{"id":43830,"date":"2025-03-20T00:00:00","date_gmt":"2025-03-20T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-choose-the-right-lc-guard-column\/"},"modified":"2026-09-25T18:11:56","modified_gmt":"2026-09-25T18:11:56","slug":"how-to-choose-the-right-lc-guard-column","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articoli\/gnss2975\/how-to-choose-the-right-lc-guard-column","title":{"rendered":"How to Choose the Right LC Guard Column: Protect Your Column and Enhance Performance"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Guard columns serve as a safeguard to your analysis by preventing unwanted materials from reaching your analytical column, thereby extending column lifetimes and keeping unwanted impurities from showing up in your chromatography. A guard column consists of a holder and cartridge (and sometimes a filter) and installs easily in front of the analytical column to protect it from strongly retained impurities and particulates. Restek offers three guard column configurations\u2014EXP, Roc, and Trident (direct and in-line)\u2014that are each designed to match one of our LC column families for your unique analysis. We also offer a premium inert coating for many of our guards that is especially useful in the analysis of metal-sensitive compounds. Choose the right guard column for your analysis using the steps below.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 1: Choose an LC Guard System: EXP, Roc, or Trident (Direct and In-Line)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The first step in finding the right guard column is choosing among our various guard systems: EXP, Roc, or Trident (direct or in-line). Which system to choose depends largely on your technique and analytical column. For example, if you\u2019re performing UHPLC using a smaller particle column that generates high back pressure, you need a holder to accommodate that pressure. If you\u2019re employing traditional HPLC using a legacy column, you will want a holder that houses a legacy cartridge to match. Choose the best option for your analysis among our various guard systems shown in the table below.&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-63e96b7a wp-block-columns-is-layout-flex\" style=\"padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#ced4d9;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"168\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01-1024x168.jpg\" alt=\"\" class=\"wp-image-23272\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01-1024x168.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01-300x49.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01-768x126.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01-1536x253.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\">EXP Holders and Cartridges<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Built to withstand high back pressures of UHPLC instruments (rated to 20,000 psi [1400+ bar]).&nbsp;<\/li>\n\n\n\n<li>Designed for use with Raptor and Force LC columns.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Roc Holders and Cartridges<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Specifically designed for use with Roc HPLC columns.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Trident Direct Holders and Cartridges<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Available in three levels of protection.<\/li>\n\n\n\n<li>Designed for use with legacy HPLC columns (Ultra, Pinnacle II, Pinnacle DB, Allure).<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Trident In-Line Holders and Cartridges<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Requires a coupler to attach to the analytical column.<\/li>\n\n\n\n<li>Designed for use with legacy HPLC columns (Ultra, Pinnacle II, Pinnacle DB, Allure).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Simple Particulate Protection: While a guard cartridge is the best choice for analytical column protection, it will add some retention delay because it is a packed bed. For protection from particulates with a negligible amount of additional dead volume, choose an UltraLine in-line filter or an UltraShield filter, both of which are suitable for UHPLC pressures and can be used alone or in combination with a phase-matched guard column.<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Step 2: Choose an LC Guard Cartridge Packing that Matches the Analytical Column<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Once you\u2019ve determined which guard column system is right for you, the next step is choosing an LC guard cartridge with the packing and dimensions that best match your analytical column. To obtain maximum protection without compromising selectivity or efficiency, you should select an LC guard cartridge that contains the same packing material\u2014both stationary phase and silica\u2014as your analytical column. For example, the best LC guard column to use with a Raptor Biphenyl 2.7 \u03bcm analytical column is a Raptor Biphenyl 2.7 \u03bcm guard cartridge. Use the tables below for Step 2, 3, and 4 in choosing the right guard for your analysis.