{"id":43745,"date":"2020-10-20T00:00:00","date_gmt":"2020-10-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/instrument-reference-for-2-0-ml-11-mm-crimp-top-vials\/"},"modified":"2026-01-02T14:41:01","modified_gmt":"2026-01-02T14:41:01","slug":"instrument-reference-for-2-0-ml-11-mm-crimp-top-vials","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articles\/gnot3410\/instrument-reference-for-2-0-ml-11-mm-crimp-top-vials","title":{"rendered":"Instrument Reference for 2.0 mL, 11 mm Crimp-Top Vials"},"content":{"rendered":"\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Limited Volume<br>100 \u00b5L Glass Insert,<br>Clear Plastic Vial<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"384\" height=\"892\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-01.jpg\" alt=\"\" class=\"wp-image-24274\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-01.jpg 384w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-01-129x300.jpg 129w\" sizes=\"auto, (max-width: 384px) 100vw, 384px\" \/><figcaption class=\"wp-element-caption\">cat.#<br>24653<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">Limited Volume<br>100 \u00b5L<br>Polypropylene<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"372\" height=\"874\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-02.jpg\" alt=\"\" class=\"wp-image-24280\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-02.jpg 372w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-02-128x300.jpg 128w\" sizes=\"auto, (max-width: 372px) 100vw, 372px\" \/><figcaption class=\"wp-element-caption\">cat.#<br>24651, 24652<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"wp-block-paragraph\">2.0 mL<br>Snap Seal Style<br>Clear or Amber Glass<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"394\" height=\"898\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-03.jpg\" alt=\"\" class=\"wp-image-24286\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-03.jpg 394w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-techtips-GNOT3410-03-132x300.jpg 132w\" sizes=\"auto, (max-width: 394px) 100vw, 394px\" \/><figcaption class=\"wp-element-caption\">cat.#<br>21152, 21153, 24383, 24384, 24385, 24386<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">The following instruments are compatible with 2.0 mL, 11 mm crimp-top vials. For further information or questions, please contact your Restek sales representative or technical service.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th><strong>Manufacturer<\/strong><\/th><th><strong>Instrument\/Model #<\/strong><\/th><\/tr><tr><td>A.I.M.<\/td><td>CPS-100, 200<\/td><\/tr><tr><td>A.I.<\/td><td>42 Vial Tray<\/td><\/tr><tr><td>Agilent<\/td><td>1042, 1050, 1080, 1082, 1084, 1090, 1100, 5890, 6850, 6890, 7670A, 7671A, 7672, 7673A\/B, 7683, 7890, 8042<\/td><\/tr><tr><td>Alcott<\/td><td>738<\/td><\/tr><tr><td>Alltech<\/td><td>570, 580 (standard tray)<\/td><\/tr><tr><td>Altex<\/td><td>&nbsp;<\/td><\/tr><tr><td>AMS<\/td><td>42<\/td><\/tr><tr><td>Antek<\/td><td>736 Unisampler, 738<\/td><\/tr><tr><td>ASC<\/td><td>&nbsp;<\/td><\/tr><tr><td>Bruker\/Varian<\/td><td>8100\/8200, 9100\/9090\/9095, Marathon<\/td><\/tr><tr><td>Bruker\/Varian\/Rainin<\/td><td>Dynamax AI-IA, AI-200, Dynamax Al-3<\/td><\/tr><tr><td>Carlo Erba\/Fisons<\/td><td>42 vial tray AS 800<\/td><\/tr><tr><td>Carnegie<\/td><td>CMA-250\/200<\/td><\/tr><tr><td>Chrompack<\/td><td>CP 9000 GC Series<\/td><\/tr><tr><td>CTC<\/td><td>CTC A105S<\/td><\/tr><tr><td>Dani<\/td><td>ALS 39.80, 86.80<\/td><\/tr><tr><td>Delsi<\/td><td>&nbsp;<\/td><\/tr><tr><td>Dynatech<\/td><td>42 vial tray<\/td><\/tr><tr><td>Fisons<\/td><td>42 vial tray, AS800<\/td><\/tr><tr><td>GBC<\/td><td>&nbsp;<\/td><\/tr><tr><td>Gerstel<\/td><td>&nbsp;<\/td><\/tr><tr><td>Gilson<\/td><td>231 