorthal-dimethyl<\/a><\/td><td class=\"oth\">5.81<\/td><td class=\"oth\">331.8<\/td><td class=\"oth\">301<\/td><td class=\"oth\">8<\/td><td class=\"oth\">298.9<\/td><td class=\"oth\">220.9<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">83.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Dichlorobenzophenone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-98-2\/4,4&amp;apos;-Dichlorobenzophenone\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Dichlorobenzophenone<\/a><\/td><td class=\"oth\">5.81<\/td><td class=\"oth\">139<\/td><td class=\"oth\">75<\/td><td class=\"oth\">27<\/td><td class=\"oth\">111<\/td><td class=\"oth\">75.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">84.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pirimiphos ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/23505-41-1\/Pirimiphos ethyl\" target=\"_blank\" rel=\"noopener\">Pirimiphos ethyl<\/a><\/td><td class=\"oth\">5.85<\/td><td class=\"oth\">318.2<\/td><td class=\"oth\">166.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">304.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">85.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenson\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-38-6\/Fenson\" target=\"_blank\" rel=\"noopener\">Fenson<\/a><\/td><td class=\"oth\">5.86<\/td><td class=\"oth\">268<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">18<\/td><td class=\"oth\">141<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">86.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyprodinil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121552-61-2\/Cyprodinil\" target=\"_blank\" rel=\"noopener\">Cyprodinil<\/a><\/td><td class=\"oth\">5.87<\/td><td class=\"oth\">225.2<\/td><td class=\"oth\">209.8<\/td><td class=\"oth\">12<\/td><td class=\"oth\">224.1<\/td><td class=\"oth\">208.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">87.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diphenamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/957-51-7\/Diphenamid\" target=\"_blank\" rel=\"noopener\">Diphenamid<\/a><\/td><td class=\"oth\">5.88<\/td><td class=\"oth\">239<\/td><td class=\"oth\">167<\/td><td class=\"oth\">8<\/td><td class=\"oth\">167<\/td><td class=\"oth\">115<\/td><td class=\"oth\">40<\/td><\/tr>\n<tr><td class=\"num\">88.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isopropalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33820-53-0\/Isopropalin\" target=\"_blank\" rel=\"noopener\">Isopropalin<\/a><\/td><td class=\"oth\">5.89<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">25<\/td><td class=\"oth\">280.1<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">89.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MGK 264 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-48-4\/MGK 264 1\" target=\"_blank\" rel=\"noopener\">MGK 264 1<\/a><\/td><td class=\"oth\">5.89<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">80<\/td><td class=\"oth\">24<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">90.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromophos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2104-96-3\/Bromophos-methyl\" target=\"_blank\" rel=\"noopener\">Bromophos-methyl<\/a><\/td><td class=\"oth\">5.90<\/td><td class=\"oth\">331<\/td><td class=\"oth\">316<\/td><td class=\"oth\">13<\/td><td class=\"oth\">329<\/td><td class=\"oth\">314<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">91.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlozolinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/84332-86-5\/Chlozolinate\" target=\"_blank\" rel=\"noopener\">Chlozolinate<\/a><\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">331<\/td><td class=\"oth\">259.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">186<\/td><td class=\"oth\">145<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">92.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pendimethalin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/40487-42-1\/Pendimethalin\" target=\"_blank\" rel=\"noopener\">Pendimethalin<\/a><\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">281.1<\/td><td class=\"oth\">252.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">162.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">93.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bioallethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/584-79-2\/Bioallethrin\" target=\"_blank\" rel=\"noopener\">Bioallethrin<\/a><\/td><td class=\"oth\">5.96<\/td><td class=\"oth\">136.1<\/td><td class=\"oth\">93<\/td><td class=\"oth\">11<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">94.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fipronil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/120068-37-3\/Fipronil\" target=\"_blank\" rel=\"noopener\">Fipronil<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">367<\/td><td class=\"oth\">213<\/td><td class=\"oth\">30<\/td><td class=\"oth\">369<\/td><td class=\"oth\">215<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">95.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for MGK 264 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/113-48-4\/MGK 264 2\" target=\"_blank\" rel=\"noopener\">MGK 264 2<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">164<\/td><td class=\"oth\">67<\/td><td class=\"oth\">10<\/td><td class=\"oth\">164.1<\/td><td class=\"oth\">80<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">96.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Isodrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/465-73-6\/Isodrin\" target=\"_blank\" rel=\"noopener\">Isodrin<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">260.9<\/td><td class=\"oth\">190.9<\/td><td class=\"oth\">28<\/td><td class=\"oth\">193<\/td><td class=\"oth\">123<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">97.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metazachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67129-08-2\/Metazachlor\" target=\"_blank\" rel=\"noopener\">Metazachlor<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">209<\/td><td class=\"oth\">132<\/td><td class=\"oth\">15<\/td><td class=\"oth\">133<\/td><td class=\"oth\">117<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">98.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Penconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66246-88-6\/Penconazole\" target=\"_blank\" rel=\"noopener\">Penconazole<\/a><\/td><td class=\"oth\">5.97<\/td><td class=\"oth\">248.1<\/td><td class=\"oth\">192<\/td><td class=\"oth\">16<\/td><td class=\"oth\">159<\/td><td class=\"oth\">89<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">99.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenvinphos 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-90-6\/Chlorfenvinphos 1\" target=\"_blank\" rel=\"noopener\">Chlorfenvinphos 1<\/a><\/td><td class=\"oth\">6.04<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><td class=\"oth\">267<\/td><td class=\"oth\">159<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">100.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tolylfluanid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/731-27-1\/Tolylfluanid\" target=\"_blank\" rel=\"noopener\">Tolylfluanid<\/a><\/td><td class=\"oth\">6.05<\/td><td class=\"oth\">240<\/td><td class=\"oth\">137<\/td><td class=\"oth\">10<\/td><td class=\"oth\">238<\/td><td class=\"oth\">137<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">101.<\/td><td class=\"cmpd\">Bromfenvinphos-methyl<\/td><td class=\"oth\">6.06<\/td><td class=\"oth\">295<\/td><td class=\"oth\">109<\/td><td class=\"oth\">15<\/td><td class=\"oth\">109<\/td><td class=\"oth\">79<\/td><td class=\"oth\">5<\/td><\/tr>\n<tr><td class=\"num\">102.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Heptachlor epoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1024-57-3\/Heptachlor epoxide\" target=\"_blank\" rel=\"noopener\">Heptachlor epoxide<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">353<\/td><td class=\"oth\">263<\/td><td class=\"oth\">13<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">29<\/td><\/tr>\n<tr><td class=\"num\">103.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Quinalphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13593-03-8\/Quinalphos\" target=\"_blank\" rel=\"noopener\">Quinalphos<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">298<\/td><td class=\"oth\">156.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">146.1<\/td><td class=\"oth\">118.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">104.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triadimenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55219-65-3\/Triadimenol\" target=\"_blank\" rel=\"noopener\">Triadimenol<\/a><\/td><td class=\"oth\">6.07<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">70.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">128<\/td><td class=\"oth\">65.1<\/td><td class=\"oth\">22<\/td><\/tr>\n<tr><td class=\"num\">105.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triflumizole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68694-11-1\/Triflumizole\" target=\"_blank\" rel=\"noopener\">Triflumizole<\/a><\/td><td class=\"oth\">6.09<\/td><td class=\"oth\">205.9<\/td><td class=\"oth\">179<\/td><td class=\"oth\">14<\/td><td class=\"oth\">179<\/td><td class=\"oth\">143.8<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">106.