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 3: Select the Correct Inner Diameter Based on Your Column Diameter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">In addition to choosing a guard cartridge packing that matches your analytical column, it\u2019s important to select an LC guard cartridge with a proper inner diameter (ID). A good general rule is that the LC guard column cartridge ID should be the same as, or one size smaller than, the ID of the analytical column. For example, a 4.0 mm ID guard cartridge should be used with a 4.6 or 4.0 mm ID analytical column, while a 2.1 mm ID guard cartridge is recommended for 3.2, 3.0, and 2.1 mm ID analytical columns.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Step 4: Consider Inert Coating to Increase Sensitivity<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Analyzing metal-sensitive compounds? We offer a premium inert coating on our most popular guard columns to provide additional protection against unwanted interactions between your analytes and the stainless-steel surfaces in your guard column. Pair your inert guard with an inert column for maximum benefits! Learn more about our inert technology <a href=\"https:\/\/discover.restek.com\/gnss4155\/accurately-analyze-metal-sensitive-compounds-with-resteks-new-inert-lc-columns\/\">here<\/a>.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#ced4d9;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<p class=\"has-medium-font-size wp-block-paragraph\">EXP Holders<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"194\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02.jpg\" alt=\"\" class=\"wp-image-23278\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02-300x65.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-02-768x166.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1821\" target=\"_blank\" rel=\"noreferrer noopener\">Raptor Guard Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1822\" target=\"_blank\" rel=\"noreferrer noopener\">Force Guard Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1823\" target=\"_blank\" rel=\"noreferrer noopener\">UltraShield Filters<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\"><strong>LC Column Family<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"142\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2.png\" alt=\"\" class=\"wp-image-29554\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2013-raptor-2-300x107.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody style=\"vertical-align: top;\">\n<tr>\n<td><strong>Column Particle Size<\/strong><\/td>\n<td><strong>Guard Cartridge\u00a0Phases<\/strong><\/td>\n<td><strong>Available Inert Phases<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1.8 (UHPLC)<\/td>\n<td>Raptor UHPLC guards: C18, ARC-18, Biphenyl, FluoroPhenyl<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>2.7<\/td>\n<td>Raptor 2.7 \u00b5m guards: C18, C8, ARC-18, Biphenyl, FluoroPhenyl, HILIC-Si, Polar X<\/td>\n<td>Raptor Inert 2.7 \u00b5m guards: C18, ARC-18, Biphenyl, HILIC-Si<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Raptor 5 \u00b5m guards: C18, ARC-18, Biphenyl, FluoroPhenyl<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<div class=\"wp-block-columns is-not-stacked-on-mobile is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"184\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2016-force-2.png\" alt=\"\" class=\"wp-image-29572\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2016-force-2.png 400w, https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-history-2016-force-2-300x138.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody style=\"vertical-align: top;\">\n<tr>\n<td><strong>Column Particle Size<\/strong><\/td>\n<td><strong>Guard Cartridge\u00a0Phases<\/strong><\/td>\n<td><strong>Available Inert Phases<\/strong><\/td>\n<\/tr>\n<tr>\n<td>1.8 (UHPLC)<\/td>\n<td>Raptor UHPLC guard cartridge in matching phase for maximum protection, or 0.2 \u00b5m UltraShield filter for clean samples when minimal dead volume is desired<strong><sup>\u2020<\/sup><\/strong><\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>Force 5 \u00b5m guards: C18, Biphenyl, FluoroPhenyl<\/td>\n<td>Force Inert 5 \u00b5m guards: C18, Biphenyl<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>Force 5 \u00b5m guards: C18, Biphenyl, FluoroPhenyl<\/td>\n<td>Force Inert 5 \u00b5m guards: C18, Biphenyl<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><sup>\u2020<\/sup>Raptor UHPLC cartridges are packed with Raptor particles, but they are compatible with any UHPLC column so they can be used with matching phases of 1.8 \u00b5m Force and 1.9 \u00b5m Pinnacle DB UHPLC columns<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#ced4d9;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<p class=\"has-medium-font-size wp-block-paragraph\">ROC Holders<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"177\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03.jpg\" alt=\"\" class=\"wp-image-23284\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03-300x59.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-03-768x151.