{"id":43905,"date":"2020-10-26T00:00:00","date_gmt":"2020-10-26T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/packed-column-usp-phase-and-support-cross-reference-chart\/"},"modified":"2025-11-11T19:15:24","modified_gmt":"2025-11-11T19:15:24","slug":"packed-column-usp-phase-and-support-cross-reference-chart","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/articles\/phot3287\/packed-column-usp-phase-and-support-cross-reference-chart","title":{"rendered":"Packed Column USP Phase and Support Cross-Reference Chart"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong>&nbsp;&nbsp;Cross-reference a non-Restek packed column phase or support to an equivalent Restek packed column phase or support.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>LIQUID PHASES<\/strong><\/td><td><strong>USP Nomenclature<\/strong><\/td><td><strong>Restek Equivalent<\/strong><\/td><td><strong>Notes<\/strong><\/td><\/tr><tr><td>Dimethyl polysiloxane oil<\/td><td>G1<\/td><td>Rtx-1, Rt-2100, OV-101<\/td><td>&nbsp;<\/td><\/tr><tr><td>100% Dimethylpolysiloxane gum, polydimethylsiloxane, or polymethylsiloxane<\/td><td>G2<\/td><td>&nbsp; Rtx-1, OV-1 &nbsp;<\/td><td>&nbsp;<\/td><\/tr><tr><td>50% Phenyl-50% methylpolysiloxane<\/td><td>G3<\/td><td>Rt-2250, OV-17<\/td><td>&nbsp;<\/td><\/tr><tr><td>DEGS<\/td><td>G4<\/td><td>DEGS<\/td><td>Diethylene glycol succinate polyester<\/td><\/tr><tr><td>3-Cyanopropylpolysiloxane<\/td><td>G5<\/td><td>Rt-2340<\/td><td>&nbsp;<\/td><\/tr><tr><td>Trifluoropropylmethylpolysiloxane<\/td><td>G6<\/td><td>Rt-2401<\/td><td>&nbsp;<\/td><\/tr><tr><td>50% 3-Cyanopropyl-50% phenylmethylsilicone<\/td><td>G7<\/td><td>Rt-2300<\/td><td>&nbsp;<\/td><\/tr><tr><td>Methylvinylpolysiloxane<\/td><td>G9<\/td><td>Rtx-1<\/td><td>&nbsp;<\/td><\/tr><tr><td>Phenyldiethanolamine succinate polyester<\/td><td>G12<\/td><td>Phenyldiethanolamine succinate polyester<\/td><td>&nbsp;<\/td><\/tr><tr><td>D-Sorbitol<\/td><td>G13<\/td><td>Sorbitol<\/td><td>Same properties without binding.<\/td><\/tr><tr><td>Polyethylene glycol (avg. mol. wt. of 950 to 1050) or PEG 1000<\/td><td>G14<\/td><td>Carbowax 1000 (CW-1000) g\/mole<\/td><td>&nbsp;<\/td><\/tr><tr><td>Macrogol 20000 or PEG 20M<\/td><td>G16<\/td><td>Carbowax 20M (CW-20M) g\/mole; Stabilwax<\/td><td>Polyethylene glycol compound (avg. mol. wt. about 15,000). A high molecular weight compound of polyethylene glycol with a diepoxide linker.<\/td><\/tr><tr><td>25% Phenyl-25% cyanopropyl-50% methylsilicone or p\/p poli (cyano-propyl)(methyl)(phenyl)(methyl) siloxane<\/td><td>G19<\/td><td>OV-225<\/td><td>&nbsp;<\/td><\/tr><tr><td>Polyethylene glycol (avg. mol. wt. of 380 to 420)<\/td><td>G20<\/td><td>Carbowax 400 (CW-400) g\/mole<\/td><td>&nbsp;<\/td><\/tr><tr><td>Diisodecyl phthalate<\/td><td>G24<\/td><td>Diisodecyl phthalate (DIDP)<\/td><td>&nbsp;<\/td><\/tr><tr><td>Polyethylene glycol compound TPA. A high molecular weight compound of a polyethylene glycol and a diepoxide that is esterified with terephthalic acid.<\/td><td>G25<\/td><td>Carbowax 20 TPA (CW-20MTPA) g\/mole<\/td><td>&nbsp;<\/td><\/tr><tr><td>25% 2-Cyanoethyl-75% methylpolysiloxane<\/td><td>G26<\/td><td>XE-60<\/td><td>&nbsp;<\/td><\/tr><tr><td>5% Phenyl-95% methylpolysiloxane<\/td><td>G27<\/td><td>Rtx-5, SE-52<\/td><td>&nbsp;<\/td><\/tr><tr><td>25% Phenyl-75% methylpolysiloxane<\/td><td>G28<\/td><td>DC 550<\/td><td>&nbsp;<\/td><\/tr><tr><td>CO880 or nonylphenoxypoly(ethyleneoxy)ethanol (avg. ethyleneoxy chain length is 30); nonoxynol 30.<\/td><td>G31<\/td><td>IGEPAL-CO 880<\/td><td>&nbsp;<\/td><\/tr><tr><td>AT-1000 or a high molecular weight compound of a polyethylene glycol and a diepoxide that is esterified with nitroterephthalic acid.<\/td><td>G35<\/td><td>Rt-1000<\/td><td>&nbsp;<\/td><\/tr><tr><td>1% vinyl-5% phenylmethylpolysiloxane<\/td><td>G36<\/td><td>Rtx-5, SE-54<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>SOLID SUPPORTS<\/strong><\/td><td><strong>USP<\/strong><\/td><td><strong>Restek Equivalent<\/strong><\/td><td><strong>Notes<\/strong><\/td><\/tr><tr><td>Siliceous earth flux calcined, acid washed and water washed until neutral<\/td><td>S1A<\/td><td>Silcoport-W, DiatoSorb-WAW, DiatoSorb-WHP<\/td><td>&nbsp;<\/td><\/tr><tr><td>A support prepared from crushed firebrick and calcined or burned with a clay binder above 900 \u00b0C with subsequent acid wash. It may be silanized.<\/td><td>S1C<\/td><td>Chromosorb PAW, Chromosorb PAW DMDCS<\/td><td>&nbsp;<\/td><\/tr><tr><td>A support prepared from crushed firebrick and calcined or burned with a clay binder above 900 \u00b0C, not acid washed. It may be silanized.