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">6.10<\/td><td class=\"oth\">149<\/td><td class=\"oth\">105<\/td><td class=\"oth\">6<\/td><td class=\"oth\">106.8<\/td><td class=\"oth\">79<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">107.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Procymidone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/32809-16-8\/Procymidone\" target=\"_blank\" rel=\"noopener\">Procymidone<\/a><\/td><td class=\"oth\">6.11<\/td><td class=\"oth\">283<\/td><td class=\"oth\">67.1<\/td><td class=\"oth\">28<\/td><td class=\"oth\">283<\/td><td class=\"oth\">96<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">108.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Folpet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-07-3\/Folpet\" target=\"_blank\" rel=\"noopener\">Folpet<\/a><\/td><td class=\"oth\">6.14<\/td><td class=\"oth\">259.9<\/td><td class=\"oth\">130<\/td><td class=\"oth\">16<\/td><td class=\"oth\">103.9<\/td><td class=\"oth\">76<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">109.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorbenside\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/103-17-3\/Chlorbenside\" target=\"_blank\" rel=\"noopener\">Chlorbenside<\/a><\/td><td class=\"oth\">6.15<\/td><td class=\"oth\">268<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89.1<\/td><td class=\"oth\">17<\/td><\/tr>\n<tr><td class=\"num\">110.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromophos-ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4824-78-6\/Bromophos-ethyl\" target=\"_blank\" rel=\"noopener\">Bromophos-ethyl<\/a><\/td><td class=\"oth\">6.17<\/td><td class=\"oth\">358.9<\/td><td class=\"oth\">303<\/td><td class=\"oth\">17<\/td><td class=\"oth\">330.9<\/td><td class=\"oth\">303<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">111.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-74-2\/trans-Chlordane\" target=\"_blank\" rel=\"noopener\">trans-Chlordane<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">375<\/td><td class=\"oth\">266<\/td><td class=\"oth\">18<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">112.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Paclobutrazol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76738-62-0\/Paclobutrazol\" target=\"_blank\" rel=\"noopener\">Paclobutrazol<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">237.8<\/td><td class=\"oth\">127<\/td><td class=\"oth\">10<\/td><td class=\"oth\">236.1<\/td><td class=\"oth\">125.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">113.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDE\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/3424-82-6\/2,4&amp;apos;-DDE\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDE<\/a><\/td><td class=\"oth\">6.19<\/td><td class=\"oth\">316<\/td><td class=\"oth\">246<\/td><td class=\"oth\">15<\/td><td class=\"oth\">246<\/td><td class=\"oth\">176<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">114.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetrachlorvinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22248-79-9\/Tetrachlorvinphos\" target=\"_blank\" rel=\"noopener\">Tetrachlorvinphos<\/a><\/td><td class=\"oth\">6.20<\/td><td class=\"oth\">333<\/td><td class=\"oth\">109<\/td><td class=\"oth\">17<\/td><td class=\"oth\">331<\/td><td class=\"oth\">109<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">115.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenamiphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/22224-92-6\/Fenamiphos\" target=\"_blank\" rel=\"noopener\">Fenamiphos<\/a><\/td><td class=\"oth\">6.25<\/td><td class=\"oth\">303.1<\/td><td class=\"oth\">195.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">217<\/td><td class=\"oth\">202<\/td><td class=\"oth\">9<\/td><\/tr>\n<tr><td class=\"num\">116.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flutolanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/66332-96-5\/Flutolanil\" target=\"_blank\" rel=\"noopener\">Flutolanil<\/a><\/td><td class=\"oth\">6.26<\/td><td class=\"oth\">281<\/td><td class=\"oth\">173<\/td><td class=\"oth\">10<\/td><td class=\"oth\">173<\/td><td class=\"oth\">145<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">117.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prothiofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34643-46-4\/Prothiofos\" target=\"_blank\" rel=\"noopener\">Prothiofos<\/a><\/td><td class=\"oth\">6.26<\/td><td class=\"oth\">309<\/td><td class=\"oth\">239<\/td><td class=\"oth\">15<\/td><td class=\"oth\">267<\/td><td class=\"oth\">221<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">118.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Chlordane\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-71-9\/cis-Chlordane\" target=\"_blank\" rel=\"noopener\">cis-Chlordane<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">375<\/td><td class=\"oth\">266<\/td><td class=\"oth\">18<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">119.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromfenvinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/33399-00-7\/Bromfenvinphos\" target=\"_blank\" rel=\"noopener\">Bromfenvinphos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">325<\/td><td class=\"oth\">269<\/td><td class=\"oth\">10<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">120.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fludioxonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/131341-86-1\/Fludioxonil\" target=\"_blank\" rel=\"noopener\">Fludioxonil<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">248<\/td><td class=\"oth\">127<\/td><td class=\"oth\">30<\/td><td class=\"oth\">153.8<\/td><td class=\"oth\">127<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">121.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flutriafol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/76674-21-0\/Flutriafol\" target=\"_blank\" rel=\"noopener\">Flutriafol<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">219.1<\/td><td class=\"oth\">123<\/td><td class=\"oth\">14<\/td><td class=\"oth\">123.1<\/td><td class=\"oth\">95<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">122.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Iodofenphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18181-70-9\/Iodofenphos\" target=\"_blank\" rel=\"noopener\">Iodofenphos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">377<\/td><td class=\"oth\">332<\/td><td class=\"oth\">30<\/td><td class=\"oth\">377<\/td><td class=\"oth\">362<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">123.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pretilachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51218-49-6\/Pretilachlor\" target=\"_blank\" rel=\"noopener\">Pretilachlor<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">262<\/td><td class=\"oth\">202<\/td><td class=\"oth\">8<\/td><td class=\"oth\">162<\/td><td class=\"oth\">132<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">124.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Profenofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41198-08-7\/Profenofos\" target=\"_blank\" rel=\"noopener\">Profenofos<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">339<\/td><td class=\"oth\">188<\/td><td class=\"oth\">30<\/td><td class=\"oth\">337<\/td><td class=\"oth\">267<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">125.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenvinphos 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/470-90-6\/Chlorfenvinphos 2\" target=\"_blank\" rel=\"noopener\">Chlorfenvinphos 2<\/a><\/td><td class=\"oth\">6.27<\/td><td class=\"oth\">323<\/td><td class=\"oth\">267<\/td><td class=\"oth\">10<\/td><td class=\"oth\">267<\/td><td class=\"oth\">159<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">126.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan I\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/959-98-8\/Endosulfan I\" target=\"_blank\" rel=\"noopener\">Endosulfan I<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">241<\/td><td class=\"oth\">206<\/td><td class=\"oth\">10<\/td><td class=\"oth\">195<\/td><td class=\"oth\">159<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">127.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Nonachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39765-80-5\/trans-Nonachlor\" target=\"_blank\" rel=\"noopener\">trans-Nonachlor<\/a><\/td><td class=\"oth\">6.28<\/td><td class=\"oth\">409<\/td><td class=\"oth\">263<\/td><td class=\"oth\">25<\/td><td class=\"oth\">409<\/td><td class=\"oth\">300<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">128.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenson\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80-33-1\/Chlorfenson\" target=\"_blank\" rel=\"noopener\">Chlorfenson<\/a><\/td><td class=\"oth\">6.29<\/td><td class=\"oth\">302<\/td><td class=\"oth\">175<\/td><td class=\"oth\">8<\/td><td class=\"oth\">175<\/td><td class=\"oth\">111<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">129.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxadiazon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/19666-30-9\/Oxadiazon\" target=\"_blank\" rel=\"noopener\">Oxadiazon<\/a><\/td><td class=\"oth\">6.33<\/td><td class=\"oth\">258<\/td><td class=\"oth\">175<\/td><td class=\"oth\">8<\/td><td class=\"oth\">175<\/td><td class=\"oth\">112<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">130.