{"id":43856,"date":"2025-02-18T00:00:00","date_gmt":"2025-02-18T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/rugged-reliable-raptor-columns-with-the-speed-of-c8\/"},"modified":"2026-08-11T15:27:38","modified_gmt":"2026-08-11T15:27:38","slug":"rugged-reliable-raptor-columns-with-the-speed-of-c8","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articoli\/gnss4423\/rugged-reliable-raptor-columns-with-the-speed-of-c8","title":{"rendered":"Rugged, Reliable Raptor Columns with the Speed of C8"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>Less retention of nonpolar analytes for faster analysis times.<\/li>\n\n\n\n<li>Proprietary column packing of superficially porous particles (SPP) and premium hardware.<\/li>\n\n\n\n<li>Superior performance in cannabis, food, clinical, and environmental testing.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u2019s Raptor C8 columns boast the dependability of our Raptor line with the capability of achieving even faster analysis times compared to C18 columns. Defined by superior ruggedness and reproducibility, Raptor columns are the go-to choice for even the most challenging workflows.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Featuring SPP core-shell&#8221; technology and a highly-selective monomeric octylsilane phase, our Raptor C8 column is a high-performing, general-purpose column for cannabis, food, clinical, and environmental testing. With a shorter alkyl chain than a traditional C18 column, this Raptor C8 boasts increased analysis speeds and improved peak shape. Like all of our Raptor columns, this Raptor C8 is exceptionally durable with long column lifetimes and dependable reproducibility.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/gnss1895\/raptor-lc-columns\/\" data-type=\"post\" data-id=\"43810\">Learn more<\/a> about our Raptor column line.<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Raptor C8 Column Description:<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><style>.kb-image43856_e73dd3-23.kb-image-is-ratio-size, .kb-image43856_e73dd3-23 .kb-image-is-ratio-size{max-width:250px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image43856_e73dd3-23.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image43856_e73dd3-23 .kb-image-is-ratio-size{align-self:unset;}.kb-image43856_e73dd3-23 figure{max-width:250px;}.kb-image43856_e73dd3-23 .image-is-svg, .kb-image43856_e73dd3-23 .image-is-svg img{width:100%;}.kb-image43856_e73dd3-23 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image43856_e73dd3-23\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"542\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-542x1024.jpg\" alt=\"\" class=\"kb-img wp-image-12226\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-542x1024.jpg 542w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-159x300.jpg 159w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-768x1451.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-813x1536.jpg 813w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-1084x2048.jpg 1084w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-ligand-gnss4423-01-scaled.jpg 1355w\" sizes=\"auto, (max-width: 542px) 100vw, 542px\" \/><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"wp-block-heading\">Stationary Phase Category:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">C8, octylsilane (L7)<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Ligand Type:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">C8<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Particle:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">2.7 \u00b5m superficially porous particle<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Pore Size:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">90 \u00c5<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Surface Area:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">130 m<sup>2<\/sup>\/g&nbsp;<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"wp-block-heading\">Recommended Usage:<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">pH Range: 2.0\u20138.0<br>Maximum Temperature: 80 \u00b0C<br>Maximum Pressure:&nbsp;600 bar\/8700 ps<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Properties:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Similar selectivity to C18 with less retention of nonpolar analytes for faster analysis times.<\/li>\n\n\n\n<li>Part of Restek\u2019s Raptor LC column line featuring 2.7 \u00b5m SPP core-shell silica.<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">When to switch to C8:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>You want to achieve faster analysis times.&nbsp;<\/li>\n\n\n\n<li>Want less retention of non-polar analytes.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:var(--wp--preset--spacing--30);padding-bottom:0;padding-left:var(--wp--preset--spacing--30)\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong>Column Interaction Profile:<\/strong><\/h4>\n\n\n<style>.kb-image43856_63dd69-c0.kb-image-is-ratio-size, .kb-image43856_63dd69-c0 .kb-image-is-ratio-size{max-width:325px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image43856_63dd69-c0.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image43856_63dd69-c0 .kb-image-is-ratio-size{align-self:unset;}.kb-image43856_63dd69-c0{max-width:325px;}.image-is-svg.kb-image43856_63dd69-c0{-webkit-flex:0 1 100%;flex:0 1 100%;}.image-is-svg.kb-image43856_63dd69-c0 img{width:100%;}.kb-image43856_63dd69-c0 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43856_63dd69-c0 size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"432\" height=\"510\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnss4423-01.jpg\" alt=\"\" class=\"kb-img wp-image-12268\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnss4423-01.jpg 432w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-profile-gnss4423-01-254x300.jpg 254w\" sizes=\"auto, (max-width: 432px) 100vw, 432px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Defining Solute Interactions:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dispersion<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h4 class=\"wp-block-heading has-medium-font-size\"><strong>Solute Retention Profile:<\/strong><\/h4>\n\n\n<style>.kb-image43856_4947e7-f2 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<figure class=\"wp-block-kadence-image kb-image43856_4947e7-f2 size-medium_large\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"253\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01-768x253.jpg\" alt=\"\" class=\"kb-img wp-image-12196\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01-768x253.