XL, 232 XL, 233 XL, Asted XL, Aspec XL<\/td><\/tr><tr><td>Gynkotek<\/td><td>Gina, others<\/td><\/tr><tr><td>Hitachi<\/td><td>AS-2000, AS-6000<\/td><\/tr><tr><td>IBM<\/td><td>&nbsp;<\/td><\/tr><tr><td>ICI<\/td><td>other than LC 1600<\/td><\/tr><tr><td>Infochroma<\/td><td>&nbsp;<\/td><\/tr><tr><td>Jasco<\/td><td>851-AS, AS-950<\/td><\/tr><tr><td>Kipp<\/td><td>&nbsp;<\/td><\/tr><tr><td>Kontron<\/td><td>360<\/td><\/tr><tr><td>LDC<\/td><td>Marathon, Promis, other than 713<\/td><\/tr><tr><td>L.E.A.P. Technologies<\/td><td>CTC A200S, CTC A105S<\/td><\/tr><tr><td>Magnus Scientific<\/td><td>&nbsp;<\/td><\/tr><tr><td>PerkinElmer<\/td><td>Al-1, ISS 100, LC 600 42 vial tray, 420\/B, 4900,<br>Autosystem GC (HS: 10, 20 mL, Rounded), Integral 4000 (HS: 10, 20 mL Rounded), ISS 200 (HS: 6 mL)<\/td><\/tr><tr><td>Pharmacia LKB<\/td><td>2157-010<\/td><\/tr><tr><td>Phillips<\/td><td>LC-XP, 4247, 4710<\/td><\/tr><tr><td>Polymer-Labs<\/td><td>GPC 110\/210<\/td><\/tr><tr><td>Precision Sampling<\/td><td>GC111, GC 311, LC 241-60<\/td><\/tr><tr><td>Pye<\/td><td>LCXP<\/td><\/tr><tr><td>S.G.E.<\/td><td>M280D<\/td><\/tr><tr><td>Sedere<\/td><td>&nbsp;<\/td><\/tr><tr><td>Shimadzu<\/td><td>SIL-10A, 10Ai, 10AxL, AOC 20i<\/td><\/tr><tr><td>Siemens<\/td><td>AS 32, AS 200<\/td><\/tr><tr><td>Spark Holland<\/td><td>SPH 125, Marathon, Promis, Triathlon, Midas<\/td><\/tr><tr><td>Spectra-Physics<\/td><td>8875, 8880<\/td><\/tr><tr><td>Talbot<\/td><td>&nbsp;<\/td><\/tr><tr><td>Thermo Scientific<\/td><td>TRACE GC 2000, AS2000<\/td><\/tr><tr><td>Tosca 1<\/td><td>&nbsp;<\/td><\/tr><tr><td>TosoHaas<\/td><td>TSK-6080, AS-8010, AS-8020<\/td><\/tr><tr><td>Tracor<\/td><td>770, 771, 772<\/td><\/tr><tr><td>TSP<\/td><td>8875, 8880, AS 100\/1000, AS 300\/3000<\/td><\/tr><tr><td>Unicam<\/td><td>4710, LC-XP, 4247<\/td><\/tr><tr><td>United Technologies<\/td><td>&nbsp;<\/td><\/tr><tr><td>Waters<\/td><td>Alliance 2690<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Understand which instruments are compatible with 2.0 mL, 11 mm crimp-top vials.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[2784],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2375,2405],"resource-technique":[],"ppma_author":[414],"class_list":["post-43745","post","type-post","status-publish","format-standard","hentry","category-articles","product-library-sample-preparation-products","product-library-vials-accessories"],"acf":[],"taxonomy_info":{"category":[{"value":2784,"label":"Articles"}],"product-library":[{"value":2375,"label":"Sample Preparation Products"},{"value":2405,"label":"Vials &amp; Accessories"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":2784,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":2784,"taxonomy":"category","description":"","parent":0,"count":509,"filter":"raw","cat_ID":2784,"category_count":509,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43745","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43745"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43745\/revisions"}],"predecessor-version":[{"id":79139,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43745\/revisions\/79139"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43745"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43745"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43745"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43745"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43745"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43745"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43745"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43745"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43745"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}