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Oxyfluorfen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/42874-03-3\/Oxyfluorfen\" target=\"_blank\" rel=\"noopener\">Oxyfluorfen<\/a><\/td><td class=\"oth\">6.34<\/td><td class=\"oth\">300<\/td><td class=\"oth\">223<\/td><td class=\"oth\">15<\/td><td class=\"oth\">252.1<\/td><td class=\"oth\">146.1<\/td><td class=\"oth\">33<\/td><\/tr>\n<tr><td class=\"num\">131.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myclobutanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88671-89-0\/Myclobutanil\" target=\"_blank\" rel=\"noopener\">Myclobutanil<\/a><\/td><td class=\"oth\">6.38<\/td><td class=\"oth\">179<\/td><td class=\"oth\">125<\/td><td class=\"oth\">14<\/td><td class=\"oth\">179<\/td><td class=\"oth\">152<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">132.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bupirimate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41483-43-6\/Bupirimate\" target=\"_blank\" rel=\"noopener\">Bupirimate<\/a><\/td><td class=\"oth\">6.39<\/td><td class=\"oth\">316.2<\/td><td class=\"oth\">208.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">273.1<\/td><td class=\"oth\">193.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">133.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flusilazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/85509-19-9\/Flusilazole\" target=\"_blank\" rel=\"noopener\">Flusilazole<\/a><\/td><td class=\"oth\">6.39<\/td><td class=\"oth\">233.1<\/td><td class=\"oth\">164.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">206.1<\/td><td class=\"oth\">137<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">134.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDE\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-55-9\/4,4&amp;apos;-DDE\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDE<\/a><\/td><td class=\"oth\">6.40<\/td><td class=\"oth\">316<\/td><td class=\"oth\">246<\/td><td class=\"oth\">15<\/td><td class=\"oth\">246<\/td><td class=\"oth\">176<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">135.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tricyclazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/41814-78-2\/Tricyclazole\" target=\"_blank\" rel=\"noopener\">Tricyclazole<\/a><\/td><td class=\"oth\">6.41<\/td><td class=\"oth\">189<\/td><td class=\"oth\">135.2<\/td><td class=\"oth\">18<\/td><td class=\"oth\">189<\/td><td class=\"oth\">162<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">136.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53-19-0\/2,4&amp;apos;-DDD\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDD<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">137.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dieldrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-57-1\/Dieldrin\" target=\"_blank\" rel=\"noopener\">Dieldrin<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">277<\/td><td class=\"oth\">241<\/td><td class=\"oth\">8<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">34<\/td><\/tr>\n<tr><td class=\"num\">138.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluazifop-P-butyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/79241-46-6\/Fluazifop-P-butyl\" target=\"_blank\" rel=\"noopener\">Fluazifop-P-butyl<\/a><\/td><td class=\"oth\">6.42<\/td><td class=\"oth\">383.1<\/td><td class=\"oth\">268.2<\/td><td class=\"oth\">8<\/td><td class=\"oth\">383.1<\/td><td class=\"oth\">282.2<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">139.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorfenapyr\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/122453-73-0\/Chlorfenapyr\" target=\"_blank\" rel=\"noopener\">Chlorfenapyr<\/a><\/td><td class=\"oth\">6.46<\/td><td class=\"oth\">247<\/td><td class=\"oth\">227.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">137<\/td><td class=\"oth\">75<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">140.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethylan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-56-0\/Ethylan\" target=\"_blank\" rel=\"noopener\">Ethylan<\/a><\/td><td class=\"oth\">6.46<\/td><td class=\"oth\">223<\/td><td class=\"oth\">167<\/td><td class=\"oth\">12<\/td><td class=\"oth\">223<\/td><td class=\"oth\">193<\/td><td class=\"oth\">28<\/td><\/tr>\n<tr><td class=\"num\">141.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitrofen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1836-75-5\/Nitrofen\" target=\"_blank\" rel=\"noopener\">Nitrofen<\/a><\/td><td class=\"oth\">6.49<\/td><td class=\"oth\">283<\/td><td class=\"oth\">202<\/td><td class=\"oth\">10<\/td><td class=\"oth\">202<\/td><td class=\"oth\">139.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">142.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthiophos 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60238-56-4\/Chlorthiophos 1\" target=\"_blank\" rel=\"noopener\">Chlorthiophos 1<\/a><\/td><td class=\"oth\">6.50<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">165<\/td><td class=\"oth\">26<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">239<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">143.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorobenzilate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/510-15-6\/Chlorobenzilate\" target=\"_blank\" rel=\"noopener\">Chlorobenzilate<\/a><\/td><td class=\"oth\">6.52<\/td><td class=\"oth\">251<\/td><td class=\"oth\">139<\/td><td class=\"oth\">14<\/td><td class=\"oth\">139<\/td><td class=\"oth\">111<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">144.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-20-8\/Endrin\" target=\"_blank\" rel=\"noopener\">Endrin<\/a><\/td><td class=\"oth\">6.55<\/td><td class=\"oth\">263<\/td><td class=\"oth\">193<\/td><td class=\"oth\">30<\/td><td class=\"oth\">245<\/td><td class=\"oth\">173<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">145.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Ethion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/563-12-2\/Ethion\" target=\"_blank\" rel=\"noopener\">Ethion<\/a><\/td><td class=\"oth\">6.58<\/td><td class=\"oth\">231<\/td><td class=\"oth\">129<\/td><td class=\"oth\">24<\/td><td class=\"oth\">153<\/td><td class=\"oth\">97<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">146.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDD\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-54-8\/4,4&amp;apos;-DDD\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDD<\/a><\/td><td class=\"oth\">6.59<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">147.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorthiophos 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60238-56-4\/Chlorthiophos 2\" target=\"_blank\" rel=\"noopener\">Chlorthiophos 2<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">325<\/td><td class=\"oth\">269<\/td><td class=\"oth\">14<\/td><td class=\"oth\">297<\/td><td class=\"oth\">269<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">148.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 2,4&amp;apos;-DDT\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/789-02-6\/2,4&amp;apos;-DDT\" target=\"_blank\" rel=\"noopener\">2,4&#8242;-DDT<\/a><\/td><td class=\"oth\">6.62<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">149.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Triazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/24017-47-8\/Triazophos\" target=\"_blank\" rel=\"noopener\">Triazophos<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">256.9<\/td><td class=\"oth\">161.7<\/td><td class=\"oth\">8<\/td><td class=\"oth\">161<\/td><td class=\"oth\">134.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">150.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Nonachlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5103-73-1\/cis-Nonachlor\" target=\"_blank\" rel=\"noopener\">cis-Nonachlor<\/a><\/td><td class=\"oth\">6.65<\/td><td class=\"oth\">409<\/td><td class=\"oth\">263<\/td><td class=\"oth\">25<\/td><td class=\"oth\">409<\/td><td class=\"oth\">300<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">151.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Sulprofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/35400-43-2\/Sulprofos\" target=\"_blank\" rel=\"noopener\">Sulprofos<\/a><\/td><td class=\"oth\">6.66<\/td><td class=\"oth\">322<\/td><td class=\"oth\">156<\/td><td class=\"oth\">8<\/td><td class=\"oth\">156<\/td><td class=\"oth\">141<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">152.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carfentrazone ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/128639-02-1\/Carfentrazone ethyl\" target=\"_blank\" rel=\"noopener\">Carfentrazone ethyl<\/a><\/td><td class=\"oth\">6.67<\/td><td class=\"oth\">340.2<\/td><td class=\"oth\">312.2<\/td><td class=\"oth\">10<\/td><td class=\"oth\">330<\/td><td class=\"oth\">310.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">153.