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01-300x99.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01-1024x337.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01-1536x505.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/article-graph-gnss4423-01.jpg 1800w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Target Analyte Structures:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hydrocarbons&nbsp;<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Target Analyte Functionalities:<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Hydrophobic compounds<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">PEth Homologues in Whole Blood on Raptor C8: Excellent Column Lifetimes and Lot-to-Lot Reproducibility with No Carryover<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Using the Raptor C8 column, a robust and accurate analysis of the two most predominant phosphatidylethanol (PEth) homologues in whole blood was developed using a simple protein precipitation. PEth compounds are prone to carryover, but when utilizing the Raptor C8 column, no carryover was detected (Figure 1). Additionally, the Raptor C8 column demonstrated long column lifetimes and exceptional reproducibility from lot-to-lot (Figures 2 and 3).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">View the full PEth application <a href=\"https:\/\/discover.restek.com\/cfan4410\/eliminating-carryover-in-the-analysis-of-alcohol-biomarkers-in-whole-blood-on-raptor-c8-by-lc-ms-ms\/\" data-type=\"post\" data-id=\"43360\">here<\/a>.&nbsp;<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:\u00a0<\/strong>Carryover is a common challenge in PEth analysis, but when utilizing the Raptor C8 column, no carryover was detected following a blank injection after an injection of the highest calibrator standard.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0823.png\" alt=\"Carryover Study of Raptor C8\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0823<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:2<\/td><td class=\"oth\">2.37<\/td><td class=\"oth\">699.50<\/td><td class=\"oth\">279.25<\/td><td class=\"oth\">255.15<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:2-d5<\/td><td class=\"oth\">2.37<\/td><td class=\"oth\">704.50<\/td><td class=\"oth\">279.35<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:1<\/td><td class=\"oth\">2.63<\/td><td class=\"oth\">701.00<\/td><td class=\"oth\">281.25<\/td><td class=\"oth\">255.20<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:1-d5<\/td><td class=\"oth\">2.63<\/td><td class=\"oth\">706.50<\/td><td class=\"oth\">281.15<\/td><td class=\"oth\">&#8211;<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C8  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A52\" rel=\"noopener\">cat.# 9303A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A0252\" rel=\"noopener\">cat.# 9303A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>4:1 2-propanol:tetrahydrofuran<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>1000 ng\/mL in whole blood<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>5 mM Ammonium acetate, water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>90:10 Acetonitrile:2-propanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>2.50<\/td><td>0.6<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>3.00<\/td><td>0.6<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.01<\/td><td>1.0<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.50<\/td><td>1.0<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.51<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>5.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>210 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8060 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Procedure provided by RedHot Diagnostics:<br \/>The fortified blood sample (50 \u00b5L) was mixed with 50 \u00b5L of internal standard and 150 \u00b5L of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with a glass insert (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with short-cap, screw-vial closure (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>). Five microliters was injected for analysis.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9303A0252<\/li><li>9303A52<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0823.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:\u00a0<\/strong>The Raptor C8 column boasts superior column lifetimes. Exceptional peak shape and response are maintained even after 500 injections.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0824.png\" alt=\"500 Injections Lifetime Study on Raptor C8\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0824<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:2<\/td><td class=\"oth\">699.50<\/td><td class=\"oth\">279.25<\/td><td class=\"oth\">255.15<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C8  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A52\" rel=\"noopener\">cat.# 9303A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A0252\" rel=\"noopener\">cat.# 9303A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>4:1 2-propanol:tetrahydrofuran<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ng\/mL in whole blood<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>5 mM Ammonium acetate, water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>90:10 Acetonitrile:2-propanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>2.50<\/td><td>0.6<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>3.00<\/td><td>0.6<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.01<\/td><td>1.0<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.50<\/td><td>1.0<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.51<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>5.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>210 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8060 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Procedure provided by RedHot Diagnostics:<br \/>The fortified blood sample (50 \u00b5L) was mixed with 50 \u00b5L of internal standard and 150 \u00b5L of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with a glass insert (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with a short-cap, screw-vial closure (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>). Five microliters was injected for analysis.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9303A0252<\/li><li>9303A52<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0824.