{"id":51714,"date":"2013-04-12T00:00:00","date_gmt":"2013-04-12T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-should-i-condition-my-new-gc-column-details-please\/"},"modified":"2025-10-29T16:38:07","modified_gmt":"2025-10-29T16:38:07","slug":"how-should-i-condition-my-new-gc-column-details-please","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/es\/blogs-de\/gnbl4701\/how-should-i-condition-my-new-gc-column-details-please","title":{"rendered":"How should I condition my new GC column? Details please."},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We often get asked in tech service for advice about conditioning new GC columns. Although the information included with each new column covers the basics, some of our more detailed-oriented customers may still have a few additional questions. As a result, I took some time to update a GC column conditioning article that I wrote several years ago. In this revision, I included several new Restek columns that had not yet been developed when I wrote the original article, plus I included a general cautionary statement about using hydrogen (because over the past several years, many of our customers have switched from helium to hydrogen due to increased costs for the gas and\/or supply interruptions).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The revised GC capillary column conditioning article can be reviewed in the link below. I hope you find it useful.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-wp-embed is-provider-wordpress-embed wp-block-embed-wordpress-embed\"><div class=\"wp-block-embed__wrapper\">\n<blockquote class=\"wp-embedded-content\" data-secret=\"gMDDuVihcu\"><a href=\"https:\/\/discover.restek.com\/gnan1533\/how-to-condition-a-new-capillary-gc-column\/\">How to Condition a New Capillary GC Column<\/a><\/blockquote><iframe loading=\"lazy\" class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; visibility: hidden;\" title=\"&#8220;How to Condition a New Capillary GC Column&#8221; &#8212; \" src=\"https:\/\/discover.restek.com\/gnan1533\/how-to-condition-a-new-capillary-gc-column\/embed\/#?secret=VmKRopVWir#?secret=gMDDuVihcu\" data-secret=\"gMDDuVihcu\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe>\n<\/div><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">If you do review the article above, you may notice that PLOT columns and packed\/micropacked columns are not covered. If you are using one of these columns, the PDF below will be more informative.<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/discover.restek.com\/wp-content\/uploads\/600-55-001.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Embed of 600-55-001.\"><\/object><a id=\"wp-block-file--media-0372e63c-402b-41b4-9f66-bd6705c0f228\" href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/600-55-001.pdf\">600-55-001<\/a><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/600-55-001.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-0372e63c-402b-41b4-9f66-bd6705c0f228\">Download<\/a><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Please note that these instruction sheets may not cover your specific column packing, exact internal diameter (&amp; length), or column tubing material. It would be almost impossible to include detailed recommendations for every combination; however, the information provided is usually detailed enough to help determine a good starting point for your specific column.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As always, if you don\u2019t see the information you are looking for, we are one phone call or e-mail away. Thanks.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>We often get asked in tech service for advice about conditioning new GC columns. Although the information included with each new column covers the basics, some of our more detailed-oriented customers may still have a few additional questions. As a&#8230;<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[792],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[563],"product-library":[],"resource-technique":[2324],"ppma_author":[582],"class_list":["post-51714","post","type-post","status-publish","format-standard","hentry","category-blogs-de","resource-type-column-installation-and-care","resource-technique-gaschromatographie-gc"],"acf":[],"taxonomy_info":{"category":[{"value":792,"label":"Blogs"}],"resource-type":[{"value":563,"label":"Column Installation and Care"}],"resource-technique":[{"value":2324,"label":"Gaschromatographie (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/es\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":792,"name":"Blogs","slug":"blogs-de","term_group":0,"term_taxonomy_id":792,"taxonomy":"category","description":"","parent":0,"count":458,"filter":"raw","cat_ID":792,"category_count":458,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-de","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/comments?post=51714"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51714\/revisions"}],"predecessor-version":[{"id":59138,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/posts\/51714\/revisions\/59138"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/media?parent=51714"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/categories?post=51714"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/tags?post=51714"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/industries-application?post=51714"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/post-badge?post=51714"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-type?post=51714"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/product-library?post=51714"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/resource-technique?post=51714"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/es\/wp-json\/wp\/v2\/ppma_author?post=51714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}