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin aldehyde\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7421-93-4\/Endrin aldehyde\" target=\"_blank\" rel=\"noopener\">Endrin aldehyde<\/a><\/td><td class=\"oth\">6.68<\/td><td class=\"oth\">344.9<\/td><td class=\"oth\">243.1<\/td><td class=\"oth\">17<\/td><td class=\"oth\">344.9<\/td><td class=\"oth\">244.9<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">154.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-Methoxychlor olefin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2132-70-9\/4,4&amp;apos;-Methoxychlor olefin\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-Methoxychlor olefin<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">308<\/td><td class=\"oth\">223.1<\/td><td class=\"oth\">30<\/td><td class=\"oth\">238.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">35<\/td><\/tr>\n<tr><td class=\"num\">155.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbophenothion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/786-19-6\/Carbophenothion\" target=\"_blank\" rel=\"noopener\">Carbophenothion<\/a><\/td><td class=\"oth\">6.70<\/td><td class=\"oth\">342<\/td><td class=\"oth\">157<\/td><td class=\"oth\">10<\/td><td class=\"oth\">125<\/td><td class=\"oth\">97<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">156.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norflurazon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/27314-13-2\/Norflurazon\" target=\"_blank\" rel=\"noopener\">Norflurazon<\/a><\/td><td class=\"oth\">6.74<\/td><td class=\"oth\">303<\/td><td class=\"oth\">145<\/td><td class=\"oth\">17<\/td><td class=\"oth\">145<\/td><td class=\"oth\">95<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">157.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Edifenphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/17109-49-8\/Edifenphos\" target=\"_blank\" rel=\"noopener\">Edifenphos<\/a><\/td><td class=\"oth\">6.75<\/td><td class=\"oth\">310<\/td><td class=\"oth\">109<\/td><td class=\"oth\">29<\/td><td class=\"oth\">173<\/td><td class=\"oth\">109<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">158.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Lenacil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2164-08-1\/Lenacil\" target=\"_blank\" rel=\"noopener\">Lenacil<\/a><\/td><td class=\"oth\">6.76<\/td><td class=\"oth\">153<\/td><td class=\"oth\">135.7<\/td><td class=\"oth\">14<\/td><td class=\"oth\">135.8<\/td><td class=\"oth\">52.9<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">159.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDT\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-29-3\/4,4&amp;apos;-DDT\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDT<\/a><\/td><td class=\"oth\">6.61<\/td><td class=\"oth\">235<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">21<\/td><td class=\"oth\">235<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">160.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan sulfate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1031-07-8\/Endosulfan sulfate\" target=\"_blank\" rel=\"noopener\">Endosulfan sulfate<\/a><\/td><td class=\"oth\">6.81<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">10<\/td><td class=\"oth\">241<\/td><td class=\"oth\">206<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">161.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Hexazinone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51235-04-2\/Hexazinone\" target=\"_blank\" rel=\"noopener\">Hexazinone<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">171.1<\/td><td class=\"oth\">71.1<\/td><td class=\"oth\">16<\/td><td class=\"oth\">128<\/td><td class=\"oth\">83<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">162.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Piperonyl butoxide\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51-03-6\/Piperonyl butoxide\" target=\"_blank\" rel=\"noopener\">Piperonyl butoxide<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">103<\/td><td class=\"oth\">26<\/td><td class=\"oth\">176.1<\/td><td class=\"oth\">131.1<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">163.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propargite\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2312-35-8\/Propargite\" target=\"_blank\" rel=\"noopener\">Propargite<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">201.1<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">107<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">164.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Resmethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10453-86-8\/Resmethrin\" target=\"_blank\" rel=\"noopener\">Resmethrin<\/a><\/td><td class=\"oth\">6.83<\/td><td class=\"oth\">143.1<\/td><td class=\"oth\">128<\/td><td class=\"oth\">10<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.2<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">165.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebuconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/107534-96-3\/Tebuconazole\" target=\"_blank\" rel=\"noopener\">Tebuconazole<\/a><\/td><td class=\"oth\">6.85<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">125.2<\/td><td class=\"oth\">22<\/td><td class=\"oth\">125<\/td><td class=\"oth\">89<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">166.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Nitralin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4726-14-1\/Nitralin\" target=\"_blank\" rel=\"noopener\">Nitralin<\/a><\/td><td class=\"oth\">6.95<\/td><td class=\"oth\">316.1<\/td><td class=\"oth\">274<\/td><td class=\"oth\">8<\/td><td class=\"oth\">274<\/td><td class=\"oth\">216.2<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">167.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captafol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2425-06-1\/Captafol\" target=\"_blank\" rel=\"noopener\">Captafol<\/a><\/td><td class=\"oth\">6.99<\/td><td class=\"oth\">150.8<\/td><td class=\"oth\">78.9<\/td><td class=\"oth\">18<\/td><td class=\"oth\">79<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">168.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for TPP (IS)\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-86-6\/TPP\" target=\"_blank\" rel=\"noopener\">TPP (IS)<\/a><\/td><td class=\"oth\">6.99<\/td><td class=\"oth\">326<\/td><td class=\"oth\">169<\/td><td class=\"oth\">30<\/td><td class=\"oth\">326<\/td><td class=\"oth\">215<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">169.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Iprodione\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36734-19-7\/Iprodione\" target=\"_blank\" rel=\"noopener\">Iprodione<\/a><\/td><td class=\"oth\">7.01<\/td><td class=\"oth\">314<\/td><td class=\"oth\">245<\/td><td class=\"oth\">14<\/td><td class=\"oth\">187<\/td><td class=\"oth\">124.1<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">170.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82657-04-3\/Bifenthrin\" target=\"_blank\" rel=\"noopener\">Bifenthrin<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">166.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">165.1<\/td><td class=\"oth\">115.1<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">171.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenpropathrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39515-41-8\/Fenpropathrin\" target=\"_blank\" rel=\"noopener\">Fenpropathrin<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">265<\/td><td class=\"oth\">210<\/td><td class=\"oth\">8<\/td><td class=\"oth\">181<\/td><td class=\"oth\">152<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">172.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaphenthion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119-12-0\/Pyridaphenthion\" target=\"_blank\" rel=\"noopener\">Pyridaphenthion<\/a><\/td><td class=\"oth\">7.05<\/td><td class=\"oth\">340.1<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">77.1<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">173.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetramethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7696-12-0\/Tetramethrin\" target=\"_blank\" rel=\"noopener\">Tetramethrin<\/a><\/td><td class=\"oth\">7.06<\/td><td class=\"oth\">164<\/td><td class=\"oth\">77<\/td><td class=\"oth\">25<\/td><td class=\"oth\">164<\/td><td class=\"oth\">107<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">174.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bromopropylate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/18181-80-1\/Bromopropylate\" target=\"_blank\" rel=\"noopener\">Bromopropylate<\/a><\/td><td class=\"oth\">7.08<\/td><td class=\"oth\">340.8<\/td><td class=\"oth\">183<\/td><td class=\"oth\">15<\/td><td class=\"oth\">183<\/td><td class=\"oth\">154.9<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">175.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azinphos-ethyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2642-71-9\/Azinphos-ethyl\" target=\"_blank\" rel=\"noopener\">Azinphos-ethyl<\/a><\/td><td class=\"oth\">7.80<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><td class=\"oth\">132<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">176.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for EPN\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2104-64-5\/EPN\" target=\"_blank\" rel=\"noopener\">EPN<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">169<\/td><td class=\"oth\">77<\/td><td class=\"oth\">22<\/td><td class=\"oth\">169<\/td><td class=\"oth\">141<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">177.