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1824\" target=\"_blank\" data-type=\"link\" rel=\"noreferrer noopener\">Roc Guard Cartridges<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"414\" height=\"249\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Roc.jpg\" alt=\"\" class=\"wp-image-28378\" style=\"width:223px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Roc.jpg 414w, https:\/\/discover.restek.com\/wp-content\/uploads\/logo-Roc-300x180.jpg 300w\" sizes=\"auto, (max-width: 414px) 100vw, 414px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody style=\"vertical-align: top;\">\n<tr>\n<td><strong>Column Particle Size<\/strong><\/td>\n<td><strong>Guard Cartridge\u00a0Phases<\/strong><\/td>\n<td><strong>Available Inert Phases<\/strong><\/td>\n<\/tr>\n<tr>\n<td>3<\/td>\n<td>C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<td>Roc 5 \u00b5m guards: C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>FC18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<td>Roc 5 \u00b5m guards: C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-border-color is-layout-flow wp-block-column-is-layout-flow\" style=\"border-color:#ced4d9;border-width:1px;padding-top:10px;padding-right:20px;padding-bottom:10px;padding-left:20px\">\n<p class=\"has-medium-font-size wp-block-paragraph\">Trident Holders<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"208\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04.jpg\" alt=\"\" class=\"wp-image-23290\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04.jpg 900w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04-300x69.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-GNSS2975-04-768x177.jpg 768w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/c\/1825\" target=\"_blank\" rel=\"noreferrer noopener\">Ultra Guard Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1826\" target=\"_blank\" rel=\"noreferrer noopener\">Pinnacle DB Guard Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1827\" target=\"_blank\" rel=\"noreferrer noopener\">Pinnacle II Guard Cartridges<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/c\/1829\" target=\"_blank\" rel=\"noreferrer noopener\">Allure Guard Cartridges<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\">\n<table class=\"has-fixed-layout\">\n<tbody style=\"vertical-align: top;\">\n<tr>\n<td><strong>Column Family<\/strong><\/td>\n<td><strong>Column Particle Size<\/strong><\/td>\n<td><strong>Column Phases<\/strong><\/td>\n<td><strong>Guard Cartridge Phases<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\">Ultra<\/td>\n<td>3<\/td>\n<td>C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td>\n<td>Ultra 5 \u00b5m guards: C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td>\n<\/tr>\n<tr>\n<td>5<\/td>\n<td>C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td>\n<td>Ultra 5 \u00b5m guards: C18, C8, C4, C1, Biphenyl, Aromax, Aqueous C18, PFP Propyl, Cyano, IBD, Amino, Silica, Quat, Carbamate<\/td>\n<\/tr>\n<tr>\n<td>Pinnacle DB<\/td>\n<td>5<\/td>\n<td>FC18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<td>Roc 5 \u00b5m guards: C18, C8, Phenyl-Hexyl, Cyano, Silica<\/td>\n<\/tr>\n<tr>\n<td>Pinnacle II<\/td>\n<td>4<\/td>\n<td>PAH<\/td>\n<td>Pinnacle II 4 \u00b5m guards: PAH<\/td>\n<\/tr>\n<tr>\n<td>Allure<\/td>\n<td>5<\/td>\n<td>Organic Acids, AK, Silica<\/td>\n<td>Allure 5 \u00b5m guards: Organic Acids, AK, Silica<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">*Raptor UHPLC cartridges are packed with Raptor particles, but they are compatible with any UHPLC column so they can be used with matching phases of 1.8 \u00b5m Force and 1.9 \u00b5m Pinnacle DB UHPLC columns.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Note: Trident direct holders are available in three configurations, so you can select the level of protection that is best for your application. For more details, review our&nbsp;<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GNSS2423.pdf\">Trident brochure<\/a>. Trident in-line filters are also available.<\/em><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Learn how to choose the optimal LC guard column for your analysis, improving performance and protecting your analytical column.<\/p>\n","protected":false},"author":11,"featured_media":70612,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788,788],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2391,2373],"resource-technique":[2299],"ppma_author":[414],"class_list":["post-43830","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","product-library-lc-columns","product-library-liquid-chromatography-products","resource-technique-liquid-chromatography"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"},{"value":788,"label":"Articoli"}],"product-library":[{"value":2391,"label":"LC Columns"},{"value":2373,"label":"Liquid Chromatography Products"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS2975-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":788,"category_count":506,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0},{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":788,"category_count":506,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43830","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43830"}],"version-history":[{"count":35,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43830\/revisions"}],"predecessor-version":[{"id":94103,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43830\/revisions\/94103"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/70612"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43830"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43830"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43830"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43830"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43830"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43830"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43830"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43830"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43830"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}