<\/td><td>S1D<\/td><td>Chromosorb PNAW<\/td><td>&nbsp;<\/td><\/tr><tr><td>Untreated siliceous earth<\/td><td>S1NS<\/td><td>DiatoSorb-WNAW<\/td><td>&nbsp;<\/td><\/tr><tr><td>Styrene-divinylbenzene co-polymer having a nominal surface area of less than 50 m<sup>2<\/sup>&nbsp;per gram and an average pore size of 0.3 to 0.4 \u03bcm<\/td><td>S2<\/td><td>Chromosorb 101<\/td><td>&nbsp;<\/td><\/tr><tr><td>Ethyl vinylbenzene-divinylbenzene co-polymer having a nominal surface area of less than 500-600 m<sup>2<\/sup>&nbsp;per gram and an average pore size of 0.0075 \u03bcm<\/td><td>S3<\/td><td>HayeSep Q<\/td><td>&nbsp;<\/td><\/tr><tr><td>Styrene-divinylbenzene copolymer with aromatic -O and -N groups having a nominal surface area of 400 to 600 m<sup>2<\/sup>\/g and an average pore diameter of 0.0076 \u03bcm<\/td><td>S4<\/td><td>Porapak R<\/td><td>&nbsp;<\/td><\/tr><tr><td>High molecular weight tetrafluoroethylene polymer 40 to 60 mesh<\/td><td>S5<\/td><td>Chromosorb T 40\/60<\/td><td>&nbsp;<\/td><\/tr><tr><td>Styrene-divinylbenzene co-polymer having a nominal surface area of less than 250 &#8211; 300 m<sup>2<\/sup>&nbsp;per gram and an average pore size of 0.0091 \u03bcm<\/td><td>S6<\/td><td>HayeSep P<\/td><td>&nbsp;<\/td><\/tr><tr><td>Graphitized carbon having a nominal surface of 12 m<sup>2<\/sup>&nbsp;per gram<\/td><td>S7<\/td><td>CarboBlack C<\/td><td>&nbsp;<\/td><\/tr><tr><td>Copolymer of 4-vinylpyridine styrene-divinylbenzene<\/td><td>S8<\/td><td>HayeSep S<\/td><td>&nbsp;<\/td><\/tr><tr><td>Porous polymer based on 2,6-diphenyl-p-phenylene oxide<\/td><td>S9<\/td><td>Tenax TA<\/td><td>&nbsp;<\/td><\/tr><tr><td>Highly cross-linked co-polymer of acrylonitrile and divinylbenzene<\/td><td>S10<\/td><td>HayeSep C<\/td><td>&nbsp;<\/td><\/tr><tr><td>Graphitized carbon having a nominal surface of 100 m<sup>2<\/sup>&nbsp;per gram modified with small amounts of petrolatum and polyethylene glycol compound<\/td><td>S11<\/td><td>CarboBlack B 80\/120 3% Rt-1500<\/td><td>&nbsp;<\/td><\/tr><tr><td>Graphitized carbon having a nominal surface area of 100 m<sup>2<\/sup>&nbsp;per g<\/td><td>S12<\/td><td>CarboBlack B<\/td><td>&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Our packed columns are prepared with SilcoSmooth tubing and stable bonded-phase technology resulting in a column with the inertness of glass and the strength of stainless steel. Learn more about our packed columns in this <a href=\"\/articles\/restek-packed-gc-columns\">technical article<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cross-reference a non-Restek packed column phase or support to an equivalent Restek packed column phase or support.<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[7],"tags":[],"industries-application":[2153],"post-badge":[],"resource-type":[564],"product-library":[2372,2384],"resource-technique":[2294],"ppma_author":[414],"class_list":["post-43905","post","type-post","status-publish","format-standard","hentry","category-articles","industries-application-clinical","resource-type-cross-reference","product-library-gas-chromatography-products","product-library-gc-columns","resource-technique-gas-chromatography-gc"],"acf":[],"taxonomy_info":{"category":[{"value":7,"label":"Articles"}],"industries-application":[{"value":2153,"label":"Clinical"}],"resource-type":[{"value":564,"label":"Cross Reference"}],"product-library":[{"value":2372,"label":"Gas Chromatography Products"},{"value":2384,"label":"GC Columns"}],"resource-technique":[{"value":2294,"label":"Gas Chromatography (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/es\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Articles","slug":"articles","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":7,"category_count":510,"category_description":"","cat_name":"Articles","category_nicename":"articles","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43905","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=43905"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43905\/revisions"}],"predecessor-version":[{"id":69847,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/43905\/revisions\/69847"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=43905"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=43905"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=43905"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=43905"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=43905"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=43905"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=43905"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=43905"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=43905"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}