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosmet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/732-11-6\/Phosmet\" target=\"_blank\" rel=\"noopener\">Phosmet<\/a><\/td><td class=\"oth\">7.11<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">24<\/td><td class=\"oth\">160<\/td><td class=\"oth\">133<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">178.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methoxychlor\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-43-5\/Methoxychlor\" target=\"_blank\" rel=\"noopener\">Methoxychlor<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">227<\/td><td class=\"oth\">141<\/td><td class=\"oth\">33<\/td><td class=\"oth\">227<\/td><td class=\"oth\">169<\/td><td class=\"oth\">25<\/td><\/tr>\n<tr><td class=\"num\">179.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tebufenpyrad\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/119168-77-3\/Tebufenpyrad\" target=\"_blank\" rel=\"noopener\">Tebufenpyrad<\/a><\/td><td class=\"oth\">7.12<\/td><td class=\"oth\">333<\/td><td class=\"oth\">276<\/td><td class=\"oth\">8<\/td><td class=\"oth\">276<\/td><td class=\"oth\">171<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">180.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin ketone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/53494-70-5\/Endrin ketone\" target=\"_blank\" rel=\"noopener\">Endrin ketone<\/a><\/td><td class=\"oth\">7.13<\/td><td class=\"oth\">317<\/td><td class=\"oth\">101<\/td><td class=\"oth\">21<\/td><td class=\"oth\">315<\/td><td class=\"oth\">279<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">181.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phenothrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/26002-80-2\/Phenothrin\" target=\"_blank\" rel=\"noopener\">Phenothrin<\/a><\/td><td class=\"oth\">7.19<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">168.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">123.2<\/td><td class=\"oth\">81.1<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">182.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tetradifon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/116-29-0\/Tetradifon\" target=\"_blank\" rel=\"noopener\">Tetradifon<\/a><\/td><td class=\"oth\">7.25<\/td><td class=\"oth\">227<\/td><td class=\"oth\">199<\/td><td class=\"oth\">10<\/td><td class=\"oth\">159<\/td><td class=\"oth\">131<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">183.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyriproxyfen\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/95737-68-1\/Pyriproxyfen\" target=\"_blank\" rel=\"noopener\">Pyriproxyfen<\/a><\/td><td class=\"oth\">7.28<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">186.1<\/td><td class=\"oth\">16<\/td><td class=\"oth\">136.1<\/td><td class=\"oth\">78<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">184.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosalone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2310-17-0\/Phosalone\" target=\"_blank\" rel=\"noopener\">Phosalone<\/a><\/td><td class=\"oth\">7.29<\/td><td class=\"oth\">367<\/td><td class=\"oth\">111<\/td><td class=\"oth\">36<\/td><td class=\"oth\">182<\/td><td class=\"oth\">111<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">185.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Leptophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/21609-90-5\/Leptophos\" target=\"_blank\" rel=\"noopener\">Leptophos<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">377<\/td><td class=\"oth\">269<\/td><td class=\"oth\">37<\/td><td class=\"oth\">171<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">186.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03bb-Cyhalothrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/91465-08-6\/\u03bb-Cyhalothrin\" target=\"_blank\" rel=\"noopener\">\u03bb-Cyhalothrin<\/a><\/td><td class=\"oth\">7.31<\/td><td class=\"oth\">197.1<\/td><td class=\"oth\">141.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">197<\/td><td class=\"oth\">91<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">187.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acrinathrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/101007-06-1\/Acrinathrin\" target=\"_blank\" rel=\"noopener\">Acrinathrin<\/a><\/td><td class=\"oth\">7.32<\/td><td class=\"oth\">289.1<\/td><td class=\"oth\">93<\/td><td class=\"oth\">10<\/td><td class=\"oth\">289<\/td><td class=\"oth\">91<\/td><td class=\"oth\">24<\/td><\/tr>\n<tr><td class=\"num\">188.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyrazophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/13457-18-6\/Pyrazophos\" target=\"_blank\" rel=\"noopener\">Pyrazophos<\/a><\/td><td class=\"oth\">7.41<\/td><td class=\"oth\">265.1<\/td><td class=\"oth\">210.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">221.1<\/td><td class=\"oth\">193.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">189.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mirex\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2385-85-5\/Mirex\" target=\"_blank\" rel=\"noopener\">Mirex<\/a><\/td><td class=\"oth\">7.44<\/td><td class=\"oth\">274<\/td><td class=\"oth\">239<\/td><td class=\"oth\">15<\/td><td class=\"oth\">272<\/td><td class=\"oth\">237<\/td><td class=\"oth\">15<\/td><\/tr>\n<tr><td class=\"num\">190.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenarimol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60168-88-9\/Fenarimol\" target=\"_blank\" rel=\"noopener\">Fenarimol<\/a><\/td><td class=\"oth\">7.46<\/td><td class=\"oth\">219<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">139<\/td><td class=\"oth\">111<\/td><td class=\"oth\">16<\/td><\/tr>\n<tr><td class=\"num\">191.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azinphos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-50-0\/Azinphos-methyl\" target=\"_blank\" rel=\"noopener\">Azinphos-methyl<\/a><\/td><td class=\"oth\">7.46<\/td><td class=\"oth\">160<\/td><td class=\"oth\">77<\/td><td class=\"oth\">18<\/td><td class=\"oth\">132<\/td><td class=\"oth\">77<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">192.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyraclofos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/77458-01-6\/Pyraclofos\" target=\"_blank\" rel=\"noopener\">Pyraclofos<\/a><\/td><td class=\"oth\">7.47<\/td><td class=\"oth\">360<\/td><td class=\"oth\">139<\/td><td class=\"oth\">14<\/td><td class=\"oth\">194<\/td><td class=\"oth\">138<\/td><td class=\"oth\">18<\/td><\/tr>\n<tr><td class=\"num\">193.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61949-76-6\/cis-Permethrin\" target=\"_blank\" rel=\"noopener\">cis-Permethrin<\/a><\/td><td class=\"oth\">7.54<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">163<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">194.<\/td><td class=\"cmpd\">&lt;a class=&quot;cmpd_link&quot; title=&quot;View compound information for <i>trans<\/i>-Permethrin&#8221; title=&#8221;View compound information for <i>trans<\/i>-Permethrin&#8221; href=&#8221;https:\/\/ez.restek.com\/compound\/view\/en\/61949-77-7\/<i>trans-Permethrin&#8221;&gt;<i>trans<\/i>-Permethrin<\/a><\/td><td class=\"oth\">7.58<\/td><td class=\"oth\">183.1<\/td><td class=\"oth\">153.1<\/td><td class=\"oth\">12<\/td><td class=\"oth\">163<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">195.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pyridaben\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/96489-71-3\/Pyridaben\" target=\"_blank\" rel=\"noopener\">Pyridaben<\/a><\/td><td class=\"oth\">7.62<\/td><td class=\"oth\">147<\/td><td class=\"oth\">117<\/td><td class=\"oth\">20<\/td><td class=\"oth\">147<\/td><td class=\"oth\">119<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">196.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Coumaphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-72-4\/Coumaphos\" target=\"_blank\" rel=\"noopener\">Coumaphos<\/a><\/td><td class=\"oth\">7.66<\/td><td class=\"oth\">362<\/td><td class=\"oth\">109<\/td><td class=\"oth\">17<\/td><td class=\"oth\">210<\/td><td class=\"oth\">182<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">197.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluquinconazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/136426-54-5\/Fluquinconazole\" target=\"_blank\" rel=\"noopener\">Fluquinconazole<\/a><\/td><td class=\"oth\">7.66<\/td><td class=\"oth\">340<\/td><td class=\"oth\">108<\/td><td class=\"oth\">42<\/td><td class=\"oth\">340<\/td><td class=\"oth\">298<\/td><td class=\"oth\">14<\/td><\/tr>\n<tr><td class=\"num\">198.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Prochloraz\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/67747-09-5\/Prochloraz\" target=\"_blank\" rel=\"noopener\">Prochloraz<\/a><\/td><td class=\"oth\">7.67<\/td><td class=\"oth\">308<\/td><td class=\"oth\">70<\/td><td class=\"oth\">13<\/td><td class=\"oth\">180<\/td><td class=\"oth\">138<\/td><td class=\"oth\">12<\/td><\/tr>\n<tr><td class=\"num\">199.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyfluthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/68359-37-5\/Cyfluthrin\" target=\"_blank\" rel=\"noopener\">Cyfluthrin<\/a><\/td><td class=\"oth\">7.73<\/td><td class=\"oth\">226.1<\/td><td class=\"oth\">199<\/td><td class=\"oth\">8<\/td><td class=\"oth\">226<\/td><td class=\"oth\">151<\/td><td class=\"oth\">30<\/td><\/tr>\n<tr><td class=\"num\">200.