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:\u00a0<\/strong>From one lot to the next, every Raptor C8 column you purchase will perform the same.<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0825.png\" alt=\"Lot-to-Lot Reproducibility of Raptor C8\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0825<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion 1<\/th><th style=\"text-align: center;width: 75px\">Product Ion 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\">Phosphatidylethanol 16:0\/18:2<\/td><td class=\"oth\">699.50<\/td><td class=\"oth\">279.25<\/td><td class=\"oth\">255.15<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>Raptor C8  (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A52\" rel=\"noopener\">cat.# 9303A52<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Guard Column:<\/th><td>Raptor C8 EXP guard column cartridge 5 mm, 2.1 mm ID, 2.7 \u00b5m (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9303A0252\" rel=\"noopener\">cat.# 9303A0252<\/a>)<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>30 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>4:1 2-propanol:tetrahydrofuran<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Conc.:<\/th><td>100 ng\/mL in whole blood<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>5 mM Ammonium acetate, water <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>90:10 Acetonitrile:2-propanol <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>2.50<\/td><td>0.6<\/td><td>10<\/td><td>90<\/td><\/tr><tr><td>3.00<\/td><td>0.6<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.01<\/td><td>1.0<\/td><td>5<\/td><td>95<\/td><\/tr><tr><td>3.50<\/td><td>1.0<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>3.51<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>5.00<\/td><td>0.6<\/td><td>30<\/td><td>70<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>210 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8060 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Source:<\/th><td>Electrospray <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI- <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Mode:<\/th><td>MRM <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Procedure provided by RedHot Diagnostics:<br \/>The fortified blood sample (50 \u00b5L) was mixed with 50 \u00b5L of internal standard and 150 \u00b5L of 4:1 2-propanol:tetrahydrofuran. The mixture was vortexed for 20 seconds and centrifuged for 10 minutes at 4300 rpm. The supernatant was aliquoted to a 2 mL screw-thread vial (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with a glass insert (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with a short-cap, screw-vial closure (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>). Five microliters was injected for analysis.<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9303A0252<\/li><li>9303A52<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0825.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"background-color:#e4f7fa;padding-top:10px;padding-bottom:10px\">\n<h2 class=\"wp-block-heading has-text-align-center\">Experience Selectivity Accelerated<\/h2>\n\n\n\n<p class=\"has-text-align-center has-medium-font-size wp-block-paragraph\">Order the&nbsp;<a href=\"https:\/\/www.restek.com\/search?Ntt=Raptor+C8&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noopener\">Raptor C8 LC column<\/a>&nbsp;today.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Related Products<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9303A52\">                                Catalog No. 9303A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C8, 2.7 \u00b5m, 50 x 2.1 mm HPLC Column<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9303A52\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9303A0252\">                                Catalog No. 9303A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C8 EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9303A0252\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25938\">                                Catalog No. 25938                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Hand-Tight Fitting (Nut w\/Ferrule), 10-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25938\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                Catalog No. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">View Product<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>See how you can achieve even faster analysis times than a C18 with our rugged Raptor C8 columns.<\/p>\n","protected":false},"author":11,"featured_media":7495,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[788],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2535,2517],"resource-technique":[2334],"ppma_author":[414],"class_list":["post-43856","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articoli","product-library-colonne-lc","product-library-prodotti-per-cromatografia-liquida","resource-technique-cromatografia-liquida-lc"],"acf":[],"taxonomy_info":{"category":[{"value":788,"label":"Articoli"}],"product-library":[{"value":2535,"label":"Colonne LC"},{"value":2517,"label":"Prodotti per Cromatografia Liquida"}],"resource-technique":[{"value":2334,"label":"Cromatografia Liquida (LC)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNSS4423-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":788,"name":"Articoli","slug":"articoli","term_group":0,"term_taxonomy_id":788,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":788,"category_count":506,"category_description":"","cat_name":"Articoli","category_nicename":"articoli","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43856"}],"version-history":[{"count":24,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43856\/revisions"}],"predecessor-version":[{"id":79359,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43856\/revisions\/79359"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media\/7495"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43856"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43856"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43856"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43856"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43856"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43856"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43856"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43856"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}