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cypermethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52315-07-8\/Cypermethrin\" target=\"_blank\" rel=\"noopener\">Cypermethrin<\/a><\/td><td class=\"oth\">7.83<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">127<\/td><td class=\"oth\">28<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152.1<\/td><td class=\"oth\">20<\/td><\/tr>\n<tr><td class=\"num\">201.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flucythrinate 1\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70124-77-5\/Flucythrinate 1\" target=\"_blank\" rel=\"noopener\">Flucythrinate 1<\/a><\/td><td class=\"oth\">7.86<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">202.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acequinocyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57960-19-7\/Acequinocyl\" target=\"_blank\" rel=\"noopener\">Acequinocyl<\/a><\/td><td class=\"oth\">7.89<\/td><td class=\"oth\">342.4<\/td><td class=\"oth\">188.1<\/td><td class=\"oth\">14<\/td><td class=\"oth\">188<\/td><td class=\"oth\">132<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">203.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Etofenprox\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/80844-07-1\/Etofenprox\" target=\"_blank\" rel=\"noopener\">Etofenprox<\/a><\/td><td class=\"oth\">7.90<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">107<\/td><td class=\"oth\">18<\/td><td class=\"oth\">163.1<\/td><td class=\"oth\">135.1<\/td><td class=\"oth\">10<\/td><\/tr>\n<tr><td class=\"num\">204.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Flucythrinate 2\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/70124-77-5\/Flucythrinate 2\" target=\"_blank\" rel=\"noopener\">Flucythrinate 2<\/a><\/td><td class=\"oth\">7.91<\/td><td class=\"oth\">199.1<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">8<\/td><td class=\"oth\">157.1<\/td><td class=\"oth\">107.1<\/td><td class=\"oth\">13<\/td><\/tr>\n<tr><td class=\"num\">205.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fluridone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/59756-60-4\/Fluridone\" target=\"_blank\" rel=\"noopener\">Fluridone<\/a><\/td><td class=\"oth\">8.03<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">40<\/td><td class=\"oth\">328.1<\/td><td class=\"oth\">259<\/td><td class=\"oth\">26<\/td><\/tr>\n<tr><td class=\"num\">206.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenvalerate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51630-58-1\/Fenvalerate\" target=\"_blank\" rel=\"noopener\">Fenvalerate<\/a><\/td><td class=\"oth\">8.10<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">207.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Tau-fluvalinate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/102851-06-9\/Tau-fluvalinate\" target=\"_blank\" rel=\"noopener\">Tau-fluvalinate<\/a><\/td><td class=\"oth\">8.15<\/td><td class=\"oth\">252<\/td><td class=\"oth\">55<\/td><td class=\"oth\">17<\/td><td class=\"oth\">250.1<\/td><td class=\"oth\">55<\/td><td class=\"oth\">23<\/td><\/tr>\n<tr><td class=\"num\">208.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenvalerate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/51630-58-1\/Fenvalerate\" target=\"_blank\" rel=\"noopener\">Fenvalerate<\/a><\/td><td class=\"oth\">8.16<\/td><td class=\"oth\">169.1<\/td><td class=\"oth\">127.1<\/td><td class=\"oth\">10<\/td><td class=\"oth\">167.1<\/td><td class=\"oth\">125<\/td><td class=\"oth\">8<\/td><\/tr>\n<tr><td class=\"num\">209.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deltamethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52918-63-5\/Deltamethrin\" target=\"_blank\" rel=\"noopener\">Deltamethrin<\/a><\/td><td class=\"oth\">8.33<\/td><td class=\"oth\">252.9<\/td><td class=\"oth\">93.1<\/td><td class=\"oth\">19<\/td><td class=\"oth\">181.1<\/td><td class=\"oth\">152<\/td><td class=\"oth\">20<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>LPGC Rtx-5ms column kit, includes 15 m x 0.53 mm ID x 1.00 \u03bcm analytical column w\/1 m x 0.53 mm ID integrated transfer line and 5 m x 0.18 mm ID Hydroguard restrictor factory connected via SilTite connector (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/11800\" rel=\"noopener\">cat.# 11800<\/a>)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>GC multiresidue pesticide kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/32562\" rel=\"noopener\">cat.# 32562<\/a>)<\/td><\/tr><tr><td><\/td><td>Triphenylphosphate (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/33258\" rel=\"noopener\">cat.# 33258<\/a>)<\/td><\/tr><tr><td><\/td><td>Anthracene<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless (hold 0.5  min)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz 4.0 mm ID single taper inlet liner w\/ wool (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23447\" rel=\"noopener\">cat.# 23447<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\" colspan=\"2\">Oven<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Oven Temp.:<\/th><td>80 &#176;C (hold 1 min) to 320 &#176;C at 35 &#176;C\/min (hold 5 min)<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He, constant flow<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Flow Rate:<\/th><td>2 mL\/min<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>TSQ 8000<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">SIM Program:<\/th><td colspan=\"2\">35-550 m\/z<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>290 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>325 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Solvent Delay Time:<\/th><td>2  min<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Thermo Scientific TSQ 8000 Triple Quadrupole GC-MS<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Sample preparation: 10 g of homogenized strawberries were fortified with the internal standards at 20 ppb and then extracted with 10 mL of acetonitrile and QuEChERS EN 15662 salts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/25850\" rel=\"noopener\">cat.# 25850<\/a>). After centrifugation, 1 mL of supernatant was added to a 2 mL dSPE vial containing magnesium sulfate and PSA (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/26124\" rel=\"noopener\">cat.# 26124<\/a>) for cleanup. The cleaned extract was spiked with GC multiresidue pesticide mix at 1 ppm.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32562<\/li><li>33258<\/li><li>11800<\/li><li>23447<\/li><li>25850<\/li><li>26124<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>LPGC<\/li><li>multiresidue<\/li><li>pesticides<\/li><li>pesticides-food-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0572.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:\u00a0<\/strong>Fast Analysis of QuEChERS Performance Standards on LPGC Rtx-5ms (10 m x 0.32 mm ID, cat.# 11802)<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0591.png\" alt=\"Comparison of Conventional and LPGC-MS Analysis of QuEChERS Performance Standards\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FS0591<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-4 col-12 peak-33\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (30m)<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (LPGC)<\/th><th style=\"text-align: center;width: 75px\">Conc. (ppm)<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methamidophos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/10265-92-6\/Methamidophos\" target=\"_blank\" rel=\"noopener\">Methamidophos<\/a><\/td><td class=\"oth\">8.16<\/td><td class=\"oth\">3.488<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlorvos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/62-73-7\/Dichlorvos\" target=\"_blank\" rel=\"noopener\">Dichlorvos<\/a><\/td><td class=\"oth\">8.52<\/td><td class=\"oth\">3.582<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mevinphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/7786-34-7\/Mevinphos\" target=\"_blank\" rel=\"noopener\">Mevinphos<\/a><\/td><td class=\"oth\">11.51<\/td><td class=\"oth\">4.317<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Acephate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/30560-19-1\/Acephate\" target=\"_blank\" rel=\"noopener\">Acephate<\/a><\/td><td class=\"oth\">11.62<\/td><td class=\"oth\">4.356<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for o-Phenylphenol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/90-43-7\/o-Phenylphenol\" target=\"_blank\" rel=\"noopener\">o-Phenylphenol<\/a><\/td><td class=\"oth\">12.82<\/td><td class=\"oth\">4.711<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Omethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1113-02-6\/Omethoate\" target=\"_blank\" rel=\"noopener\">Omethoate<\/a><\/td><td class=\"oth\">13.98<\/td><td class=\"oth\">4.979<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">7.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dimethoate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/60-51-5\/Dimethoate\" target=\"_blank\" rel=\"noopener\">Dimethoate<\/a><\/td><td class=\"oth\">15.92<\/td><td class=\"oth\">5.453<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">8.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for gamma-BHC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/58-89-9\/gamma-BHC\" target=\"_blank\" rel=\"noopener\">gamma-BHC<\/a><\/td><td class=\"oth\">16.43<\/td><td class=\"oth\">5.615<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">9.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Diazinon\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/333-41-5\/Diazinon\" target=\"_blank\" rel=\"noopener\">Diazinon<\/a><\/td><td class=\"oth\">16.88<\/td><td class=\"oth\">5.615<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">10.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorothalonil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1897-45-6\/Chlorothalonil\" target=\"_blank\" rel=\"noopener\">Chlorothalonil<\/a><\/td><td class=\"oth\">17.18<\/td><td class=\"oth\">5.778<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">11.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Vinclozolin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50471-44-8\/Vinclozolin\" target=\"_blank\" rel=\"noopener\">Vinclozolin<\/a><\/td><td class=\"oth\">18.07<\/td><td class=\"oth\">5.95<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">12.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Carbaryl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/63-25-2\/Carbaryl\" target=\"_blank\" rel=\"noopener\">Carbaryl<\/a><\/td><td class=\"oth\">18.21<\/td><td class=\"oth\">6.023<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">13.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Metalaxyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/57837-19-1\/Metalaxyl\" target=\"_blank\" rel=\"noopener\">Metalaxyl<\/a><\/td><td class=\"oth\">18.39<\/td><td class=\"oth\">6.023<\/td><td class=\"oth\">6<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (30m)<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (LPGC)<\/th><th style=\"text-align: center;width: 75px\">Conc. (ppm)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">14.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Pirimiphos methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/29232-93-7\/Pirimiphos methyl\" target=\"_blank\" rel=\"noopener\">Pirimiphos methyl<\/a><\/td><td class=\"oth\">18.80<\/td><td class=\"oth\">6.101<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">15.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Methiocarb\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2032-65-7\/Methiocarb\" target=\"_blank\" rel=\"noopener\">Methiocarb<\/a><\/td><td class=\"oth\">18.76<\/td><td class=\"oth\">6.118<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">16.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Malathion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121-75-5\/Malathion\" target=\"_blank\" rel=\"noopener\">Malathion<\/a><\/td><td class=\"oth\">19.02<\/td><td class=\"oth\">6.149<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">17.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dichlofluanid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1085-98-9\/Dichlofluanid\" target=\"_blank\" rel=\"noopener\">Dichlofluanid<\/a><\/td><td class=\"oth\">18.96<\/td><td class=\"oth\">6.194<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">18.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenthion\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/55-38-9\/Fenthion\" target=\"_blank\" rel=\"noopener\">Fenthion<\/a><\/td><td class=\"oth\">19.23<\/td><td class=\"oth\">6.238<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">19.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Chlorpyrifos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2921-88-2\/Chlorpyrifos\" target=\"_blank\" rel=\"noopener\">Chlorpyrifos<\/a><\/td><td class=\"oth\">19.27<\/td><td class=\"oth\">6.238<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">20.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Cyprodinil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/121552-61-2\/Cyprodinil\" target=\"_blank\" rel=\"noopener\">Cyprodinil<\/a><\/td><td class=\"oth\">19.89<\/td><td class=\"oth\">6.4<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">21.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Thiabendazole\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/148-79-8\/Thiabendazole\" target=\"_blank\" rel=\"noopener\">Thiabendazole<\/a><\/td><td class=\"oth\">20.18<\/td><td class=\"oth\">6.522<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">22.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Captan\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-06-2\/Captan\" target=\"_blank\" rel=\"noopener\">Captan<\/a><\/td><td class=\"oth\">20.29<\/td><td class=\"oth\">6.545<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">23.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Folpet\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/133-07-3\/Folpet\" target=\"_blank\" rel=\"noopener\">Folpet<\/a><\/td><td class=\"oth\">20.44<\/td><td class=\"oth\">6.584<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">24.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Imazalil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/35554-44-0\/Imazalil\" target=\"_blank\" rel=\"noopener\">Imazalil<\/a><\/td><td class=\"oth\">21.34<\/td><td class=\"oth\">6.767<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">25.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Myclobutanil\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/88671-89-0\/Myclobutanil\" target=\"_blank\" rel=\"noopener\">Myclobutanil<\/a><\/td><td class=\"oth\">21.68<\/td><td class=\"oth\">6.838<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">26.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/72-20-8\/Endrin\" target=\"_blank\" rel=\"noopener\">Endrin<\/a><\/td><td class=\"oth\">22.09<\/td><td class=\"oth\">7.033<\/td><td class=\"oth\">6<\/td><\/tr>\n<\/tbody><\/table>\n<table class=\"peaks col-lg-4 col-12 peak-33\"><thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (30m)<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (LPGC)<\/th><th style=\"text-align: center;width: 75px\">Conc. (ppm)<\/th><\/tr><\/thead><tbody>\n<tr><td class=\"num\">27.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 4,4&amp;apos;-DDT\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/50-29-3\/4,4&amp;apos;-DDT\" target=\"_blank\" rel=\"noopener\">4,4&#8242;-DDT<\/a><\/td><td class=\"oth\">23.34<\/td><td class=\"oth\">7.29<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">28.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenhexamid\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/126833-17-8\/Fenhexamid\" target=\"_blank\" rel=\"noopener\">Fenhexamid<\/a><\/td><td class=\"oth\">23.34<\/td><td class=\"oth\">7.317<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">29.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Endosulfan sulfate\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1031-07-8\/Endosulfan sulfate\" target=\"_blank\" rel=\"noopener\">Endosulfan sulfate<\/a><\/td><td class=\"oth\">23.29<\/td><td class=\"oth\">7.317<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">30.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Propargite\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2312-35-8\/Propargite\" target=\"_blank\" rel=\"noopener\">Propargite<\/a><\/td><td class=\"oth\">23.73<\/td><td class=\"oth\">7.328<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">31.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Iprodione\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/36734-19-7\/Iprodione\" target=\"_blank\" rel=\"noopener\">Iprodione<\/a><\/td><td class=\"oth\">24.25<\/td><td class=\"oth\">7.469<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">32.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Bifenthrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/82657-04-3\/Bifenthrin\" target=\"_blank\" rel=\"noopener\">Bifenthrin<\/a><\/td><td class=\"oth\">24.50<\/td><td class=\"oth\">7.511<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">33.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Fenpropathrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39515-41-8\/Fenpropathrin\" target=\"_blank\" rel=\"noopener\">Fenpropathrin<\/a><\/td><td class=\"oth\">24.67<\/td><td class=\"oth\">7.572<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">34.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Dicofol\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/115-32-2\/Dicofol\" target=\"_blank\" rel=\"noopener\">Dicofol<\/a><\/td><td class=\"oth\">25.31<\/td><td class=\"oth\">7.647<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">35.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Phosalone\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/2310-17-0\/Phosalone\" target=\"_blank\" rel=\"noopener\">Phosalone<\/a><\/td><td class=\"oth\">25.34<\/td><td class=\"oth\">7.802<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">36.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Azinphos-methyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/86-50-0\/Azinphos-methyl\" target=\"_blank\" rel=\"noopener\">Azinphos-methyl<\/a><\/td><td class=\"oth\">26.63<\/td><td class=\"oth\">7.837<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">37.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for cis-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61949-76-6\/cis-Permethrin\" target=\"_blank\" rel=\"noopener\">cis-Permethrin<\/a><\/td><td class=\"oth\">26.78<\/td><td class=\"oth\">8.114<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">38.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for trans-Permethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/61949-77-7\/trans-Permethrin\" target=\"_blank\" rel=\"noopener\">trans-Permethrin<\/a><\/td><td class=\"oth\">26.93<\/td><td class=\"oth\">8.152<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">39.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Coumaphos\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56-72-4\/Coumaphos\" target=\"_blank\" rel=\"noopener\">Coumaphos<\/a><\/td><td class=\"oth\">27.22<\/td><td class=\"oth\">8.235<\/td><td class=\"oth\">6<\/td><\/tr>\n<tr><td class=\"num\">40.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Deltamethrin\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/52918-63-5\/Deltamethrin\" target=\"_blank\" rel=\"noopener\">Deltamethrin<\/a><\/td><td class=\"oth\">29.74<\/td><td class=\"oth\">9.081<\/td><td class=\"oth\">6<\/td><\/tr>\n<\/tbody><\/table><div class=\"peaknotes\">* Contaminant <\/div><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td>QuEChERS performance standards kit (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/31152\" rel=\"noopener\">cat.# 31152<\/a>)<\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>Acetonitrile<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>6 \u00b5g\/mL<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Injection<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>1 \u00b5L splitless (hold 0.5  min)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Liner:<\/th><td>Topaz, single taper inlet liner, 4.0 mm x 6.5 x 78.5 (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/23303\" rel=\"noopener\">cat.# 23303<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Temp.:<\/th><td>250 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Carrier Gas<\/th><td>He<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>Scan<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Transfer Line Temp.:<\/th><td>280 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Analyzer Type:<\/th><td>Quadrupole <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Source Temp.:<\/th><td>230 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Quad Temp.:<\/th><td>150 \u00b0C<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Electron Energy:<\/th><td>70 eV<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Tune Type:<\/th><td>PFTBA <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ionization Mode:<\/th><td>EI <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Agilent 7890A GC &amp; 5975C MSD<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>The standards were combined and diluted with acetonitrile to 6 ppm; analyzed in a 2 mL, short-cap, screw-thread vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>); and capped with a short-cap, screw-vial closure (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24495\" rel=\"noopener\">cat.# 24495<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td><b>Conventional (30 m) Analysis:<\/b><br \/>Column: Rtx-5ms, 30 m, 0.25 mm ID, 0.25 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/12623\" rel=\"noopener\">cat.# 12623<\/a>)<br \/>Temp. program: 70 \u00b0C (hold 1 min) to 330 \u00b0C at 8 \u00b0C\/min (hold 6.5 min)<br \/>Flow: 1.4 mL\/min<br \/>Scan start time: 6.5 min<br \/>Scan range: 45-550 amu<br \/>Scan rate: 5.5 scans\/sec<br \/><br \/><b>LPGC-MS Analysis:<\/b><br \/>Column: LPGC Rtx-5ms column kit, includes 10 m x 0.32 mm ID x 1.00 \u00b5m Rtx-5ms analytical column w\/5 m x 0.15 mm ID Hydroguard restrictor factory connected via SilTite connector (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/11802\" rel=\"noopener\">cat.# 11802<\/a>)<br \/>Temp. program: 70 \u00b0C (hold 1 min) to 320 \u00b0C at 35 \u00b0C\/min (hold 5 min)<br \/>Flow: 1.1 mL\/min<br \/>Scan start time: 2 min<br \/>Scan range: 45-550 amu<br \/>Scan rate: 5.5 scans\/sec<br \/><br \/>The injections were performed on different instruments under different head pressures, resulting in different analyte responses.<br \/><\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31152<\/li><li>23303<\/li><li>12623<\/li><li>11802<\/li><li>21143<\/li><li>24495<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_fs0591.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11800\">                                Catalog No. 11800                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-5ms Column Kit, 0.53 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11800\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11802\">                                Catalog No. 11802                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">LPGC Rtx-5ms Column Kit, 0.32 mm ID<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/11802\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33258\">                                Catalog No. 33258                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Triphenylphosphate Standard, 20 \u00b5g\/mL in Acetonitrile, 5 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/33258\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26124\">                                Catalog No. 26124                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS dSPE 2 mL Centrifuge Tube, Contains 150 mg MgSO4, 50 mg PSA, 100 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/26124\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31152\">                                Catalog No. 31152                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">QuEChERS Performance Standards Kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31152\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25850\">                                Catalog No. 25850                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Q-sep QuEChERS Extraction Kit (EN), 4 g MgSO4, 1 g NaCl, 1 g TSCD, 0.5 g DHS with 50 mL Centrifuge Tube, 50 Packets &amp; 50 Tubes<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25850\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32562\">                                Catalog No. 32562                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC Multiresidue Pesticide Standards Kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/32562\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This LPGC-MS pesticides analysis provides a 3x speed advantage over conventional methods, eluting 209 compounds in ~8 min from strawberry extracts. A pre-assembled low-pressure column kit simplifies the setup.<\/p>\n","protected":false},"author":11,"featured_media":7027,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[786],"tags":[],"industries-application":[2191,2193],"post-badge":[],"resource-type":[2623],"product-library":[2408,2420],"resource-technique":[2307,2311],"ppma_author":[414],"class_list":["post-43609","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-zh","industries-application-food-beverage-zh","industries-application-food-safety-zh","resource-type-featured-application","product-library-gas-chromatography-products-zh","product-library-gc-columns-zh","resource-technique-gas-chromatography-gc-zh","resource-technique-low-pressure-gc-lpgc-zh"],"acf":[],"taxonomy_info":{"category":[{"value":786,"label":"\u6587\u7ae0"}],"industries-application":[{"value":2191,"label":"\u98df\u54c1\u548c\u996e\u6599"},{"value":2193,"label":"\u98df\u54c1\u5b89\u5168"}],"resource-type":[{"value":2623,"label":"Featured Application"}],"product-library":[{"value":2408,"label":"\u6c14\u76f8\u8272\u8c31\u76f8\u5173\u4ea7\u54c1"},{"value":2420,"label":"GC\u8272\u8c31\u67f1"}],"resource-technique":[{"value":2307,"label":"\u6c14\u76f8\u8272\u8c31\uff08GC\uff09"},{"value":2311,"label":"\u4f4e\u538b GC (LPGC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FSFA3504-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":786,"name":"\u6587\u7ae0","slug":"articles-zh","term_group":0,"term_taxonomy_id":786,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":786,"category_count":511,"category_description":"","cat_name":"\u6587\u7ae0","category_nicename":"articles-zh","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43609","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43609"}],"version-history":[{"count":10,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43609\/revisions"}],"predecessor-version":[{"id":85582,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43609\/revisions\/85582"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/7027"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43609"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43609"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43609"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43609"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43609"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43609"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43609"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43609"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43609"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}